Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,7 +1,6 @@ 1 1 (% style="text-align:center" %) 2 2 [[image:image-20220523163353-1.jpeg||height="604" width="500"]] 3 3 4 -**LT-22222-L LoRa IO Controller User Manual ** 5 5 6 6 7 7 **Table of Contents:** ... ... @@ -42,6 +42,8 @@ 42 42 43 43 ((( 44 44 2) User can set up a LoRaWAN gateway locally and configure the controller to connect to the gateway via wireless. 44 + 45 + 45 45 ))) 46 46 47 47 ((( ... ... @@ -173,6 +173,7 @@ 173 173 174 174 == 1.3 Features == 175 175 177 + 176 176 * LoRaWAN Class A & Class C protocol 177 177 * Optional Customized LoRa Protocol 178 178 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865 ... ... @@ -181,8 +181,11 @@ 181 181 * Firmware upgradable via program port 182 182 * Counting 183 183 186 + 187 + 184 184 == 1.4 Applications == 185 185 190 + 186 186 * Smart Buildings & Home Automation 187 187 * Logistics and Supply Chain Management 188 188 * Smart Metering ... ... @@ -190,8 +190,11 @@ 190 190 * Smart Cities 191 191 * Smart Factory 192 192 198 + 199 + 193 193 == 1.5 Hardware Variants == 194 194 202 + 195 195 (% border="1" style="background-color:#f7faff; width:500px" %) 196 196 |(% style="width:103px" %)**Model**|(% style="width:131px" %)**Photo**|(% style="width:334px" %)**Description** 197 197 |(% style="width:103px" %)**LT22222-L**|(% style="width:131px" %)[[image:1653296302983-697.png]]|(% style="width:334px" %)((( ... ... @@ -204,9 +204,9 @@ 204 204 ))) 205 205 206 206 207 - 208 208 = 2. Power ON Device = 209 209 217 + 210 210 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. 211 211 212 212 ((( ... ... @@ -221,19 +221,24 @@ 221 221 222 222 == 3.1 How it works? == 223 223 232 + 224 224 ((( 225 -The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on **TX LED** will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. **TX LED** will be on for 5 seconds after joined in network. When there is message from server, the **RX LED**will be on for 1 second.234 +The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%) will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. (% style="color:green" %)**TX LED**(%%) will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second. 226 226 ))) 227 227 228 228 ((( 229 -In case user can ’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.238 +In case user can't set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 230 230 ))) 231 231 232 232 242 + 233 233 == 3.2 Example to join LoRaWAN network == 234 234 245 + 235 235 ((( 236 236 This chapter shows an example for how to join the TTN LoRaWAN Network. Below is the network structure, we use our LG308 as LoRaWAN gateway here. 248 + 249 + 237 237 ))) 238 238 239 239 [[image:image-20220523172350-1.png||height="266" width="864"]] ... ... @@ -241,6 +241,8 @@ 241 241 242 242 ((( 243 243 The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN: 257 + 258 + 244 244 ))) 245 245 246 246 ((( ... ... @@ -266,6 +266,7 @@ 266 266 [[image:1653298023685-319.png]] 267 267 268 268 284 + 269 269 ((( 270 270 (% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 271 271 ))) ... ... @@ -276,17 +276,21 @@ 276 276 277 277 == 3.3 Uplink Payload == 278 278 295 + 279 279 There are five working modes + one interrupt mode on LT for different type application: 280 280 281 -* **MOD1**: (default setting): 2 x ACI + 2AVI + DI + DO + RO 282 -* **MOD2**: Double DI Counting + DO + RO 283 -* **MOD3**: Single DI Counting + 2 x ACI + DO + RO 284 -* **MOD4**: Single DI Counting + 1 x Voltage Counting + DO + RO 285 -* **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 286 -* **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 298 +* (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO 299 +* (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO 300 +* (% style="color:blue" %)**MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO 301 +* (% style="color:blue" %)**MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO 302 +* (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 303 +* (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5 287 287 305 + 306 + 288 288 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 289 289 309 + 290 290 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. 