Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,7 +1,6 @@ 1 1 (% style="text-align:center" %) 2 2 [[image:image-20220523163353-1.jpeg||height="604" width="500"]] 3 3 4 -**LT-22222-L LoRa IO Controller User Manual ** 5 5 6 6 7 7 **Table of Contents:** ... ... @@ -42,6 +42,8 @@ 42 42 43 43 ((( 44 44 2) User can set up a LoRaWAN gateway locally and configure the controller to connect to the gateway via wireless. 44 + 45 + 45 45 ))) 46 46 47 47 ((( ... ... @@ -173,6 +173,7 @@ 173 173 174 174 == 1.3 Features == 175 175 177 + 176 176 * LoRaWAN Class A & Class C protocol 177 177 * Optional Customized LoRa Protocol 178 178 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865 ... ... @@ -183,8 +183,11 @@ 183 183 184 184 185 185 188 + 189 + 186 186 == 1.4 Applications == 187 187 192 + 188 188 * Smart Buildings & Home Automation 189 189 * Logistics and Supply Chain Management 190 190 * Smart Metering ... ... @@ -194,8 +194,11 @@ 194 194 195 195 196 196 202 + 203 + 197 197 == 1.5 Hardware Variants == 198 198 206 + 199 199 (% border="1" style="background-color:#f7faff; width:500px" %) 200 200 |(% style="width:103px" %)**Model**|(% style="width:131px" %)**Photo**|(% style="width:334px" %)**Description** 201 201 |(% style="width:103px" %)**LT22222-L**|(% style="width:131px" %)[[image:1653296302983-697.png]]|(% style="width:334px" %)((( ... ... @@ -208,8 +208,11 @@ 208 208 ))) 209 209 210 210 219 + 220 + 211 211 = 2. Power ON Device = 212 212 223 + 213 213 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. 214 214 215 215 ((( ... ... @@ -224,19 +224,24 @@ 224 224 225 225 == 3.1 How it works? == 226 226 238 + 227 227 ((( 228 -The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on **TX LED** will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. **TX LED** will be on for 5 seconds after joined in network. When there is message from server, the **RX LED**will be on for 1 second.240 +The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%) will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. (% style="color:green" %)**TX LED**(%%) will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second. 229 229 ))) 230 230 231 231 ((( 232 -In case user can ’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.244 +In case user can't set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 233 233 ))) 234 234 235 235 248 + 236 236 == 3.2 Example to join LoRaWAN network == 237 237 251 + 238 238 ((( 239 239 This chapter shows an example for how to join the TTN LoRaWAN Network. Below is the network structure, we use our LG308 as LoRaWAN gateway here. 254 + 255 + 240 240 ))) 241 241 242 242 [[image:image-20220523172350-1.png||height="266" width="864"]] ... ... @@ -244,6 +244,8 @@ 244 244 245 245 ((( 246 246 The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN: 263 + 264 + 247 247 ))) 248 248 249 249 ((( ... ... @@ -281,15 +281,13 @@ 281 281 282 282 There are five working modes + one interrupt mode on LT for different type application: 283 283 284 -* **MOD1**: (default setting): 2 x ACI + 2AVI + DI + DO + RO 285 -* **MOD2**: Double DI Counting + DO + RO 286 -* **MOD3**: Single DI Counting + 2 x ACI + DO + RO 287 -* **MOD4**: Single DI Counting + 1 x Voltage Counting + DO + RO 288 -* **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 289 -* **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 302 +* (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO 303 +* (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO 304 +* (% style="color:blue" %)**MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO 305 +* (% style="color:blue" %)**MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO 306 +* (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 307 +* (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5 290 290 291 - 292 - 293 293 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 294 294 295 295 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -343,8 +343,6 @@ 343 343 ** DO1 is high in case there is load between DO1 and V+. 