Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -181,8 +181,6 @@ 181 181 * Firmware upgradable via program port 182 182 * Counting 183 183 184 - 185 - 186 186 == 1.4 Applications == 187 187 188 188 * Smart Buildings & Home Automation ... ... @@ -192,8 +192,6 @@ 192 192 * Smart Cities 193 193 * Smart Factory 194 194 195 - 196 - 197 197 == 1.5 Hardware Variants == 198 198 199 199 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -208,6 +208,7 @@ 208 208 ))) 209 209 210 210 207 + 211 211 = 2. Power ON Device = 212 212 213 213 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -288,8 +288,6 @@ 288 288 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 289 289 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 290 290 291 - 292 - 293 293 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 294 294 295 295 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -343,8 +343,6 @@ 343 343 ** DO1 is high in case there is load between DO1 and V+. 344 344 ** DO1 LED is off in both case 345 345 346 - 347 - 348 348 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 349 349 350 350 ... ... @@ -394,24 +394,20 @@ 394 394 395 395 ((( 396 396 **For LT22222-L:** 397 -))) 398 398 399 -(% class="box infomessage" %) 400 -((( 401 -((( 402 -**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 403 403 404 -**AT+TRIG1= 1,100(set DI1 port to trigger onhighlevel, valid signal is 100ms392 +(% style="color:blue" %)**AT+TRIG1=0,100**(%%)** (set DI1 port to trigger on low level, valid signal is 100ms) ** 405 405 406 -**AT+TRIG 2=0,100 (set DI2port to trigger onlowlevel, valid signal is 100ms) **394 +(% style="color:blue" %)**AT+TRIG1=1,100**(%%)** (set DI1 port to trigger on high level, valid signal is 100ms ) ** 407 407 408 -**AT+TRIG2= 1,100 (set DI2 port to trigger onhighlevel, valid signal is 100ms396 +(% style="color:blue" %)**AT+TRIG2=0,100**(%%)** (set DI2 port to trigger on low level, valid signal is 100ms) ** 409 409 410 -**AT+ SETCNT=1,60SetCOUNT1valueto60)**398 +(% style="color:blue" %)**AT+TRIG2=1,100**(%%)** (set DI2 port to trigger on high level, valid signal is 100ms ) ** 411 411 412 -**AT+SETCNT=2,60 (Set COUNT2 value to 60)** 400 +(% style="color:blue" %)**AT+SETCNT=1,60**(%%)** (Set COUNT1 value to 60)** 401 + 402 +(% style="color:blue" %)**AT+SETCNT=2,60**(%%)** (Set COUNT2 value to 60)** 413 413 ))) 414 -))) 415 415 416 416 417 417 ... ... @@ -503,22 +503,19 @@ 503 503 504 504 505 505 **Plus below command for AVI1 Counting:** 506 -))) 507 507 508 -(% class="box infomessage" %) 509 -((( 510 -((( 511 -(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 512 512 513 -(% style="color:blue" %)**AT+ VOLMAX=20000**(%%)**(IfAVI1voltagehigherthanVOLMAX(20000mV=20v), counterincrease1)**497 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 514 514 515 -(% style="color:blue" %)**AT+VOLMAX=20000 ,0**(%%)**lower than VOLMAX (20000mV =20v), counter increase 1)**499 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 516 516 517 -(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 501 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 502 + 503 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 518 518 ))) 519 -))) 520 520 521 521 507 + 522 522 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 523 523 524 524 ... ... @@ -578,6 +578,7 @@ 578 578 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 579 579 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 580 580 567 + 581 581 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 582 582 583 583 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -719,8 +719,6 @@ 719 719 720 720 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 721 721 722 - 723 - 724 724 === 3.4.1 Common Commands === 725 725 726 726 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -735,23 +735,19 @@ 735 735 736 736 * (% style="color:#037691" %)**AT Command:** 737 737 738 -(% class="box infomessage" %) 739 -((( 740 740 **AT+TDC=N ** 741 -))) 742 742 725 + 743 743 **Example: **AT+TDC=30000. Means set interval to 30 seconds 744 744 745 745 