... ... @@ -842,7 +842,10 @@ 842 842 843 843 * (% style="color:#037691" %)AT Command: 844 844 845 +(% class="box infomessage" %) 846 +((( 845 845 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 848 +))) 846 846 847 847 848 848 **Example:** ... ... @@ -851,11 +851,13 @@ 851 851 852 852 * (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 853 853 854 -**0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 857 +(% class="box infomessage" %) 858 +((( 859 +**0xAA 02 aa bb ~/~/ Same as AT+DTRI=aa,bb** 860 +))) 855 855 856 856 857 857 858 - 859 859 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 860 860 861 861 Set DI1 or DI3(for LT-33222-L) trigger. ... ... @@ -862,7 +862,10 @@ 862 862 863 863 * (% style="color:#037691" %)AT Command: 864 864 870 +(% class="box infomessage" %) 871 +((( 865 865 **AT+TRIG1=a,b** 873 +))) 866 866 867 867 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 868 868 ... ... @@ -874,9 +874,12 @@ 874 874 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 875 875 876 876 877 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 878 -* **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 885 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 01 ): 879 879 887 +(% class="box infomessage" %) 888 +((( 889 +**0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 890 +))) 880 880 881 881 882 882 ... ... @@ -884,11 +884,13 @@ 884 884 885 885 Set DI2 trigger. 886 886 887 -* (% style="color:#037691" %) **AT Command:**898 +* (% style="color:#037691" %)AT Command: 888 888 900 +(% class="box infomessage" %) 901 +((( 889 889 **AT+TRIG2=a,b** 903 +))) 890 890 891 - 892 892 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 893 893 894 894 b : delay timing. ... ... @@ -899,71 +899,91 @@ 899 899 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 900 900 901 901 902 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x09 02 ):**915 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 02 ): 903 903 904 -**0x09 02 aa bb cc **~/~/ same as AT+TRIG1=aa,0x(bb cc) 917 +(% class="box infomessage" %) 918 +((( 919 +**0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 920 +))) 905 905 906 906 907 907 908 - 909 909 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 910 910 911 911 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 912 912 913 -* (% style="color:#037691" %) **AT Command**928 +* (% style="color:#037691" %)AT Command: 914 914 915 -**AT+ACLIM** 930 +(% class="box infomessage" %) 931 +((( 932 +**AT+ACLIM. ** 933 +))) 916 916 917 917 918 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAA 01 )**936 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 01 ): 919 919 920 -**0x AA 01 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 938 +(% class="box infomessage" %) 939 +((( 940 +**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 941 +))) 921 921 922 922 923 923 924 - 925 925 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 926 926 927 927 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 928 928 929 -* (% style="color:#037691" %) **AT Command**949 +* (% style="color:#037691" %)AT Command: 930 930 931 -**AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 951 +(% class="box infomessage" %) 952 +((( 953 +**AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 954 +))) 932 932 933 933 934 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAA 00 )**957 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 00 ): 935 935 936 -**0x AA 00 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 959 +(% class="box infomessage" %) 960 +((( 961 +**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ** 962 +))) 937 937 938 938 939 939 940 - 941 941 ==== 3.4.2.11 Trigger – Set minimum interval ==== 942 942 943 943 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 944 944 945 -* (% style="color:#037691" %) **AT Command**970 +* (% style="color:#037691" %)AT Command: 946 946 972 +(% class="box infomessage" %) 973 +((( 947 947 **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.** 975 +))) 948 948 949 949 950 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAC )**978 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAC ): 951 951 952 -**0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 980 +(% class="box infomessage" %) 981 +((( 982 +**0x AC aa bb ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min)** 983 +))) 953 953 954 954 955 955 956 - 957 957 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 958 958 959 -* (% style="color:#037691" %) **AT Command**989 +* (% style="color:#037691" %)AT Command: 960 960 961 961 There is no AT Command to control Digital Output 962 962 963 963 964 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x02)** 965 -* **0x02 aa bb cc **~/~/ Set DO1/DO2/DO3 output 994 +* (% style="color:#037691" %)Downlink Payload (prefix 0x02): 966 966 996 +(% class="box infomessage" %) 997 +((( 998 +**0x02 aa bb cc ~/~/ Set DO1/DO2/DO3 output** 999 +))) 967 967 968 968 ((( 969 969 If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low. ... ... @@ -985,19 +985,22 @@ 985 985 986 986 987 987 988 - 989 989 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 990 990 991 -* (% style="color:#037691" %) **AT Command**1023 +* (% style="color:#037691" %)AT Command: 992 992 993 993 There is no AT Command to control Digital Output 994 994 995 995 996 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xA9)**1028 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA9): 997 997 998 -**0xA9 