Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -1,7 +1,6 @@ 1 1 (% style="text-align:center" %) 2 2 [[image:image-20220523163353-1.jpeg||height="604" width="500"]] 3 3 4 -**LT-22222-L LoRa IO Controller User Manual ** 5 5 6 6 7 7 **Table of Contents:** ... ... @@ -167,7 +167,6 @@ 167 167 Packet engine up to 256 bytes with CRC. 168 168 169 169 170 - 171 171 172 172 ))) 173 173 ... ... @@ -181,7 +181,6 @@ 181 181 * Firmware upgradable via program port 182 182 * Counting 183 183 184 - 185 185 == 1.4 Applications == 186 186 187 187 * Smart Buildings & Home Automation ... ... @@ -191,7 +191,6 @@ 191 191 * Smart Cities 192 192 * Smart Factory 193 193 194 - 195 195 == 1.5 Hardware Variants == 196 196 197 197 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -205,9 +205,6 @@ 205 205 * 1 x Counting Port 206 206 ))) 207 207 208 - 209 - 210 - 211 211 = 2. Power ON Device = 212 212 213 213 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -225,11 +225,11 @@ 225 225 == 3.1 How it works? == 226 226 227 227 ((( 228 -The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on **TX LED** will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. **TX LED** will be on for 5 seconds after joined in network. When there is message from server, the **RX LED**will be on for 1 second.221 +The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%) will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. (% style="color:green" %)**TX LED**(%%) will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second. 229 229 ))) 230 230 231 231 ((( 232 -In case user can ’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.225 +In case user can't set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 233 233 ))) 234 234 235 235 ... ... @@ -281,14 +281,13 @@ 281 281 282 282 There are five working modes + one interrupt mode on LT for different type application: 283 283 284 -* **MOD1**: (default setting): 2 x ACI + 2AVI + DI + DO + RO 285 -* **MOD2**: Double DI Counting + DO + RO 286 -* **MOD3**: Single DI Counting + 2 x ACI + DO + RO 287 -* **MOD4**: Single DI Counting + 1 x Voltage Counting + DO + RO 288 -* **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 289 -* **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 277 +* (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO 278 +* (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO 279 +* (% style="color:blue" %)**MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO 280 +* (% style="color:blue" %)**MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO 281 +* (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 282 +* (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5 290 290 291 - 292 292 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 293 293 294 294 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -342,7 +342,6 @@ 342 342 ** DO1 is high in case there is load between DO1 and V+. 343 343 ** DO1 LED is off in both case 344 344 345 - 346 346 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 347 347 348 348 ... ... @@ -392,24 +392,20 @@ 392 392 393 393 ((( 394 394 **For LT22222-L:** 395 -))) 396 396 397 -(% class="box infomessage" %) 398 -((( 399 -((( 400 -**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 401 401 402 -**AT+TRIG1= 1,100(set DI1 port to trigger onhighlevel, valid signal is 100ms388 +(% style="color:blue" %)**AT+TRIG1=0,100**(%%)** (set DI1 port to trigger on low level, valid signal is 100ms) ** 403 403 404 -**AT+TRIG 2=0,100 (set DI2port to trigger onlowlevel, valid signal is 100ms) **390 +(% style="color:blue" %)**AT+TRIG1=1,100**(%%)** (set DI1 port to trigger on high level, valid signal is 100ms ) ** 405 405 406 -**AT+TRIG2= 1,100 (set DI2 port to trigger onhighlevel, valid signal is 100ms392 +(% style="color:blue" %)**AT+TRIG2=0,100**(%%)** (set DI2 port to trigger