Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -564,6 +564,7 @@ 564 564 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 565 565 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 566 566 567 + 567 567 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 568 568 569 569 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -719,23 +719,19 @@ 719 719 720 720 * (% style="color:#037691" %)**AT Command:** 721 721 722 -(% class="box infomessage" %) 723 -((( 724 724 **AT+TDC=N ** 725 -))) 726 726 725 + 727 727 **Example: **AT+TDC=30000. Means set interval to 30 seconds 728 728 729 729 730 730 * (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 731 731 732 -(% class="box infomessage" %) 733 -((( 734 734 **0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 735 -))) 736 736 737 737 738 738 735 + 739 739 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 740 740 741 741 Set work mode. ... ... @@ -742,36 +742,29 @@ 742 742 743 743 * (% style="color:#037691" %)**AT Command:** 744 744 745 -(% class="box infomessage" %) 746 -((( 747 747 **AT+MOD=N ** 748 -))) 749 749 744 + 750 750 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 751 751 752 752 753 753 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 754 754 755 -(% class="box infomessage" %) 756 -((( 757 -**0x0A aa ~/~/ Same as AT+MOD=aa** 758 -))) 750 +**0x0A aa ** ~/~/ Same as AT+MOD=aa 759 759 760 760 761 761 754 + 762 762 ==== 3.4.2.3 Poll an uplink ==== 763 763 764 -* (% style="color:#037691" %)AT Command: 757 +* (% style="color:#037691" %)**AT Command:** 765 765 766 766 There is no AT Command to poll uplink 767 767 768 768 769 -* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 762 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x08):** 770 770 771 -(% class="box infomessage" %) 772 -((( 773 -**0x08 FF ~/~/ Poll an uplink,** 774 -))) 764 +**0x08 FF **~/~/ Poll an uplink 775 775 776 776 **Example**: 0x08FF, ask device to send an Uplink 777 777 ... ... @@ -781,12 +781,9 @@ 781 781 782 782 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 783 783 784 -* (% style="color:#037691" %)AT Command: 774 +* (% style="color:#037691" %)**AT Command:** 785 785 786 -(% class="box infomessage" %) 787 -((( 788 788 **AT+ADDMOD6=1 or 0** 789 -))) 790 790 791 791 1: Enable Trigger Mode 792 792 ... ... @@ -793,38 +793,34 @@ 793 793 0: Disable Trigger Mode 794 794 795 795 796 -* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 783 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):** 797 797 798 -(% class="box infomessage" %) 799 -((( 800 -**0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 801 -))) 785 +**0x0A 06 aa ** ~/~/ Same as AT+ADDMOD6=aa 802 802 803 803 804 804 789 + 805 805 ==== 3.4.2.5 Poll trigger settings ==== 806 806 807 807 Poll trigger settings, 808 808 809 -* (% style="color:#037691" %)AT Command: 794 +* (% style="color:#037691" %)**AT Command:** 810 810 811 811 There is no AT Command for this feature. 812 812 813 813 814 -* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 799 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):** 815 815 816 -(% class="box infomessage" %) 817 -((( 818 -**0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 819 -))) 801 +**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 820 820 821 821 822 822 805 + 823 823 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 824 824 825 825 Enable Disable DI1/DI2/DI2 as trigger, 826 826 827 -* (% style="color:#037691" %)AT Command: 810 +* (% style="color:#037691" %)**AT Command:** 828 828 829 829 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 830 830 ... ... @@ -833,7 +833,7 @@ 833 833 834 834 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 835 835 836 -* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 819 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):** 837 837 838 838 **0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 839 839 ... ... @@ -844,7 +844,7 @@ 844 844 845 845 Set DI1 or DI3(for LT-33222-L) trigger. 846 846 847 -* (% style="color:#037691" %)AT Command: 830 +* (% style="color:#037691" %)**AT Command:** 848 848 849 849 **AT+TRIG1=a,b** 850 850 ... ... @@ -862,6 +862,8 @@ 862 862 * **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 863 863 864 864 848 + 849 + 865 865 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 866 866 867 867 Set DI2 trigger. ... ... @@ -922,11 +922,11 @@ 922 922 923 923 ==== 3.4.2.11 Trigger – Set minimum interval ==== 924 924 925 -Set AV and AC trigger minimum interval, system won ’t response to the second trigger within this set time after the first trigger.910 +Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger. 926 926 927 927 * (% style="color:#037691" %)**AT Command** 928 928 929 -**AT+ATDC=5 .Device won’t response the second trigger within 5 minute after the first trigger.**914 +**AT+ATDC=5 ** Device won't response the second trigger within 5 minute after the first trigger. 930 930 931 931 932 932 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** ... ... @@ -1136,7 +1136,7 @@ 1136 1136 1137 1137 * (% style="color:#037691" %)**AT Command:** 1138 1138 1139 - (% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) **1124 +**AT+SETCNT=aa,(bb cc dd ee) ** 1140 1140 1141 1141 aa: 1: Set count1, 1142 1142 ... ... @@ -1160,7 +1160,7 @@ 1160 1160 1161 1161 * (% style="color:#037691" %)**AT Command:** 1162 1162 1163 -(% style="color:#037691" %) (%%)**AT+CLRCOUNT ** ~/~/ clear all counting1148 +(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1164 1164 1165 1165 1166 1166 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** ... ... @@ -1418,6 +1418,7 @@ 1418 1418 [[image:image-20220524100748-11.png]] 1419 1419 1420 1420 1406 + 1421 1421 = 4. Use AT Command = 1422 1422 1423 1423 == 4.1 Access AT Command == ... ... @@ -1620,8 +1620,6 @@ 1620 1620 1621 1621 ((( 1622 1622 AT+CFG: Print all settings 1623 - 1624 - 1625 1625 ))) 1626 1626 1627 1627 ... ... @@ -1667,8 +1667,6 @@ 1667 1667 1668 1668 ((( 1669 1669 (% style="background-color:#dcdcdc" %)ATZ 1670 - 1671 - 1672 1672 ))) 1673 1673 1674 1674 ... ... @@ -1875,6 +1875,8 @@ 1875 1875 == 5.5 Can i use point to point communication for LT-22222-L? == 1876 1876 1877 1877 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1860 + 1861 + 1878 1878 ))) 1879 1879 1880 1880 ((( ... ... @@ -1888,6 +1888,7 @@ 1888 1888 1889 1889 After restart, the status before power failure will be read from flash. 1890 1890 1875 + 1891 1891 = 6. Trouble Shooting = 1892 1892 ))) 1893 1893 ... ... @@ -1941,6 +1941,9 @@ 1941 1941 * (% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865 1942 1942 * (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779 1943 1943 1929 + 1930 + 1931 + 1944 1944 = 8. Packing Info = 1945 1945 1946 1946 ... ... @@ -1958,6 +1958,9 @@ 1958 1958 * Package Size / pcs : 14.5 x 8 x 5 cm 1959 1959 * Weight / pcs : 170g 1960 1960 1949 + 1950 + 1951 + 1961 1961 = 9. Support = 1962 1962 1963 1963 * ((( ... ... @@ -1965,6 +1965,10 @@ 1965 1965 ))) 1966 1966 * ((( 1967 1967 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1959 + 1960 + 1961 + 1962 + 1968 1968 ))) 1969 1969 1970 1970 = 10. Reference =