aa bb cc **~/~/ Set DO1/DO2/DO3 output with time control 1030 +(% class="box infomessage" %) 1031 +((( 1032 +((( 1033 +**0xA9 aa bb cc ~/~/ Set DO1/DO2/DO3 output with time control** 1034 +))) 1035 +))) 999 999 1000 - 1001 1001 This is to control the digital output time of DO pin. Include four bytes: 1002 1002 1003 1003 (% style="color:#4f81bd" %)**First Byte**(%%)**:** Type code (0xA9) ... ... @@ -1051,19 +1051,20 @@ 1051 1051 1052 1052 1053 1053 1054 - 1055 1055 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1056 1056 1057 -* (% style="color:#037691" %) **AT Command:**1092 +* (% style="color:#037691" %)AT Command: 1058 1058 1059 1059 There is no AT Command to control Relay Output 1060 1060 1061 1061 1062 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x03):**1097 +* (% style="color:#037691" %)Downlink Payload (prefix 0x03): 1063 1063 1064 -**0x03 aa bb **~/~/ Set RO1/RO2 output 1099 +(% class="box infomessage" %) 1100 +((( 1101 +**0x03 aa bb ~/~/ Set RO1/RO2 output** 1102 +))) 1065 1065 1066 - 1067 1067 ((( 1068 1068 If payload = 0x030100, it means set RO1 to close and RO2 to open. 1069 1069 ))) ... ... @@ -1080,19 +1080,20 @@ 1080 1080 1081 1081 1082 1082 1083 - 1084 1084 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1085 1085 1086 -* (% style="color:#037691" %) **AT Command:**1122 +* (% style="color:#037691" %)AT Command: 1087 1087 1088 1088 There is no AT Command to control Relay Output 1089 1089 1090 1090 1091 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x05):**1127 +* (% style="color:#037691" %)Downlink Payload (prefix 0x05): 1092 1092 1093 -**0x05 aa bb cc dd **~/~/ Set RO1/RO2 relay with time control 1129 +(% class="box infomessage" %) 1130 +((( 1131 +**0x05 aa bb cc dd ~/~/ Set RO1/RO2 relay with time control:** 1132 +))) 1094 1094 1095 - 1096 1096 This is to control the relay output time of relay. Include four bytes: 1097 1097 1098 1098 (% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05) ... ... @@ -1134,28 +1134,35 @@ 1134 1134 1135 1135 1136 1136 1137 - 1138 1138 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1139 1139 1140 1140 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1141 1141 1142 -* (% style="color:#037691" %) **AT Command:**1179 +* (% style="color:#037691" %)AT Command: 1143 1143 1144 -(% style="color:#037691" %)****(%%)**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1181 +(% class="box infomessage" %) 1182 +((( 1183 +**AT+VOLMAX ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]** 1184 +))) 1145 1145 1146 1146 1147 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xA5):**1187 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA5): 1148 1148 1149 -**0xA5 aa bb cc **~/~/ Same as AT+VOLMAX=(aa bb),cc 1189 +(% class="box infomessage" %) 1190 +((( 1191 +**0xA5 aa bb cc ~/~/ Same as AT+VOLMAX=(aa bb),cc** 1192 +))) 1150 1150 1151 1151 1152 1152 1153 - 1154 1154 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1155 1155 1156 -* (% style="color:#037691" %) **AT Command:**1198 +* (% style="color:#037691" %)AT Command: 1157 1157 1158 -(% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) ** 1200 +(% class="box infomessage" %) 1201 +((( 1202 +**AT+SETCNT=aa,(bb cc dd ee) ** 1203 +))) 1159 1159 1160 1160 aa: 1: Set count1, 1161 1161 ... ... @@ -1166,40 +1166,51 @@ 1166 1166 Bb cc dd ee: number to be set 1167 1167 1168 1168 1169 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xA8):**1214 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA8): 1170 1170 1171 -**0x A8 aa bb cc dd ee **~/~/ same as AT+SETCNT=aa,(bb cc dd ee) 1216 +(% class="box infomessage" %) 1217 +((( 1218 +**0x A8 aa bb cc dd ee ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)** 1219 +))) 1172 1172 1173 1173 1174 1174 1175 - 1176 1176 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1177 1177 1178 1178 Clear counting for counting mode 1179 1179 1180 -* (% style="color:#037691" %) **AT Command:**1227 +* (% style="color:#037691" %)AT Command: 1181 1181 1182 -(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1229 +(% class="box infomessage" %) 1230 +((( 1231 +**AT+CLRCOUNT ~/~/ clear all counting** 1232 +))) 1183 1183 1234 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA6): 1184 1184 1185 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** 1236 +(% class="box infomessage" %) 1237 +((( 1238 +**0x A6 01 ~/~/ clear all counting,** 1239 +))) 1186 1186 1187 -**0x A6 01 ** ~/~/ clear all counting 1188 1188 1189 1189 1190 - 1191 - 1192 1192 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1193 1193 1194 -* (% style="color:#037691" %) **AT Command:**1245 +* (% style="color:#037691" %)AT Command: 1195 1195 1196 -**AT+COUTIME=60 **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30) 1247 +(% class="box infomessage" %) 1248 +((( 1249 +**AT+COUTIME=60 ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)** 1250 +))) 1197 1197 1252 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA7): 1198 1198 1199 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA7):** 1254 +(% class="box infomessage" %) 1255 +((( 1256 +**0x A7 aa bb cc ~/~/ same as AT+COUTIME =aa bb cc,** 1257 +))) 1200 1200 1201 -**0x A7 aa bb cc **~/~/ same as AT+COUTIME =aa bb cc, 1202 - 1203 1203 ((( 1204 1204 range: aa bb cc:0 to 16777215, (unit:second) 1205 1205 ... ... @@ -1207,7 +1207,6 @@ 1207 1207 ))) 1208 1208 1209 1209 1210 - 1211 1211 == 3.5 Integrate with Mydevice == 1212 1212 1213 1213 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: