... ... @@ -181,6 +181,10 @@
181 181  * Firmware upgradable via program port
182 182  * Counting
183 183  
184 +
185 +
186 +
187 +
184 184  == 1.4  Applications ==
185 185  
186 186  * Smart Buildings & Home Automation
... ... @@ -190,6 +190,10 @@
190 190  * Smart Cities
191 191  * Smart Factory
192 192  
197 +
198 +
199 +
200 +
193 193  == 1.5 Hardware Variants ==
194 194  
195 195  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -204,7 +204,6 @@
204 204  )))
205 205  
206 206  
207 -
208 208  = 2. Power ON Device =
209 209  
210 210  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -564,7 +564,6 @@
564 564  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
565 565  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
566 566  
567 -
568 568  (% style="color:#037691" %)**AT Command to set Trigger Condition**:
569 569  
570 570  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -747,7 +747,7 @@
747 747  
748 748  * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):**
749 749  
750 -(% style="color:#037691" %)**​​​​​​​**(%%)**0x0A aa    ** ~/~/ Same as AT+MOD=aa
756 +**0x0A aa    ** ~/~/ Same as AT+MOD=aa
751 751  
752 752  
753 753  
... ... @@ -784,10 +784,6 @@
784 784  
785 785  **0x0A 06 aa    ** ~/~/ Same as AT+ADDMOD6=aa
786 786  
787 -(% class="box infomessage" %)
788 -(((
789 -
790 -)))
791 791  
792 792  
793 793  
... ... @@ -795,25 +795,23 @@
795 795  
796 796  Poll trigger settings,
797 797  
798 -* (% style="color:#037691" %)AT Command:
800 +* (% style="color:#037691" %)**AT Command:**
799 799  
800 800  There is no AT Command for this feature.
801 801  
802 802  
803 -* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06):
805 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):**
804 804  
805 -(% class="box infomessage" %)
806 -(((
807 -**0xAB 06  ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command**
808 -)))
807 +**0xAB 06         **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command
809 809  
810 810  
811 811  
811 +
812 812  ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ====
813 813  
814 814  Enable Disable DI1/DI2/DI2 as trigger,
815 815  
816 -* (% style="color:#037691" %)AT Command:
816 +* (% style="color:#037691" %)**AT Command:**
817 817  
818 818  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
819 819  
... ... @@ -822,7 +822,7 @@
822 822  
823 823  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
824 824  
825 -* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02):
825 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):**
826 826  
827 827  **0xAA 02 aa bb        **~/~/ Same as AT+DTRI=aa,bb
828 828  
... ... @@ -833,7 +833,7 @@
833 833  
834 834  Set DI1 or DI3(for LT-33222-L) trigger.
835 835  
836 -* (% style="color:#037691" %)AT Command:
836 +* (% style="color:#037691" %)**AT Command:**
837 837  
838 838  **AT+TRIG1=a,b**
839 839  
... ... @@ -851,6 +851,7 @@
851 851  * **0x09 01 aa bb cc    ** ~/~/ same as AT+TRIG1=aa,0x(bb cc)
852 852  
853 853  
854 +
854 854  ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
855 855  
856 856  Set DI2 trigger.
... ... @@ -911,11 +911,11 @@
911 911  
912 912  ==== 3.4.2.11 Trigger – Set minimum interval ====
913 913  
914 -Set AV and AC trigger minimum interval, system wont response to the second trigger within this set time after the first trigger.
915 +Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger.
915 915  
916 916  * (% style="color:#037691" %)**AT Command**
917 917  
918 -**AT+ATDC=5. Device wont response the second trigger within 5 minute after the first trigger.**
919 +**AT+ATDC=5        ** Device won't response the second trigger within 5 minute after the first trigger.
919 919  
920 920  
921 921  * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )**
... ... @@ -1125,7 +1125,7 @@
1125 1125  
1126 1126  * (% style="color:#037691" %)**AT Command:**
1127 1127  
1128 -(% style="color:#037691" %)**​​​​​​​​​​​​​​**(%%)**AT+SETCNT=aa,(bb cc dd ee) **
1129 +**AT+SETCNT=aa,(bb cc dd ee) **
1129 1129  
1130 1130  aa: 1: Set count1,
1131 1131  
... ... @@ -1149,7 +1149,7 @@
1149 1149  
1150 1150  * (% style="color:#037691" %)**AT Command:**
1151 1151  
1152 -(% style="color:#037691" %)​​​​​​​​​​​​​​(%%)**AT+CLRCOUNT ** ~/~/ clear all counting
1153 +**AT+CLRCOUNT ** ~/~/ clear all counting
1153 1153  
1154 1154  
1155 1155  * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):**
... ... @@ -1407,6 +1407,7 @@
1407 1407  [[image:image-20220524100748-11.png]]
1408 1408  
1409 1409  
1411 +
1410 1410  = 4. Use AT Command =
1411 1411  
1412 1412  == 4.1 Access AT Command ==
... ... @@ -1609,8 +1609,6 @@
1609 1609  
1610 1610  (((
1611 1611  AT+CFG: Print all settings
1612 -
1613 -
1614 1614  )))
1615 1615  
1616 1616  
... ... @@ -1656,8 +1656,6 @@
1656 1656  
1657 1657  (((
1658 1658  (% style="background-color:#dcdcdc" %)ATZ
1659 -
1660 -
1661 1661  )))
1662 1662  
1663 1663  
... ... @@ -1864,6 +1864,8 @@
1864 1864  == 5.5 Can i use point to point communication for LT-22222-L? ==
1865 1865  
1866 1866  Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]]
1865 +
1866 +
1867 1867  )))
1868 1868  
1869 1869  (((
... ... @@ -1877,6 +1877,7 @@
1877 1877  
1878 1878  After restart, the status before power failure will be read from flash.
1879 1879  
1880 +
1880 1880  = 6. Trouble Shooting =
1881 1881  )))
1882 1882  
... ... @@ -1930,6 +1930,8 @@
1930 1930  * (% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865
1931 1931  * (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779
1932 1932  
1934 +
1935 +
1933 1933  = 8. Packing Info =
1934 1934  
1935 1935  
... ... @@ -1947,6 +1947,8 @@
1947 1947  * Package Size / pcs : 14.5 x 8 x 5 cm
1948 1948  * Weight / pcs : 170g
1949 1949  
1953 +
1954 +
1950 1950  = 9. Support =
1951 1951  
1952 1952  * (((
... ... @@ -1954,6 +1954,10 @@
1954 1954  )))
1955 1955  * (((
1956 1956  Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
1962 +
1963 +
1964 +
1965 +
1957 1957  )))
1958 1958  
1959 1959  = 10. Reference​​​​​ =