Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -182,6 +182,7 @@ 182 182 * Counting 183 183 184 184 185 + 185 185 == 1.4 Applications == 186 186 187 187 * Smart Buildings & Home Automation ... ... @@ -192,6 +192,7 @@ 192 192 * Smart Factory 193 193 194 194 196 + 195 195 == 1.5 Hardware Variants == 196 196 197 197 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -206,8 +206,6 @@ 206 206 ))) 207 207 208 208 209 - 210 - 211 211 = 2. Power ON Device = 212 212 213 213 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -289,6 +289,7 @@ 289 289 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 290 290 291 291 292 + 292 292 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 293 293 294 294 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -343,6 +343,7 @@ 343 343 ** DO1 LED is off in both case 344 344 345 345 347 + 346 346 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 347 347 348 348 ... ... @@ -397,13 +397,13 @@ 397 397 (% class="box infomessage" %) 398 398 ((( 399 399 ((( 400 -**AT+TRIG1=0,100 402 +**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 401 401 402 -**AT+TRIG1=1,100 404 +**AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 403 403 404 -**AT+TRIG2=0,100 406 +**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 405 405 406 -**AT+TRIG2=1,100 408 +**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 407 407 408 408 **AT+SETCNT=1,60 (Set COUNT1 value to 60)** 409 409 ... ... @@ -506,13 +506,13 @@ 506 506 (% class="box infomessage" %) 507 507 ((( 508 508 ((( 509 -(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** 511 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 510 510 511 -(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** 513 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 512 512 513 -(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** 515 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 514 514 515 -(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** 517 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 516 516 ))) 517 517 ))) 518 518 ... ... @@ -718,6 +718,7 @@ 718 718 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 719 719 720 720 723 + 721 721 === 3.4.1 Common Commands === 722 722 723 723 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -839,7 +839,10 @@ 839 839 840 840 * (% style="color:#037691" %)AT Command: 841 841 845 +(% class="box infomessage" %) 846 +((( 842 842 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 848 +))) 843 843 844 844 845 845 **Example:** ... ... @@ -848,11 +848,13 @@ 848 848 849 849 * (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 850 850 851 -**0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 857 +(% class="box infomessage" %) 858 +((( 859 +**0xAA 02 aa bb ~/~/ Same as AT+DTRI=aa,bb** 860 +))) 852 852 853 853 854 854 855 - 856 856 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 857 857 858 858 Set DI1 or DI3(for LT-33222-L) trigger. ... ... @@ -859,7 +859,10 @@ 859 859 860 860 * (% style="color:#037691" %)AT Command: 861 861 870 +(% class="box infomessage" %) 871 +((( 862 862 **AT+TRIG1=a,b** 873 +))) 863 863 864 864 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 865 865 ... ... @@ -871,20 +871,26 @@ 871 871 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 872 872 873 873 874 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 875 -* **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 885 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 01 ): 876 876 887 +(% class="box infomessage" %) 888 +((( 889 +**0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 890 +))) 877 877 878 878 893 + 879 879 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 880 880 881 881 Set DI2 trigger. 882 882 883 -* (% style="color:#037691" %) **AT Command:**898 +* (% style="color:#037691" %)AT Command: 884 884 900 +(% class="box infomessage" %) 901 +((( 885 885 **AT+TRIG2=a,b** 903 +))) 886 886 887 - 888 888 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 889 889 890 890 b : delay timing. ... ... @@ -895,72 +895,93 @@ 895 895 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 896 896 897 897 898 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x09 02 ):**915 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 02 ): 899 899 900 -**0x09 02 aa bb cc **~/~/ same as AT+TRIG1=aa,0x(bb cc) 917 +(% class="box infomessage" %) 918 +((( 919 +**0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 920 +))) 901 901 902 902 903 903 904 - 905 905 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 906 906 907 907 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 908 908 