Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,7 +1,6 @@ 1 1 (% style="text-align:center" %) 2 2 [[image:image-20220523163353-1.jpeg||height="604" width="500"]] 3 3 4 -**LT-22222-L LoRa IO Controller User Manual ** 5 5 6 6 7 7 **Table of Contents:** ... ... @@ -167,7 +167,6 @@ 167 167 Packet engine up to 256 bytes with CRC. 168 168 169 169 170 - 171 171 172 172 ))) 173 173 ... ... @@ -181,6 +181,7 @@ 181 181 * Firmware upgradable via program port 182 182 * Counting 183 183 182 + 184 184 == 1.4 Applications == 185 185 186 186 * Smart Buildings & Home Automation ... ... @@ -190,6 +190,7 @@ 190 190 * Smart Cities 191 191 * Smart Factory 192 192 192 + 193 193 == 1.5 Hardware Variants == 194 194 195 195 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -204,7 +204,6 @@ 204 204 ))) 205 205 206 206 207 - 208 208 = 2. Power ON Device = 209 209 210 210 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -222,11 +222,11 @@ 222 222 == 3.1 How it works? == 223 223 224 224 ((( 225 -The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on **TX LED** will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. **TX LED** will be on for 5 seconds after joined in network. When there is message from server, the **RX LED**will be on for 1 second.224 +The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%) will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. (% style="color:green" %)**TX LED**(%%) will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second. 226 226 ))) 227 227 228 228 ((( 229 -In case user can ’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.228 +In case user can't set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 230 230 ))) 231 231 232 232 ... ... @@ -278,13 +278,15 @@ 278 278 279 279 There are five working modes + one interrupt mode on LT for different type application: 280 280 281 -* **MOD1**: (default setting): 2 x ACI + 2AVI + DI + DO + RO 282 -* **MOD2**: Double DI Counting + DO + RO 283 -* **MOD3**: Single DI Counting + 2 x ACI + DO + RO 284 -* **MOD4**: Single DI Counting + 1 x Voltage Counting + DO + RO 285 -* **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 286 -* **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 280 +* **(% style="color:blue" %)MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO 281 +* **(% style="color:blue" %)MOD2**(%%): Double DI Counting + DO + RO 282 +* **(% style="color:blue" %)MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO 283 +* **(% style="color:blue" %)MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO 284 +* **(% style="color:blue" %)MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 285 +* **(% style="color:blue" %)ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5 287 287 287 + 288 + 288 288 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 289 289 290 290 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -564,7 +564,6 @@ 564 564 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 565 565 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 566 566 567 - 568 568 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 569 569 570 570 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -730,10 +730,6 @@ 730 730 731 731 **0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 732 732 733 -(% class="box infomessage" %) 734 -((( 735 - 736 -))) 737 737 738 738 739 739 ... ... @@ -743,36 +743,29 @@ 743 743 744 744 * (% style="color:#037691" %)**AT Command:** 745 745 746 -(% class="box infomessage" %) 747 -((( 748 748 **AT+MOD=N ** 749 -))) 750 750 744 + 751 751 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 752 752 753 753 754 754 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 755 755 756 -(% class="box infomessage" %) 757 -((( 758 -**0x0A aa ~/~/ Same as AT+MOD=aa** 759 -))) 750 +**0x0A aa ** ~/~/ Same as AT+MOD=aa 760 760 761 761 762 762 754 + 763 763 ==== 3.4.2.3 Poll an uplink ==== 764 764 765 -* (% style="color:#037691" %)AT Command: 757 +* (% style="color:#037691" %)**AT Command:** 766 766 767 767 There is no AT Command to poll uplink 768 768 769 769 770 -* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 762 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x08):** 771 771 772 -(% class="box infomessage" %) 773 -((( 774 -**0x08 FF ~/~/ Poll an uplink,** 775 -))) 764 +**0x08 FF **~/~/ Poll an uplink 776 776 777 777 **Example**: 0x08FF, ask device to send an Uplink 778 778 ... ... @@ -782,12 +782,9 @@ 782 782 783 783 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 784 784 785 -* (% style="color:#037691" %)AT Command: 774 +* (% style="color:#037691" %)**AT Command:** 786 786 787 -(% class="box infomessage" %) 788 -((( 789 789 **AT+ADDMOD6=1 or 0** 790 -))) 791 791 792 792 1: Enable Trigger Mode 793 793 ... ... @@ -794,38 +794,34 @@ 794 794 0: Disable Trigger Mode 795 795 796 796 797 -* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 783 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):** 798 798 799 -(% class="box infomessage" %) 800 -((( 801 -**0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 802 -))) 785 +**0x0A 06 aa ** ~/~/ Same as AT+ADDMOD6=aa 803 803 804 804 805 805 789 + 806 806 ==== 3.4.2.5 Poll trigger settings ==== 807 807 808 808 Poll trigger settings, 809 809 810 -* (% style="color:#037691" %)AT Command: 794 +* (% style="color:#037691" %)**AT Command:** 811 811 812 812 There is no AT Command for this feature. 