344 344 ** DO1 LED is off in both case 345 345 346 - 347 - 348 348 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 349 349 350 350 ... ... @@ -394,24 +394,20 @@ 394 394 395 395 ((( 396 396 **For LT22222-L:** 397 -))) 398 398 399 -(% class="box infomessage" %) 400 -((( 401 -((( 402 -**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 403 403 404 -**AT+TRIG1= 1,100(set DI1 port to trigger onhighlevel, valid signal is 100ms413 +(% style="color:blue" %)**AT+TRIG1=0,100**(%%)** (set DI1 port to trigger on low level, valid signal is 100ms) ** 405 405 406 -**AT+TRIG 2=0,100 (set DI2port to trigger onlowlevel, valid signal is 100ms) **415 +(% style="color:blue" %)**AT+TRIG1=1,100**(%%)** (set DI1 port to trigger on high level, valid signal is 100ms ) ** 407 407 408 -**AT+TRIG2= 1,100 (set DI2 port to trigger onhighlevel, valid signal is 100ms417 +(% style="color:blue" %)**AT+TRIG2=0,100**(%%)** (set DI2 port to trigger on low level, valid signal is 100ms) ** 409 409 410 -**AT+ SETCNT=1,60SetCOUNT1valueto60)**419 +(% style="color:blue" %)**AT+TRIG2=1,100**(%%)** (set DI2 port to trigger on high level, valid signal is 100ms ) ** 411 411 412 -**AT+SETCNT=2,60 (Set COUNT2 value to 60)** 421 +(% style="color:blue" %)**AT+SETCNT=1,60**(%%)** (Set COUNT1 value to 60)** 422 + 423 +(% style="color:blue" %)**AT+SETCNT=2,60**(%%)** (Set COUNT2 value to 60)** 413 413 ))) 414 -))) 415 415 416 416 417 417 ... ... @@ -422,6 +422,8 @@ 422 422 [[image:image-20220523181246-5.png]] 423 423 424 424 ((( 435 + 436 + 425 425 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 426 426 ))) 427 427 ... ... @@ -435,6 +435,7 @@ 435 435 (% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 436 436 ))) 437 437 450 + 438 438 ((( 439 439 **To use counting mode, please run:** 440 440 ))) ... ... @@ -503,22 +503,19 @@ 503 503 504 504 505 505 **Plus below command for AVI1 Counting:** 506 -))) 507 507 508 -(% class="box infomessage" %) 509 -((( 510 -((( 511 -(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 512 512 513 -(% style="color:blue" %)**AT+ VOLMAX=20000**(%%)**(IfAVI1voltagehigherthanVOLMAX(20000mV=20v), counterincrease1)**521 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 514 514 515 -(% style="color:blue" %)**AT+VOLMAX=20000 ,0**(%%)**lower than VOLMAX (20000mV =20v), counter increase 1)**523 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 516 516 517 -(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 525 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 526 + 527 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 518 518 ))) 519 -))) 520 520 521 521 531 + 522 522 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 523 523 524 524 ... ... @@ -570,8 +570,8 @@ 570 570 571 571 For example, if user has configured below commands: 572 572 573 -* **AT+MOD=1 ** **~-~->** The normal working mode 574 -* **AT+ADDMOD6=1** **~-~->** Enable trigger 583 +* **AT+MOD=1 ** **~-~->** The normal working mode 584 +* **AT+ADDMOD6=1** **~-~->** Enable trigger 575 575 576 576 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 577 577 ... ... @@ -580,6 +580,7 @@ 580 580 581 581 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 582 582 593 + 583 583 (% style="color:#4f81bd" %)**Trigger base on voltage**: 584 584 585 585 Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH> ... ... @@ -719,8 +719,6 @@ 719 719 720 720 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 721 721 722 - 723 - 724 724 === 3.4.1 Common Commands === 725 725 726 726 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -729,6 +729,7 @@ 729 729 730 730 === 3.4.2 Sensor related