Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -181,6 +181,8 @@ 181 181 * Firmware upgradable via program port 182 182 * Counting 183 183 184 + 185 + 184 184 == 1.4 Applications == 185 185 186 186 * Smart Buildings & Home Automation ... ... @@ -190,6 +190,8 @@ 190 190 * Smart Cities 191 191 * Smart Factory 192 192 195 + 196 + 193 193 == 1.5 Hardware Variants == 194 194 195 195 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -204,7 +204,6 @@ 204 204 ))) 205 205 206 206 207 - 208 208 = 2. Power ON Device = 209 209 210 210 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -285,6 +285,8 @@ 285 285 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 286 286 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 287 287 291 + 292 + 288 288 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 289 289 290 290 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -338,6 +338,8 @@ 338 338 ** DO1 is high in case there is load between DO1 and V+. 339 339 ** DO1 LED is off in both case 340 340 346 + 347 + 341 341 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 342 342 343 343 ... ... @@ -387,20 +387,24 @@ 387 387 388 388 ((( 389 389 **For LT22222-L:** 397 +))) 390 390 399 +(% class="box infomessage" %) 400 +((( 401 +((( 402 +**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 391 391 392 - (% style="color:blue" %)**AT+TRIG1=0,100**(%%)** (set DI1 port to trigger onlowlevel, valid signal is 100ms) **404 +**AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 393 393 394 - (% style="color:blue" %)**AT+TRIG1=1,100**(%%)**1port to trigger onhighlevel, valid signal is 100ms406 +**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 395 395 396 - (% style="color:blue" %)**AT+TRIG2=0,100**(%%)**lowlevel, valid signal is 100ms) **408 +**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 397 397 398 - (% style="color:blue" %)**AT+TRIG2=1,100**(%%)**setDI2port to trigger on high level, validsignalis 100ms)410 +**AT+SETCNT=1,60 (Set COUNT1 value to 60)** 399 399 400 -(% style="color:blue" %)**AT+SETCNT=1,60**(%%)** (Set COUNT1 value to 60)** 401 - 402 -(% style="color:blue" %)**AT+SETCNT=2,60**(%%)** (Set COUNT2 value to 60)** 412 +**AT+SETCNT=2,60 (Set COUNT2 value to 60)** 403 403 ))) 414 +))) 404 404 405 405 406 406 ... ... @@ -492,19 +492,22 @@ 492 492 493 493 494 494 **Plus below command for AVI1 Counting:** 506 +))) 495 495 508 +(% class="box infomessage" %) 509 +((( 510 +((( 511 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 496 496 497 -(% style="color:blue" %)**AT+ SETCNT=3,60**(%%)**(set AVICountto60)**513 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 498 498 499 -(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** higher than VOLMAX (20000mV =20v), counter increase 1)**515 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 500 500 501 -(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 502 - 503 -(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 517 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 504 504 ))) 519 +))) 505 505 506 506 507 - 508 508 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 509 509 510 510 ... ... @@ -564,7 +564,6 @@ 564 564 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 565 565 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 566 566 567 - 568 568 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 569 569 570 570 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -706,6 +706,8 @@ 706 706 707 707 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 708 708 722 + 723 + 709 709 === 3.4.1 Common Commands === 710 710 711 711 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -827,7 +827,10 @@ 827 827 828 828 * (% style="color:#037691" %)AT Command: 829 829 845 +(% class="box infomessage" %) 846 +((( 830 830 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 848 +))) 831 831 832 832 833 833 **Example:** ... ... @@ -836,11 +836,13 @@ 836 836 837 837 * (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 838 838 839 -**0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 857 +(% class="box infomessage" %) 858 +((( 859 +**0xAA 02 aa bb ~/~/ Same as AT+DTRI=aa,bb** 860 +))) 840 840 841 841 842 842 843 - 844 844 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 845 845 846 846 Set DI1 or DI3(for LT-33222-L) trigger. ... ... @@ -847,7 +847,10 @@ 847 847 848 848 * (% style="color:#037691" %)AT Command: 849 849 870 +(% class="box infomessage" %) 871 +((( 850 850 **AT+TRIG1=a,b** 873 +))) 851 851 852 852 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 853 853 ... ... @@ -859,19 +859,26 @@ 859 859 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 860 860 861 861 862 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 863 -* **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 885 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 01 ): 864 864 887 +(% class="box infomessage" %) 888 +((( 889 +**0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 890 +))) 865 865 892 + 893 + 866 866 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 867 867 868 868 Set DI2 trigger. 