Last modified by Mengting Qiu on 2025/06/04 18:42

From version 82.24
edited by Xiaoling
on 2022/06/20 11:59
Change comment: There is no comment for this version
To version 82.27
edited by Xiaoling
on 2022/06/20 12:01
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -181,7 +181,6 @@
181 181  * Firmware upgradable via program port
182 182  * Counting
183 183  
184 -
185 185  == 1.4  Applications ==
186 186  
187 187  * Smart Buildings & Home Automation
... ... @@ -191,7 +191,6 @@
191 191  * Smart Cities
192 192  * Smart Factory
193 193  
194 -
195 195  == 1.5 Hardware Variants ==
196 196  
197 197  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -207,7 +207,6 @@
207 207  
208 208  
209 209  
210 -
211 211  = 2. Power ON Device =
212 212  
213 213  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -288,7 +288,6 @@
288 288  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
289 289  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
290 290  
291 -
292 292  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
293 293  
294 294  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -342,7 +342,6 @@
342 342  ** DO1 is high in case there is load between DO1 and V+.
343 343  ** DO1 LED is off in both case
344 344  
345 -
346 346  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
347 347  
348 348  
... ... @@ -392,24 +392,20 @@
392 392  
393 393  (((
394 394  **For LT22222-L:**
395 -)))
396 396  
397 -(% class="box infomessage" %)
398 -(((
399 -(((
400 -**AT+TRIG1=0,100  (set DI1 port to trigger on low level, valid signal is 100ms) **
401 401  
402 -**AT+TRIG1=1,100  (set DI1 port to trigger on high level, valid signal is 100ms ) **
392 +(% style="color:blue" %)**AT+TRIG1=0,100**(%%)**  (set DI1 port to trigger on low level, valid signal is 100ms) **
403 403  
404 -**AT+TRIG2=0,100  (set DI2 port to trigger on low level, valid signal is 100ms) **
394 +(% style="color:blue" %)**AT+TRIG1=1,100**(%%)**  (set DI1 port to trigger on high level, valid signal is 100ms ) **
405 405  
406 -**AT+TRIG2=1,100  (set DI2 port to trigger on high level, valid signal is 100ms ) **
396 +(% style="color:blue" %)**AT+TRIG2=0,100**(%%)**  (set DI2 port to trigger on low level, valid signal is 100ms) **
407 407  
408 -**AT+SETCNT=1,6  (Set COUNT1 value to 60)**
398 +(% style="color:blue" %)**AT+TRIG2=1,100**(%%)**  (set DI2 port to trigger on high level, valid signal is 100ms ) **
409 409  
410 -**AT+SETCNT=2,60   (Set COUNT2 value to 60)**
400 +(% style="color:blue" %)**AT+SETCNT=1,60**(%%)**   (Set COUNT1 value to 60)**
401 +
402 +(% style="color:blue" %)**AT+SETCNT=2,60**(%%)**   (Set COUNT2 value to 60)**
411 411  )))
412 -)))
413 413  
414 414  
415 415  
... ... @@ -501,11 +501,8 @@
501 501  
502 502  
503 503  **Plus below command for AVI1 Counting:**
504 -)))
505 505  
506 -(% class="box infomessage" %)
507 -(((
508 -(((
496 +
509 509  (% style="color:blue" %)**AT+SETCNT=3,60**(%%)**  (set AVI Count to 60)**
510 510  
511 511  (% style="color:blue" %)**AT+VOLMAX=20000**(%%)**  (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)**
... ... @@ -514,9 +514,9 @@
514 514  
515 515  (% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)**  (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)**
516 516  )))
517 -)))
518 518  
519 519  
507 +
520 520  === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI ===
521 521  
522 522  
... ... @@ -576,7 +576,6 @@
576 576  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
577 577  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
578 578  
579 -
580 580  (% style="color:#037691" %)**AT Command to set Trigger Condition**:
581 581  
582 582  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -718,7 +718,6 @@
718 718  
719 719  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
720 720  
721 -
722 722  === 3.4.1 Common Commands ===
723 723  
724 724  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -876,7 +876,6 @@
876 876  * **0x09 01 aa bb cc    ** ~/~/ same as AT+TRIG1=aa,0x(bb cc)
877 877  
878 878  
879 -
880 880  ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
881 881  
882 882  Set DI2 trigger.
... ... @@ -1137,7 +1137,7 @@
1137 1137  
1138 1138  * (% style="color:#037691" %)**AT Command:**
1139 1139  
1140 -(% style="color:#037691" %)**​​​​​​​**(%%)**AT+VOLMAX   ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1125 +**AT+VOLMAX   ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1141 1141  
1142 1142  
1143 1143  * (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):**
... ... @@ -1151,7 +1151,7 @@
1151 1151  
1152 1152  * (% style="color:#037691" %)**AT Command:**
1153 1153  
1154 -(% style="color:#037691" %)**​​​​​​​​​​​​​​**(%%)**AT+SETCNT=aa,(bb cc dd ee) **
1139 +(% style="color:#037691" %)**​​​​​​​**(%%)**AT+SETCNT=aa,(bb cc dd ee) **
1155 1155  
1156 1156  aa: 1: Set count1,
1157 1157