... ... @@ -19,8 +19,6 @@
19 19  == 1.1 What is LT Series I/O Controller ==
20 20  
21 21  (((
22 -
23 -
24 24  The Dragino (% style="color:blue" %)**LT series I/O Modules**(%%) are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (% style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %), **relay output**, **digital input**(%%) and (% style="color:blue" %)**digital output**(%%) etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring.
25 25  )))
26 26  
... ... @@ -50,7 +50,6 @@
50 50  
51 51  )))
52 52  
53 -
54 54  == 1.2  Specifications ==
55 55  
56 56  (((
... ... @@ -79,8 +79,6 @@
79 79  )))
80 80  
81 81  (((
82 -
83 -
84 84  **Interface for Model: LT22222-L:**
85 85  )))
86 86  
... ... @@ -104,8 +104,6 @@
104 104  )))
105 105  
106 106  (((
107 -
108 -
109 109  **LoRa Spec:**
110 110  )))
111 111  
... ... @@ -166,8 +166,6 @@
166 166  * (((
167 167  Packet engine up to 256 bytes with CRC.
168 168  
169 -
170 -
171 171  
172 172  )))
173 173  
... ... @@ -181,7 +181,6 @@
181 181  * Firmware upgradable via program port
182 182  * Counting
183 183  
184 -
185 185  == 1.4  Applications ==
186 186  
187 187  * Smart Buildings & Home Automation
... ... @@ -191,7 +191,6 @@
191 191  * Smart Cities
192 192  * Smart Factory
193 193  
194 -
195 195  == 1.5 Hardware Variants ==
196 196  
197 197  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -205,9 +205,6 @@
205 205  * 1 x Counting Port
206 206  )))
207 207  
208 -
209 -
210 -
211 211  = 2. Power ON Device =
212 212  
213 213  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -230,9 +230,12 @@
230 230  
231 231  (((
232 232  In case user can’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.
219 +
220 +
233 233  )))
234 234  
235 235  
224 +
236 236  == 3.2 Example to join LoRaWAN network ==
237 237  
238 238  (((
... ... @@ -241,13 +241,12 @@
241 241  
242 242  [[image:image-20220523172350-1.png||height="266" width="864"]]
243 243  
244 -
245 245  (((
246 246  The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN:
247 247  )))
248 248  
249 249  (((
250 -(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller.
238 +**Step 1**: Create a device in TTN with the OTAA keys from LT IO controller.
251 251  )))
252 252  
253 253  (((
... ... @@ -256,7 +256,6 @@
256 256  
257 257  [[image:1653297924498-393.png]]
258 258  
259 -
260 260  Input these keys in the LoRaWAN Server portal. Below is TTN screen shot:
261 261  
262 262  Add APP EUI in the application.
... ... @@ -270,7 +270,7 @@
270 270  
271 271  
272 272  (((
273 -(% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
260 +**Step 2**: Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
274 274  )))
275 275  
276 276  [[image:1653298044601-602.png||height="405" width="709"]]
... ... @@ -288,7 +288,6 @@
288 288  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
289 289  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
290 290  
291 -
292 292  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
293 293  
294 294  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -296,8 +296,6 @@
296 296  [[image:image-20220523174024-3.png]]
297 297  
298 298  (((
299 -
300 -
301 301  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
302 302  )))
303 303  
... ... @@ -311,7 +311,6 @@
311 311  
312 312  For example if payload is: [[image:image-20220523175847-2.png]]
313 313  
314 -
315 315  **The value for the interface is:  **
316 316  
317 317  AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V
... ... @@ -342,10 +342,8 @@
342 342  ** DO1 is high in case there is load between DO1 and V+.
343 343  ** DO1 LED is off in both case
344 344  
345 -
346 346  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
347 347  
348 -
349 349  **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins.
