Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -181,6 +181,9 @@ 181 181 * Firmware upgradable via program port 182 182 * Counting 183 183 184 + 185 + 186 + 184 184 == 1.4 Applications == 185 185 186 186 * Smart Buildings & Home Automation ... ... @@ -190,6 +190,9 @@ 190 190 * Smart Cities 191 191 * Smart Factory 192 192 196 + 197 + 198 + 193 193 == 1.5 Hardware Variants == 194 194 195 195 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -285,6 +285,9 @@ 285 285 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 286 286 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 287 287 294 + 295 + 296 + 288 288 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 289 289 290 290 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -323,6 +323,7 @@ 323 323 * [1] RO1 relay channel is close and the RO1 LED is ON. 324 324 * [0] RO2 relay channel is open and RO2 LED is OFF; 325 325 335 + 326 326 **LT22222-L:** 327 327 328 328 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -338,6 +338,9 @@ 338 338 ** DO1 is high in case there is load between DO1 and V+. 339 339 ** DO1 LED is off in both case 340 340 351 + 352 + 353 + 341 341 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 342 342 343 343 ... ... @@ -374,7 +374,12 @@ 374 374 ((( 375 375 ((( 376 376 **AT+MOD=2** 390 +))) 391 +))) 377 377 393 +(% class="box infomessage" %) 394 +((( 395 +((( 378 378 **ATZ** 379 379 ))) 380 380 ))) ... ... @@ -387,20 +387,49 @@ 387 387 388 388 ((( 389 389 **For LT22222-L:** 408 +))) 390 390 410 +(% class="box infomessage" %) 411 +((( 412 +((( 413 +**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 414 +))) 415 +))) 391 391 392 -(% style="color:blue" %)**AT+TRIG1=0,100**(%%)** (set DI1 port to trigger on low level, valid signal is 100ms) ** 417 +(% class="box infomessage" %) 418 +((( 419 +((( 420 +**AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 421 +))) 422 +))) 393 393 394 -(% style="color:blue" %)**AT+TRIG1=1,100**(%%)** (set DI1 port to trigger on high level, valid signal is 100ms ) ** 424 +(% class="box infomessage" %) 425 +((( 426 +((( 427 +**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 428 +))) 429 +))) 395 395 396 -(% style="color:blue" %)**AT+TRIG2=0,100**(%%)** (set DI2 port to trigger on low level, valid signal is 100ms) ** 431 +(% class="box infomessage" %) 432 +((( 433 +((( 434 +**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 435 +))) 436 +))) 397 397 398 -(% style="color:blue" %)**AT+TRIG2=1,100**(%%)** (set DI2 port to trigger on high level, valid signal is 100ms ) ** 438 +(% class="box infomessage" %) 439 +((( 440 +((( 441 +**AT+SETCNT=1,60 (Set COUNT1 value to 60)** 442 +))) 443 +))) 399 399 400 -(% style="color:blue" %)**AT+SETCNT=1,60**(%%)** (Set COUNT1 value to 60)** 401 - 402 -(% style="color:blue" %)**AT+SETCNT=2,60**(%%)** (Set COUNT2 value to 60)** 445 +(% class="box infomessage" %) 446 +((( 447 +((( 448 +**AT+SETCNT=2,60 (Set COUNT2 value to 60)** 403 403 ))) 450 +))) 404 404 405 405 406 406 ... ... @@ -432,7 +432,12 @@ 432 432 ((( 433 433 ((( 434 434 **AT+MOD=3** 482 +))) 483 +))) 435 435 485 +(% class="box infomessage" %) 486 +((( 487 +((( 436 436 **ATZ** 437 437 ))) 438 438 ))) ... ... @@ -477,13 +477,20 @@ 477 477 ((( 478 478 ((( 479 479 **AT+MOD=4** 532 +))) 533 +))) 480 480 535 +(% class="box infomessage" %) 536 +((( 537 +((( 481 481 **ATZ** 482 482 ))) 483 483 ))) 484 484 542 +((( 543 + 544 +))) 485 485 486 - 487 487 ((( 488 488 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 489 489 ))) ... ... @@ -492,16 +492,35 @@ 492 492 493 493 494 494 **Plus below command for AVI1 Counting:** 554 +))) 495 495 556 +(% class="box infomessage" %) 557 +((( 558 +((( 559 +**AT+SETCNT=3,60 (set AVI Count to 60)** 560 +))) 561 +))) 496 496 497 -(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 563 +(% class="box infomessage" %) 564 +((( 565 +((( 566 +**AT+VOLMAX=20000 (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 567 +))) 568 +))) 498 498 499 -(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 570 +(% class="box infomessage" %) 571 +((( 572 +((( 573 +**AT+VOLMAX=20000,0 (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 574 +))) 575 +))) 500 500 501 -(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 502 - 503 -(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 577 +(% class="box infomessage" %) 578 +((( 579 +((( 580 +**AT+VOLMAX=20000,1 (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 504 504 ))) 582 +))) 505 505 506 506 507 507 ... ... @@ -538,7 +538,12 @@ 538 538 ((( 539 539 ((( 540 540 **AT+MOD=5** 619 +))) 620 +))) 541 541 622 +(% class="box infomessage" %) 623 +((( 624 +((( 542 542 **ATZ** 543 543 ))) 544 544 ))) ... ... @@ -564,9 +564,8 @@ 564 564 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 565 565 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 566 566 650 +**AT Command to set Trigger Condition**: 567 567 568 -(% style="color:#037691" %)**AT Command to set Trigger Condition**: 569 - 570 570 (% style="color:#4f81bd" %)**Trigger base on voltage**: 571 571 572 572 Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH> ... ... @@ -601,7 +601,7 @@ 601 601 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 602 602 603 603 604 - (% style="color:#037691" %)**Downlink Command to set Trigger Condition:**686 +**Downlink Command to set Trigger Condition:** 605 605 606 606 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 607 607 ... ... @@ -718,50 +718,61 @@ 718 718 719 719 Set device uplink interval. 720 720 721 -* (% style="color:#037691" %)**AT Command:**803 +* AT Command: 722 722 805 +(% class="box infomessage" %) 806 +((( 723 723 **AT+TDC=N ** 808 +))) 724 724 725 - 726 726 **Example: **AT+TDC=30000. Means set interval to 30 seconds 727 727 728 728 729 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x01):**813 +* Downlink Payload (prefix 0x01): 730 730 815 +(% class="box infomessage" %) 816 +((( 731 731 **0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 818 +))) 732 732 733 733 734 734 735 - 736 736 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 737 737 738 738 Set work mode. 739 739 740 -* (% style="color:#037691" %)**AT Command:**826 +* AT Command: 741 741 828 +(% class="box infomessage" %) 829 +((( 742 742 **AT+MOD=N ** 831 +))) 743 743 744 - 745 745 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 746 746 747 747 748 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):**836 +* Downlink Payload (prefix 0x0A): 749 749 750 -(% style="color:#037691" %)****(%%)**0x0A aa ** ~/~/ Same as AT+MOD=aa 838 +(% class="box infomessage" %) 839 +((( 840 +**0x0A aa ~/~/ Same as AT+MOD=aa** 841 +))) 751 751 752 752 753 753 754 - 755 755 ==== 3.4.2.3 Poll an uplink ==== 756 756 757 -* (% style="color:#037691" %)**AT Command:**847 +* AT Command: 758 758 759 759 There is no AT Command to poll uplink 760 760 761 761 762 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x08):**852 +* Downlink Payload (prefix 0x08): 763 763 764 -**0x08 FF **~/~/ Poll an uplink 854 +(% class="box infomessage" %) 855 +((( 856 +**0x08 FF ~/~/ Poll an uplink,** 857 +))) 765 765 766 766 **Example**: 0x08FF, ask device to send an Uplink 767 767 ... ... @@ -771,9 +771,12 @@ 771 771 772 772 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 773 773 774 -* (% style="color:#037691" %)**AT Command:**867 +* AT Command: 775 775 869 +(% class="box infomessage" %) 870 +((( 776 776 **AT+ADDMOD6=1 or 0** 872 +))) 777 777 778 778 1: Enable Trigger Mode 779 779 ... ... @@ -780,13 +780,11 @@ 780 780 0: Disable Trigger Mode 781 781 782 782 783 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):**879 +* Downlink Payload (prefix 0x0A 06): 784 784 785 -**0x0A 06 aa ** ~/~/ Same as AT+ADDMOD6=aa 786 - 787 787 (% class="box infomessage" %) 788 788 ((( 789 - 883 +**0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 790 790 ))) 791 791 792 792 ... ... @@ -795,12 +795,12 @@ 795 795 796 796 Poll trigger settings, 797 797 798 -* (% style="color:#037691" %)AT Command:892 +* AT Command: 799 799 800 800 There is no AT Command for this feature. 801 801 802 802 803 -* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06):897 +* Downlink Payload (prefix 0x AB 06): 804 804 805 805 (% class="box infomessage" %) 806 806 ((( ... ... @@ -813,9 +813,12 @@ 813 813 814 814 Enable Disable DI1/DI2/DI2 as trigger, 815 815 816 -* (% style="color:#037691" %)AT Command:910 +* AT Command: 817 817 912 +(% class="box infomessage" %) 913 +((( 818 818 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 915 +))) 819 819 820 820 821 821 **Example:** ... ... @@ -822,20 +822,25 @@ 822 822 823 823 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 824 824 825 -* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02):922 +* Downlink Payload (prefix 0xAA 02): 826 826 827 -**0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 924 +(% class="box infomessage" %) 925 +((( 926 +**0xAA 02 aa bb ~/~/ Same as AT+DTRI=aa,bb** 927 +))) 828 828 829 829 830 830 831 - 832 832 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 833 833 834 834 Set DI1 or DI3(for LT-33222-L) trigger. 835 835 836 -* (% style="color:#037691" %)AT Command:935 +* AT Command: 837 837 937 +(% class="box infomessage" %) 938 +((( 838 838 **AT+TRIG1=a,b** 940 +))) 839 839 840 840 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 841 841 ... ... @@ -847,19 +847,26 @@ 847 847 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 848 848 849 849 850 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 851 -* **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 952 +* Downlink Payload (prefix 0x09 01 ): 852 852 954 +(% class="box infomessage" %) 955 +((( 956 +**0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 957 +))) 853 853 959 + 960 + 854 854 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 855 855 856 856 Set DI2 trigger. 857 857 858 -* (% style="color:#037691" %)**AT Command:**965 +* AT Command: 859 859 967 +(% class="box infomessage" %) 968 +((( 860 860 **AT+TRIG2=a,b** 970 +))) 861 861 862 - 863 863 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 864 864 865 865 b : delay timing. ... ... @@ -870,72 +870,93 @@ 870 870 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 871 871 872 872 873 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):**982 +* Downlink Payload (prefix 0x09 02 ): 874 874 875 -**0x09 02 aa bb cc **~/~/ same as AT+TRIG1=aa,0x(bb cc) 984 +(% class="box infomessage" %) 985 +((( 986 +**0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 987 +))) 876 876 877 877 878 878 879 - 880 880 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 881 881 882 882 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 883 883 884 -* (% style="color:#037691" %)**AT Command**995 +* AT Command: 885 885 886 -**AT+ACLIM** 997 +(% class="box infomessage" %) 998 +((( 999 +**AT+ACLIM. ** 1000 +))) 887 887 888 888 889 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )**1003 +* Downlink Payload (prefix 0xAA 01 ): 890 890 891 -**0x AA 01 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 1005 +(% class="box infomessage" %) 1006 +((( 1007 +**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 1008 +))) 892 892 893 893 894 894 895 - 896 896 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 