on low level, valid signal is 100ms) ** 407 407 408 -**AT+ SETCNT=1,60SetCOUNT1valueto60)**394 +(% style="color:blue" %)**AT+TRIG2=1,100**(%%)** (set DI2 port to trigger on high level, valid signal is 100ms ) ** 409 409 410 -**AT+SETCNT=2,60 (Set COUNT2 value to 60)** 396 +(% style="color:blue" %)**AT+SETCNT=1,60**(%%)** (Set COUNT1 value to 60)** 397 + 398 +(% style="color:blue" %)**AT+SETCNT=2,60**(%%)** (Set COUNT2 value to 60)** 411 411 ))) 412 -))) 413 413 414 414 415 415 ... ... @@ -420,6 +420,8 @@ 420 420 [[image:image-20220523181246-5.png]] 421 421 422 422 ((( 410 + 411 + 423 423 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 424 424 ))) 425 425 ... ... @@ -433,6 +433,7 @@ 433 433 (% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 434 434 ))) 435 435 425 + 436 436 ((( 437 437 **To use counting mode, please run:** 438 438 ))) ... ... @@ -501,22 +501,19 @@ 501 501 502 502 503 503 **Plus below command for AVI1 Counting:** 504 -))) 505 505 506 -(% class="box infomessage" %) 507 -((( 508 -((( 509 -(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 510 510 511 -(% style="color:blue" %)**AT+ VOLMAX=20000**(%%)**(IfAVI1voltagehigherthanVOLMAX(20000mV=20v), counterincrease1)**496 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 512 512 513 -(% style="color:blue" %)**AT+VOLMAX=20000 ,0**(%%)**lower than VOLMAX (20000mV =20v), counter increase 1)**498 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 514 514 515 -(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 500 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 501 + 502 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 516 516 ))) 517 -))) 518 518 519 519 506 + 520 520 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 521 521 522 522 ... ... @@ -568,8 +568,8 @@ 568 568 569 569 For example, if user has configured below commands: 570 570 571 -* **AT+MOD=1 ** **~-~->** The normal working mode 572 -* **AT+ADDMOD6=1** **~-~->** Enable trigger 558 +* **AT+MOD=1 ** **~-~->** The normal working mode 559 +* **AT+ADDMOD6=1** **~-~->** Enable trigger 573 573 574 574 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 575 575 ... ... @@ -578,6 +578,7 @@ 578 578 579 579 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 580 580 568 + 581 581 (% style="color:#4f81bd" %)**Trigger base on voltage**: 582 582 583 583 Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH> ... ... @@ -717,7 +717,6 @@ 717 717 718 718 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 719 719 720 - 721 721 === 3.4.1 Common Commands === 722 722 723 723 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -726,6 +726,7 @@ 726 726 727 727 === 3.4.2 Sensor related commands === 728 728 716 + 729 729 ==== 3.4.2.1 Set Transmit Interval ==== 730 730 731 731 Set device uplink interval. ... ... @@ -732,23 +732,19 @@ 732 732 733 733 * (% style="color:#037691" %)**AT Command:** 734 734 735 -(% class="box infomessage" %) 736 -((( 737 737 **AT+TDC=N ** 738 -))) 739 739 725 + 740 740 **Example: **AT+TDC=30000. Means set interval to 30 seconds 741 741 742 742 743 743 * (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 744 744 745 -(% class="box infomessage" %) 746 -((( 747 747 **0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 748 -))) 749 749 750 750 751 751 735 + 752 752 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 753 753 754 754 Set work mode. ... ... @@ -755,51 +755,42 @@ 755 755 756 756 * (% style="color:#037691" %)**AT Command:** 757 757 758 -(% class="box infomessage" %) 759 -((( 760 760 **AT+MOD=N ** 761 -))) 762 762 744 + 763 763 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 764 764 765 765 766 766 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 767 767 768 -(% class="box infomessage" %) 769 -((( 770 -**0x0A aa ~/~/ Same as AT+MOD=aa** 771 -))) 750 +**0x0A aa ** ~/~/ Same as AT+MOD=aa 772 772 773 773 774 774 754 + 775 775 ==== 3.4.2.3 Poll an uplink ==== 776 776 777 -* (% style="color:#037691" %)AT Command: 757 +* (% style="color:#037691" %)**AT Command:** 778 778 779 779 There is no AT Command to poll uplink 780 780 781 781 782 -* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 762 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x08):** 783 783 784 -(% class="box infomessage" %) 785 -((( 786 -**0x08 FF ~/~/ Poll an uplink,** 787 -))) 764 +**0x08 FF **~/~/ Poll an uplink 788 788 789 789 **Example**: 0x08FF, ask device to send an Uplink 790 790 791 791 792 792 770 + 793 793 ==== 3.4.2.4 Enable Trigger Mode ==== 794 794 795 795 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 796 796 797 -* (% style="color:#037691" %)AT Command: 775 +* (% style="color:#037691" %)**AT Command:** 798 798 799 -(% class="box infomessage" %) 800 -((( 801 801 **AT+ADDMOD6=1 or 0** 802 -))) 803 803 804 804 1: Enable Trigger Mode 805 805 ... ... @@ -806,38 +806,34 @@ 806 806 0: Disable Trigger Mode 807 807 808 808 809 -* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 784 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):** 810 810 811 -(% class="box infomessage" %) 812 -((( 813 -**0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 814 -))) 786 +**0x0A 06 aa ** ~/~/ Same as AT+ADDMOD6=aa 815 815 816 816 817 817 790 + 818 818 ==== 3.4.2.5 Poll trigger settings ==== 819 819 820 820 Poll trigger settings, 821 821 822 -* (% style="color:#037691" %)AT Command: 795 +* (% style="color:#037691" %)**AT Command:** 823 823 824 824 There is no AT Command for this feature. 825 825 826 826 827 -* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 800 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):** 828 828 829 -(% class="box infomessage" %) 830 -((( 831 -**0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 832 -))) 802 +**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 833 833 834 834 835 835 806 + 836 836 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 837 837 838 838 Enable Disable DI1/DI2/DI2 as trigger, 839 839 840 -* (% style="color:#037691" %)AT Command: 811 +* (% style="color:#037691" %)**AT Command:** 841 841 842 842 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 843 843 ... ... @@ -846,7 +846,7 @@ 846 846 847 847 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 848 848 849 -* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 820 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):** 850 850 851 851 **0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 852 852 ... ... @@ -857,7 +857,7 @@ 857 857 858 858 Set DI1 or DI3(for LT-33222-L) trigger. 859 859 860 -* (% style="color:#037691" %)AT Command: 831 +* (% style="color:#037691" %)**AT Command:** 861 861 862 862 **AT+TRIG1=a,b** 863 863 ... ... @@ -874,8 +874,6 @@ 874 874 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 875 875 * **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 876 876 877 - 878 - 879 879 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 880 880 881 881 Set DI2 trigger. ... ... @@ -936,11 +936,11 @@ 936 936 937 937 ==== 3.4.2.11 Trigger – Set minimum interval ==== 938 938 939 -Set AV and AC trigger minimum interval, system won ’t response to the second trigger within this set time after the first trigger.908 +Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger. 940 940 941 941 * (% style="color:#037691" %)**AT Command** 942 942 943 -**AT+ATDC=5 .Device won’t response the second trigger within 5 minute after the first trigger.**912 +**AT+ATDC=5 ** Device won't response the second trigger within 5 minute after the first trigger. 