... ... @@ -181,6 +181,10 @@
181 181  * Firmware upgradable via program port
182 182  * Counting
183 183  
184 +
185 +
186 +
187 +
184 184  == 1.4  Applications ==
185 185  
186 186  * Smart Buildings & Home Automation
... ... @@ -190,6 +190,10 @@
190 190  * Smart Cities
191 191  * Smart Factory
192 192  
197 +
198 +
199 +
200 +
193 193  == 1.5 Hardware Variants ==
194 194  
195 195  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -204,7 +204,6 @@
204 204  )))
205 205  
206 206  
207 -
208 208  = 2. Power ON Device =
209 209  
210 210  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -719,23 +719,19 @@
719 719  
720 720  * (% style="color:#037691" %)**AT Command:**
721 721  
722 -(% class="box infomessage" %)
723 -(((
724 724  **AT+TDC=N **
725 -)))
726 726  
731 +
727 727  **Example: **AT+TDC=30000. Means set interval to 30 seconds
728 728  
729 729  
730 730  * (% style="color:#037691" %)**Downlink Payload (prefix 0x01):**
731 731  
732 -(% class="box infomessage" %)
733 -(((
734 734  **0x01 aa bb cc     ~/~/ Same as AT+TDC=0x(aa bb cc)**
735 -)))
736 736  
737 737  
738 738  
741 +
739 739  ==== 3.4.2.2 Set Work Mode (AT+MOD) ====
740 740  
741 741  Set work mode.
... ... @@ -742,36 +742,29 @@
742 742  
743 743  * (% style="color:#037691" %)**AT Command:**
744 744  
745 -(% class="box infomessage" %)
746 -(((
747 747  **AT+MOD=N  **
748 -)))
749 749  
750 +
750 750  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
751 751  
752 752  
753 753  * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):**
754 754  
755 -(% class="box infomessage" %)
756 -(((
757 -**0x0A aa     ~/~/ Same as AT+MOD=aa**
758 -)))
756 +**0x0A aa    ** ~/~/ Same as AT+MOD=aa
759 759  
760 760  
761 761  
760 +
762 762  ==== 3.4.2.3 Poll an uplink ====
763 763  
764 -* (% style="color:#037691" %)AT Command:
763 +* (% style="color:#037691" %)**AT Command:**
765 765  
766 766  There is no AT Command to poll uplink
767 767  
768 768  
769 -* (% style="color:#037691" %)Downlink Payload (prefix 0x08):
768 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x08):**
770 770  
771 -(% class="box infomessage" %)
772 -(((
773 -**0x08 FF     ~/~/ Poll an uplink,**
774 -)))
770 +**0x08 FF     **~/~/ Poll an uplink
775 775  
776 776  **Example**: 0x08FF, ask device to send an Uplink
777 777  
... ... @@ -781,12 +781,9 @@
781 781  
782 782  Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
783 783  
784 -* (% style="color:#037691" %)AT Command:
780 +* (% style="color:#037691" %)**AT Command:**
785 785  
786 -(% class="box infomessage" %)
787 -(((
788 788  **AT+ADDMOD6=1 or 0**
789 -)))
790 790  
791 791  1: Enable Trigger Mode
792 792  
... ... @@ -793,38 +793,34 @@
793 793  0: Disable Trigger Mode
794 794  
795 795  
796 -* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06):
789 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):**
797 797  
798 -(% class="box infomessage" %)
799 -(((
800 -**0x0A 06 aa     ~/~/ Same as AT+ADDMOD6=aa,**
801 -)))
791 +**0x0A 06 aa    ** ~/~/ Same as AT+ADDMOD6=aa
802 802  
803 803  
804 804  
795 +
805 805  ==== 3.4.2.5 Poll trigger settings ====
806 806  
807 807  Poll trigger settings,
808 808  
809 -* (% style="color:#037691" %)AT Command:
800 +* (% style="color:#037691" %)**AT Command:**
810 810  
811 811  There is no AT Command for this feature.
812 812  
813 813  
814 -* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06):
805 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):**
815 815  
816 -(% class="box infomessage" %)
817 -(((
818 -**0xAB 06  ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command**
819 -)))
807 +**0xAB 06         **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command
820 820  
821 821  
822 822  
811 +
823 823  ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ====
824 824  
825 825  Enable Disable DI1/DI2/DI2 as trigger,
826 826  
827 -* (% style="color:#037691" %)AT Command:
816 +* (% style="color:#037691" %)**AT Command:**
828 828  
829 829  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
830 830  
... ... @@ -833,7 +833,7 @@
833 833  
834 834  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
835 835  
836 -* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02):
825 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):**
837 837  
838 838  **0xAA 02 aa bb        **~/~/ Same as AT+DTRI=aa,bb
839 839  
... ... @@ -844,7 +844,7 @@
844 844  
845 845  Set DI1 or DI3(for LT-33222-L) trigger.
