Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,7 +1,6 @@ 1 1 (% style="text-align:center" %) 2 2 [[image:image-20220523163353-1.jpeg||height="604" width="500"]] 3 3 4 -**LT-22222-L LoRa IO Controller User Manual ** 5 5 6 6 7 7 **Table of Contents:** ... ... @@ -167,7 +167,6 @@ 167 167 Packet engine up to 256 bytes with CRC. 168 168 169 169 170 - 171 171 172 172 ))) 173 173 ... ... @@ -203,8 +203,6 @@ 203 203 * 1 x Counting Port 204 204 ))) 205 205 206 - 207 - 208 208 = 2. Power ON Device = 209 209 210 210 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -222,11 +222,11 @@ 222 222 == 3.1 How it works? == 223 223 224 224 ((( 225 -The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on **TX LED** will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. **TX LED** will be on for 5 seconds after joined in network. When there is message from server, the **RX LED**will be on for 1 second.221 +The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%) will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. (% style="color:green" %)**TX LED**(%%) will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second. 226 226 ))) 227 227 228 228 ((( 229 -In case user can ’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.225 +In case user can't set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 230 230 ))) 231 231 232 232 ... ... @@ -278,13 +278,15 @@ 278 278 279 279 There are five working modes + one interrupt mode on LT for different type application: 280 280 281 -* **MOD1**: (default setting): 2 x ACI + 2AVI + DI + DO + RO 282 -* **MOD2**: Double DI Counting + DO + RO 283 -* **MOD3**: Single DI Counting + 2 x ACI + DO + RO 284 -* **MOD4**: Single DI Counting + 1 x Voltage Counting + DO + RO 285 -* **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 286 -* **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 277 +* (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO 278 +* (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO 279 +* (% style="color:blue" %)**MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO 280 +* (% style="color:blue" %)**MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO 281 +* (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 282 +* (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5 287 287 284 + 285 + 288 288 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 289 289 290 290 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -323,6 +323,8 @@ 323 323 * [1] RO1 relay channel is close and the RO1 LED is ON. 324 324 * [0] RO2 relay channel is open and RO2 LED is OFF; 325 325 324 + 325 + 326 326 **LT22222-L:** 327 327 328 328 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -338,6 +338,8 @@ 338 338 ** DO1 is high in case there is load between DO1 and V+. 339 339 ** DO1 LED is off in both case 340 340 341 + 342 + 341 341 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 342 342 343 343 ... ... @@ -411,6 +411,8 @@ 411 411 [[image:image-20220523181246-5.png]] 412 412 413 413 ((( 416 + 417 + 414 414 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 415 415 ))) 416 416 ... ... @@ -424,6 +424,7 @@ 424 424 (% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 425 425 ))) 426 426 431 + 427 427 ((( 428 428 **To use counting mode, please run:** 429 429 ))) ... ... @@ -556,8 +556,8 @@ 556 556 557 557 For example, if user has configured below commands: 558 558 559 -* **AT+MOD=1 ** **~-~->** The normal working mode 560 -* **AT+ADDMOD6=1** **~-~->** Enable trigger 564 +* **AT+MOD=1 ** **~-~->** The normal working mode 565 +* **AT+ADDMOD6=1** **~-~->** Enable trigger 561 561 562 562 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 563 563 ... ... @@ -564,8 +564,10 @@ 564 564 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 565 565 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 566 566 572 + 567 567 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 568 568 575 + 569 569 (% style="color:#4f81bd" %)**Trigger base on voltage**: 570 570 571 571 Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH> ... ... @@ -705,6 +705,8 @@ 705 705 706 706 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 707 707 715 + 716 + 708 708 === 3.4.1 Common Commands === 709 709 710 710 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -713,6 +713,7 @@ 713 713 714 714 === 3.4.2 Sensor related commands === 715 715 725 + 716 716 ==== 3.4.2.1 Set Transmit Interval ==== 717 717 718 718 Set device uplink interval. ... ... @@ -719,23 +719,19 @@ 719 719 720 720 * (% style="color:#037691" %)**AT Command:** 721 721 722 -(% class="box infomessage" %) 723 -((( 724 724 **AT+TDC=N ** 725 -))) 726 726 734 + 727 727 **Example: **AT+TDC=30000. Means set interval to 30 seconds 728 728 729 729 730 730 * (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 731 731 732 -(% class="box infomessage" %) 733 -((( 734 734 **0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 735 -))) 736 736 737 737 738 738 744 + 739 739 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 740 740 741 741 Set work mode. ... ... @@ -742,51 +742,42 @@ 742 742 743 743 * (% style="color:#037691" %)**AT Command:** 744 744 745 -(% class="box infomessage" %) 746 -((( 747 747 **AT+MOD=N ** 748 -))) 749 749 753 + 750 750 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 751 751 752 752 753 753 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 754 754 755 -(% class="box infomessage" %) 756 -((( 757 -**0x0A aa ~/~/ Same as AT+MOD=aa** 758 -))) 759 +**0x0A aa ** ~/~/ Same as AT+MOD=aa 759 759 760 760 761 761 763 + 762 762 ==== 3.4.2.3 Poll an uplink ==== 763 763 764 -* (% style="color:#037691" %)AT Command: 766 +* (% style="color:#037691" %)**AT Command:** 765 765 766 766 There is no AT Command to poll uplink 767 767 768 768 769 -* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 771 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x08):** 770 770 771 -(% class="box infomessage" %) 772 -((( 773 -**0x08 FF ~/~/ Poll an uplink,** 774 -))) 773 +**0x08 FF **~/~/ Poll an uplink 775 775 776 776 **Example**: 0x08FF, ask device to send an Uplink 777 777 778 778 779 779 779 + 780 780 ==== 3.4.2.4 Enable Trigger Mode ==== 781 781 782 782 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 783 783 784 -* (% style="color:#037691" %)AT Command: 784 +* (% style="color:#037691" %)**AT Command:** 785 785 786 -(% class="box infomessage" %) 787 -((( 788 788 **AT+ADDMOD6=1 or 0** 789 -))) 790 790 791 791 1: Enable Trigger Mode 792 792 ... ... @@ -793,38 +793,34 @@ 793 793 0: Disable Trigger Mode 794 794 795 795 796 -* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 793 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):** 797 797 798 -(% class="box infomessage" %) 799 -((( 800 -**0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 801 -))) 795 +**0x0A 06 aa ** ~/~/ Same as AT+ADDMOD6=aa 802 802 803 803 804 804 799 + 805 805 ==== 3.4.2.5 Poll trigger settings ==== 806 806 807 807 Poll trigger settings, 808 808 809 -* (% style="color:#037691" %)AT Command: 804 +* (% style="color:#037691" %)**AT Command:** 810 810 811 811 There is no AT Command for this feature. 812 812 813 813 814 -* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 809 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):** 815 815 816 -(% class="box infomessage" %) 817 -((( 818 -**0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 819 -))) 811 +**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 820 820 821 821 822 822 815 + 823 823 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 824 824 825 825 Enable Disable DI1/DI2/DI2 as trigger, 826 826 827 -* (% style="color:#037691" %)AT Command: 820 +* (% style="color:#037691" %)**AT Command:** 828 828 829 829 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 830 830 ... ... @@ -833,7 +833,7 @@ 833 833 834 834 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 835 835 836 -* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 829 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):** 837 837 838 838 **0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 839 839 ... ... @@ -844,7 +844,7 @@ 844 844 845 845 Set DI1 or DI3(for LT-33222-L) trigger. 846 846 847 -* (% style="color:#037691" %)AT Command: 840 +* (% style="color:#037691" %)**AT Command:** 848 848 849 849 **AT+TRIG1=a,b** 850 850 ... ... @@ -861,7 +861,6 @@ 861 861 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 862 862 * **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 863 863 864 - 865 865 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 866 866 867 867 Set DI2 trigger. ... ... @@ -922,11 +922,11 @@ 922 922 923 923 ==== 3.4.2.11 Trigger – Set minimum interval ==== 924 924 925 -Set AV and AC trigger minimum interval, system won ’t response to the second trigger within this set time after the first trigger.917 +Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger. 926 926 927 927 * (% style="color:#037691" %)**AT Command** 928 928 929 -**AT+ATDC=5 .Device won’t response the second trigger within 5 minute after the first trigger.**921 +**AT+ATDC=5 ** Device won't response the second trigger within 5 minute after the first trigger. 930 930 931 931 932 932 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** ... ... @@ -933,9 +933,15 @@ 933 933 934 934 **0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 935 935 928 +((( 929 + 936 936 931 +(% style="color:red" %)Note: ATDC setting must be more than 5min 932 +))) 937 937 938 938 935 + 936 + 939 939 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 940 940 941 941 * (% style="color:#037691" %)**AT Command** ... ... @@ -1136,7 +1136,7 @@ 1136 1136 1137 1137 * (% style="color:#037691" %)**AT Command:** 1138 1138 1139 - (% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) **1137 +**AT+SETCNT=aa,(bb cc dd ee) ** 1140 1140 1141 1141 aa: 1: Set count1, 1142 1142 ... ... @@ -1160,7 +1160,7 @@ 1160 1160 1161 1161 * (% style="color:#037691" %)**AT Command:** 1162 1162 1163 - (% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting1161 +**AT+CLRCOUNT ** ~/~/ clear all counting 1164 1164 1165 1165 1166 1166 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** ... ... @@ -1418,6 +1418,7 @@ 1418 1418 [[image:image-20220524100748-11.png]] 1419 1419 1420 1420 1419 + 1421 1421 = 4. Use AT Command = 1422 1422 1423 1423 == 4.1 Access AT Command == ... ... @@ -1620,8 +1620,6 @@ 1620 1620 1621 1621 ((( 1622 1622 AT+CFG: Print all settings 1623 - 1624 - 1625 1625 ))) 1626 1626 1627 1627 ... ... @@ -1667,8 +1667,6 @@ 1667 1667 1668 1668 ((( 1669 1669 (% style="background-color:#dcdcdc" %)ATZ 1670 - 1671 - 1672 1672 ))) 1673 1673 1674 1674 ... ... @@ -1875,6 +1875,8 @@ 1875 1875 == 5.5 Can i use point to point communication for LT-22222-L? == 1876 1876 1877 1877 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1873 + 1874 + 1878 1878 ))) 1879 1879 1880 1880 ((( ... ... @@ -1888,6 +1888,7 @@ 1888 1888 1889 1889 After restart, the status before power failure will be read from flash. 1890 1890 1888 + 1891 1891 = 6. Trouble Shooting = 1892 1892 ))) 1893 1893 ... ... @@ -1922,10 +1922,8 @@ 1922 1922 ))) 1923 1923 1924 1924 1925 - 1926 1926 = 7. Order Info = 1927 1927 1928 - 1929 1929 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1930 1930 1931 1931 ... ... @@ -1965,6 +1965,10 @@ 1965 1965 ))) 1966 1966 * ((( 1967 1967 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1964 + 1965 + 1966 + 1967 + 1968 1968 ))) 1969 1969 1970 1970 = 10. Reference =