Last modified by Mengting Qiu on 2025/06/04 18:42

From version 82.29
edited by Xiaoling
on 2022/06/20 13:34
Change comment: There is no comment for this version
To version 82.38
edited by Xiaoling
on 2022/06/25 15:11
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -181,6 +181,10 @@
181 181  * Firmware upgradable via program port
182 182  * Counting
183 183  
184 +
185 +
186 +
187 +
184 184  == 1.4  Applications ==
185 185  
186 186  * Smart Buildings & Home Automation
... ... @@ -190,6 +190,10 @@
190 190  * Smart Cities
191 191  * Smart Factory
192 192  
197 +
198 +
199 +
200 +
193 193  == 1.5 Hardware Variants ==
194 194  
195 195  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -204,7 +204,6 @@
204 204  )))
205 205  
206 206  
207 -
208 208  = 2. Power ON Device =
209 209  
210 210  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -564,7 +564,6 @@
564 564  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
565 565  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
566 566  
567 -
568 568  (% style="color:#037691" %)**AT Command to set Trigger Condition**:
569 569  
570 570  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -730,10 +730,6 @@
730 730  
731 731  **0x01 aa bb cc     ~/~/ Same as AT+TDC=0x(aa bb cc)**
732 732  
733 -(% class="box infomessage" %)
734 -(((
735 -
736 -)))
737 737  
738 738  
739 739  
... ... @@ -743,36 +743,29 @@
743 743  
744 744  * (% style="color:#037691" %)**AT Command:**
745 745  
746 -(% class="box infomessage" %)
747 -(((
748 748  **AT+MOD=N  **
749 -)))
750 750  
750 +
751 751  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
752 752  
753 753  
754 754  * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):**
755 755  
756 -(% class="box infomessage" %)
757 -(((
758 -**0x0A aa     ~/~/ Same as AT+MOD=aa**
759 -)))
756 +**0x0A aa    ** ~/~/ Same as AT+MOD=aa
760 760  
761 761  
762 762  
760 +
763 763  ==== 3.4.2.3 Poll an uplink ====
764 764  
765 -* (% style="color:#037691" %)AT Command:
763 +* (% style="color:#037691" %)**AT Command:**
766 766  
767 767  There is no AT Command to poll uplink
768 768  
769 769  
770 -* (% style="color:#037691" %)Downlink Payload (prefix 0x08):
768 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x08):**
771 771  
772 -(% class="box infomessage" %)
773 -(((
774 -**0x08 FF     ~/~/ Poll an uplink,**
775 -)))
770 +**0x08 FF     **~/~/ Poll an uplink
776 776  
777 777  **Example**: 0x08FF, ask device to send an Uplink
778 778  
... ... @@ -782,12 +782,9 @@
782 782  
783 783  Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
784 784  
785 -* (% style="color:#037691" %)AT Command:
780 +* (% style="color:#037691" %)**AT Command:**
786 786  
787 -(% class="box infomessage" %)
788 -(((
789 789  **AT+ADDMOD6=1 or 0**
790 -)))
791 791  
792 792  1: Enable Trigger Mode
793 793  
... ... @@ -794,38 +794,34 @@
794 794  0: Disable Trigger Mode
795 795  
796 796  
797 -* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06):
789 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):**
798 798  
799 -(% class="box infomessage" %)
800 -(((
801 -**0x0A 06 aa     ~/~/ Same as AT+ADDMOD6=aa,**
802 -)))
791 +**0x0A 06 aa    ** ~/~/ Same as AT+ADDMOD6=aa
803 803  
804 804  
805 805  
795 +
806 806  ==== 3.4.2.5 Poll trigger settings ====
807 807  
808 808  Poll trigger settings,
809 809  
810 -* (% style="color:#037691" %)AT Command:
800 +* (% style="color:#037691" %)**AT Command:**
811 811  
812 812  There is no AT Command for this feature.
813 813  
814 814  
815 -* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06):
805 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):**
816 816  
817 -(% class="box infomessage" %)
818 -(((
819 -**0xAB 06  ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command**
820 -)))
807 +**0xAB 06         **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command
821 821  
822 822  
823 823  
811 +
824 824  ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ====
825 825  
826 826  Enable Disable DI1/DI2/DI2 as trigger,
827 827  
828 -* (% style="color:#037691" %)AT Command:
816 +* (% style="color:#037691" %)**AT Command:**
829 829  
830 830  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
831 831  
... ... @@ -834,7 +834,7 @@
834 834  
835 835  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
836 836  
837 -* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02):
825 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):**
838 838  
839 839  **0xAA 02 aa bb        **~/~/ Same as AT+DTRI=aa,bb
840 840  
... ... @@ -845,7 +845,7 @@
845 845  
846 846  Set DI1 or DI3(for LT-33222-L) trigger.