846 846  
847 -* (% style="color:#037691" %)AT Command:
836 +* (% style="color:#037691" %)**AT Command:**
848 848  
849 849  **AT+TRIG1=a,b**
850 850  
... ... @@ -862,6 +862,7 @@
862 862  * **0x09 01 aa bb cc    ** ~/~/ same as AT+TRIG1=aa,0x(bb cc)
863 863  
864 864  
854 +
865 865  ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
866 866  
867 867  Set DI2 trigger.
... ... @@ -922,11 +922,11 @@
922 922  
923 923  ==== 3.4.2.11 Trigger – Set minimum interval ====
924 924  
925 -Set AV and AC trigger minimum interval, system wont response to the second trigger within this set time after the first trigger.
915 +Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger.
926 926  
927 927  * (% style="color:#037691" %)**AT Command**
928 928  
929 -**AT+ATDC=5. Device wont response the second trigger within 5 minute after the first trigger.**
919 +**AT+ATDC=5        ** Device won't response the second trigger within 5 minute after the first trigger.
930 930  
931 931  
932 932  * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )**
... ... @@ -1136,7 +1136,7 @@
1136 1136  
1137 1137  * (% style="color:#037691" %)**AT Command:**
1138 1138  
1139 -(% style="color:#037691" %)**​​​​​​​**(%%)**AT+SETCNT=aa,(bb cc dd ee) **
1129 +**AT+SETCNT=aa,(bb cc dd ee) **
1140 1140  
1141 1141  aa: 1: Set count1,
1142 1142  
... ... @@ -1160,7 +1160,7 @@
1160 1160  
1161 1161  * (% style="color:#037691" %)**AT Command:**
1162 1162  
1163 -(% style="color:#037691" %)​​​​​​​​​​​​​​(%%)**AT+CLRCOUNT ** ~/~/ clear all counting
1153 +**AT+CLRCOUNT ** ~/~/ clear all counting
1164 1164  
1165 1165  
1166 1166  * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):**
... ... @@ -1418,6 +1418,7 @@
1418 1418  [[image:image-20220524100748-11.png]]
1419 1419  
1420 1420  
1411 +
1421 1421  = 4. Use AT Command =
1422 1422  
1423 1423  == 4.1 Access AT Command ==
... ... @@ -1620,8 +1620,6 @@
1620 1620  
1621 1621  (((
1622 1622  AT+CFG: Print all settings
1623 -
1624 -
1625 1625  )))
1626 1626  
1627 1627  
... ... @@ -1667,8 +1667,6 @@
1667 1667  
1668 1668  (((
1669 1669  (% style="background-color:#dcdcdc" %)ATZ
1670 -
1671 -
1672 1672  )))
1673 1673  
1674 1674  
... ... @@ -1875,6 +1875,8 @@
1875 1875  == 5.5 Can i use point to point communication for LT-22222-L? ==
1876 1876  
1877 1877  Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]]
1865 +
1866 +
1878 1878  )))
1879 1879  
1880 1880  (((
... ... @@ -1888,6 +1888,7 @@
1888 1888  
1889 1889  After restart, the status before power failure will be read from flash.
1890 1890  
1880 +
1891 1891  = 6. Trouble Shooting =
1892 1892  )))
1893 1893  
... ... @@ -1941,6 +1941,8 @@
1941 1941  * (% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865
1942 1942  * (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779
1943 1943  
1934 +
1935 +
1944 1944  = 8. Packing Info =
1945 1945  
1946 1946  
... ... @@ -1958,6 +1958,8 @@
1958 1958  * Package Size / pcs : 14.5 x 8 x 5 cm
1959 1959  * Weight / pcs : 170g
1960 1960  
1953 +
1954 +
1961 1961  = 9. Support =
1962 1962  
1963 1963  * (((
... ... @@ -1965,6 +1965,10 @@
1965 1965  )))
1966 1966  * (((
1967 1967  Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
1962 +
1963 +
1964 +
1965 +
1968 1968  )))
1969 1969  
1970 1970  = 10. Reference​​​​​ =