746 746 * (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 747 747 748 -(% class="box infomessage" %) 749 -((( 750 750 **0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 751 -))) 752 752 753 753 754 754 735 + 755 755 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 756 756 757 757 Set work mode. ... ... @@ -758,36 +758,29 @@ 758 758 759 759 * (% style="color:#037691" %)**AT Command:** 760 760 761 -(% class="box infomessage" %) 762 -((( 763 763 **AT+MOD=N ** 764 -))) 765 765 744 + 766 766 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 767 767 768 768 769 769 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 770 770 771 -(% class="box infomessage" %) 772 -((( 773 -**0x0A aa ~/~/ Same as AT+MOD=aa** 774 -))) 750 +**0x0A aa ** ~/~/ Same as AT+MOD=aa 775 775 776 776 777 777 754 + 778 778 ==== 3.4.2.3 Poll an uplink ==== 779 779 780 -* (% style="color:#037691" %)AT Command: 757 +* (% style="color:#037691" %)**AT Command:** 781 781 782 782 There is no AT Command to poll uplink 783 783 784 784 785 -* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 762 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x08):** 786 786 787 -(% class="box infomessage" %) 788 -((( 789 -**0x08 FF ~/~/ Poll an uplink,** 790 -))) 764 +**0x08 FF **~/~/ Poll an uplink 791 791 792 792 **Example**: 0x08FF, ask device to send an Uplink 793 793 ... ... @@ -797,12 +797,9 @@ 797 797 798 798 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 799 799 800 -* (% style="color:#037691" %)AT Command: 774 +* (% style="color:#037691" %)**AT Command:** 801 801 802 -(% class="box infomessage" %) 803 -((( 804 804 **AT+ADDMOD6=1 or 0** 805 -))) 806 806 807 807 1: Enable Trigger Mode 808 808 ... ... @@ -809,43 +809,36 @@ 809 809 0: Disable Trigger Mode 810 810 811 811 812 -* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 783 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):** 813 813 814 -(% class="box infomessage" %) 815 -((( 816 -**0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 817 -))) 785 +**0x0A 06 aa ** ~/~/ Same as AT+ADDMOD6=aa 818 818 819 819 820 820 789 + 821 821 ==== 3.4.2.5 Poll trigger settings ==== 822 822 823 823 Poll trigger settings, 824 824 825 -* (% style="color:#037691" %)AT Command: 794 +* (% style="color:#037691" %)**AT Command:** 826 826 827 827 There is no AT Command for this feature. 828 828 829 829 830 -* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 799 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):** 831 831 832 -(% class="box infomessage" %) 833 -((( 834 -**0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 835 -))) 801 +**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 836 836 837 837 838 838 805 + 839 839 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 840 840 841 841 Enable Disable DI1/DI2/DI2 as trigger, 842 842 843 -* (% style="color:#037691" %)AT Command: 810 +* (% style="color:#037691" %)**AT Command:** 844 844 845 -(% class="box infomessage" %) 846 -((( 847 847 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 848 -))) 849 849 850 850 851 851 **Example:** ... ... @@ -852,9 +852,9 @@ 852 852 853 853 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 854 854 855 -* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 819 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):** 856 856 857 -**0xAA 02 aa bb 821 +**0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 858 858 859 859 860 860 ... ... @@ -863,7 +863,7 @@ 863 863 864 864 Set DI1 or DI3(for LT-33222-L) trigger. 