847 847  
848 -* (% style="color:#037691" %)AT Command:
836 +* (% style="color:#037691" %)**AT Command:**
849 849  
850 850  **AT+TRIG1=a,b**
851 851  
... ... @@ -863,6 +863,7 @@
863 863  * **0x09 01 aa bb cc    ** ~/~/ same as AT+TRIG1=aa,0x(bb cc)
864 864  
865 865  
854 +
866 866  ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
867 867  
868 868  Set DI2 trigger.
... ... @@ -923,11 +923,11 @@
923 923  
924 924  ==== 3.4.2.11 Trigger – Set minimum interval ====
925 925  
926 -Set AV and AC trigger minimum interval, system wont response to the second trigger within this set time after the first trigger.
915 +Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger.
927 927  
928 928  * (% style="color:#037691" %)**AT Command**
929 929  
930 -**AT+ATDC=5. Device wont response the second trigger within 5 minute after the first trigger.**
919 +**AT+ATDC=5        ** Device won't response the second trigger within 5 minute after the first trigger.
931 931  
932 932  
933 933  * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )**
... ... @@ -1137,7 +1137,7 @@
1137 1137  
1138 1138  * (% style="color:#037691" %)**AT Command:**
1139 1139  
1140 -(% style="color:#037691" %)**​​​​​​​**(%%)**AT+SETCNT=aa,(bb cc dd ee) **
1129 +**AT+SETCNT=aa,(bb cc dd ee) **
1141 1141  
1142 1142  aa: 1: Set count1,
1143 1143  
... ... @@ -1161,7 +1161,7 @@
1161 1161  
1162 1162  * (% style="color:#037691" %)**AT Command:**
1163 1163  
1164 -(% style="color:#037691" %)​​​​​​​​​​​​​​(%%)**AT+CLRCOUNT ** ~/~/ clear all counting
1153 +**AT+CLRCOUNT ** ~/~/ clear all counting
1165 1165  
1166 1166  
1167 1167  * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):**
... ... @@ -1419,6 +1419,7 @@
1419 1419  [[image:image-20220524100748-11.png]]
1420 1420  
1421 1421  
1411 +
1422 1422  = 4. Use AT Command =
1423 1423  
1424 1424  == 4.1 Access AT Command ==
... ... @@ -1621,8 +1621,6 @@
1621 1621  
1622 1622  (((
1623 1623  AT+CFG: Print all settings
1624 -
1625 -
1626 1626  )))
1627 1627  
1628 1628  
... ... @@ -1668,8 +1668,6 @@
1668 1668  
1669 1669  (((
1670 1670  (% style="background-color:#dcdcdc" %)ATZ
1671 -
1672 -
1673 1673  )))
1674 1674  
1675 1675  
... ... @@ -1876,6 +1876,8 @@
1876 1876  == 5.5 Can i use point to point communication for LT-22222-L? ==
1877 1877  
1878 1878  Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]]
1865 +
1866 +
1879 1879  )))
1880 1880  
1881 1881  (((
... ... @@ -1889,6 +1889,7 @@
1889 1889  
1890 1890  After restart, the status before power failure will be read from flash.
1891 1891  
1880 +
1892 1892  = 6. Trouble Shooting =
1893 1893  )))
1894 1894  
... ... @@ -1942,6 +1942,8 @@
1942 1942  * (% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865
1943 1943  * (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779
1944 1944  
1934 +
1935 +
1945 1945  = 8. Packing Info =
1946 1946  
1947 1947  
... ... @@ -1959,6 +1959,8 @@
1959 1959  * Package Size / pcs : 14.5 x 8 x 5 cm
1960 1960  * Weight / pcs : 170g
1961 1961  
1953 +
1954 +
1962 1962  = 9. Support =
1963 1963  
1964 1964  * (((
... ... @@ -1966,6 +1966,10 @@
1966 1966  )))
1967 1967  * (((
1968 1968  Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
1962 +
1963 +
1964 +
1965 +
1969 1969  )))
1970 1970  
1971 1971  = 10. Reference​​​​​ =