<
From version < 82.27 >
edited by Xiaoling
on 2022/06/20 12:01
To version < 82.25 >
edited by Xiaoling
on 2022/06/20 12:00
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -181,6 +181,7 @@
181 181  * Firmware upgradable via program port
182 182  * Counting
183 183  
184 +
184 184  == 1.4  Applications ==
185 185  
186 186  * Smart Buildings & Home Automation
... ... @@ -190,6 +190,7 @@
190 190  * Smart Cities
191 191  * Smart Factory
192 192  
194 +
193 193  == 1.5 Hardware Variants ==
194 194  
195 195  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -205,6 +205,7 @@
205 205  
206 206  
207 207  
210 +
208 208  = 2. Power ON Device =
209 209  
210 210  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -285,6 +285,7 @@
285 285  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
286 286  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
287 287  
291 +
288 288  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
289 289  
290 290  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -338,6 +338,7 @@
338 338  ** DO1 is high in case there is load between DO1 and V+.
339 339  ** DO1 LED is off in both case
340 340  
345 +
341 341  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
342 342  
343 343  
... ... @@ -387,20 +387,24 @@
387 387  
388 388  (((
389 389  **For LT22222-L:**
395 +)))
390 390  
397 +(% class="box infomessage" %)
398 +(((
399 +(((
400 +**AT+TRIG1=0,100  (set DI1 port to trigger on low level, valid signal is 100ms) **
391 391  
392 -(% style="color:blue" %)**AT+TRIG1=0,100**(%%)**  (set DI1 port to trigger on low level, valid signal is 100ms) **
402 +**AT+TRIG1=1,100  (set DI1 port to trigger on high level, valid signal is 100ms ) **
393 393  
394 -(% style="color:blue" %)**AT+TRIG1=1,100**(%%)**  (set DI1 port to trigger on high level, valid signal is 100ms ) **
404 +**AT+TRIG2=0,100  (set DI2 port to trigger on low level, valid signal is 100ms) **
395 395  
396 -(% style="color:blue" %)**AT+TRIG2=0,100**(%%)**  (set DI2 port to trigger on low level, valid signal is 100ms) **
406 +**AT+TRIG2=1,100  (set DI2 port to trigger on high level, valid signal is 100ms ) **
397 397  
398 -(% style="color:blue" %)**AT+TRIG2=1,100**(%%)**  (set DI2 port to trigger on high level, valid signal is 100ms ) **
408 +**AT+SETCNT=1,6  (Set COUNT1 value to 60)**
399 399  
400 -(% style="color:blue" %)**AT+SETCNT=1,60**(%%)**   (Set COUNT1 value to 60)**
401 -
402 -(% style="color:blue" %)**AT+SETCNT=2,60**(%%)**   (Set COUNT2 value to 60)**
410 +**AT+SETCNT=2,60   (Set COUNT2 value to 60)**
403 403  )))
412 +)))
404 404  
405 405  
406 406  
... ... @@ -564,6 +564,7 @@
564 564  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
565 565  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
566 566  
576 +
567 567  (% style="color:#037691" %)**AT Command to set Trigger Condition**:
568 568  
569 569  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -705,6 +705,7 @@
705 705  
706 706  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
707 707  
718 +
708 708  === 3.4.1 Common Commands ===
709 709  
710 710  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -862,6 +862,7 @@
862 862  * **0x09 01 aa bb cc    ** ~/~/ same as AT+TRIG1=aa,0x(bb cc)
863 863  
864 864  
876 +
865 865  ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
866 866  
867 867  Set DI2 trigger.
... ... @@ -1136,7 +1136,7 @@
1136 1136  
1137 1137  * (% style="color:#037691" %)**AT Command:**
1138 1138  
1139 -(% style="color:#037691" %)**​​​​​​​**(%%)**AT+SETCNT=aa,(bb cc dd ee) **
1151 +(% style="color:#037691" %)**​​​​​​​​​​​​​​**(%%)**AT+SETCNT=aa,(bb cc dd ee) **
1140 1140  
1141 1141  aa: 1: Set count1,
1142 1142  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0