944 944 945 945 946 946 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** ... ... @@ -947,9 +947,15 @@ 947 947 948 948 **0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 949 949 919 +((( 920 + 950 950 922 +(% style="color:red" %)Note: ATDC setting must be more than 5min 923 +))) 951 951 952 952 926 + 927 + 953 953 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 954 954 955 955 * (% style="color:#037691" %)**AT Command** ... ... @@ -1101,7 +1101,7 @@ 1101 1101 1102 1102 (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status: 1103 1103 1104 -[[image:image-20220 524093831-10.png]]1079 +[[image:image-20220714135731-1.png||height="406" width="627"]] 1105 1105 1106 1106 1107 1107 (% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms ... ... @@ -1111,21 +1111,21 @@ 1111 1111 1112 1112 **Example payload:** 1113 1113 1114 -**~1. 05 01 11 07 D 0**1089 +**~1. 05 01 11 07 D** 1115 1115 1116 -Relay1 and Relay 2 will be set to N O, last 2 seconds, then change back to original state.1091 +Relay1 and Relay 2 will be set to NC , last 2 seconds, then change back to original state. 1117 1117 1118 1118 **2. 05 01 10 07 D0** 1119 1119 1120 -Relay1 will change to N O, Relay2 will change to NC, last 2 seconds, then both change back to original state.1095 +Relay1 will change to NC, Relay2 will change to NO, last 2 seconds, then both change back to original state. 1121 1121 1122 1122 **3. 05 00 01 07 D0** 1123 1123 1124 -Relay1 will change to N C, Relay2 will change to NO, last 2 seconds, then relay change to NO,C.1099 +Relay1 will change to NO, Relay2 will change to NC, last 2 seconds, then relay change to NC,Relay2 change to NO. 1125 1125 1126 1126 **4. 05 00 00 07 D0** 1127 1127 1128 -Relay 1 & relay2 will change to N C, last 2 seconds, then both change to NO.1103 +Relay 1 & relay2 will change to NO, last 2 seconds, then both change to NC. 1129 1129 1130 1130 1131 1131 ... ... @@ -1136,7 +1136,7 @@ 1136 1136 1137 1137 * (% style="color:#037691" %)**AT Command:** 1138 1138 1139 - (% style="color:#037691" %)****(%%)**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]1114 +**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1140 1140 1141 1141 1142 1142 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** ... ... @@ -1150,7 +1150,7 @@ 1150 1150 1151 1151 * (% style="color:#037691" %)**AT Command:** 1152 1152 1153 - (% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) **1128 +**AT+SETCNT=aa,(bb cc dd ee) ** 1154 1154 1155 1155 aa: 1: Set count1, 1156 1156 ... ... @@ -1174,7 +1174,7 @@ 1174 1174 1175 1175 * (% style="color:#037691" %)**AT Command:** 1176 1176 1177 - (% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting1152 +**AT+CLRCOUNT ** ~/~/ clear all counting 1178 1178 1179 1179 1180 1180 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** ... ... @@ -1215,12 +1215,11 @@ 1215 1215 (% style="color:blue" %)**Step 2**(%%): To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps: 1216 1216 ))) 1217 1217 1218 -[[image:1 653356737703-362.png||height="232" width="732"]]1193 +[[image:image-20220719105525-1.png||height="452" width="814"]] 1219 1219 1220 -[[image:image-20220524094641-11.png||height="390" width="723"]] 1221 1221 1222 1222 1223 -[[image:image-20220 524094641-12.png||height="402" width="718"]]1197 +[[image:image-20220719110247-2.png||height="457" width="804"]] 1224 1224 1225 1225 1226 1226 (% style="color:blue" %)**Step 3**(%%): Create an account or log in Mydevices. ... ... @@ -1432,6 +1432,7 @@ 1432 1432 [[image:image-20220524100748-11.png]] 1433 1433 1434 1434 1409 + 1435 1435 = 4. Use AT Command = 1436 1436 1437 1437 == 4.1 Access AT Command == ... ... @@ -1634,8 +1634,6 @@ 1634 1634 1635 1635 ((( 1636 1636 AT+CFG: Print all settings 1637 - 1638 - 1639 1639 ))) 1640 1640 1641 1641 ... ... @@ -1681,8 +1681,6 @@ 1681 1681 1682 1682 ((( 1683 1683 (% style="background-color:#dcdcdc" %)ATZ 1684 - 1685 - 1686 1686 ))) 1687 1687 1688 1688 ... ... @@ -1795,7 +1795,7 @@ 1795 1795 1796 1796 1797 