350 350  
351 351  (((
... ... @@ -354,7 +354,6 @@
354 354  
355 355  [[image:image-20220523180452-3.png]]
356 356  
357 -
358 358  (((
359 359  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below
360 360  )))
... ... @@ -370,8 +370,6 @@
370 370  )))
371 371  
372 372  (((
373 -
374 -
375 375  **To use counting mode, please run:**
376 376  )))
377 377  
... ... @@ -379,14 +379,17 @@
379 379  (((
380 380  (((
381 381  **AT+MOD=2**
360 +)))
361 +)))
382 382  
363 +(% class="box infomessage" %)
364 +(((
365 +(((
383 383  **ATZ**
384 384  )))
385 385  )))
386 386  
387 387  (((
388 -
389 -
390 390  (% style="color:#4f81bd" %)**AT Commands for counting:**
391 391  )))
392 392  
... ... @@ -397,16 +397,41 @@
397 397  (% class="box infomessage" %)
398 398  (((
399 399  (((
400 -**AT+TRIG1=0,100  (set DI1 port to trigger on low level, valid signal is 100ms) **
381 +**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) **
382 +)))
383 +)))
401 401  
402 -**AT+TRIG1=1,100  (set DI1 port to trigger on high level, valid signal is 100ms ) **
385 +(% class="box infomessage" %)
386 +(((
387 +(((
388 +**AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) **
389 +)))
390 +)))
403 403  
404 -**AT+TRIG2=0,100  (set DI2 port to trigger on low level, valid signal is 100ms) **
392 +(% class="box infomessage" %)
393 +(((
394 +(((
395 +**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) **
396 +)))
397 +)))
405 405  
406 -**AT+TRIG2=1,100  (set DI2 port to trigger on high level, valid signal is 100ms ) **
399 +(% class="box infomessage" %)
400 +(((
401 +(((
402 +**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) **
403 +)))
404 +)))
407 407  
406 +(% class="box infomessage" %)
407 +(((
408 +(((
408 408  **AT+SETCNT=1,60   (Set COUNT1 value to 60)**
410 +)))
411 +)))
409 409  
413 +(% class="box infomessage" %)
414 +(((
415 +(((
410 410  **AT+SETCNT=2,60   (Set COUNT2 value to 60)**
411 411  )))
412 412  )))
... ... @@ -441,7 +441,12 @@
441 441  (((
442 442  (((
443 443  **AT+MOD=3**
450 +)))
451 +)))
444 444  
453 +(% class="box infomessage" %)
454 +(((
455 +(((
445 445  **ATZ**
446 446  )))
447 447  )))
... ... @@ -448,6 +448,8 @@
448 448  
449 449  (((
450 450  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
462 +
463 +
451 451  )))
452 452  
453 453  
... ... @@ -454,7 +454,6 @@
454 454  
455 455  === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting ===
456 456  
457 -
458 458  **LT22222-L**: This mode the DI1 is used as a counting pin.
459 459  
460 460  The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour.
