Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -1,7 +1,6 @@ 1 1 (% style="text-align:center" %) 2 2 [[image:image-20220523163353-1.jpeg||height="604" width="500"]] 3 3 4 -**LT-22222-L LoRa IO Controller User Manual ** 5 5 6 6 7 7 **Table of Contents:** ... ... @@ -167,7 +167,6 @@ 167 167 Packet engine up to 256 bytes with CRC. 168 168 169 169 170 - 171 171 172 172 ))) 173 173 ... ... @@ -181,7 +181,6 @@ 181 181 * Firmware upgradable via program port 182 182 * Counting 183 183 184 - 185 185 == 1.4 Applications == 186 186 187 187 * Smart Buildings & Home Automation ... ... @@ -191,7 +191,6 @@ 191 191 * Smart Cities 192 192 * Smart Factory 193 193 194 - 195 195 == 1.5 Hardware Variants == 196 196 197 197 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -205,9 +205,6 @@ 205 205 * 1 x Counting Port 206 206 ))) 207 207 208 - 209 - 210 - 211 211 = 2. Power ON Device = 212 212 213 213 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -225,11 +225,11 @@ 225 225 == 3.1 How it works? == 226 226 227 227 ((( 228 -The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on **TX LED** will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. **TX LED** will be on for 5 seconds after joined in network. When there is message from server, the **RX LED**will be on for 1 second.221 +The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%) will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. (% style="color:green" %)**TX LED**(%%) will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second. 229 229 ))) 230 230 231 231 ((( 232 -In case user can ’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.225 +In case user can't set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 233 233 ))) 234 234 235 235 ... ... @@ -281,14 +281,13 @@ 281 281 282 282 There are five working modes + one interrupt mode on LT for different type application: 283 283 284 -* **MOD1**: (default setting): 2 x ACI + 2AVI + DI + DO + RO 285 -* **MOD2**: Double DI Counting + DO + RO 286 -* **MOD3**: Single DI Counting + 2 x ACI + DO + RO 287 -* **MOD4**: Single DI Counting + 1 x Voltage Counting + DO + RO 288 -* **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 289 -* **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 277 +* (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO 278 +* (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO 279 +* (% style="color:blue" %)**MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO 280 +* (% style="color:blue" %)**MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO 281 +* (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 282 +* (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5 290 290 291 - 292 292 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 293 293 294 294 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -342,7 +342,6 @@ 342 342 ** DO1 is high in case there is load between DO1 and V+. 343 343 ** DO1 LED is off in both case 344 344 345 - 346 346 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 347 347 348 348 ... ... @@ -392,24 +392,20 @@ 392 392 393 393 ((( 394 394 **For LT22222-L:** 395 -))) 396 396 397 -(% class="box infomessage" %) 398 -((( 399 -((( 400 -**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 401 401 402 -**AT+TRIG1= 1,100 (set DI1 port to trigger onhighlevel, valid signal is 100ms388 +(% style="color:blue" %)**AT+TRIG1=0,100**(%%)** (set DI1 port to trigger on low level, valid signal is 100ms) ** 403 403 404 -**AT+TRIG 2=0,100 (set DI2port to trigger onlowlevel, valid signal is 100ms) **390 +(% style="color:blue" %)**AT+TRIG1=1,100**(%%)** (set DI1 port to trigger on high level, valid signal is 100ms ) ** 405 405 406 -**AT+TRIG2= 1,100 (set DI2 port to trigger onhighlevel, valid signal is 100ms392 +(% style="color:blue" %)**AT+TRIG2=0,100**(%%)** (set DI2 port to trigger on low level, valid signal is 100ms) ** 407 407 408 -**AT+ SETCNT=1,60SetCOUNT1valueto60)**394 +(% style="color:blue" %)**AT+TRIG2=1,100**(%%)** (set DI2 port to trigger on high level, valid signal is 100ms ) ** 409 409 410 -**AT+SETCNT=2,60 (Set COUNT2 value to 60)** 396 +(% style="color:blue" %)**AT+SETCNT=1,60**(%%)** (Set COUNT1 value to 60)** 397 + 398 +(% style="color:blue" %)**AT+SETCNT=2,60**(%%)** (Set COUNT2 value to 60)** 411 411 ))) 412 -))) 413 413 414 414 415 415 ... ... @@ -420,6 +420,8 @@ 420 420 [[image:image-20220523181246-5.png]] 421 421 422 422 ((( 410 + 411 + 423 423 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 424 424 ))) 425 425 ... ... @@ -433,6 +433,7 @@ 433 433 (% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 434 434 ))) 435 435 425 + 436 436 ((( 437 437 **To use counting mode, please run:** 438 438 ))) ... ... @@ -565,8 +565,8 @@ 565 565 566 566 For example, if user has configured below commands: 567 567 568 -* **AT+MOD=1 ** **~-~->** The normal working mode 569 -* **AT+ADDMOD6=1** **~-~->** Enable trigger 558 +* **AT+MOD=1 ** **~-~->** The normal working mode 559 +* **AT+ADDMOD6=1** **~-~->** Enable trigger 570 570 571 571 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 572 572 ... ... @@ -573,9 +573,9 @@ 573 573 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 574 574 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 575 575 576 - 577 577 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 578 578 568 + 579 579 (% style="color:#4f81bd" %)**Trigger base on voltage**: 580 580 581 581 Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH> ... ... @@ -715,7 +715,6 @@ 715 715 716 716 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 717 717 718 - 719 719 === 3.4.1 Common Commands === 720 720 721 721 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -724,6 +724,7 @@ 724 724 725 725 === 3.4.2 Sensor related commands === 726 726 716 + 727 727 ==== 3.4.2.1 Set Transmit Interval ==== 728 728 729 729 Set device uplink interval. ... ... @@ -730,23 +730,19 @@ 730 730 731 731 * (% style="color:#037691" %)**AT Command:** 732 732 733 -(% class="box infomessage" %) 734 -((( 735 735 **AT+TDC=N ** 736 -))) 737 737 725 + 738 738 **Example: **AT+TDC=30000. Means set interval to 30 seconds 739 739 740 740 741 741 * (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 742 742 743 -(% class="box infomessage" %) 744 -((( 745 745 **0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 746 -))) 747 747 748 748 749 749 735 + 750 750 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 751 751 752 752 Set work mode. ... ... @@ -753,51 +753,42 @@ 753 753 754 754 * (% style="color:#037691" %)**AT Command:** 755 755 756 -(% class="box infomessage" %) 757 -((( 758 758 **AT+MOD=N ** 759 -))) 760 760 744 + 761 761 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 762 762 763 763 764 764 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 765 765 766 -(% class="box infomessage" %) 767 -((( 768 -**0x0A aa ~/~/ Same as AT+MOD=aa** 769 -))) 750 +**0x0A aa ** ~/~/ Same as AT+MOD=aa 770 770 771 771 772 772 754 + 773 773 ==== 3.4.2.3 Poll an uplink ==== 774 774 775 -* (% style="color:#037691" %)AT Command: 757 +* (% style="color:#037691" %)**AT Command:** 776 776 777 777 There is no AT Command to poll uplink 778 778 779 779 780 -* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 762 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x08):** 781 781 782 -(% class="box infomessage" %) 783 -((( 784 -**0x08 FF ~/~/ Poll an uplink,** 785 -))) 764 +**0x08 FF **~/~/ Poll an uplink 786 786 787 787 **Example**: 0x08FF, ask device to send an Uplink 788 788 789 789 790 790 770 + 791 791 ==== 3.4.2.4 Enable Trigger Mode ==== 792 792 793 793 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 794 794 795 -* (% style="color:#037691" %)AT Command: 775 +* (% style="color:#037691" %)**AT Command:** 796 796 797 -(% class="box infomessage" %) 798 -((( 799 799 **AT+ADDMOD6=1 or 0** 800 -))) 801 801 802 802 1: Enable Trigger Mode 803 803 ... ... @@ -804,38 +804,34 @@ 804 804 0: Disable Trigger Mode 805 805 806 806 807 -* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 784 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):** 808 808 809 -(% class="box infomessage" %) 810 -((( 811 -**0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 812 -))) 786 +**0x0A 06 aa ** ~/~/ Same as AT+ADDMOD6=aa 813 813 814 814 815 815 790 + 816 816 ==== 3.4.2.5 Poll trigger settings ==== 817 817 818 818 Poll trigger settings, 819 819 820 -* (% style="color:#037691" %)AT Command: 795 +* (% style="color:#037691" %)**AT Command:** 821 821 822 822 There is no AT Command for this feature. 823 823 824 824 825 -* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 800 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):** 826 826 827 -(% class="box infomessage" %) 828 -((( 829 -**0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 830 -))) 802 +**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 831 831 832 832 833 833 806 + 834 834 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 835 835 836 836 Enable Disable DI1/DI2/DI2 as trigger, 837 837 838 -* (% style="color:#037691" %)AT Command: 811 +* (% style="color:#037691" %)**AT Command:** 839 839 840 840 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 841 841 ... ... @@ -844,7 +844,7 @@ 844 844 845 845 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 846 846 847 -* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 820 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):** 848 848 849 849 **0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 850 850 ... ... @@ -855,7 +855,7 @@ 855 855 856 856 Set DI1 or DI3(for LT-33222-L) trigger. 857 857 858 -* (% style="color:#037691" %)AT Command: 831 +* (% style="color:#037691" %)**AT Command:** 859 859 860 860 **AT+TRIG1=a,b** 861 861 ... ... @@ -872,8 +872,6 @@ 872 872 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 873 873 * **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 874 874 875 - 876 - 877 877 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 878 878 879 879 Set DI2 trigger. ... ... @@ -934,11 +934,11 @@ 934 934 935 935 ==== 3.4.2.11 Trigger – Set minimum interval ==== 936 936 937 -Set AV and AC trigger minimum interval, system won ’t response to the second trigger within this set time after the first trigger.908 +Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger. 938 938 939 939 * (% style="color:#037691" %)**AT Command** 940 940 941 -**AT+ATDC=5 .Device won’t response the second trigger within 5 minute after the first trigger.**912 +**AT+ATDC=5 ** Device won't response the second trigger within 5 minute after the first trigger. 942 942 943 943 944 944 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** ... ... @@ -945,9 +945,15 @@ 945 945 946 946 **0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 947 947 919 +((( 920 + 948 948 922 +(% style="color:red" %)Note: ATDC setting must be more than 5min 923 +))) 949 949 950 950 926 + 927 + 951 951 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 952 952 953 953 * (% style="color:#037691" %)**AT Command** ... ... @@ -1099,7 +1099,7 @@ 1099 1099 1100 1100 (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status: 1101 1101 1102 -[[image:image-20220 524093831-10.png]]1079 +[[image:image-20220714135731-1.png||height="406" width="627"]] 1103 1103 1104 1104 1105 1105 (% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms ... ... @@ -1109,21 +1109,21 @@ 1109 1109 1110 1110 **Example payload:** 1111 1111 1112 -**~1. 05 01 11 07 D 0**1089 +**~1. 05 01 11 07 D** 1113 1113 1114 -Relay1 and Relay 2 will be set to N O, last 2 seconds, then change back to original state.1091 +Relay1 and Relay 2 will be set to NC , last 2 seconds, then change back to original state. 1115 1115 1116 1116 **2. 05 01 10 07 D0** 1117 1117 1118 -Relay1 will change to N O, Relay2 will change to NC, last 2 seconds, then both change back to original state.1095 +Relay1 will change to NC, Relay2 will change to NO, last 2 seconds, then both change back to original state. 1119 1119 1120 1120 **3. 05 00 01 07 D0** 1121 1121 1122 -Relay1 will change to N C, Relay2 will change to NO, last 2 seconds, then relay change to NO,C.1099 +Relay1 will change to NO, Relay2 will change to NC, last 2 seconds, then relay change to NC,Relay2 change to NO. 1123 1123 1124 1124 **4. 05 00 00 07 D0** 1125 1125 1126 -Relay 1 & relay2 will change to N C, last 2 seconds, then both change to NO.1103 +Relay 1 & relay2 will change to NO, last 2 seconds, then both change to NC. 1127 1127 1128 1128 1129 1129 ... ... @@ -1148,7 +1148,7 @@ 1148 1148 1149 1149 * (% style="color:#037691" %)**AT Command:** 1150 1150 1151 - (% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) **1128 +**AT+SETCNT=aa,(bb cc dd ee) ** 1152 1152 1153 1153 aa: 1: Set count1, 1154 1154 ... ... @@ -1172,7 +1172,7 @@ 1172 1172 1173 1173 * (% style="color:#037691" %)**AT Command:** 1174 1174 1175 - (% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting1152 +**AT+CLRCOUNT ** ~/~/ clear all counting 1176 1176 1177 1177 1178 1178 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** ... ... @@ -1213,12 +1213,11 @@ 1213 1213 (% style="color:blue" %)**Step 2**(%%): To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps: 1214 1214 ))) 1215 1215 1216 -[[image:1 653356737703-362.png||height="232" width="732"]]1193 +[[image:image-20220719105525-1.png||height="377" width="677"]] 1217 1217 1218 -[[image:image-20220524094641-11.png||height="390" width="723"]] 1219 1219 1220 1220 1221 -[[image:image-20220 524094641-12.png||height="402" width="718"]]1197 +[[image:image-20220719110247-2.png||height="388" width="683"]] 1222 1222 1223 1223 1224 1224 (% style="color:blue" %)**Step 3**(%%): Create an account or log in Mydevices. ... ... @@ -1430,6 +1430,7 @@ 1430 1430 [[image:image-20220524100748-11.png]] 1431 1431 1432 1432 1409 + 1433 1433 = 4. Use AT Command = 1434 1434 1435 1435 == 4.1 Access AT Command == ... ... @@ -1632,8 +1632,6 @@ 1632 1632 1633 1633 ((( 1634 1634 AT+CFG: Print all settings 1635 - 1636 - 1637 1637 ))) 1638 1638 1639 1639 ... ... @@ -1679,8 +1679,6 @@ 1679 1679 1680 1680 ((( 1681 1681 (% style="background-color:#dcdcdc" %)ATZ 1682 - 1683 - 1684 1684 ))) 1685 1685 1686 1686 ... ... @@ -1793,7 +1793,7 @@ 1793 1793 1794 1794 1795 1795 (% style="color:blue" %)**For LT-22222-L**(%%): 1796 -Hold down the PRO button and then momentarily press the RST reset button and the **DO1 led** will change from OFF to ON. When **DO1 LED** is on, it means the device is in download mode. 1769 +Hold down the PRO button and then momentarily press the RST reset button and the (% style="color:red" %)**DO1 led**(%%) will change from OFF to ON. When (% style="color:red" %)**DO1 LED**(%%) is on, it means the device is in download mode. 1797 1797 ))) 1798 1798 1799 1799 [[image:image-20220524103407-12.png]] ... ... @@ -1887,6 +1887,8 @@ 1887 1887 == 5.5 Can i use point to point communication for LT-22222-L? == 1888 1888 1889 1889 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1863 + 1864 + 1890 1890 ))) 1891 1891 1892 1892 ((( ... ... @@ -1900,12 +1900,13 @@ 1900 1900 1901 1901 After restart, the status before power failure will be read from flash. 1902 1902 1878 + 1903 1903 = 6. Trouble Shooting = 1904 1904 ))) 1905 1905 1906 1906 ((( 1907 1907 ((( 1908 -== 6.1 Downlink doesn ’t work, how to solve it? ==1884 +== 6.1 Downlink doesn't work, how to solve it? == 1909 1909 ))) 1910 1910 ))) 1911 1911 ... ... @@ -1926,7 +1926,7 @@ 1926 1926 ((( 1927 1927 1928 1928 1929 -== 6.3 Why I can ’t join TTN in US915 /AU915 bands? ==1905 +== 6.3 Why I can't join TTN in US915 /AU915 bands? == 1930 1930 ))) 1931 1931 1932 1932 ((( ... ... @@ -1934,25 +1934,24 @@ 1934 1934 ))) 1935 1935 1936 1936 1937 - 1938 1938 = 7. Order Info = 1939 1939 1940 1940 1941 1941 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1942 1942 1943 - 1944 1944 (% style="color:#4f81bd" %)**XXX:** 1945 1945 1946 -* (% style="color: #4f81bd" %)**EU433**(%%): LT with frequency bands EU4331947 -* (% style="color: #4f81bd" %)**EU868**(%%): LT with frequency bands EU8681948 -* (% style="color: #4f81bd" %)**KR920**(%%): LT with frequency bands KR9201949 -* (% style="color: #4f81bd" %)**CN470**(%%): LT with frequency bands CN4701950 -* (% style="color: #4f81bd" %)**AS923**(%%): LT with frequency bands AS9231951 -* (% style="color: #4f81bd" %)**AU915**(%%): LT with frequency bands AU9151952 -* (% style="color: #4f81bd" %)**US915**(%%): LT with frequency bands US9151953 -* (% style="color: #4f81bd" %)**IN865**(%%): LT with frequency bands IN8651954 -* (% style="color: #4f81bd" %)**CN779**(%%): LT with frequency bands CN7791920 +* (% style="color:red" %)**EU433**(%%): LT with frequency bands EU433 1921 +* (% style="color:red" %)**EU868**(%%): LT with frequency bands EU868 1922 +* (% style="color:red" %)**KR920**(%%): LT with frequency bands KR920 1923 +* (% style="color:red" %)**CN470**(%%): LT with frequency bands CN470 1924 +* (% style="color:red" %)**AS923**(%%): LT with frequency bands AS923 1925 +* (% style="color:red" %)**AU915**(%%): LT with frequency bands AU915 1926 +* (% style="color:red" %)**US915**(%%): LT with frequency bands US915 1927 +* (% style="color:red" %)**IN865**(%%): LT with frequency bands IN865 1928 +* (% style="color:red" %)**CN779**(%%): LT with frequency bands CN779 1955 1955 1930 + 1956 1956 = 8. Packing Info = 1957 1957 1958 1958 ... ... @@ -1970,6 +1970,7 @@ 1970 1970 * Package Size / pcs : 14.5 x 8 x 5 cm 1971 1971 * Weight / pcs : 170g 1972 1972 1948 + 1973 1973 = 9. Support = 1974 1974 1975 1975 * (((
- image-20220714135731-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +54.1 KB - Content
- image-20220719105525-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +165.5 KB - Content
- image-20220719110247-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +52.9 KB - Content