1797 (% style="color:blue" %)**For LT-22222-L**(%%): 1798 -Hold down the PRO button and then momentarily press the RST reset button and the **DO1 led** will change from OFF to ON. When **DO1 LED** is on, it means the device is in download mode. 1769 +Hold down the PRO button and then momentarily press the RST reset button and the (% style="color:red" %)**DO1 led**(%%) will change from OFF to ON. When (% style="color:red" %)**DO1 LED**(%%) is on, it means the device is in download mode. 1799 1799 ))) 1800 1800 1801 1801 [[image:image-20220524103407-12.png]] ... ... @@ -1889,6 +1889,8 @@ 1889 1889 == 5.5 Can i use point to point communication for LT-22222-L? == 1890 1890 1891 1891 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1863 + 1864 + 1892 1892 ))) 1893 1893 1894 1894 ((( ... ... @@ -1902,12 +1902,13 @@ 1902 1902 1903 1903 After restart, the status before power failure will be read from flash. 1904 1904 1878 + 1905 1905 = 6. Trouble Shooting = 1906 1906 ))) 1907 1907 1908 1908 ((( 1909 1909 ((( 1910 -== 6.1 Downlink doesn ’t work, how to solve it? ==1884 +== 6.1 Downlink doesn't work, how to solve it? == 1911 1911 ))) 1912 1912 ))) 1913 1913 ... ... @@ -1928,7 +1928,7 @@ 1928 1928 ((( 1929 1929 1930 1930 1931 -== 6.3 Why I can ’t join TTN in US915 /AU915 bands? ==1905 +== 6.3 Why I can't join TTN in US915 /AU915 bands? == 1932 1932 ))) 1933 1933 1934 1934 ((( ... ... @@ -1936,25 +1936,25 @@ 1936 1936 ))) 1937 1937 1938 1938 1939 - 1940 1940 = 7. Order Info = 1941 1941 1942 1942 1943 1943 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1944 1944 1945 - 1946 1946 (% style="color:#4f81bd" %)**XXX:** 1947 1947 1948 -* (% style="color: #4f81bd" %)**EU433**(%%): LT with frequency bands EU4331949 -* (% style="color: #4f81bd" %)**EU868**(%%): LT with frequency bands EU8681950 -* (% style="color: #4f81bd" %)**KR920**(%%): LT with frequency bands KR9201951 -* (% style="color: #4f81bd" %)**CN470**(%%): LT with frequency bands CN4701952 -* (% style="color: #4f81bd" %)**AS923**(%%): LT with frequency bands AS9231953 -* (% style="color: #4f81bd" %)**AU915**(%%): LT with frequency bands AU9151954 -* (% style="color: #4f81bd" %)**US915**(%%): LT with frequency bands US9151955 -* (% style="color: #4f81bd" %)**IN865**(%%): LT with frequency bands IN8651956 -* (% style="color: #4f81bd" %)**CN779**(%%): LT with frequency bands CN7791920 +* (% style="color:red" %)**EU433**(%%): LT with frequency bands EU433 1921 +* (% style="color:red" %)**EU868**(%%): LT with frequency bands EU868 1922 +* (% style="color:red" %)**KR920**(%%): LT with frequency bands KR920 1923 +* (% style="color:red" %)**CN470**(%%): LT with frequency bands CN470 1924 +* (% style="color:red" %)**AS923**(%%): LT with frequency bands AS923 1925 +* (% style="color:red" %)**AU915**(%%): LT with frequency bands AU915 1926 +* (% style="color:red" %)**US915**(%%): LT with frequency bands US915 1927 +* (% style="color:red" %)**IN865**(%%): LT with frequency bands IN865 1928 +* (% style="color:red" %)**CN779**(%%): LT with frequency bands CN779 1957 1957 1930 + 1931 + 1958 1958 = 8. Packing Info = 1959 1959 1960 1960 ... ... @@ -1972,6 +1972,8 @@ 1972 1972 * Package Size / pcs : 14.5 x 8 x 5 cm 1973 1973 * Weight / pcs : 170g 1974 1974 1949 + 1950 + 1975 1975 = 9. Support = 1976 1976 1977 1977 * ((( ... ... @@ -1981,6 +1981,7 @@ 1981 1981 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1982 1982 ))) 1983 1983 1960 + 1984 1984 = 10. Reference = 1985 1985 1986 1986 * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]]
- image-20220714135731-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +54.1 KB - Content
- image-20220719105525-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +165.5 KB - Content
- image-20220719110247-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +52.9 KB - Content