869 869 870 -* (% style="color:#037691" %) **AT Command:**898 +* (% style="color:#037691" %)AT Command: 871 871 900 +(% class="box infomessage" %) 901 +((( 872 872 **AT+TRIG2=a,b** 903 +))) 873 873 874 - 875 875 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 876 876 877 877 b : delay timing. ... ... @@ -882,72 +882,93 @@ 882 882 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 883 883 884 884 885 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x09 02 ):**915 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 02 ): 886 886 887 -**0x09 02 aa bb cc **~/~/ same as AT+TRIG1=aa,0x(bb cc) 917 +(% class="box infomessage" %) 918 +((( 919 +**0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 920 +))) 888 888 889 889 890 890 891 - 892 892 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 893 893 894 894 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 895 895 896 -* (% style="color:#037691" %) **AT Command**928 +* (% style="color:#037691" %)AT Command: 897 897 898 -**AT+ACLIM** 930 +(% class="box infomessage" %) 931 +((( 932 +**AT+ACLIM. ** 933 +))) 899 899 900 900 901 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAA 01 )**936 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 01 ): 902 902 903 -**0x AA 01 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 938 +(% class="box infomessage" %) 939 +((( 940 +**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 941 +))) 904 904 905 905 906 906 907 - 908 908 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 909 909 910 910 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 911 911 912 -* (% style="color:#037691" %) **AT Command**949 +* (% style="color:#037691" %)AT Command: 913 913 914 -**AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 951 +(% class="box infomessage" %) 952 +((( 953 +**AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 954 +))) 915 915 916 916 917 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAA 00 )**957 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 00 ): 918 918 919 -**0x AA 00 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 959 +(% class="box infomessage" %) 960 +((( 961 +**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ** 962 +))) 920 920 921 921 922 922 923 - 924 924 ==== 3.4.2.11 Trigger – Set minimum interval ==== 925 925 926 926 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 927 927 928 -* (% style="color:#037691" %) **AT Command**970 +* (% style="color:#037691" %)AT Command: 929 929 972 +(% class="box infomessage" %) 973 +((( 930 930 **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.** 975 +))) 931 931 932 932 933 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAC )**978 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAC ): 934 934 935 -**0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 980 +(% class="box infomessage" %) 981 +((( 982 +**0x AC aa bb ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min)** 983 +))) 936 936 937 937 938 938 939 - 940 940 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 941 941 942 -* (% style="color:#037691" %) **AT Command**989 +* (% style="color:#037691" %)AT Command: 943 943 944 944 There is no AT Command to control Digital Output 945 945 946 946 947 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x02)** 948 -* **0x02 aa bb cc **~/~/ Set DO1/DO2/DO3 output 994 +* (% style="color:#037691" %)Downlink Payload (prefix 0x02): 949 949 996 +(% class="box infomessage" %) 950 950 ((( 998 +**0x02 aa bb cc ~/~/ Set DO1/DO2/DO3 output** 999 +))) 1000 + 1001 +((( 951 951 If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low. 952 952 ))) 953 953 ... ... @@ -967,19 +967,22 @@ 967 967 968 968 969 969 970 - 971 971 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 972 972 973 -* (% style="color:#037691" %) **AT Command**1023 +* (% style="color:#037691" %)AT Command: 974 974 975 975 There is no AT Command to control Digital Output 976 976 977 977 978 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xA9)**1028 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA9): 979 979 980 -**0xA9 aa bb cc **~/~/ Set DO1/DO2/DO3 output with time control 1030 +(% class="box infomessage" %) 1031 +((( 1032 +((( 1033 +**0xA9 aa bb cc ~/~/ Set DO1/DO2/DO3 output with time control** 1034 +))) 1035 +))) 981 981 982 - 983 983 This is to control the digital output time of DO pin. Include four bytes: 984 984 985 985 (% style="color:#4f81bd" %)**First Byte**(%%)**:** Type code (0xA9) ... ... @@ -1033,19 +1033,20 @@ 1033 1033 1034 1034 1035 1035 1036 - 1037 1037 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1038 1038 1039 -* (% style="color:#037691" %) **AT Command:**1092 +* (% style="color:#037691" %)AT Command: 1040 1040 1041 1041 There is no AT Command to control Relay Output 1042 1042 1043 1043 1044 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x03):**1097 +* (% style="color:#037691" %)Downlink Payload (prefix 0x03): 1045 1045 1046 -**0x03 aa bb **~/~/ Set RO1/RO2 output 1099 +(% class="box infomessage" %) 1100 +((( 1101 +**0x03 aa bb ~/~/ Set RO1/RO2 output** 1102 +))) 1047 1047 1048 - 1049 1049 ((( 1050 1050 If payload = 0x030100, it means set RO1 to close and RO2 to open. 1051 1051 ))) ... ... @@ -1062,19 +1062,20 @@ 1062 1062 1063 1063 1064 1064 1065 - 1066 1066 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1067 1067 1068 -* (% style="color:#037691" %) **AT Command:**1122 +* (% style="color:#037691" %)AT Command: 1069 1069 1070 1070 There is no AT Command to control Relay Output 1071 1071 1072 1072 1073 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x05):**1127 +* (% style="color:#037691" %)Downlink Payload (prefix 0x05): 1074 1074 1075 -**0x05 aa bb cc dd **~/~/ Set RO1/RO2 relay with time control 1129 +(% class="box infomessage" %) 1130 +((( 1131 +**0x05 aa bb cc dd ~/~/ Set RO1/RO2 relay with time control:** 1132 +))) 1076 1076 1077 - 1078 1078 This is to control the relay output time of relay. Include four bytes: 1079 1079 1080 1080 (% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05) ... ... @@ -1116,28 +1116,35 @@ 1116 1116 1117 1117 1118 1118 1119 - 1120 1120 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1121 1121 1122 1122 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1123 1123 1124 -* (% style="color:#037691" %) **AT Command:**1179 +* (% style="color:#037691" %)AT Command: 1125 1125 1126 -**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1181 +(% class="box infomessage" %) 1182 +((( 1183 +**AT+VOLMAX ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]** 1184 +))) 1127 1127 1128 1128 1129 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xA5):**1187 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA5): 1130 1130 1131 -**0xA5 aa bb cc **~/~/ Same as AT+VOLMAX=(aa bb),cc 1189 +(% class="box infomessage" %) 1190 +((( 1191 +**0xA5 aa bb cc ~/~/ Same as AT+VOLMAX=(aa bb),cc** 1192 +))) 1132 1132 1133 1133 1134 1134 1135 - 1136 1136 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1137 1137 1138 -* (% style="color:#037691" %) **AT Command:**1198 +* (% style="color:#037691" %)AT Command: 1139 1139 1140 -(% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) ** 1200 +(% class="box infomessage" %) 1201 +((( 1202 +**AT+SETCNT=aa,(bb cc dd ee) ** 1203 +))) 1141 1141 1142 1142 aa: 1: Set count1, 1143 1143 ... ... @@ -1148,29 +1148,35 @@ 1148 1148 Bb cc dd ee: number to be set 1149 1149 1150 1150 1151 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xA8):**1214 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA8): 1152 1152 1153 -**0x A8 aa bb cc dd ee **~/~/ same as AT+SETCNT=aa,(bb cc dd ee) 1216 +(% class="box infomessage" %) 1217 +((( 1218 +**0x A8 aa bb cc dd ee ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)** 1219 +))) 1154 1154 1155 1155 1156 1156 1157 - 1158 1158 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1159 1159 1160 1160 Clear counting for counting mode 1161 1161 1162 -* (% style="color:#037691" %) **AT Command:**1227 +* (% style="color:#037691" %)AT Command: 1163 1163 1164 -(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1229 +(% class="box infomessage" %) 1230 +((( 1231 +**AT+CLRCOUNT ~/~/ clear all counting** 1232 +))) 1165 1165 1234 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA6): 1166 1166 1167 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** 1236 +(% class="box infomessage" %) 1237 +((( 1238 +**0x A6 01 ~/~/ clear all counting,** 1239 +))) 1168 1168 1169 -**0x A6 01 ** ~/~/ clear all counting 1170 1170 1171 1171 1172 - 1173 - 1174 1174 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1175 1175 1176 1176 * (% style="color:#037691" %)**AT Command:** ... ... @@ -1189,7 +1189,6 @@ 1189 1189 ))) 1190 1190 1191 1191 1192 - 1193 1193 == 3.5 Integrate with Mydevice == 1194 1194 1195 1195 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: