Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
From version 82.26
edited by Xiaoling
on 2022/06/20 12:00
on 2022/06/20 12:00
Change comment:
There is no comment for this version
To version 83.1
edited by Bei Jinggeng
on 2022/06/28 13:36
on 2022/06/28 13:36
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -205,9 +205,6 @@ 205 205 * 1 x Counting Port 206 206 ))) 207 207 208 - 209 - 210 - 211 211 = 2. Power ON Device = 212 212 213 213 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -289,6 +289,7 @@ 289 289 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 290 290 291 291 289 + 292 292 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 293 293 294 294 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -343,6 +343,7 @@ 343 343 ** DO1 LED is off in both case 344 344 345 345 344 + 346 346 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 347 347 348 348 ... ... @@ -394,17 +394,17 @@ 394 394 **For LT22222-L:** 395 395 396 396 397 -**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 396 +(% style="color:blue" %)**AT+TRIG1=0,100**(%%)** (set DI1 port to trigger on low level, valid signal is 100ms) ** 398 398 399 -**AT+TRIG1=1,100 (set DI1 port to trigger on high level, valid signal is 100ms ) ** 398 +(% style="color:blue" %)**AT+TRIG1=1,100**(%%)** (set DI1 port to trigger on high level, valid signal is 100ms ) ** 400 400 401 -**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 400 +(% style="color:blue" %)**AT+TRIG2=0,100**(%%)** (set DI2 port to trigger on low level, valid signal is 100ms) ** 402 402 403 -**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 402 +(% style="color:blue" %)**AT+TRIG2=1,100**(%%)** (set DI2 port to trigger on high level, valid signal is 100ms ) ** 404 404 405 -**AT+SETCNT=1,60 (Set COUNT1 value to 60)** 404 +(% style="color:blue" %)**AT+SETCNT=1,60**(%%)** (Set COUNT1 value to 60)** 406 406 407 -**AT+SETCNT=2,60 (Set COUNT2 value to 60)** 406 +(% style="color:blue" %)**AT+SETCNT=2,60**(%%)** (Set COUNT2 value to 60)** 408 408 ))) 409 409 410 410 ... ... @@ -569,7 +569,6 @@ 569 569 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 570 570 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 571 571 572 - 573 573 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 574 574 575 575 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -712,6 +712,7 @@ 712 712 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 713 713 714 714 713 + 715 715 === 3.4.1 Common Commands === 716 716 717 717 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -726,23 +726,19 @@ 726 726 727 727 * (% style="color:#037691" %)**AT Command:** 728 728 729 -(% class="box infomessage" %) 730 -((( 731 731 **AT+TDC=N ** 732 -))) 733 733 730 + 734 734 **Example: **AT+TDC=30000. Means set interval to 30 seconds 735 735 736 736 737 737 * (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 738 738 739 -(% class="box infomessage" %) 740 -((( 741 741 **0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 742 -))) 743 743 744 744 745 745 740 + 746 746 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 747 747 748 748 Set work mode. ... ... @@ -749,36 +749,29 @@ 749 749 750 750 * (% style="color:#037691" %)**AT Command:** 751 751 752 -(% class="box infomessage" %) 753 -((( 754 754 **AT+MOD=N ** 755 -))) 756 756 749 + 757 757 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 758 758 759 759 760 760 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 761 761 762 -(% class="box infomessage" %) 763 -((( 764 -**0x0A aa ~/~/ Same as AT+MOD=aa** 765 -))) 755 +**0x0A aa ** ~/~/ Same as AT+MOD=aa 766 766 767 767 768 768 759 + 769 769 ==== 3.4.2.3 Poll an uplink ==== 770 770 771 -* (% style="color:#037691" %)AT Command: 762 +* (% style="color:#037691" %)**AT Command:** 772 772 773 773 There is no AT Command to poll uplink 774 774 775 775 776 -* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 767 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x08):** 777 777 778 -(% class="box infomessage" %) 779 -((( 780 -**0x08 FF ~/~/ Poll an uplink,** 781 -))) 769 +**0x08 FF **~/~/ Poll an uplink 782 782 783 783 **Example**: 0x08FF, ask device to send an Uplink 784 784 ... ... @@ -788,12 +788,9 @@ 788 788 789 789 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 790 790 791 -* (% style="color:#037691" %)AT Command: 779 +* (% style="color:#037691" %)**AT Command:** 792 792 793 -(% class="box infomessage" %) 794 -((( 795 795 **AT+ADDMOD6=1 or 0** 796 -))) 797 797 798 798 1: Enable Trigger Mode 799 799 ... ... @@ -800,38 +800,34 @@ 800 800 0: Disable Trigger Mode 801 801 802 802 803 -* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 788 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):** 804 804 805 -(% class="box infomessage" %) 806 -((( 807 -**0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 808 -))) 790 +**0x0A 06 aa ** ~/~/ Same as AT+ADDMOD6=aa 809 809 810 810 811 811 794 + 812 812 ==== 3.4.2.5 Poll trigger settings ==== 813 813 814 814 Poll trigger settings, 815 815 816 -* (% style="color:#037691" %)AT Command: 799 +* (% style="color:#037691" %)**AT Command:** 817 817 818 818 There is no AT Command for this feature. 819 819 820 820 821 -* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 804 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):** 822 822 823 -(% class="box infomessage" %) 824 -((( 825 -**0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 826 -))) 806 +**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 827 827 828 828 829 829 810 + 830 830 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 831 831 832 832 Enable Disable DI1/DI2/DI2 as trigger, 833 833 834 -* (% style="color:#037691" %)AT Command: 815 +* (% style="color:#037691" %)**AT Command:** 835 835 836 836 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 837 837 ... ... @@ -840,7 +840,7 @@ 840 840 841 841 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 842 842 843 -* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 824 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):** 844 844 845 845 **0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 846 846 ... ... @@ -851,7 +851,7 @@ 851 851 852 852 Set DI1 or DI3(for LT-33222-L) trigger. 853 853 854 -* (% style="color:#037691" %)AT Command: 835 +* (% style="color:#037691" %)**AT Command:** 855 855 856 856 **AT+TRIG1=a,b** 857 857 ... ... @@ -868,8 +868,6 @@ 868 868 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 869 869 * **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 870 870 871 - 872 - 873 873 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 874 874 875 875 Set DI2 trigger. ... ... @@ -930,11 +930,11 @@ 930 930 931 931 ==== 3.4.2.11 Trigger – Set minimum interval ==== 932 932 933 -Set AV and AC trigger minimum interval, system won ’t response to the second trigger within this set time after the first trigger.912 +Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger. 934 934 935 935 * (% style="color:#037691" %)**AT Command** 936 936 937 -**AT+ATDC=5 .Device won’t response the second trigger within 5 minute after the first trigger.**916 +**AT+ATDC=5 ** Device won't response the second trigger within 5 minute after the first trigger. 938 938 939 939 940 940 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** ... ... @@ -941,9 +941,14 @@ 941 941 942 942 **0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 943 943 923 +((( 924 + 944 944 926 +(% style="color:red" %)Note: ATDC setting must be more than 5min 927 +))) 945 945 946 946 930 + 947 947 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 948 948 949 949 * (% style="color:#037691" %)**AT Command** ... ... @@ -1144,7 +1144,7 @@ 1144 1144 1145 1145 * (% style="color:#037691" %)**AT Command:** 1146 1146 1147 - (% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) **1131 +**AT+SETCNT=aa,(bb cc dd ee) ** 1148 1148 1149 1149 aa: 1: Set count1, 1150 1150 ... ... @@ -1168,7 +1168,7 @@ 1168 1168 1169 1169 * (% style="color:#037691" %)**AT Command:** 1170 1170 1171 - (% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting1155 +**AT+CLRCOUNT ** ~/~/ clear all counting 1172 1172 1173 1173 1174 1174 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** ... ... @@ -1426,6 +1426,7 @@ 1426 1426 [[image:image-20220524100748-11.png]] 1427 1427 1428 1428 1413 + 1429 1429 = 4. Use AT Command = 1430 1430 1431 1431 == 4.1 Access AT Command == ... ... @@ -1628,8 +1628,6 @@ 1628 1628 1629 1629 ((( 1630 1630 AT+CFG: Print all settings 1631 - 1632 - 1633 1633 ))) 1634 1634 1635 1635 ... ... @@ -1675,8 +1675,6 @@ 1675 1675 1676 1676 ((( 1677 1677 (% style="background-color:#dcdcdc" %)ATZ 1678 - 1679 - 1680 1680 ))) 1681 1681 1682 1682 ... ... @@ -1883,6 +1883,8 @@ 1883 1883 == 5.5 Can i use point to point communication for LT-22222-L? == 1884 1884 1885 1885 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1867 + 1868 + 1886 1886 ))) 1887 1887 1888 1888 ((( ... ... @@ -1896,6 +1896,7 @@ 1896 1896 1897 1897 After restart, the status before power failure will be read from flash. 1898 1898 1882 + 1899 1899 = 6. Trouble Shooting = 1900 1900 ))) 1901 1901 ... ... @@ -1930,10 +1930,8 @@ 1930 1930 ))) 1931 1931 1932 1932 1933 - 1934 1934 = 7. Order Info = 1935 1935 1936 - 1937 1937 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1938 1938 1939 1939 ... ... @@ -1973,6 +1973,10 @@ 1973 1973 ))) 1974 1974 * ((( 1975 1975 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1958 + 1959 + 1960 + 1961 + 1976 1976 ))) 1977 1977 1978 1978 = 10. Reference =