... ... @@ -791,25 +791,23 @@
791 791  
792 792  Poll trigger settings,
793 793  
794 -* (% style="color:#037691" %)AT Command:
794 +* (% style="color:#037691" %)**AT Command:**
795 795  
796 796  There is no AT Command for this feature.
797 797  
798 798  
799 -* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06):
799 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):**
800 800  
801 -(% class="box infomessage" %)
802 -(((
803 -**0xAB 06  ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command**
804 -)))
801 +**0xAB 06  **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command
805 805  
806 806  
807 807  
805 +
808 808  ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ====
809 809  
810 810  Enable Disable DI1/DI2/DI2 as trigger,
811 811  
812 -* (% style="color:#037691" %)AT Command:
810 +* (% style="color:#037691" %)**AT Command:**
813 813  
814 814  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
815 815  
... ... @@ -818,7 +818,7 @@
818 818  
819 819  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
820 820  
821 -* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02):
819 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):**
822 822  
823 823  **0xAA 02 aa bb        **~/~/ Same as AT+DTRI=aa,bb
824 824  
... ... @@ -829,7 +829,7 @@
829 829  
830 830  Set DI1 or DI3(for LT-33222-L) trigger.
831 831  
832 -* (% style="color:#037691" %)AT Command:
830 +* (% style="color:#037691" %)**AT Command:**
833 833  
834 834  **AT+TRIG1=a,b**
835 835  
... ... @@ -847,6 +847,8 @@
847 847  * **0x09 01 aa bb cc    ** ~/~/ same as AT+TRIG1=aa,0x(bb cc)
848 848  
849 849  
848 +
849 +
850 850  ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
851 851  
852 852  Set DI2 trigger.
... ... @@ -907,11 +907,11 @@
907 907  
908 908  ==== 3.4.2.11 Trigger – Set minimum interval ====
909 909  
910 -Set AV and AC trigger minimum interval, system wont response to the second trigger within this set time after the first trigger.
910 +Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger.
911 911  
912 912  * (% style="color:#037691" %)**AT Command**
913 913  
914 -**AT+ATDC=5. Device wont response the second trigger within 5 minute after the first trigger.**
914 +**AT+ATDC=5  ** Device won't response the second trigger within 5 minute after the first trigger.
915 915  
916 916  
917 917  * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )**
... ... @@ -1121,7 +1121,7 @@
1121 1121  
1122 1122  * (% style="color:#037691" %)**AT Command:**
1123 1123  
1124 -(% style="color:#037691" %)**​​​​​​​​​​​​​​**(%%)**AT+SETCNT=aa,(bb cc dd ee) **
1124 +**AT+SETCNT=aa,(bb cc dd ee) **
1125 1125  
1126 1126  aa: 1: Set count1,
1127 1127  
... ... @@ -1145,7 +1145,7 @@
1145 1145  
1146 1146  * (% style="color:#037691" %)**AT Command:**
1147 1147  
1148 -(% style="color:#037691" %)​​​​​​​​​​​​​​(%%)**AT+CLRCOUNT ** ~/~/ clear all counting
1148 +(% style="color:#037691" %)​​​​​​​(%%)**AT+CLRCOUNT ** ~/~/ clear all counting
1149 1149  
1150 1150  
1151 1151  * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):**
... ... @@ -1403,6 +1403,7 @@
1403 1403  [[image:image-20220524100748-11.png]]
1404 1404  
1405 1405  
1406 +
1406 1406  = 4. Use AT Command =
1407 1407  
1408 1408  == 4.1 Access AT Command ==
... ... @@ -1605,8 +1605,6 @@
1605 1605  
1606 1606  (((
1607 1607  AT+CFG: Print all settings
1608 -
1609 -
1610 1610  )))
1611 1611  
1612 1612  
... ... @@ -1652,8 +1652,6 @@
1652 1652  
1653 1653  (((
1654 1654  (% style="background-color:#dcdcdc" %)ATZ
1655 -
1656 -
1657 1657  )))
1658 1658  
1659 1659  
... ... @@ -1860,6 +1860,8 @@
1860 1860  == 5.5 Can i use point to point communication for LT-22222-L? ==
1861 1861  
1862 1862  Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]]
1860 +
1861 +
1863 1863  )))
1864 1864  
1865 1865  (((
... ... @@ -1873,6 +1873,7 @@
1873 1873  
1874 1874  After restart, the status before power failure will be read from flash.
1875 1875  
1875 +
1876 1876  = 6. Trouble Shooting =
1877 1877  )))
1878 1878  
... ... @@ -1926,6 +1926,9 @@
1926 1926  * (% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865
1927 1927  * (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779
1928 1928  
1929 +
1930 +
1931 +
1929 1929  = 8. Packing Info =
1930 1930  
1931 1931  
... ... @@ -1943,6 +1943,9 @@
1943 1943  * Package Size / pcs : 14.5 x 8 x 5 cm
1944 1944  * Weight / pcs : 170g
1945 1945  
1949 +
1950 +
1951 +
1946 1946  = 9. Support =
1947 1947  
1948 1948  * (((
... ... @@ -1950,6 +1950,10 @@
1950 1950  )))
1951 1951  * (((
1952 1952  Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
1959 +
1960 +
1961 +
1962 +
1953 1953  )))
1954 1954  
1955 1955  = 10. Reference​​​​​ =