... ... @@ -461,7 +461,6 @@
461 461  
462 462  [[image:image-20220523181903-8.png]]
463 463  
464 -
465 465  (((
466 466  (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
467 467  )))
... ... @@ -477,8 +477,6 @@
477 477  )))
478 478  
479 479  (((
480 -
481 -
482 482  **To use this mode, please run:**
483 483  )))
484 484  
... ... @@ -486,37 +486,60 @@
486 486  (((
487 487  (((
488 488  **AT+MOD=4**
498 +)))
499 +)))
489 489  
501 +(% class="box infomessage" %)
502 +(((
503 +(((
490 490  **ATZ**
491 491  )))
492 492  )))
493 493  
508 +(((
509 +
510 +)))
494 494  
495 -
496 496  (((
497 497  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
498 498  )))
499 499  
500 500  (((
501 -
502 -
503 503  **Plus below command for AVI1 Counting:**
518 +)))
504 504  
520 +(% class="box infomessage" %)
521 +(((
522 +(((
523 +**AT+SETCNT=3,60   (set AVI Count to 60)**
524 +)))
525 +)))
505 505  
506 -(% style="color:blue" %)**AT+SETCNT=3,60**(%%)**  (set AVI Count to 60)**
527 +(% class="box infomessage" %)
528 +(((
529 +(((
530 +**AT+VOLMAX=20000   (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)**
531 +)))
532 +)))
507 507  
508 -(% style="color:blue" %)**AT+VOLMAX=20000**(%%)**  (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)**
534 +(% class="box infomessage" %)
535 +(((
536 +(((
537 +**AT+VOLMAX=20000,0   (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)**
538 +)))
539 +)))
509 509  
510 -(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)**  (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)**
511 -
512 -(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)**  (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)**
541 +(% class="box infomessage" %)
542 +(((
543 +(((
544 +**AT+VOLMAX=20000,1   (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)**
513 513  )))
546 +)))
514 514  
515 515  
516 516  
517 517  === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI ===
518 518  
519 -
520 520  **LT22222-L**: This mode the DI1 is used as a counting pin.
521 521  
522 522  [[image:image-20220523182334-9.png]]
... ... @@ -547,7 +547,12 @@
547 547  (((
548 548  (((
549 549  **AT+MOD=5**
582 +)))
583 +)))
550 550  
585 +(% class="box infomessage" %)
586 +(((
587 +(((
551 551  **ATZ**
552 552  )))
553 553  )))
... ... @@ -560,7 +560,6 @@
560 560  
561 561  === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) ===
562 562  
563 -
564 564  (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.**
565 565  
566 566  For example, if user has configured below commands:
... ... @@ -568,6 +568,7 @@
568 568  * **AT+MOD=1 ** **~-~->** The normal working mode
569 569  * **AT+ADDMOD6=1**   **~-~->** Enable trigger
570 570  
607 +
571 571  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
572 572  
573 573  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
... ... @@ -574,7 +574,7 @@
574 574  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
575 575  
576 576  
577 -(% style="color:#037691" %)**AT Command to set Trigger Condition**:
614 +**AT Command to set Trigger Condition**:
578 578  
579 579  (% style="color:#4f81bd" %)**Trigger base on voltage**:
580 580  
... ... @@ -587,7 +587,6 @@
587 587  AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
588 588  
589 589  
590 -
591 591  (% style="color:#4f81bd" %)**Trigger base on current**:
592 592  
593 593  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
... ... @@ -597,7 +597,6 @@
597 597  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
598 598  
599 599  
600 -
601 601  (% style="color:#4f81bd" %)**Trigger base on DI status**:
602 602  
603 603  DI status trigger Flag.
... ... @@ -604,13 +604,12 @@
604 604  
605 605  Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >
606 606  
607 -
608 608  **Example:**
609 609  
610 610  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
611 611  
612 612  
613 -(% style="color:#037691" %)**Downlink Command to set Trigger Condition:**
647 +**Downlink Command to set Trigger Condition**
614 614  
615 615  Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM**
616 616  
... ... @@ -639,7 +639,6 @@
639 639  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
640 640  
641 641  
642 -
643 643  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
644 644  
645 645  MOD6 Payload : total 11 bytes payload
... ... @@ -653,6 +653,7 @@
653 653  
654 654  * Each bits shows if the corresponding trigger has been configured.
655 655  
689 +
656 656  **Example:**
657 657  
658 658  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -664,6 +664,7 @@
664 664  
665 665  * Each bits shows which status has been trigger on this uplink.
666 666  
701 +
667 667  **Example:**
668 668  
669 669  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -675,6 +675,7 @@
675 675  
676 676  * Each bits shows which status has been trigger on this uplink.