291 291 292 292 [[image:image-20220523174024-3.png]] ... ... @@ -338,6 +338,8 @@ 338 338 ** DO1 is high in case there is load between DO1 and V+. 339 339 ** DO1 LED is off in both case 340 340 361 + 362 + 341 341 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 342 342 343 343 ... ... @@ -406,11 +406,14 @@ 406 406 407 407 === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI === 408 408 431 + 409 409 **LT22222-L**: This mode the DI1 is used as a counting pin. 410 410 411 411 [[image:image-20220523181246-5.png]] 412 412 413 413 ((( 437 + 438 + 414 414 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 415 415 ))) 416 416 ... ... @@ -424,6 +424,7 @@ 424 424 (% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 425 425 ))) 426 426 452 + 427 427 ((( 428 428 **To use counting mode, please run:** 429 429 ))) ... ... @@ -556,8 +556,8 @@ 556 556 557 557 For example, if user has configured below commands: 558 558 559 -* **AT+MOD=1 ** **~-~->** The normal working mode 560 -* **AT+ADDMOD6=1** **~-~->** Enable trigger 585 +* **AT+MOD=1 ** **~-~->** The normal working mode 586 +* **AT+ADDMOD6=1** **~-~->** Enable trigger 561 561 562 562 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 563 563 ... ... @@ -564,9 +564,9 @@ 564 564 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 565 565 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 566 566 567 - 568 568 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 569 569 595 + 570 570 (% style="color:#4f81bd" %)**Trigger base on voltage**: 571 571 572 572 Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH> ... ... @@ -688,14 +688,14 @@ 688 688 ((( 689 689 690 690 691 -**Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]] 692 - 693 - 717 +**Decoder for TTN/loraserver/ChirpStack**: [[https:~~/~~/www.dropbox.com/sh/wtrzu7avdtkmn3z/AACK5NwOMkU9jnvf1uCMuqrVa?dl=0>>https://www.dropbox.com/sh/wtrzu7avdtkmn3z/AACK5NwOMkU9jnvf1uCMuqrVa?dl=0]] 694 694 ))) 695 695 696 696 721 + 697 697 == 3.4 Configure LT via AT or Downlink == 698 698 724 + 699 699 User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands 700 700 701 701 ((( ... ... @@ -706,8 +706,12 @@ 706 706 707 707 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 708 708 735 + 736 + 737 + 709 709 === 3.4.1 Common Commands === 710 710 740 + 711 711 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 712 712 713 713 ... ... @@ -714,8 +714,10 @@ 714 714 715 715 === 3.4.2 Sensor related commands === 716 716 747 + 717 717 ==== 3.4.2.1 Set Transmit Interval ==== 718 718 750 + 719 719 Set device uplink interval. 720 720 721 721 * (% style="color:#037691" %)**AT Command:** ... ... @@ -735,6 +735,7 @@ 735 735 736 736 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 737 737 770 + 738 738 Set work mode. 739 739 740 740 * (% style="color:#037691" %)**AT Command:** ... ... @@ -747,7 +747,7 @@ 747 747 748 748 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 749 749 750 - (% style="color:#037691" %)****(%%)**0x0A aa ** ~/~/ Same as AT+MOD=aa783 +**0x0A aa ** ~/~/ Same as AT+MOD=aa 751 751 752 752 753 753 ... ... @@ -754,6 +754,7 @@ 754 754 755 755 ==== 3.4.2.3 Poll an uplink ==== 756 756 790 + 757 757 * (% style="color:#037691" %)**AT Command:** 758 758 759 759 There is no AT Command to poll uplink ... ... @@ -767,16 +767,15 @@ 767 767 768 768 769 769 