Last modified by Mengting Qiu on 2025/06/04 18:42

From version 82.30
edited by Xiaoling
on 2022/06/20 13:34
Change comment: There is no comment for this version
To version 82.38
edited by Xiaoling
on 2022/06/25 15:11
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -181,6 +181,10 @@
181 181  * Firmware upgradable via program port
182 182  * Counting
183 183  
184 +
185 +
186 +
187 +
184 184  == 1.4  Applications ==
185 185  
186 186  * Smart Buildings & Home Automation
... ... @@ -190,6 +190,10 @@
190 190  * Smart Cities
191 191  * Smart Factory
192 192  
197 +
198 +
199 +
200 +
193 193  == 1.5 Hardware Variants ==
194 194  
195 195  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -204,7 +204,6 @@
204 204  )))
205 205  
206 206  
207 -
208 208  = 2. Power ON Device =
209 209  
210 210  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -564,7 +564,6 @@
564 564  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
565 565  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
566 566  
567 -
568 568  (% style="color:#037691" %)**AT Command to set Trigger Condition**:
569 569  
570 570  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -747,26 +747,21 @@
747 747  
748 748  * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):**
749 749  
750 -(% class="box infomessage" %)
751 -(((
752 -**0x0A aa     ~/~/ Same as AT+MOD=aa**
753 -)))
756 +**0x0A aa    ** ~/~/ Same as AT+MOD=aa
754 754  
755 755  
756 756  
760 +
757 757  ==== 3.4.2.3 Poll an uplink ====
758 758  
759 -* (% style="color:#037691" %)AT Command:
763 +* (% style="color:#037691" %)**AT Command:**
760 760  
761 761  There is no AT Command to poll uplink
762 762  
763 763  
764 -* (% style="color:#037691" %)Downlink Payload (prefix 0x08):
768 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x08):**
765 765  
766 -(% class="box infomessage" %)
767 -(((
768 -**0x08 FF     ~/~/ Poll an uplink,**
769 -)))
770 +**0x08 FF     **~/~/ Poll an uplink
770 770  
771 771  **Example**: 0x08FF, ask device to send an Uplink
772 772  
... ... @@ -776,12 +776,9 @@
776 776  
777 777  Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
778 778  
779 -* (% style="color:#037691" %)AT Command:
780 +* (% style="color:#037691" %)**AT Command:**
780 780  
781 -(% class="box infomessage" %)
782 -(((
783 783  **AT+ADDMOD6=1 or 0**
784 -)))
785 785  
786 786  1: Enable Trigger Mode
787 787  
... ... @@ -788,38 +788,34 @@
788 788  0: Disable Trigger Mode
789 789  
790 790  
791 -* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06):
789 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):**
792 792  
793 -(% class="box infomessage" %)
794 -(((
795 -**0x0A 06 aa     ~/~/ Same as AT+ADDMOD6=aa,**
796 -)))
791 +**0x0A 06 aa    ** ~/~/ Same as AT+ADDMOD6=aa
797 797  
798 798  
799 799  
795 +
800 800  ==== 3.4.2.5 Poll trigger settings ====
801 801  
802 802  Poll trigger settings,
803 803  
804 -* (% style="color:#037691" %)AT Command:
800 +* (% style="color:#037691" %)**AT Command:**
805 805  
806 806  There is no AT Command for this feature.
807 807  
808 808  
809 -* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06):
805 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):**
810 810  
811 -(% class="box infomessage" %)
812 -(((
813 -**0xAB 06  ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command**
814 -)))
807 +**0xAB 06         **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command
815 815  
816 816  
817 817  
811 +
818 818  ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ====
819 819  
820 820  Enable Disable DI1/DI2/DI2 as trigger,
821 821  
822 -* (% style="color:#037691" %)AT Command:
816 +* (% style="color:#037691" %)**AT Command:**
823 823  
824 824  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
825 825  
... ... @@ -828,7 +828,7 @@
828 828  
829 829  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
830 830  
831 -* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02):
825 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):**
832 832  
833 833  **0xAA 02 aa bb        **~/~/ Same as AT+DTRI=aa,bb
834 834  
... ... @@ -839,7 +839,7 @@
839 839  
840 840  Set DI1 or DI3(for LT-33222-L) trigger.