677 677  
713 +
678 678  **Example:**
679 679  
680 680  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -695,8 +695,6 @@
695 695  === 3.3.7 Payload Decoder ===
696 696  
697 697  (((
698 -
699 -
700 700  **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]]
701 701  
702 702  
... ... @@ -703,6 +703,7 @@
703 703  )))
704 704  
705 705  
740 +
706 706  == 3.4 ​Configure LT via AT or Downlink ==
707 707  
708 708  User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands
... ... @@ -716,6 +716,7 @@
716 716  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
717 717  
718 718  
754 +
719 719  === 3.4.1 Common Commands ===
720 720  
721 721  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -728,7 +728,7 @@
728 728  
729 729  Set device uplink interval.
730 730  
731 -* (% style="color:#037691" %)**AT Command:**
767 +* AT Command:
732 732  
733 733  (% class="box infomessage" %)
734 734  (((
... ... @@ -738,7 +738,7 @@
738 738  **Example: **AT+TDC=30000. Means set interval to 30 seconds
739 739  
740 740  
741 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x01):**
777 +* Downlink Payload (prefix 0x01):
742 742  
743 743  (% class="box infomessage" %)
744 744  (((
... ... @@ -751,7 +751,7 @@
751 751  
752 752  Set work mode.
753 753  
754 -* (% style="color:#037691" %)**AT Command:**
790 +* AT Command:
755 755  
756 756  (% class="box infomessage" %)
757 757  (((
... ... @@ -761,7 +761,7 @@
761 761  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
762 762  
763 763  
764 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):**
800 +* Downlink Payload (prefix 0x0A):
765 765  
766 766  (% class="box infomessage" %)
767 767  (((
... ... @@ -772,12 +772,12 @@
772 772  
773 773  ==== 3.4.2.3 Poll an uplink ====
774 774  
775 -* (% style="color:#037691" %)AT Command:
811 +* AT Command:
776 776  
777 777  There is no AT Command to poll uplink
778 778  
779 779  
780 -* (% style="color:#037691" %)Downlink Payload (prefix 0x08):
816 +* Downlink Payload (prefix 0x08):
781 781  
782 782  (% class="box infomessage" %)
783 783  (((
... ... @@ -792,7 +792,7 @@
792 792  
793 793  Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
794 794  
795 -* (% style="color:#037691" %)AT Command:
831 +* AT Command:
796 796  
797 797  (% class="box infomessage" %)
798 798  (((
... ... @@ -804,7 +804,7 @@
804 804  0: Disable Trigger Mode
805 805  
806 806  
807 -* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06):
843 +* Downlink Payload (prefix 0x0A 06):
808 808  
809 809  (% class="box infomessage" %)
810 810  (((
... ... @@ -817,12 +817,12 @@
817 817  
818 818  Poll trigger settings,
819 819  
820 -* (% style="color:#037691" %)AT Command:
856 +* AT Command:
821 821  
822 822  There is no AT Command for this feature.
823 823  
824 824  
825 -* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06):
861 +* Downlink Payload (prefix 0x AB 06):
826 826  
827 827  (% class="box infomessage" %)
828 828  (((
... ... @@ -835,9 +835,12 @@
835 835  
836 836  Enable Disable DI1/DI2/DI2 as trigger,
837 837  
838 -* (% style="color:#037691" %)AT Command:
874 +* AT Command:
839 839  
876 +(% class="box infomessage" %)
877 +(((
840 840  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
879 +)))
841 841  
842 842  
843 843  **Example:**
... ... @@ -844,20 +844,25 @@
844 844  
845 845  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
846 846  
847 -* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02):
886 +* Downlink Payload (prefix 0xAA 02):
848 848  
849 -**0xAA 02 aa bb        **~/~/ Same as AT+DTRI=aa,bb
888 +(% class="box infomessage" %)
889 +(((
890 +**0xAA 02 aa bb  ~/~/ Same as AT+DTRI=aa,bb**
891 +)))
850 850  
851 851  
852 852  
853 -
854 854  ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ====
855 855  
856 856  Set DI1 or DI3(for LT-33222-L) trigger.
