From version < 82.30 >
edited by Xiaoling
on 2022/06/20 13:34
To version < 82.20 >
edited by Xiaoling
on 2022/06/20 11:54
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -181,6 +181,8 @@
181 181  * Firmware upgradable via program port
182 182  * Counting
183 183  
184 +
185 +
184 184  == 1.4  Applications ==
185 185  
186 186  * Smart Buildings & Home Automation
... ... @@ -190,6 +190,8 @@
190 190  * Smart Cities
191 191  * Smart Factory
192 192  
195 +
196 +
193 193  == 1.5 Hardware Variants ==
194 194  
195 195  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -204,7 +204,6 @@
204 204  )))
205 205  
206 206  
207 -
208 208  = 2. Power ON Device =
209 209  
210 210  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -285,6 +285,8 @@
285 285  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
286 286  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
287 287  
291 +
292 +
288 288  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
289 289  
290 290  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -338,6 +338,8 @@
338 338  ** DO1 is high in case there is load between DO1 and V+.
339 339  ** DO1 LED is off in both case
340 340  
346 +
347 +
341 341  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
342 342  
343 343  
... ... @@ -387,20 +387,24 @@
387 387  
388 388  (((
389 389  **For LT22222-L:**
397 +)))
390 390  
399 +(% class="box infomessage" %)
400 +(((
401 +(((
402 +**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) **
391 391  
392 -(% style="color:blue" %)**AT+TRIG1=0,100**(%%)**  (set DI1 port to trigger on low level, valid signal is 100ms) **
404 +**AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) **
393 393  
394 -(% style="color:blue" %)**AT+TRIG1=1,100**(%%)**  (set DI1 port to trigger on high level, valid signal is 100ms ) **
406 +**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) **
395 395  
396 -(% style="color:blue" %)**AT+TRIG2=0,100**(%%)**  (set DI2 port to trigger on low level, valid signal is 100ms) **
408 +**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) **
397 397  
398 -(% style="color:blue" %)**AT+TRIG2=1,100**(%%)**  (set DI2 port to trigger on high level, valid signal is 100ms ) **
410 +**AT+SETCNT=1,6  (Set COUNT1 value to 60)**
399 399  
400 -(% style="color:blue" %)**AT+SETCNT=1,60**(%%)**   (Set COUNT1 value to 60)**
401 -
402 -(% style="color:blue" %)**AT+SETCNT=2,60**(%%)**   (Set COUNT2 value to 60)**
412 +**AT+SETCNT=2,60   (Set COUNT2 value to 60)**
403 403  )))
414 +)))
404 404  
405 405  
406 406  
... ... @@ -492,19 +492,22 @@
492 492  
493 493  
494 494  **Plus below command for AVI1 Counting:**
506 +)))
495 495  
508 +(% class="box infomessage" %)
509 +(((
510 +(((
511 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)**   (set AVI Count to 60)**
496 496  
497 -(% style="color:blue" %)**AT+SETCNT=3,60**(%%)**  (set AVI Count to 60)**
513 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)**   (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)**
498 498  
499 -(% style="color:blue" %)**AT+VOLMAX=20000**(%%)**  (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)**
515 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)**   (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)**
500 500  
501 -(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)**  (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)**
502 -
503 -(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)**  (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)**
517 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)**   (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)**
504 504  )))
519 +)))
505 505  
506 506  
507 -
508 508  === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI ===
509 509  
510 510  
... ... @@ -564,7 +564,6 @@
564 564  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
565 565  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
566 566  
567 -
568 568  (% style="color:#037691" %)**AT Command to set Trigger Condition**:
569 569  
570 570  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -706,6 +706,8 @@
706 706  
707 707  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
708 708  
722 +
723 +
709 709  === 3.4.1 Common Commands ===
710 710  
711 711  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -720,19 +720,23 @@
720 720  
721 721  * (% style="color:#037691" %)**AT Command:**
722 722  
738 +(% class="box infomessage" %)
739 +(((
723 723  **AT+TDC=N **
741 +)))
724 724  
725 -
726 726  **Example: **AT+TDC=30000. Means set interval to 30 seconds
727 727  
728 728  
729 729  * (% style="color:#037691" %)**Downlink Payload (prefix 0x01):**
730 730  
748 +(% class="box infomessage" %)
749 +(((
731 731  **0x01 aa bb cc     ~/~/ Same as AT+TDC=0x(aa bb cc)**
751 +)))
732 732  
733 733  
734 734  
735 -
736 736  ==== 3.4.2.2 Set Work Mode (AT+MOD) ====
737 737  
738 738  Set work mode.
... ... @@ -739,9 +739,11 @@
739 739  
740 740  * (% style="color:#037691" %)**AT Command:**
741 741  
761 +(% class="box infomessage" %)
762 +(((
742 742  **AT+MOD=N  **
764 +)))
743 743  
744 -
745 745  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
746 746  
747 747  
... ... @@ -821,7 +821,10 @@
821 821  
822 822  * (% style="color:#037691" %)AT Command:
823 823  
845 +(% class="box infomessage" %)
846 +(((
824 824  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
848 +)))
825 825  
826 826  
827 827  **Example:**
... ... @@ -830,7 +830,7 @@
830 830  
831 831  * (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02):
832 832  
833 -**0xAA 02 aa bb        **~/~/ Same as AT+DTRI=aa,bb
857 +**0xAA 02 aa bb  **~/~/ Same as AT+DTRI=aa,bb
834 834  
835 835  
836 836  
... ... @@ -854,9 +854,11 @@
854 854  
855 855  
856 856  * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):**
857 -* **0x09 01 aa bb cc    ** ~/~/ same as AT+TRIG1=aa,0x(bb cc)
881 +* **0x09 01 aa bb cc  ** ~/~/ same as AT+TRIG1=aa,0x(bb cc)
858 858  
859 859  
884 +
885 +
860 860  ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
861 861  
862 862  Set DI2 trigger.
... ... @@ -878,7 +878,7 @@
878 878  
879 879  * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):**
880 880  
881 -**0x09 02 aa bb cc           **~/~/ same as AT+TRIG1=aa,0x(bb cc)
907 +**0x09 02 aa bb cc  **~/~/ same as AT+TRIG1=aa,0x(bb cc)
882 882  
883 883  
884 884  
... ... @@ -894,7 +894,7 @@
894 894  
895 895  * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )**
896 896  
897 -**0x AA 01 aa bb cc dd ee ff gg hh        ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
923 +**0x AA 01 aa bb cc dd ee ff gg hh  ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
898 898  
899 899  
900 900  
... ... @@ -910,7 +910,7 @@
910 910  
911 911  * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )**
912 912  
913 -**0x AA 00 aa bb cc dd ee ff gg hh    ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
939 +**0x AA 00 aa bb cc dd ee ff gg hh  ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
914 914  
915 915  
916 916  
... ... @@ -926,7 +926,7 @@
926 926  
927 927  * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )**
928 928  
929 -**0x AC aa bb   ** ~/~/ same as AT+ATDC=0x(aa bb)   . Unit (min)
955 +**0x AC aa bb  ** ~/~/ same as AT+ATDC=0x(aa bb)   . Unit (min)
930 930  
931 931  
932 932  
... ... @@ -941,6 +941,7 @@
941 941  * (% style="color:#037691" %)**Downlink Payload (prefix 0x02)**
942 942  * **0x02 aa bb cc     **~/~/ Set DO1/DO2/DO3 output
943 943  
970 +
944 944  (((
945 945  If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low.
946 946  )))
... ... @@ -1117,7 +1117,7 @@
1117 1117  
1118 1118  * (% style="color:#037691" %)**AT Command:**
1119 1119  
1120 -**AT+VOLMAX   ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1147 +(% style="color:#037691" %)**​​​​​​​**(%%)**AT+VOLMAX   ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1121 1121  
1122 1122  
1123 1123  * (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):**
... ... @@ -1131,7 +1131,7 @@
1131 1131  
1132 1132  * (% style="color:#037691" %)**AT Command:**
1133 1133  
1134 -(% style="color:#037691" %)**​​​​​​​**(%%)**AT+SETCNT=aa,(bb cc dd ee) **
1161 +(% style="color:#037691" %)**​​​​​​​​​​​​​​**(%%)**AT+SETCNT=aa,(bb cc dd ee) **
1135 1135  
1136 1136  aa: 1: Set count1,
1137 1137  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0