Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -397,13 +397,13 @@ 397 397 (% class="box infomessage" %) 398 398 ((( 399 399 ((( 400 -**AT+TRIG1=0,100 400 +**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 401 401 402 -**AT+TRIG1=1,100 402 +**AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 403 403 404 -**AT+TRIG2=0,100 404 +**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 405 405 406 -**AT+TRIG2=1,100 406 +**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 407 407 408 408 **AT+SETCNT=1,60 (Set COUNT1 value to 60)** 409 409 ... ... @@ -501,19 +501,22 @@ 501 501 502 502 503 503 **Plus below command for AVI1 Counting:** 504 +))) 504 504 506 +(% class="box infomessage" %) 507 +((( 508 +((( 509 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 505 505 506 -(% style="color:blue" %)**AT+ SETCNT=3,60**(%%)**(set AVICountto60)**511 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 507 507 508 -(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** higher than VOLMAX (20000mV =20v), counter increase 1)**513 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 509 509 510 -(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 511 - 512 -(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 515 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 513 513 ))) 517 +))) 514 514 515 515 516 - 517 517 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 518 518 519 519 ... ... @@ -573,7 +573,6 @@ 573 573 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 574 574 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 575 575 576 - 577 577 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 578 578 579 579 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -1134,7 +1134,7 @@ 1134 1134 1135 1135 * (% style="color:#037691" %)**AT Command:** 1136 1136 1137 -**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1139 +(% style="color:#037691" %)****(%%)**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1138 1138 1139 1139 1140 1140 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):**