897 897 898 898 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 899 899 900 -* (% style="color:#037691" %)**AT Command**1016 +* AT Command: 901 901 902 -**AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 1018 +(% class="box infomessage" %) 1019 +((( 1020 +**AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 1021 +))) 903 903 904 904 905 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )**1024 +* Downlink Payload (prefix 0xAA 00 ): 906 906 907 -**0x AA 00 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 1026 +(% class="box infomessage" %) 1027 +((( 1028 +**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ** 1029 +))) 908 908 909 909 910 910 911 - 912 912 ==== 3.4.2.11 Trigger – Set minimum interval ==== 913 913 914 914 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 915 915 916 -* (% style="color:#037691" %)**AT Command**1037 +* AT Command: 917 917 1039 +(% class="box infomessage" %) 1040 +((( 918 918 **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.** 1042 +))) 919 919 920 920 921 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )**1045 +* Downlink Payload (prefix 0xAC ): 922 922 923 -**0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 1047 +(% class="box infomessage" %) 1048 +((( 1049 +**0x AC aa bb ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min)** 1050 +))) 924 924 925 925 926 926 927 - 928 928 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 929 929 930 -* (% style="color:#037691" %)**AT Command**1056 +* AT Command: 931 931 932 932 There is no AT Command to control Digital Output 933 933 934 934 935 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x02)** 936 -* **0x02 aa bb cc **~/~/ Set DO1/DO2/DO3 output 1061 +* Downlink Payload (prefix 0x02): 937 937 1063 +(% class="box infomessage" %) 938 938 ((( 1065 +**0x02 aa bb cc ~/~/ Set DO1/DO2/DO3 output** 1066 +))) 1067 + 1068 +((( 939 939 If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low. 940 940 ))) 941 941 ... ... @@ -955,19 +955,22 @@ 955 955 956 956 957 957 958 - 959 959 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 960 960 961 -* (% style="color:#037691" %)**AT Command**1090 +* AT Command: 962 962 963 963 There is no AT Command to control Digital Output 964 964 965 965 966 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA9)**1095 +* Downlink Payload (prefix 0xA9): 967 967 968 -**0xA9 aa bb cc **~/~/ Set DO1/DO2/DO3 output with time control 1097 +(% class="box infomessage" %) 1098 +((( 1099 +((( 1100 +**0xA9 aa bb cc ~/~/ Set DO1/DO2/DO3 output with time control** 1101 +))) 1102 +))) 969 969 970 - 971 971 This is to control the digital output time of DO pin. Include four bytes: 972 972 973 973 (% style="color:#4f81bd" %)**First Byte**(%%)**:** Type code (0xA9) ... ... @@ -1021,19 +1021,20 @@ 1021 1021 1022 1022 1023 1023 1024 - 1025 1025 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1026 1026 1027 -* (% style="color:#037691" %)**AT Command:**1159 +* AT Command: 1028 1028 1029 1029 There is no AT Command to control Relay Output 1030 1030 1031 1031 1032 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x03):**1164 +* Downlink Payload (prefix 0x03): 1033 1033 1034 -**0x03 aa bb **~/~/ Set RO1/RO2 output 1166 +(% class="box infomessage" %) 1167 +((( 1168 +**0x03 aa bb ~/~/ Set RO1/RO2 output** 1169 +))) 1035 1035 1036 - 1037 1037 ((( 1038 1038 If payload = 0x030100, it means set RO1 to close and RO2 to open. 1039 1039 ))) ... ... @@ -1050,19 +1050,20 @@ 1050 1050 1051 1051 1052 1052 1053 - 1054 1054 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1055 1055 1056 -* (% style="color:#037691" %)**AT Command:**1189 +* AT Command: 1057 1057 1058 1058 There is no AT Command to control Relay Output 1059 1059 1060 1060 1061 