Last modified by Mengting Qiu on 2025/06/04 18:42

From version 82.26
edited by Xiaoling
on 2022/06/20 12:00
Change comment: There is no comment for this version
To version 82.32
edited by Xiaoling
on 2022/06/20 13:36
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -181,7 +181,6 @@
181 181  * Firmware upgradable via program port
182 182  * Counting
183 183  
184 -
185 185  == 1.4  Applications ==
186 186  
187 187  * Smart Buildings & Home Automation
... ... @@ -191,7 +191,6 @@
191 191  * Smart Cities
192 192  * Smart Factory
193 193  
194 -
195 195  == 1.5 Hardware Variants ==
196 196  
197 197  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -207,7 +207,6 @@
207 207  
208 208  
209 209  
210 -
211 211  = 2. Power ON Device =
212 212  
213 213  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -288,7 +288,6 @@
288 288  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
289 289  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
290 290  
291 -
292 292  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
293 293  
294 294  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -342,7 +342,6 @@
342 342  ** DO1 is high in case there is load between DO1 and V+.
343 343  ** DO1 LED is off in both case
344 344  
345 -
346 346  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
347 347  
348 348  
... ... @@ -394,17 +394,17 @@
394 394  **For LT22222-L:**
395 395  
396 396  
397 -**AT+TRIG1=0,100  (set DI1 port to trigger on low level, valid signal is 100ms) **
392 +(% style="color:blue" %)**AT+TRIG1=0,100**(%%)**  (set DI1 port to trigger on low level, valid signal is 100ms) **
398 398  
399 -**AT+TRIG1=1,100  (set DI1 port to trigger on high level, valid signal is 100ms ) **
394 +(% style="color:blue" %)**AT+TRIG1=1,100**(%%)**  (set DI1 port to trigger on high level, valid signal is 100ms ) **
400 400  
401 -**AT+TRIG2=0,100  (set DI2 port to trigger on low level, valid signal is 100ms) **
396 +(% style="color:blue" %)**AT+TRIG2=0,100**(%%)**  (set DI2 port to trigger on low level, valid signal is 100ms) **
402 402  
403 -**AT+TRIG2=1,100  (set DI2 port to trigger on high level, valid signal is 100ms ) **
398 +(% style="color:blue" %)**AT+TRIG2=1,100**(%%)**  (set DI2 port to trigger on high level, valid signal is 100ms ) **
404 404  
405 -**AT+SETCNT=1,60   (Set COUNT1 value to 60)**
400 +(% style="color:blue" %)**AT+SETCNT=1,60**(%%)**   (Set COUNT1 value to 60)**
406 406  
407 -**AT+SETCNT=2,60   (Set COUNT2 value to 60)**
402 +(% style="color:blue" %)**AT+SETCNT=2,60**(%%)**   (Set COUNT2 value to 60)**
408 408  )))
409 409  
410 410  
... ... @@ -711,7 +711,6 @@
711 711  
712 712  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
713 713  
714 -
715 715  === 3.4.1 Common Commands ===
716 716  
717 717  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -726,23 +726,19 @@
726 726  
727 727  * (% style="color:#037691" %)**AT Command:**
728 728  
729 -(% class="box infomessage" %)
730 -(((
731 731  **AT+TDC=N **
732 -)))
733 733  
725 +
734 734  **Example: **AT+TDC=30000. Means set interval to 30 seconds
735 735  
736 736  
737 737  * (% style="color:#037691" %)**Downlink Payload (prefix 0x01):**
738 738  
739 -(% class="box infomessage" %)
740 -(((
741 741  **0x01 aa bb cc     ~/~/ Same as AT+TDC=0x(aa bb cc)**
742 -)))
743 743  
744 744  
745 745  
735 +
746 746  ==== 3.4.2.2 Set Work Mode (AT+MOD) ====
747 747  
748 748  Set work mode.
... ... @@ -749,36 +749,29 @@
749 749  
750 750  * (% style="color:#037691" %)**AT Command:**
751 751  
752 -(% class="box infomessage" %)
753 -(((
754 754  **AT+MOD=N  **
755 -)))
756 756  
744 +
757 757  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
758 758  
759 759  
760 760  * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):**
761 761  
762 -(% class="box infomessage" %)
763 -(((
764 -**0x0A aa     ~/~/ Same as AT+MOD=aa**
765 -)))
750 +(% style="color:#037691" %)**​​​​​​​**(%%)**0x0A aa    ** ~/~/ Same as AT+MOD=aa
766 766  
767 767  
768 768  
754 +
769 769  ==== 3.4.2.3 Poll an uplink ====
770 770  
771 -* (% style="color:#037691" %)AT Command:
757 +* (% style="color:#037691" %)**AT Command:**
772 772  
773 773  There is no AT Command to poll uplink
774 774  
775 775  
776 -* (% style="color:#037691" %)Downlink Payload (prefix 0x08):
762 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x08):**
777 777  
778 -(% class="box infomessage" %)
779 -(((
780 -**0x08 FF     ~/~/ Poll an uplink,**
781 -)))
764 +**0x08 FF     **~/~/ Poll an uplink
782 782  
783 783  **Example**: 0x08FF, ask device to send an Uplink
784 784  
... ... @@ -788,12 +788,9 @@
788 788  
789 789  Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
790 790  
791 -* (% style="color:#037691" %)AT Command:
774 +* (% style="color:#037691" %)**AT Command:**
792 792  
793 -(% class="box infomessage" %)
794 -(((
795 795  **AT+ADDMOD6=1 or 0**
796 -)))
797 797  
798 798  1: Enable Trigger Mode
799 799  
... ... @@ -800,11 +800,13 @@
800 800  0: Disable Trigger Mode
801 801  
802 802  
803 -* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06):
783 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):**
804 804  
785 +**0x0A 06 aa    ** ~/~/ Same as AT+ADDMOD6=aa
786 +
805 805  (% class="box infomessage" %)
806 806  (((
807 -**0x0A 06 aa     ~/~/ Same as AT+ADDMOD6=aa,**
789 +
808 808  )))
809 809  
810 810  
... ... @@ -869,7 +869,6 @@
869 869  * **0x09 01 aa bb cc    ** ~/~/ same as AT+TRIG1=aa,0x(bb cc)
870 870  
871 871  
872 -
873 873  ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
874 874  
875 875  Set DI2 trigger.