804 + 770 770 ==== 3.4.2.4 Enable Trigger Mode ==== 771 771 807 + 772 772 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 773 773 774 -* (% style="color:#037691" %)AT Command: 810 +* (% style="color:#037691" %)**AT Command:** 775 775 776 -(% class="box infomessage" %) 777 -((( 778 778 **AT+ADDMOD6=1 or 0** 779 -))) 780 780 781 781 1: Enable Trigger Mode 782 782 ... ... @@ -783,38 +783,36 @@ 783 783 0: Disable Trigger Mode 784 784 785 785 786 -* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 819 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):** 787 787 788 -(% class="box infomessage" %) 789 -((( 790 -**0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 791 -))) 821 +**0x0A 06 aa ** ~/~/ Same as AT+ADDMOD6=aa 792 792 793 793 794 794 825 + 795 795 ==== 3.4.2.5 Poll trigger settings ==== 796 796 828 + 797 797 Poll trigger settings, 798 798 799 -* (% style="color:#037691" %)AT Command: 831 +* (% style="color:#037691" %)**AT Command:** 800 800 801 801 There is no AT Command for this feature. 802 802 803 803 804 -* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 836 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):** 805 805 806 -(% class="box infomessage" %) 807 -((( 808 -**0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 809 -))) 838 +**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 810 810 811 811 812 812 842 + 813 813 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 814 814 845 + 815 815 Enable Disable DI1/DI2/DI2 as trigger, 816 816 817 -* (% style="color:#037691" %)AT Command: 848 +* (% style="color:#037691" %)**AT Command:** 818 818 819 819 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 820 820 ... ... @@ -823,7 +823,7 @@ 823 823 824 824 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 825 825 826 -* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 857 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):** 827 827 828 828 **0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 829 829 ... ... @@ -832,9 +832,10 @@ 832 832 833 833 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 834 834 866 + 835 835 Set DI1 or DI3(for LT-33222-L) trigger. 836 836 837 -* (% style="color:#037691" %)AT Command: 869 +* (% style="color:#037691" %)**AT Command:** 838 838 839 839 **AT+TRIG1=a,b** 840 840 ... ... @@ -852,8 +852,10 @@ 852 852 * **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 853 853 854 854 887 + 855 855 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 856 856 890 + 857 857 Set DI2 trigger. 858 858 859 859 * (% style="color:#037691" %)**AT Command:** ... ... @@ -880,6 +880,7 @@ 880 880 881 881 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 882 882 917 + 883 883 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 884 884 885 885 * (% style="color:#037691" %)**AT Command** ... ... @@ -896,6 +896,7 @@ 896 896 897 897 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 898 898 934 + 899 899 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 900 900 901 901 * (% style="color:#037691" %)**AT Command** ... ... @@ -912,11 +912,12 @@ 912 912 913 913 ==== 3.4.2.11 Trigger – Set minimum interval ==== 914 914 915 -Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 916 916 952 +Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger. 953 + 917 917 * (% style="color:#037691" %)**AT Command** 918 918 919 -**AT+ATDC=5 .Device won’t response the second trigger within 5 minute after the first trigger.**956 +**AT+ATDC=5 ** Device won't response the second trigger within 5 minute after the first trigger. 