commands === 731 731 741 + 732 732 ==== 3.4.2.1 Set Transmit Interval ==== 733 733 734 734 Set device uplink interval. ... ... @@ -735,23 +735,19 @@ 735 735 736 736 * (% style="color:#037691" %)**AT Command:** 737 737 738 -(% class="box infomessage" %) 739 -((( 740 740 **AT+TDC=N ** 741 -))) 742 742 750 + 743 743 **Example: **AT+TDC=30000. Means set interval to 30 seconds 744 744 745 745 746 746 * (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 747 747 748 -(% class="box infomessage" %) 749 -((( 750 750 **0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 751 -))) 752 752 753 753 754 754 760 + 755 755 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 756 756 757 757 Set work mode. ... ... @@ -758,51 +758,42 @@ 758 758 759 759 * (% style="color:#037691" %)**AT Command:** 760 760 761 -(% class="box infomessage" %) 762 -((( 763 763 **AT+MOD=N ** 764 -))) 765 765 769 + 766 766 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 767 767 768 768 769 769 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 770 770 771 -(% class="box infomessage" %) 772 -((( 773 -**0x0A aa ~/~/ Same as AT+MOD=aa** 774 -))) 775 +**0x0A aa ** ~/~/ Same as AT+MOD=aa 775 775 776 776 777 777 779 + 778 778 ==== 3.4.2.3 Poll an uplink ==== 779 779 780 -* (% style="color:#037691" %)AT Command: 782 +* (% style="color:#037691" %)**AT Command:** 781 781 782 782 There is no AT Command to poll uplink 783 783 784 784 785 -* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 787 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x08):** 786 786 787 -(% class="box infomessage" %) 788 -((( 789 -**0x08 FF ~/~/ Poll an uplink,** 790 -))) 789 +**0x08 FF **~/~/ Poll an uplink 791 791 792 792 **Example**: 0x08FF, ask device to send an Uplink 793 793 794 794 795 795 795 + 796 796 ==== 3.4.2.4 Enable Trigger Mode ==== 797 797 798 798 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 799 799 800 -* (% style="color:#037691" %)AT Command: 800 +* (% style="color:#037691" %)**AT Command:** 801 801 802 -(% class="box infomessage" %) 803 -((( 804 804 **AT+ADDMOD6=1 or 0** 805 -))) 806 806 807 807 1: Enable Trigger Mode 808 808 ... ... @@ -809,43 +809,36 @@ 809 809 0: Disable Trigger Mode 810 810 811 811 812 -* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 809 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):** 813 813 814 -(% class="box infomessage" %) 815 -((( 816 -**0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 817 -))) 811 +**0x0A 06 aa ** ~/~/ Same as AT+ADDMOD6=aa 818 818 819 819 820 820 815 + 821 821 ==== 3.4.2.5 Poll trigger settings ==== 822 822 823 823 Poll trigger settings, 824 824 825 -* (% style="color:#037691" %)AT Command: 820 +* (% style="color:#037691" %)**AT Command:** 826 826 827 827 There is no AT Command for this feature. 828 828 829 829 830 -* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 825 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):** 831 831 832 -(% class="box infomessage" %) 833 -((( 834 -**0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 835 -))) 827 +**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 836 836 837 837 838 838 831 + 839 839 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 840 840 841 841 Enable Disable DI1/DI2/DI2 as trigger, 842 842 843 -* (% style="color:#037691" %)AT Command: 836 +* (% style="color:#037691" %)**AT Command:** 844 844 845 -(% class="box infomessage" %) 846 -((( 847 847 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 848 -))) 849 849 850 850 851 851 **Example:** ... ... @@ -852,20 +852,18 @@ 852 852 853 853 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 854 854 855 -* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 845 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):** 856 856 857 -(% class="box infomessage" %) 858 -((( 859 -**0xAA 02 aa bb ~/~/ Same as AT+DTRI=aa,bb** 860 -))) 847 +**0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 861 861 862 862 863 863 851 + 864 864 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 865 865 866 866 Set DI1 or DI3(for LT-33222-L) trigger. 