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x05):**1194 +* Downlink Payload (prefix 0x05): 1062 1062 1063 -**0x05 aa bb cc dd **~/~/ Set RO1/RO2 relay with time control 1196 +(% class="box infomessage" %) 1197 +((( 1198 +**0x05 aa bb cc dd ~/~/ Set RO1/RO2 relay with time control:** 1199 +))) 1064 1064 1065 - 1066 1066 This is to control the relay output time of relay. Include four bytes: 1067 1067 1068 1068 (% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05) ... ... @@ -1104,28 +1104,35 @@ 1104 1104 1105 1105 1106 1106 1107 - 1108 1108 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1109 1109 1110 1110 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1111 1111 1112 -* (% style="color:#037691" %)**AT Command:**1246 +* AT Command: 1113 1113 1114 -**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1248 +(% class="box infomessage" %) 1249 +((( 1250 +**AT+VOLMAX ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]** 1251 +))) 1115 1115 1116 1116 1117 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):**1254 +* Downlink Payload (prefix 0xA5): 1118 1118 1119 -**0xA5 aa bb cc **~/~/ Same as AT+VOLMAX=(aa bb),cc 1256 +(% class="box infomessage" %) 1257 +((( 1258 +**0xA5 aa bb cc ~/~/ Same as AT+VOLMAX=(aa bb),cc** 1259 +))) 1120 1120 1121 1121 1122 1122 1123 - 1124 1124 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1125 1125 1126 -* (% style="color:#037691" %)**AT Command:**1265 +* AT Command: 1127 1127 1128 -(% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) ** 1267 +(% class="box infomessage" %) 1268 +((( 1269 +**AT+SETCNT=aa,(bb cc dd ee) ** 1270 +))) 1129 1129 1130 1130 aa: 1: Set count1, 1131 1131 ... ... @@ -1136,40 +1136,51 @@ 1136 1136 Bb cc dd ee: number to be set 1137 1137 1138 1138 1139 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA8):**1281 +* Downlink Payload (prefix 0xA8): 1140 1140 1141 -**0x A8 aa bb cc dd ee **~/~/ same as AT+SETCNT=aa,(bb cc dd ee) 1283 +(% class="box infomessage" %) 1284 +((( 1285 +**0x A8 aa bb cc dd ee ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)** 1286 +))) 1142 1142 1143 1143 1144 1144 1145 - 1146 1146 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1147 1147 1148 1148 Clear counting for counting mode 1149 1149 1150 -* (% style="color:#037691" %)**AT Command:**1294 +* AT Command: 1151 1151 1152 -(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1296 +(% class="box infomessage" %) 1297 +((( 1298 +**AT+CLRCOUNT ~/~/ clear all counting** 1299 +))) 1153 1153 1301 +* Downlink Payload (prefix 0xA6): 1154 1154 1155 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** 1303 +(% class="box infomessage" %) 1304 +((( 1305 +**0x A6 01 ~/~/ clear all counting,** 1306 +))) 1156 1156 1157 -**0x A6 01 ** ~/~/ clear all counting 1158 1158 1159 1159 1160 - 1161 - 1162 1162 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1163 1163 1164 -* (% style="color:#037691" %)**AT Command:**1312 +* AT Command: 1165 1165 1166 -**AT+COUTIME=60 **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30) 1314 +(% class="box infomessage" %) 1315 +((( 1316 +**AT+COUTIME=60 ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)** 1317 +))) 1167 1167 1319 +* Downlink Payload (prefix 0xA7): 1168 1168 1169 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA7):** 1321 +(% class="box infomessage" %) 1322 +((( 1323 +**0x A7 aa bb cc ~/~/ same as AT+COUTIME =aa bb cc,** 1324 +))) 1170 1170 1171 -**0x A7 aa bb cc **~/~/ same as AT+COUTIME =aa bb cc, 1172 - 1173 1173 ((( 1174 1174 range: aa bb cc:0 to 16777215, (unit:second) 1175 1175 ... ... @@ -1177,7 +1177,6 @@ 1177 1177 ))) 1178 1178 1179 1179 1180 - 1181 1181 == 3.5 Integrate with Mydevice == 1182 1182 1183 1183 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: