Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -182,6 +182,7 @@ 182 182 * Counting 183 183 184 184 185 + 185 185 == 1.4 Applications == 186 186 187 187 * Smart Buildings & Home Automation ... ... @@ -192,6 +192,7 @@ 192 192 * Smart Factory 193 193 194 194 196 + 195 195 == 1.5 Hardware Variants == 196 196 197 197 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -206,8 +206,6 @@ 206 206 ))) 207 207 208 208 209 - 210 - 211 211 = 2. Power ON Device = 212 212 213 213 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -289,6 +289,7 @@ 289 289 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 290 290 291 291 292 + 292 292 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 293 293 294 294 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -343,6 +343,7 @@ 343 343 ** DO1 LED is off in both case 344 344 345 345 347 + 346 346 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 347 347 348 348 ... ... @@ -392,20 +392,24 @@ 392 392 393 393 ((( 394 394 **For LT22222-L:** 397 +))) 395 395 399 +(% class="box infomessage" %) 400 +((( 401 +((( 402 +**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 396 396 397 -**AT+TRIG1= 0,100lowlevel, valid signal is 100ms) **404 +**AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 398 398 399 -**AT+TRIG 1=1,1001port to trigger onhighlevel, valid signal is 100ms406 +**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 400 400 401 -**AT+TRIG2= 0,100lowlevel, valid signal is 100ms) **408 +**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 402 402 403 -**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 404 - 405 405 **AT+SETCNT=1,60 (Set COUNT1 value to 60)** 406 406 407 407 **AT+SETCNT=2,60 (Set COUNT2 value to 60)** 408 408 ))) 414 +))) 409 409 410 410 411 411 ... ... @@ -497,19 +497,22 @@ 497 497 498 498 499 499 **Plus below command for AVI1 Counting:** 506 +))) 500 500 508 +(% class="box infomessage" %) 509 +((( 510 +((( 511 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 501 501 502 -(% style="color:blue" %)**AT+ SETCNT=3,60**(%%)**(set AVICountto60)**513 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 503 503 504 -(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** higher than VOLMAX (20000mV =20v), counter increase 1)**515 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 505 505 506 -(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 507 - 508 -(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 517 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 509 509 ))) 519 +))) 510 510 511 511 512 - 513 513 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 514 514 515 515 ... ... @@ -569,7 +569,6 @@ 569 569 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 570 570 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 571 571 572 - 573 573 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 574 574 575 575 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -712,6 +712,7 @@ 712 712 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 713 713 714 714 723 + 715 715 === 3.4.1 Common Commands === 716 716 717 717 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -833,7 +833,10 @@ 833 833 834 834 * (% style="color:#037691" %)AT Command: 835 835 845 +(% class="box infomessage" %) 846 +((( 836 836 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 848 +))) 837 837 838 838 839 839 **Example:** ... ... @@ -842,11 +842,13 @@ 842 842 843 843 * (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 844 844 845 -**0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 857 +(% class="box infomessage" %) 858 +((( 859 +**0xAA 02 aa bb ~/~/ Same as AT+DTRI=aa,bb** 860 +))) 846 846 847 847 848 848 849 - 850 850 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 851 851 852 852 Set DI1 or DI3(for LT-33222-L) trigger. ... ... @@ -853,7 +853,10 @@ 853 853 854 854 * (% style="color:#037691" %)AT Command: 855 855 870 +(% class="box infomessage" %) 871 +((( 856 856 **AT+TRIG1=a,b** 873 +))) 857 857 858 858 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 859 859 ... ... @@ -865,11 +865,15 @@ 865 865 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 866 866 867 867 868 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 869 -* **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 885 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 01 ): 870 870 887 +(% class="box infomessage" %) 888 +((( 889 +**0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 890 +))) 871 871 872 872 893 + 873 873 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 874 874 875 875 Set DI2 trigger. ... ... @@ -891,7 +891,7 @@ 891 891 892 892 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):** 893 893 894 -**0x09 02 aa bb cc **~/~/ same as AT+TRIG1=aa,0x(bb cc)915 +**0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 895 895 896 896 897 897 ... ... @@ -907,7 +907,7 @@ 907 907 908 908 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )** 909 909 910 -**0x AA 01 aa bb cc dd ee ff gg hh 931 +**0x AA 01 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 911 911 912 912 913 913 ... ... @@ -923,7 +923,7 @@ 923 923 924 924 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )** 925 925 926 -**0x AA 00 aa bb cc dd ee ff gg hh 947 +**0x AA 00 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 927 927 928 928 929 929 ... ... @@ -939,7 +939,7 @@ 939 939 940 940 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** 941 941 942 -**0x AC aa bb 963 +**0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 943 943 944 944 945 945 ... ... @@ -954,6 +954,7 @@ 954 954 * (% style="color:#037691" %)**Downlink Payload (prefix 0x02)** 955 955 * **0x02 aa bb cc **~/~/ Set DO1/DO2/DO3 output 956 956 978 + 957 957 ((( 958 958 If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low. 959 959 ))) ... ... @@ -1130,7 +1130,7 @@ 1130 1130 1131 1131 * (% style="color:#037691" %)**AT Command:** 1132 1132 1133 -**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1155 +(% style="color:#037691" %)****(%%)**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1134 1134 1135 1135 1136 1136 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):**