857 857  
858 -* (% style="color:#037691" %)AT Command:
899 +* AT Command:
859 859  
901 +(% class="box infomessage" %)
902 +(((
860 860  **AT+TRIG1=a,b**
904 +)))
861 861  
862 862  a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1).
863 863  
... ... @@ -869,20 +869,26 @@
869 869  AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms )
870 870  
871 871  
872 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):**
873 -* **0x09 01 aa bb cc    ** ~/~/ same as AT+TRIG1=aa,0x(bb cc)
916 +* Downlink Payload (prefix 0x09 01 ):
874 874  
918 +(% class="box infomessage" %)
919 +(((
920 +**0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)**
921 +)))
875 875  
876 876  
924 +
877 877  ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
878 878  
879 879  Set DI2 trigger.
880 880  
881 -* (% style="color:#037691" %)**AT Command:**
929 +* AT Command:
882 882  
931 +(% class="box infomessage" %)
932 +(((
883 883  **AT+TRIG2=a,b**
934 +)))
884 884  
885 -
886 886  a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1).
887 887  
888 888  b : delay timing.
... ... @@ -893,72 +893,93 @@
893 893  AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms )
894 894  
895 895  
896 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):**
946 +* Downlink Payload (prefix 0x09 02 ):
897 897  
898 -**0x09 02 aa bb cc           **~/~/ same as AT+TRIG1=aa,0x(bb cc)
948 +(% class="box infomessage" %)
949 +(((
950 +**0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)**
951 +)))
899 899  
900 900  
901 901  
902 -
903 903  ==== 3.4.2.9 Trigger – Set AC (current) as trigger ====
904 904  
905 905  Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
906 906  
907 -* (% style="color:#037691" %)**AT Command**
959 +* AT Command:
908 908  
909 -**AT+ACLIM**
961 +(% class="box infomessage" %)
962 +(((
963 +**AT+ACLIM. **
964 +)))
910 910  
911 911  
912 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )**
967 +* Downlink Payload (prefix 0xAA 01 ):
913 913  
914 -**0x AA 01 aa bb cc dd ee ff gg hh        ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
969 +(% class="box infomessage" %)
970 +(((
971 +**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
972 +)))
915 915  
916 916  
917 917  
918 -
919 919  ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ====
920 920  
921 921  Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
922 922  
923 -* (% style="color:#037691" %)**AT Command**
980 +* AT Command:
924 924  
925 -**AT+AVLIM  See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
982 +(% class="box infomessage" %)
983 +(((
984 +**AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
985 +)))
926 926  
927 927  
928 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )**
988 +* Downlink Payload (prefix 0xAA 00 ):
929 929  
930 -**0x AA 00 aa bb cc dd ee ff gg hh    ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
990 +(% class="box infomessage" %)
991 +(((
992 +**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] **
993 +)))
931 931  
932 932  
933 933  
934 -
935 935  ==== 3.4.2.11 Trigger – Set minimum interval ====
936 936  
937 937  Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger.
938 938  
939 -* (% style="color:#037691" %)**AT Command**
1001 +* AT Command:
940 940  
1003 +(% class="box infomessage" %)
1004 +(((
941 941  **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.**
1006 +)))
942 942  
943 943  
944 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )**
1009 +* Downlink Payload (prefix 0xAC ):
945 945  
946 -**0x AC aa bb   ** ~/~/ same as AT+ATDC=0x(aa bb)   . Unit (min)
1011 +(% class="box infomessage" %)
1012 +(((
1013 +**0x AC aa bb ~/~/ same as AT+ATDC=0x(aa bb)   . Unit (min)**
1014 +)))
947 947  
948 948  
949 949  
950 -
951 951  ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ====
952 952  
953 -* (% style="color:#037691" %)**AT Command**
1020 +* AT Command:
954 954  
955 955  There is no AT Command to control Digital Output
956 956  
957 957  
958 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x02)**
959 -* **0x02 aa bb cc     **~/~/ Set DO1/DO2/DO3 output
1025 +* Downlink Payload (prefix 0x02):
960 960  
1027 +(% class="box infomessage" %)
961 961  (((
1029 +**0x02 aa bb cc     ~/~/ Set DO1/DO2/DO3 output**
1030 +)))
1031 +
1032 +(((
962 962  If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low.