841 841  
842 -* (% style="color:#037691" %)AT Command:
836 +* (% style="color:#037691" %)**AT Command:**
843 843  
844 844  **AT+TRIG1=a,b**
845 845  
... ... @@ -857,6 +857,7 @@
857 857  * **0x09 01 aa bb cc    ** ~/~/ same as AT+TRIG1=aa,0x(bb cc)
858 858  
859 859  
854 +
860 860  ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
861 861  
862 862  Set DI2 trigger.
... ... @@ -917,11 +917,11 @@
917 917  
918 918  ==== 3.4.2.11 Trigger – Set minimum interval ====
919 919  
920 -Set AV and AC trigger minimum interval, system wont response to the second trigger within this set time after the first trigger.
915 +Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger.
921 921  
922 922  * (% style="color:#037691" %)**AT Command**
923 923  
924 -**AT+ATDC=5. Device wont response the second trigger within 5 minute after the first trigger.**
919 +**AT+ATDC=5        ** Device won't response the second trigger within 5 minute after the first trigger.
925 925  
926 926  
927 927  * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )**
... ... @@ -1131,7 +1131,7 @@
1131 1131  
1132 1132  * (% style="color:#037691" %)**AT Command:**
1133 1133  
1134 -(% style="color:#037691" %)**​​​​​​​**(%%)**AT+SETCNT=aa,(bb cc dd ee) **
1129 +**AT+SETCNT=aa,(bb cc dd ee) **
1135 1135  
1136 1136  aa: 1: Set count1,
1137 1137  
... ... @@ -1155,7 +1155,7 @@
1155 1155  
1156 1156  * (% style="color:#037691" %)**AT Command:**
1157 1157  
1158 -(% style="color:#037691" %)​​​​​​​​​​​​​​(%%)**AT+CLRCOUNT ** ~/~/ clear all counting
1153 +**AT+CLRCOUNT ** ~/~/ clear all counting
1159 1159  
1160 1160  
1161 1161  * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):**
... ... @@ -1413,6 +1413,7 @@
1413 1413  [[image:image-20220524100748-11.png]]
1414 1414  
1415 1415  
1411 +
1416 1416  = 4. Use AT Command =
1417 1417  
1418 1418  == 4.1 Access AT Command ==
... ... @@ -1615,8 +1615,6 @@
1615 1615  
1616 1616  (((
1617 1617  AT+CFG: Print all settings
1618 -
1619 -
1620 1620  )))
1621 1621  
1622 1622  
... ... @@ -1662,8 +1662,6 @@
1662 1662  
1663 1663  (((
1664 1664  (% style="background-color:#dcdcdc" %)ATZ
1665 -
1666 -
1667 1667  )))
1668 1668  
1669 1669  
... ... @@ -1870,6 +1870,8 @@
1870 1870  == 5.5 Can i use point to point communication for LT-22222-L? ==
1871 1871  
1872 1872  Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]]
1865 +
1866 +
1873 1873  )))
1874 1874  
1875 1875  (((
... ... @@ -1883,6 +1883,7 @@
1883 1883  
1884 1884  After restart, the status before power failure will be read from flash.
1885 1885  
1880 +
1886 1886  = 6. Trouble Shooting =
1887 1887  )))
1888 1888  
... ... @@ -1936,6 +1936,8 @@
1936 1936  * (% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865
1937 1937  * (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779
1938 1938  
1934 +
1935 +
1939 1939  = 8. Packing Info =
1940 1940  
1941 1941  
... ... @@ -1953,6 +1953,8 @@
1953 1953  * Package Size / pcs : 14.5 x 8 x 5 cm
1954 1954  * Weight / pcs : 170g
1955 1955  
1953 +
1954 +
1956 1956  = 9. Support =
1957 1957  
1958 1958  * (((
... ... @@ -1960,6 +1960,10 @@
1960 1960  )))
1961 1961  * (((
1962 1962  Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
1962 +
1963 +
1964 +
1965 +
1963 1963  )))
1964 1964  