920 920 921 921 922 922 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** ... ... @@ -923,11 +923,18 @@ 923 923 924 924 **0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 925 925 963 +((( 964 + 926 926 966 +(% style="color:red" %)Note: ATDC setting must be more than 5min 967 +))) 927 927 928 928 970 + 971 + 929 929 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 930 930 974 + 931 931 * (% style="color:#037691" %)**AT Command** 932 932 933 933 There is no AT Command to control Digital Output ... ... @@ -959,6 +959,7 @@ 959 959 960 960 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 961 961 1006 + 962 962 * (% style="color:#037691" %)**AT Command** 963 963 964 964 There is no AT Command to control Digital Output ... ... @@ -1025,6 +1025,7 @@ 1025 1025 1026 1026 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1027 1027 1073 + 1028 1028 * (% style="color:#037691" %)**AT Command:** 1029 1029 1030 1030 There is no AT Command to control Relay Output ... ... @@ -1054,6 +1054,7 @@ 1054 1054 1055 1055 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1056 1056 1103 + 1057 1057 * (% style="color:#037691" %)**AT Command:** 1058 1058 1059 1059 There is no AT Command to control Relay Output ... ... @@ -1077,7 +1077,7 @@ 1077 1077 1078 1078 (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status: 1079 1079 1080 -[[image:image-20220 524093831-10.png]]1127 +[[image:image-20220714135731-1.png||height="406" width="627"]] 1081 1081 1082 1082 1083 1083 (% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms ... ... @@ -1087,21 +1087,21 @@ 1087 1087 1088 1088 **Example payload:** 1089 1089 1090 -**~1. 05 01 11 07 D 0**1137 +**~1. 05 01 11 07 D** 1091 1091 1092 -Relay1 and Relay 2 will be set to N O, last 2 seconds, then change back to original state.1139 +Relay1 and Relay 2 will be set to NC , last 2 seconds, then change back to original state. 1093 1093 1094 1094 **2. 05 01 10 07 D0** 1095 1095 1096 -Relay1 will change to N O, Relay2 will change to NC, last 2 seconds, then both change back to original state.1143 +Relay1 will change to NC, Relay2 will change to NO, last 2 seconds, then both change back to original state. 1097 1097 1098 1098 **3. 05 00 01 07 D0** 1099 1099 1100 -Relay1 will change to N C, Relay2 will change to NO, last 2 seconds, then relay change to NO,C.1147 +Relay1 will change to NO, Relay2 will change to NC, last 2 seconds, then relay change to NC,Relay2 change to NO. 1101 1101 1102 1102 **4. 05 00 00 07 D0** 1103 1103 1104 -Relay 1 & relay2 will change to N C, last 2 seconds, then both change to NO.1151 +Relay 1 & relay2 will change to NO, last 2 seconds, then both change to NC. 1105 1105 1106 1106 1107 1107 ... ... @@ -1108,6 +1108,7 @@ 1108 1108 1109 1109 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1110 1110 1158 + 1111 1111 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1112 1112 1113 1113 * (% style="color:#037691" %)**AT Command:** ... ... @@ -1124,9 +1124,10 @@ 1124 1124 1125 1125 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1126 1126 1175 + 1127 1127 * (% style="color:#037691" %)**AT Command:** 1128 1128 1129 - (% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) **1178 +**AT+SETCNT=aa,(bb cc dd ee) ** 1130 1130 1131 1131 aa: 1: Set count1, 1132 1132 ... ... @@ -1146,11 +1146,12 @@ 1146 1146 1147 1147 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1148 1148 1198 + 1149 1149 Clear counting for counting mode 1150 1150 1151 1151 * (% style="color:#037691" %)**AT Command:** 1152 1152 1153 - (% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting1203 +**AT+CLRCOUNT ** ~/~/ clear all counting 1154 1154 1155 1155 1156 1156 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** ... ... @@ -1162,6 +1162,7 @@ 1162 1162 1163 1163 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1164 1164 1215 + 1165 1165 * (% style="color:#037691" %)**AT Command:** 1166 1166 1167 1167 **AT+COUTIME=60 **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30) ... ... @@ -1181,6 +1181,7 @@ 1181 1181 1182 1182 == 3.5 Integrate with Mydevice == 1183 1183 1235 + 1184 1184 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: 1185 1185 1186 1186 ((( ... ... @@ -1189,14 +1189,15 @@ 1189 1189 1190 1190 ((( 1191 1191 (% style="color:blue" %)**Step 2**(%%): To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps: 1244 + 1245 + 1192 1192 ))) 1193 1193 1194 -[[image:1 653356737703-362.png||height="232" width="732"]]1248 +[[image:image-20220719105525-1.png||height="377" width="677"]] 1195 1195 1196 -[[image:image-20220524094641-11.png||height="390" width="723"]] 1197 1197 1198 1198 1199 -[[image:image-20220 524094641-12.png||height="402" width="718"]]1252 +[[image:image-20220719110247-2.png||height="388" width="683"]] 1200 1200 1201 1201 1202 1202 (% style="color:blue" %)**Step 3**(%%): Create an account or log in Mydevices. ... ... @@ -1229,8 +1229,10 @@ 1229 1229 1230 1230 == 3.6 Interface Detail == 1231 1231 1285 + 1232 1232 === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) === 1233 1233 1288 + 1234 1234 Support NPN Type sensor 1235 1235 1236 1236 [[image:1653356991268-289.png]] ... ... @@ -1239,6 +1239,7 @@ 1239 1239 1240 1240 === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) === 1241 1241 1297 + 1242 1242 ((( 1243 1243 The DI port of LT-22222-L can support NPN or PNP output sensor. 1244 1244 ))) ... ... @@ -1245,7 +1245,9 @@ 1245 1245 1246 1246 ((( 1247 1247 ((( 1248 -Internal circuit as below, the NEC2501 is a photocoupler, the Active current (from NEC2501 pin 1 to pin 2 is 1ma and the max current is 50mA. When there is active current pass NEC2501 pin1 to pin2. The DI will be active high 1304 +Internal circuit as below, the NEC2501 is a photocoupler, the Active current (from NEC2501 pin 1 to pin 2 is 1ma and the max current is 50mA. When there is active current pass NEC2501 pin1 to pin2. The DI will be active high. 1305 + 1306 + 1249 1249 ))) 1250 1250 ))) 1251 1251 ... ... @@ -1290,6 +1290,8 @@ 1290 1290 1291 1291 ((( 1292 1292 1351 + 1352 + 1293 1293 ))) 1294 1294 1295 1295 ((( ... ... @@ -1321,6 +1321,8 @@ 1321 1321 1322 1322 ((( 1323 1323 1384 + 1385 + 1324 1324 ))) 1325 1325 1326 1326 ((( ... ... @@ -1354,6 +1354,7 @@ 1354 1354 1355 1355 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1356 1356 1419 + 1357 1357 NPN output: GND or Float. Max voltage can apply to output pin is 36v. 1358 1358 1359 1359 [[image:1653357531600-905.png]] ... ... @@ -1362,6 +1362,7 @@ 1362 1362 1363 1363 === 3.6.4 Analog Input Interface === 1364 1364 1428 + 1365 1365 The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is: 1366 1366 1367 1367 ... ... @@ -1393,6 +1393,7 @@ 1393 1393 1394 1394 === 3.6.5 Relay Output === 1395 1395 1460 + 1396 1396 ((( 1397 1397 The LT serial controller has two relay interfaces; each interface uses two pins of the screw terminal. User can connect other device’s Power Line to in serial of RO1_1 and RO_2. Such as below: 1398 1398 ))) ... ... @@ -1405,13 +1405,17 @@ 1405 1405 1406 1406 == 3.7 LEDs Indicators == 1407 1407 1473 + 1408 1408 [[image:image-20220524100748-11.png]] 1409 1409 1410 1410 1477 + 1411 1411 = 4. Use AT Command = 1412 1412 1480 + 1413 1413 == 4.1 Access AT Command == 1414 1414 1483 + 1415 1415 LT supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to LT for using AT command, as below. 1416 1416 1417 1417 [[image:1653358238933-385.png]] ... ... @@ -1610,8 +1610,6 @@ 1610 1610 1611 1611 ((( 1612 1612 AT+CFG: Print all settings 1613 - 1614 - 1615 1615 ))) 1616 1616 1617 1617 ... ... @@ -1618,6 +1618,7 @@ 1618 1618 1619 1619 == 4.2 Common AT Command Sequence == 1620 1620 1688 + 1621 1621 === 4.