867 867 868 -* (% style="color:#037691" %)AT Command: 856 +* (% style="color:#037691" %)**AT Command:** 869 869 870 870 **AT+TRIG1=a,b** 871 871 ... ... @@ -880,11 +880,8 @@ 880 880 881 881 882 882 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 883 -* **0x09 01 aa bb cc 871 +* **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 884 884 885 - 886 - 887 - 888 888 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 889 889 890 890 Set DI2 trigger. ... ... @@ -906,7 +906,7 @@ 906 906 907 907 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):** 908 908 909 -**0x09 02 aa bb cc 894 +**0x09 02 aa bb cc **~/~/ same as AT+TRIG1=aa,0x(bb cc) 910 910 911 911 912 912 ... ... @@ -922,7 +922,7 @@ 922 922 923 923 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )** 924 924 925 -**0x AA 01 aa bb cc dd ee ff gg hh 910 +**0x AA 01 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 926 926 927 927 928 928 ... ... @@ -938,7 +938,7 @@ 938 938 939 939 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )** 940 940 941 -**0x AA 00 aa bb cc dd ee ff gg hh 926 +**0x AA 00 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 942 942 943 943 944 944 ... ... @@ -945,20 +945,26 @@ 945 945 946 946 ==== 3.4.2.11 Trigger – Set minimum interval ==== 947 947 948 -Set AV and AC trigger minimum interval, system won ’t response to the second trigger within this set time after the first trigger.933 +Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger. 949 949 950 950 * (% style="color:#037691" %)**AT Command** 951 951 952 -**AT+ATDC=5 .Device won’t response the second trigger within 5 minute after the first trigger.**937 +**AT+ATDC=5 ** Device won't response the second trigger within 5 minute after the first trigger. 953 953 954 954 955 955 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** 956 956 957 -**0x AC aa bb 942 +**0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 958 958 944 +((( 945 + 959 959 947 +(% style="color:red" %)Note: ATDC setting must be more than 5min 948 +))) 960 960 961 961 951 + 952 + 962 962 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 963 963 964 964 * (% style="color:#037691" %)**AT Command** ... ... @@ -969,7 +969,6 @@ 969 969 * (% style="color:#037691" %)**Downlink Payload (prefix 0x02)** 970 970 * **0x02 aa bb cc **~/~/ Set DO1/DO2/DO3 output 971 971 972 - 973 973 ((( 974 974 If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low. 975 975 ))) ... ... @@ -1111,7 +1111,7 @@ 1111 1111 1112 1112 (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status: 1113 1113 1114 -[[image:image-20220 524093831-10.png]]1104 +[[image:image-20220714135731-1.png||height="406" width="627"]] 1115 1115 1116 1116 1117 1117 (% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms ... ... @@ -1121,21 +1121,21 @@ 1121 1121 1122 1122 **Example payload:** 1123 1123 1124 -**~1. 05 01 11 07 D 0**1114 +**~1. 05 01 11 07 D** 1125 1125 1126 -Relay1 and Relay 2 will be set to N O, last 2 seconds, then change back to original state.1116 +Relay1 and Relay 2 will be set to NC , last 2 seconds, then change back to original state. 1127 1127 1128 1128 **2. 05 01 10 07 D0** 1129 1129 1130 -Relay1 will change to N O, Relay2 will change to NC, last 2 seconds, then both change back to original state.1120 +Relay1 will change to NC, Relay2 will change to NO, last 2 seconds, then both change back to original state. 1131 1131 1132 1132 **3. 05 00 01 07 D0** 1133 1133 1134 -Relay1 will change to N C, Relay2 will change to NO, last 2 seconds, then relay change to NO,C.1124 +Relay1 will change to NO, