... ... @@ -397,13 +397,13 @@
397 397  (% class="box infomessage" %)
398 398  (((
399 399  (((
400 -**AT+TRIG1=0,100  (set DI1 port to trigger on low level, valid signal is 100ms) **
400 +**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) **
401 401  
402 -**AT+TRIG1=1,100  (set DI1 port to trigger on high level, valid signal is 100ms ) **
402 +**AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) **
403 403  
404 -**AT+TRIG2=0,100  (set DI2 port to trigger on low level, valid signal is 100ms) **
404 +**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) **
405 405  
406 -**AT+TRIG2=1,100  (set DI2 port to trigger on high level, valid signal is 100ms ) **
406 +**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) **
407 407  
408 408  **AT+SETCNT=1,60   (Set COUNT1 value to 60)**
409 409  
... ... @@ -501,19 +501,22 @@
501 501  
502 502  
503 503  **Plus below command for AVI1 Counting:**
504 +)))
504 504  
506 +(% class="box infomessage" %)
507 +(((
508 +(((
509 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)**   (set AVI Count to 60)**
505 505  
506 -(% style="color:blue" %)**AT+SETCNT=3,60**(%%)**  (set AVI Count to 60)**
511 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)**   (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)**
507 507  
508 -(% style="color:blue" %)**AT+VOLMAX=20000**(%%)**  (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)**
513 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)**   (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)**
509 509  
510 -(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)**  (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)**
511 -
512 -(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)**  (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)**
515 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)**   (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)**
513 513  )))
517 +)))
514 514  
515 515  
516 -
517 517  === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI ===
518 518  
519 519  
... ... @@ -573,7 +573,6 @@
573 573  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
574 574  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
575 575  
576 -
577 577  (% style="color:#037691" %)**AT Command to set Trigger Condition**:
578 578  
579 579  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -1134,7 +1134,7 @@
1134 1134  
1135 1135  * (% style="color:#037691" %)**AT Command:**
1136 1136  
1137 -**AT+VOLMAX   ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1139 +(% style="color:#037691" %)**​​​​​​​**(%%)**AT+VOLMAX   ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1138 1138  
1139 1139  
1140 1140  * (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):**