963 963  )))
964 964  
... ... @@ -978,19 +978,22 @@
978 978  
979 979  
980 980  
981 -
982 982  ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ====
983 983  
984 -* (% style="color:#037691" %)**AT Command**
1054 +* AT Command:
985 985  
986 986  There is no AT Command to control Digital Output
987 987  
988 988  
989 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA9)**
1059 +* Downlink Payload (prefix 0xA9):
990 990  
991 -**0xA9 aa bb cc     **~/~/ Set DO1/DO2/DO3 output with time control
1061 +(% class="box infomessage" %)
1062 +(((
1063 +(((
1064 +**0xA9 aa bb cc     ~/~/ Set DO1/DO2/DO3 output with time control**
1065 +)))
1066 +)))
992 992  
993 -
994 994  This is to control the digital output time of DO pin. Include four bytes:
995 995  
996 996  (% style="color:#4f81bd" %)**First Byte**(%%)**:** Type code (0xA9)
... ... @@ -1044,19 +1044,20 @@
1044 1044  
1045 1045  
1046 1046  
1047 -
1048 1048  ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1049 1049  
1050 -* (% style="color:#037691" %)**AT Command:**
1123 +* AT Command:
1051 1051  
1052 1052  There is no AT Command to control Relay Output
1053 1053  
1054 1054  
1055 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x03):**
1128 +* Downlink Payload (prefix 0x03):
1056 1056  
1057 -**0x03 aa bb     **~/~/ Set RO1/RO2 output
1130 +(% class="box infomessage" %)
1131 +(((
1132 +**0x03 aa bb     ~/~/ Set RO1/RO2 output**
1133 +)))
1058 1058  
1059 -
1060 1060  (((
1061 1061  If payload = 0x030100, it means set RO1 to close and RO2 to open.
1062 1062  )))
... ... @@ -1073,19 +1073,20 @@
1073 1073  
1074 1074  
1075 1075  
1076 -
1077 1077  ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ====
1078 1078  
1079 -* (% style="color:#037691" %)**AT Command:**
1153 +* AT Command:
1080 1080  
1081 1081  There is no AT Command to control Relay Output
1082 1082  
1083 1083  
1084 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x05):**
1158 +* Downlink Payload (prefix 0x05):
1085 1085  
1086 -**0x05 aa bb cc dd     **~/~/ Set RO1/RO2 relay with time control
1160 +(% class="box infomessage" %)
1161 +(((
1162 +**0x05 aa bb cc dd     ~/~/ Set RO1/RO2 relay with time control:**
1163 +)))
1087 1087  
1088 -
1089 1089  This is to control the relay output time of relay. Include four bytes:
1090 1090  
1091 1091  (% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05)
... ... @@ -1127,28 +1127,35 @@
1127 1127  
1128 1128  
1129 1129  
1130 -
1131 1131  ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ====
1132 1132  
1133 1133  When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1134 1134  
1135 -* (% style="color:#037691" %)**AT Command:**
1210 +* AT Command:
1136 1136  
1137 -**AT+VOLMAX   ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1212 +(% class="box infomessage" %)
1213 +(((
1214 +**AT+VOLMAX    ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]**
1215 +)))
1138 1138  
1139 1139  
1140 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):**
1218 +* Downlink Payload (prefix 0xA5):
1141 1141  
1142 -**0xA5 aa bb cc   **~/~/ Same as AT+VOLMAX=(aa bb),cc
1220 +(% class="box infomessage" %)
1221 +(((
1222 +**0xA5 aa bb cc   ~/~/ Same as AT+VOLMAX=(aa bb),cc**