813 813 814 814 815 -* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 799 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):** 816 816 817 -(% class="box infomessage" %) 818 -((( 819 -**0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 820 -))) 801 +**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 821 821 822 822 823 823 805 + 824 824 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 825 825 826 826 Enable Disable DI1/DI2/DI2 as trigger, 827 827 828 -* (% style="color:#037691" %)AT Command: 810 +* (% style="color:#037691" %)**AT Command:** 829 829 830 830 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 831 831 ... ... @@ -834,7 +834,7 @@ 834 834 835 835 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 836 836 837 -* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 819 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):** 838 838 839 839 **0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 840 840 ... ... @@ -845,7 +845,7 @@ 845 845 846 846 Set DI1 or DI3(for LT-33222-L) trigger. 847 847 848 -* (% style="color:#037691" %)AT Command: 830 +* (% style="color:#037691" %)**AT Command:** 849 849 850 850 **AT+TRIG1=a,b** 851 851 ... ... @@ -862,7 +862,6 @@ 862 862 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 863 863 * **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 864 864 865 - 866 866 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 867 867 868 868 Set DI2 trigger. ... ... @@ -923,11 +923,11 @@ 923 923 924 924 ==== 3.4.2.11 Trigger – Set minimum interval ==== 925 925 926 -Set AV and AC trigger minimum interval, system won ’t response to the second trigger within this set time after the first trigger.907 +Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger. 927 927 928 928 * (% style="color:#037691" %)**AT Command** 929 929 930 -**AT+ATDC=5 .Device won’t response the second trigger within 5 minute after the first trigger.**911 +**AT+ATDC=5 ** Device won't response the second trigger within 5 minute after the first trigger. 931 931 932 932 933 933 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** ... ... @@ -934,9 +934,14 @@ 934 934 935 935 **0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 936 936 918 +((( 919 + 937 937 921 +(% style="color:red" %)Note: ATDC setting must be more than 5min 922 +))) 938 938 939 939 925 + 940 940 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 941 941 942 942 * (% style="color:#037691" %)**AT Command** ... ... @@ -1137,7 +1137,7 @@ 1137 1137 1138 1138 * (% style="color:#037691" %)**AT Command:** 1139 1139 1140 - (% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) **1126 +**AT+SETCNT=aa,(bb cc dd ee) ** 1141 1141 1142 1142 aa: 1: Set count1, 1143 1143 ... ... @@ -1161,7 +1161,7 @@ 1161 1161 1162 1162 * (% style="color:#037691" %)**AT Command:** 1163 1163 1164 - (% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting1150 +**AT+CLRCOUNT ** ~/~/ clear all counting 1165 1165 1166 1166 1167 1167 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** ... ... @@ -1419,6 +1419,7 @@ 1419 1419 [[image:image-20220524100748-11.png]] 1420 1420 1421 1421 1408 + 1422 1422 = 4. Use AT Command = 1423 1423 1424 1424 == 4.1 Access AT Command == ... ... @@ -1621,8 +1621,6 @@ 1621 1621 1622 1622 ((( 1623 1623 AT+CFG: Print all settings 1624 - 1625 - 1626 1626 ))) 1627 1627 1628 1628 ... ... @@ -1668,8 +1668,6 @@ 1668 1668 1669 1669 ((( 1670 1670 (% style="background-color:#dcdcdc" %)ATZ 1671 - 1672 - 1673 1673 ))) 1674 1674 1675 1675 ... ... @@ -1876,6 +1876,8 @@ 1876 1876 == 5.5 Can i use point to point communication for LT-22222-L? == 1877 1877 1878 1878 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1862 + 1863 + 1879 1879 ))) 1880 1880 1881 1881 ((( ... ... @@ -1889,6 +1889,7 @@ 1889 1889 1890 1890 After restart, the status before power failure will be read from flash. 1891 1891 1877 + 1892 1892 = 6. Trouble Shooting = 1893 1893 ))) 1894 1894 ... ... @@ -1923,10 +1923,8 @@ 1923 1923 ))) 1924 1924 1925 1925 1926 - 1927 1927 = 7. Order Info = 1928 1928 1929 - 1930 1930 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1931 1931 1932 1932 ... ... @@ -1966,6 +1966,10 @@ 1966 1966 ))) 1967 1967 * ((( 1968 1968 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1953 + 1954 + 1955 + 1956 + 1969 1969 ))) 1970 1970 1971 1971 = 10. Reference =