Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -747,26 +747,21 @@ 747 747 748 748 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 749 749 750 -(% class="box infomessage" %) 751 -((( 752 -**0x0A aa ~/~/ Same as AT+MOD=aa** 753 -))) 750 +**0x0A aa ** ~/~/ Same as AT+MOD=aa 754 754 755 755 756 756 754 + 757 757 ==== 3.4.2.3 Poll an uplink ==== 758 758 759 -* (% style="color:#037691" %)AT Command: 757 +* (% style="color:#037691" %)**AT Command:** 760 760 761 761 There is no AT Command to poll uplink 762 762 763 763 764 -* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 762 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x08):** 765 765 766 -(% class="box infomessage" %) 767 -((( 768 -**0x08 FF ~/~/ Poll an uplink,** 769 -))) 764 +**0x08 FF **~/~/ Poll an uplink 770 770 771 771 **Example**: 0x08FF, ask device to send an Uplink 772 772 ... ... @@ -776,12 +776,9 @@ 776 776 777 777 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 778 778 779 -* (% style="color:#037691" %)AT Command: 774 +* (% style="color:#037691" %)**AT Command:** 780 780 781 -(% class="box infomessage" %) 782 -((( 783 783 **AT+ADDMOD6=1 or 0** 784 -))) 785 785 786 786 1: Enable Trigger Mode 787 787 ... ... @@ -788,38 +788,34 @@ 788 788 0: Disable Trigger Mode 789 789 790 790 791 -* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 783 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):** 792 792 793 -(% class="box infomessage" %) 794 -((( 795 -**0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 796 -))) 785 +**0x0A 06 aa ** ~/~/ Same as AT+ADDMOD6=aa 797 797 798 798 799 799 789 + 800 800 ==== 3.4.2.5 Poll trigger settings ==== 801 801 802 802 Poll trigger settings, 803 803 804 -* (% style="color:#037691" %)AT Command: 794 +* (% style="color:#037691" %)**AT Command:** 805 805 806 806 There is no AT Command for this feature. 807 807 808 808 809 -* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 799 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):** 810 810 811 -(% class="box infomessage" %) 812 -((( 813 -**0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 814 -))) 801 +**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 815 815 816 816 817 817 805 + 818 818 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 819 819 820 820 Enable Disable DI1/DI2/DI2 as trigger, 821 821 822 -* (% style="color:#037691" %)AT Command: 810 +* (% style="color:#037691" %)**AT Command:** 823 823 824 824 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 825 825 ... ... @@ -828,7 +828,7 @@ 828 828 829 829 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 830 830 831 -* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 819 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):** 832 832 833 833 **0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 834 834 ... ... @@ -839,7 +839,7 @@ 839 839 840 840 Set DI1 or DI3(for LT-33222-L) trigger. 841 841 842 -* (% style="color:#037691" %)AT Command: 830 +* (% style="color:#037691" %)**AT Command:** 843 843 844 844 **AT+TRIG1=a,b** 845 845 ... ... @@ -857,6 +857,8 @@ 857 857 * **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 858 858 859 859 848 + 849 + 860 860 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 861 861 862 862 Set DI2 trigger. ... ... @@ -917,11 +917,11 @@ 917 917 918 918 ==== 3.4.2.11 Trigger – Set minimum interval ==== 919 919 920 -Set AV and AC trigger minimum interval, system won ’t response to the second trigger within this set time after the first trigger.910 +Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger. 921 921 922 922 * (% style="color:#037691" %)**AT Command** 923 923 924 -**AT+ATDC=5 .Device won’t response the second trigger within 5 minute after the first trigger.**914 +**AT+ATDC=5 ** Device won't response the second trigger within 5 minute after the first trigger. 925 925 926 926 927 927 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** ... ... @@ -1131,7 +1131,7 @@ 1131 1131 1132 1132 * (% style="color:#037691" %)**AT Command:** 1133 1133 1134 - (% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) **1124 +**AT+SETCNT=aa,(bb cc dd ee) ** 1135 1135 1136 1136 aa: 1: Set count1, 1137 1137 ... ... @@ -1155,7 +1155,7 @@ 1155 1155 1156 1156 * (% style="color:#037691" %)**AT Command:** 1157 1157 1158 -(% style="color:#037691" %) (%%)**AT+CLRCOUNT ** ~/~/ clear all counting1148 +(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1159 1159 1160 1160 1161 1161 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** ... ... @@ -1413,6 +1413,7 @@ 1413 1413 [[image:image-20220524100748-11.png]] 1414 1414 1415 1415 1406 + 1416 1416 = 4. Use AT Command = 1417 1417 1418 1418 == 4.1 Access AT Command == ... ... @@ -1615,8 +1615,6 @@ 1615 1615 1616 1616 ((( 1617 1617 AT+CFG: Print all settings 1618 - 1619 - 1620 1620 ))) 1621 1621 1622 1622 ... ... @@ -1662,8 +1662,6 @@ 1662 1662 1663 1663 ((( 1664 1664 (% style="background-color:#dcdcdc" %)ATZ 1665 - 1666 - 1667 1667 ))) 1668 1668 1669 1669 ... ... @@ -1870,6 +1870,8 @@ 1870 1870 == 5.5 Can i use point to point communication for LT-22222-L? == 1871 1871 1872 1872 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1860 + 1861 + 1873 1873 ))) 1874 1874 1875 1875 ((( ... ... @@ -1883,6 +1883,7 @@ 1883 1883 1884 1884 After restart, the status before power failure will be read from flash. 1885 1885 1875 + 1886 1886 = 6. Trouble Shooting = 1887 1887 ))) 1888 1888 ... ... @@ -1936,6 +1936,9 @@ 1936 1936 * (% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865 1937 1937 * (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779 1938 1938 1929 + 1930 + 1931 + 1939 1939 = 8. Packing Info = 1940 1940 1941 1941 ... ... @@ -1953,6 +1953,9 @@ 1953 1953 * Package Size / pcs : 14.5 x 8 x 5 cm 1954 1954 * Weight / pcs : 170g 1955 1955 1949 + 1950 + 1951 + 1956 1956 = 9. Support = 1957 1957 1958 1958 * ((( ... ... @@ -1960,6 +1960,10 @@ 1960 1960 ))) 1961 1961 * ((( 1962 1962 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1959 + 1960 + 1961 + 1962 + 1963 1963 ))) 1964 1964 1965 1965 = 10. Reference =