909 -* (% style="color:#037691" %) **AT Command**928 +* (% style="color:#037691" %)AT Command: 910 910 911 -**AT+ACLIM** 930 +(% class="box infomessage" %) 931 +((( 932 +**AT+ACLIM. ** 933 +))) 912 912 913 913 914 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAA 01 )**936 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 01 ): 915 915 916 -**0x AA 01 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 938 +(% class="box infomessage" %) 939 +((( 940 +**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 941 +))) 917 917 918 918 919 919 920 - 921 921 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 922 922 923 923 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 924 924 925 -* (% style="color:#037691" %) **AT Command**949 +* (% style="color:#037691" %)AT Command: 926 926 927 -**AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 951 +(% class="box infomessage" %) 952 +((( 953 +**AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 954 +))) 928 928 929 929 930 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAA 00 )**957 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 00 ): 931 931 932 -**0x AA 00 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 959 +(% class="box infomessage" %) 960 +((( 961 +**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ** 962 +))) 933 933 934 934 935 935 936 - 937 937 ==== 3.4.2.11 Trigger – Set minimum interval ==== 938 938 939 939 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 940 940 941 -* (% style="color:#037691" %) **AT Command**970 +* (% style="color:#037691" %)AT Command: 942 942 972 +(% class="box infomessage" %) 973 +((( 943 943 **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.** 975 +))) 944 944 945 945 946 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAC )**978 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAC ): 947 947 948 -**0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 980 +(% class="box infomessage" %) 981 +((( 982 +**0x AC aa bb ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min)** 983 +))) 949 949 950 950 951 951 952 - 953 953 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 954 954 955 -* (% style="color:#037691" %) **AT Command**989 +* (% style="color:#037691" %)AT Command: 956 956 957 957 There is no AT Command to control Digital Output 958 958 959 959 960 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x02)** 961 -* **0x02 aa bb cc **~/~/ Set DO1/DO2/DO3 output 994 +* (% style="color:#037691" %)Downlink Payload (prefix 0x02): 962 962 996 +(% class="box infomessage" %) 963 963 ((( 998 +**0x02 aa bb cc ~/~/ Set DO1/DO2/DO3 output** 999 +))) 1000 + 1001 +((( 964 964 If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low. 965 965 ))) 966 966 ... ... @@ -980,19 +980,22 @@ 980 980 981 981 982 982 983 - 984 984 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 985 985 986 -* (% style="color:#037691" %) **AT Command**1023 +* (% style="color:#037691" %)AT Command: 987 987 988 988 There is no AT Command to control Digital Output 989 989 990 990 991 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xA9)**1028 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA9): 992 992 993 -**0xA9 aa bb cc **~/~/ Set DO1/DO2/DO3 output with time control 1030 +(% class="box infomessage" %) 1031 +((( 1032 +((( 1033 +**0xA9 aa bb cc ~/~/ Set DO1/DO2/DO3 output with time control** 1034 +))) 1035 +))) 994 994 995 - 996 996 This is to control the digital output time of DO pin. Include four bytes: 997 997 998 998 (% style="color:#4f81bd" %)**First Byte**(%%)**:** Type code (0xA9) ... ... @@ -1046,19 +1046,20 @@ 1046 1046 1047 1047 1048 1048 1049 - 1050 1050 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1051 1051 1052 -* (% style="color:#037691" %) **AT Command:**1092 +* (% style="color:#037691" %)AT Command: 1053 1053 1054 1054 There is no AT Command to control Relay Output 1055 1055 1056 1056 1057 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x03):**1097 +* (% style="color:#037691" %)Downlink Payload (prefix 0x03): 1058 1058 1059 -**0x03 aa bb **~/~/ Set RO1/RO2 output 1099 +(% class="box infomessage" %) 1100 +((( 1101 +**0x03 aa bb ~/~/ Set RO1/RO2 output** 1102 +))) 1060 1060 1061 - 1062 1062 ((( 1063 1063 If payload = 0x030100, it means set RO1 to close and RO2 to open. 1064 1064 ))) ... ... @@ -1075,10 +1075,9 @@ 1075 1075 1076 1076 1077 1077 1078 - 1079 1079 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1080 1080 1081 -* (% style="color:#037691" %) **AT Command:**1122 +* (% style="color:#037691" %)AT Command: 1082 1082 1083 1083 There is no AT Command to control Relay Output 1084 1084