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1622 1622 1623 1623 ((( ... ... @@ -1657,8 +1657,6 @@ 1657 1657 1658 1658 ((( 1659 1659 (% style="background-color:#dcdcdc" %)ATZ 1660 - 1661 - 1662 1662 ))) 1663 1663 1664 1664 ... ... @@ -1743,13 +1743,16 @@ 1743 1743 1744 1744 === 4.2.3 Change to Class A === 1745 1745 1812 + 1746 1746 If sensor JOINED 1747 1747 (% style="background-color:#dcdcdc" %)AT+CLASS=A 1748 1748 ATZ 1749 1749 1750 1750 1818 + 1751 1751 = 5. FAQ = 1752 1752 1821 + 1753 1753 == 5.1 How to upgrade the image? == 1754 1754 1755 1755 ... ... @@ -1771,7 +1771,9 @@ 1771 1771 1772 1772 1773 1773 (% style="color:blue" %)**For LT-22222-L**(%%): 1774 -Hold down the PRO button and then momentarily press the RST reset button and the **DO1 led** will change from OFF to ON. When **DO1 LED** is on, it means the device is in download mode. 1843 +Hold down the PRO button and then momentarily press the RST reset button and the (% style="color:red" %)**DO1 led**(%%) will change from OFF to ON. When (% style="color:red" %)**DO1 LED**(%%) is on, it means the device is in download mode. 1844 + 1845 + 1775 1775 ))) 1776 1776 1777 1777 [[image:image-20220524103407-12.png]] ... ... @@ -1783,6 +1783,7 @@ 1783 1783 1784 1784 (% style="color:red" %)**Notice**(%%): In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is: 1785 1785 1857 + 1786 1786 [[image:1653360054704-518.png||height="186" width="745"]] 1787 1787 1788 1788 ... ... @@ -1791,6 +1791,8 @@ 1791 1791 1792 1792 1793 1793 == 5.2 How to change the LoRa Frequency Bands/Region? == 1866 + 1867 + 1794 1794 ))) 1795 1795 ))) 1796 1796 ... ... @@ -1801,7 +1801,10 @@ 1801 1801 ((( 1802 1802 1803 1803 1878 + 1804 1804 == 5.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? == 1880 + 1881 + 1805 1805 ))) 1806 1806 1807 1807 ((( ... ... @@ -1819,7 +1819,7 @@ 1819 1819 ))) 1820 1820 1821 1821 ((( 1822 -(% style="color: #4f81bd" %)**Step1**(%%): Log in TTN, Create an ABP device in the application and input the network session key (NETSKEY), app session key (APPSKEY) from the device.1899 +(% style="color:blue" %)**Step1**(%%): Log in TTN, Create an ABP device in the application and input the network session key (NETSKEY), app session key (APPSKEY) from the device. 1823 1823 ))) 1824 1824 1825 1825 ((( ... ... @@ -1827,12 +1827,12 @@ 1827 1827 ))) 1828 1828 1829 1829 ((( 1830 -(% style="color:red" %)Note: user just need to make sure above three keys match, User can change either in TTN or Device to make then match. In TTN, NETSKEY and APPSKEY can be configured by user in setting page, but Device Addr is generated by TTN. 1907 +(% style="color:red" %)**Note: user just need to make sure above three keys match, User can change either in TTN or Device to make then match. In TTN, NETSKEY and APPSKEY can be configured by user in setting page, but Device Addr is generated by TTN.** 1831 1831 ))) 1832 1832 1833 1833 1834 1834 ((( 1835 -(% style="color: #4f81bd" %)**Step2**(%%)**: **Run AT Command to make LT work in Single frequency & ABP mode. Below is the AT commands:1912 +(% style="color:blue" %)**Step2**(%%)**: **Run AT Command to make LT work in Single frequency & ABP mode. Below is the AT commands: 1836 1836 ))) 1837 1837 1838 1838 ((( ... ... @@ -1856,20 +1856,28 @@ 1856 1856 [[image:1653360498588-932.png||height="485" width="726"]] 1857 1857 1858 1858 1936 + 1859 1859 == 5.4 Can I see counting event in Serial? == 1860 1860 1939 + 1861 1861 ((( 1862 -User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn ’t support AT+DEBUG. User can update to latest firmware first.1941 +User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn't support AT+DEBUG. User can update to latest firmware first. 1863 1863 1864 1864 1944 + 1865 1865 == 5.5 Can i use point to point communication for LT-22222-L? == 1866 1866 1947 + 1867 1867 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1949 + 1950 + 1951 + 1868 1868 ))) 1869 1869 1870 1870 ((( 1871 1871 == 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? == 1872 1872 1957 + 1873 1873 If the device is not shut down, but directly powered off. 1874 1874 1875 1875 It will default that this is a power-off state. ... ... @@ -1878,12 +1878,16 @@ 1878 1878 1879 1879 After restart, the status before power failure will be read from flash. 1880 1880 1966 + 1967 + 1881 1881 = 6. Trouble Shooting = 1882 1882 ))) 1883 1883 1884 1884 ((( 1885 1885 ((( 1886 -== 6.1 Downlink doesn’t work, how to solve it? == 1973 +== 6.1 Downlink doesn't work, how to solve it? == 1974 + 1975 + 1887 1887 ))) 1888 1888 ))) 1889 1889 ... ... @@ -1894,7 +1894,10 @@ 1894 1894 ((( 1895 1895 1896 1896 1986 + 1897 1897 == 6.2 Have trouble to upload image. == 1988 + 1989 + 1898 1898 ))) 1899 1899 1900 1900 ((( ... ... @@ -1904,7 +1904,10 @@ 1904 1904 ((( 1905 1905 1906 1906 1907 -== 6.3 Why I can’t join TTN in US915 /AU915 bands? == 1999 + 2000 +== 6.3 Why I can't join TTN in US915 /AU915 bands? == 2001 + 2002 + 1908 1908 ))) 1909 1909 1910 1910 ((( ... ... @@ -1918,19 +1918,21 @@ 1918 1918 1919 1919 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1920 1920 1921 - 1922 1922 (% style="color:#4f81bd" %)**XXX:** 1923 1923 1924 -* (% style="color: #4f81bd" %)**EU433**(%%): LT with frequency bands EU4331925 -* (% style="color: #4f81bd" %)**EU868**(%%): LT with frequency bands EU8681926 -* (% style="color: #4f81bd" %)**KR920**(%%): LT with frequency bands KR9201927 -* (% style="color: #4f81bd" %)**CN470**(%%): LT with frequency bands CN4701928 -* (% style="color: #4f81bd" %)**AS923**(%%): LT with frequency bands AS9231929 -* (% style="color: #4f81bd" %)**AU915**(%%): LT with frequency bands AU9151930 -* (% style="color: #4f81bd" %)**US915**(%%): LT with frequency bands US9151931 -* (% style="color: #4f81bd" %)**IN865**(%%): LT with frequency bands IN8651932 -* (% style="color: #4f81bd" %)**CN779**(%%): LT with frequency bands CN7792018 +* (% style="color:red" %)**EU433**(%%): LT with frequency bands EU433 2019 +* (% style="color:red" %)**EU868**(%%): LT with frequency bands EU868 2020 +* (% style="color:red" %)**KR920**(%%): LT with frequency bands KR920 2021 +* (% style="color:red" %)**CN470**(%%): LT with frequency bands CN470 2022 +* (% style="color:red" %)**AS923**(%%): LT with frequency bands AS923 2023 +* (% style="color:red" %)**AU915**(%%): LT with frequency bands AU915 2024 +* (% style="color:red" %)**US915**(%%): LT with frequency bands US915 2025 +* (% style="color:red" %)**IN865**(%%): LT with frequency bands IN865 2026 +* (% style="color:red" %)**CN779**(%%): LT with frequency bands CN779 1933 1933 2028 + 2029 + 2030 + 1934 1934 = 8. Packing Info = 1935 1935 1936 1936 ... ... @@ -1948,18 +1948,29 @@ 1948 1948 * Package Size / pcs : 14.5 x 8 x 5 cm 1949 1949 * Weight / pcs : 170g 1950 1950 2048 + 2049 + 2050 + 1951 1951 = 9. Support = 1952 1952 2053 + 1953 1953 * ((( 1954 1954 Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1955 1955 ))) 1956 1956 * ((( 1957 1957 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 2059 + 2060 + 2061 + 2062 + 2063 + 1958 1958 ))) 1959 1959 1960 1960 = 10. Reference = 1961 1961 2068 + 1962 1962 * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] 1963 -* [[Image Download>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]] 1964 -* [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 2070 +* [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]] 1965 1965 * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]] 2072 + 2073 +
- image-20220714135731-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +54.1 KB - Content
- image-20220719105525-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +165.5 KB - Content
- image-20220719110247-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +52.9 KB - Content