865 865 866 -* (% style="color:#037691" %)AT Command: 830 +* (% style="color:#037691" %)**AT Command:** 867 867 868 868 **AT+TRIG1=a,b** 869 869 ... ... @@ -878,7 +878,7 @@ 878 878 879 879 880 880 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 881 -* **0x09 01 aa bb cc 845 +* **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 882 882 883 883 884 884 ... ... @@ -904,7 +904,7 @@ 904 904 905 905 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):** 906 906 907 -**0x09 02 aa bb cc 871 +**0x09 02 aa bb cc **~/~/ same as AT+TRIG1=aa,0x(bb cc) 908 908 909 909 910 910 ... ... @@ -920,7 +920,7 @@ 920 920 921 921 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )** 922 922 923 -**0x AA 01 aa bb cc dd ee ff gg hh 887 +**0x AA 01 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 924 924 925 925 926 926 ... ... @@ -936,7 +936,7 @@ 936 936 937 937 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )** 938 938 939 -**0x AA 00 aa bb cc dd ee ff gg hh 903 +**0x AA 00 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 940 940 941 941 942 942 ... ... @@ -943,16 +943,16 @@ 943 943 944 944 ==== 3.4.2.11 Trigger – Set minimum interval ==== 945 945 946 -Set AV and AC trigger minimum interval, system won ’t response to the second trigger within this set time after the first trigger.910 +Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger. 947 947 948 948 * (% style="color:#037691" %)**AT Command** 949 949 950 -**AT+ATDC=5 .Device won’t response the second trigger within 5 minute after the first trigger.**914 +**AT+ATDC=5 ** Device won't response the second trigger within 5 minute after the first trigger. 951 951 952 952 953 953 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** 954 954 955 -**0x AC aa bb 919 +**0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 956 956 957 957 958 958 ... ... @@ -967,7 +967,6 @@ 967 967 * (% style="color:#037691" %)**Downlink Payload (prefix 0x02)** 968 968 * **0x02 aa bb cc **~/~/ Set DO1/DO2/DO3 output 969 969 970 - 971 971 ((( 972 972 If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low. 973 973 ))) ... ... @@ -1144,7 +1144,7 @@ 1144 1144 1145 1145 * (% style="color:#037691" %)**AT Command:** 1146 1146 1147 - (% style="color:#037691" %)****(%%)**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]1110 +**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1148 1148 1149 1149 1150 1150 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** ... ... @@ -1158,7 +1158,7 @@ 1158 1158 1159 1159 * (% style="color:#037691" %)**AT Command:** 1160 1160 1161 - (% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) **1124 +**AT+SETCNT=aa,(bb cc dd ee) ** 1162 1162 1163 1163 aa: 1: Set count1, 1164 1164 ... ... @@ -1182,7 +1182,7 @@ 1182 1182 1183 1183 * (% style="color:#037691" %)**AT Command:** 1184 1184 1185 -(% style="color:#037691" %) (%%)**AT+CLRCOUNT ** ~/~/ clear all counting1148 +(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1186 1186 1187 1187 1188 1188 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** ... ... @@ -1440,6 +1440,7 @@ 1440 1440 [[image:image-20220524100748-11.png]] 1441 1441 1442 1442 1406 + 1443 1443 = 4. Use AT Command = 1444 1444 1445 1445 == 4.1 Access AT Command == ... ... @@ -1642,8 +1642,6 @@ 1642 1642 1643 1643 ((( 1644 1644 AT+CFG: Print all settings 1645 - 1646 - 1647 1647 ))) 1648 1648 1649 1649 ... ... @@ -1689,8 +1689,6 @@ 1689 1689 1690 1690 ((( 1691 1691 (% style="background-color:#dcdcdc" %)ATZ 1692 - 1693 - 1694 1694 ))) 1695 1695 1696 1696 ... ... @@ -1897,6 +1897,8 @@ 1897 1897 == 5.5 Can i use point to point communication for LT-22222-L? == 1898 1898 1899 1899 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1860 + 1861 + 1900 1900 ))) 1901 1901 1902 1902 ((( ... ... @@ -1910,6 +1910,7 @@ 1910 1910 1911 1911 After restart, the status before power failure will be read from flash. 1912 1912 1875 + 1913 1913 = 6. Trouble Shooting = 1914 1914 ))) 1915 1915 ... ... @@ -1963,6 +1963,9 @@ 1963 1963 * (% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865 1964 1964 * (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779 1965 1965 1929 + 1930 + 1931 + 1966 1966 = 8. Packing Info = 1967 1967 1968 1968 ... ... @@ -1980,6 +1980,9 @@ 1980 1980 * Package Size / pcs : 14.5 x 8 x 5 cm 1981 1981 * Weight / pcs : 170g 1982 1982 1949 + 1950 + 1951 + 1983 1983 = 9. Support = 1984 1984 1985 1985 * ((( ... ... @@ -1987,6 +1987,10 @@ 1987 1987 ))) 1988 1988 * ((( 1989 1989 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1959 + 1960 + 1961 + 1962 + 1990 1990 ))) 1991 1991 1992 1992 = 10. Reference =