1223 +)))
1143 1143  
1144 1144  
1145 1145  
1146 -
1147 1147  ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ====
1148 1148  
1149 -* (% style="color:#037691" %)**AT Command:**
1229 +* AT Command:
1150 1150  
1151 -(% style="color:#037691" %)**​​​​​​​​​​​​​​**(%%)**AT+SETCNT=aa,(bb cc dd ee) **
1231 +(% class="box infomessage" %)
1232 +(((
1233 +**AT+SETCNT=aa,(bb cc dd ee) **
1234 +)))
1152 1152  
1153 1153  aa: 1: Set count1,
1154 1154  
... ... @@ -1159,40 +1159,51 @@
1159 1159  Bb cc dd ee: number to be set
1160 1160  
1161 1161  
1162 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA8):**
1245 +* Downlink Payload (prefix 0xA8):
1163 1163  
1164 -**0x A8 aa bb cc dd ee     **~/~/ same as AT+SETCNT=aa,(bb cc dd ee)
1247 +(% class="box infomessage" %)
1248 +(((
1249 +**0x A8 aa bb cc dd ee     ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)**
1250 +)))
1165 1165  
1166 1166  
1167 1167  
1168 -
1169 1169  ==== 3.4.2.18 Counting ~-~- Clear Counting ====
1170 1170  
1171 1171  Clear counting for counting mode
1172 1172  
1173 -* (% style="color:#037691" %)**AT Command:**
1258 +* AT Command:
1174 1174  
1175 -(% style="color:#037691" %)​​​​​​​​​​​​​​(%%)**AT+CLRCOUNT ** ~/~/ clear all counting
1260 +(% class="box infomessage" %)
1261 +(((
1262 +**AT+CLRCOUNT ~/~/ clear all counting**
1263 +)))
1176 1176  
1265 +* Downlink Payload (prefix 0xA6):
1177 1177  
1178 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):**
1267 +(% class="box infomessage" %)
1268 +(((
1269 +**0x A6 01     ~/~/ clear all counting,**
1270 +)))
1179 1179  
1180 -**0x A6 01    ** ~/~/ clear all counting
1181 1181  
1182 1182  
1183 -
1184 -
1185 1185  ==== 3.4.2.19 Counting ~-~- Change counting mode save time ====
1186 1186  
1187 -* (% style="color:#037691" %)**AT Command:**
1276 +* AT Command:
1188 1188  
1189 -**AT+COUTIME=60  **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)
1278 +(% class="box infomessage" %)
1279 +(((
1280 +**AT+COUTIME=60  ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)**
1281 +)))
1190 1190  
1283 +* Downlink Payload (prefix 0xA7):
1191 1191  
1192 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA7):**
1285 +(% class="box infomessage" %)
1286 +(((
1287 +**0x A7 aa bb cc     ~/~/ same as AT+COUTIME =aa bb cc,**
1288 +)))
1193 1193  
1194 -**0x A7 aa bb cc     **~/~/ same as AT+COUTIME =aa bb cc,
1195 -
1196 1196  (((
1197 1197  range: aa bb cc:0 to 16777215,  (unit:second)
1198 1198  
... ... @@ -1200,7 +1200,6 @@
1200 1200  )))
1201 1201  
1202 1202  
1203 -
1204 1204  == 3.5 Integrate with Mydevice ==
1205 1205  
1206 1206  Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps:
... ... @@ -1890,16 +1890,8 @@
1890 1890  )))
1891 1891  
1892 1892  (((
1893 -== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? ==
1986 +
1894 1894  
1895 -If the device is not shut down, but directly powered off.
1896 -
1897 -It will default that this is a power-off state.
1898 -
1899 -In modes 2 to 5, DO RO status and pulse count are saved in flash.
1900 -
1901 -After restart, the status before power failure will be read from flash.
1902 -
1903 1903  = 6. Trouble Shooting =
1904 1904  )))
1905 1905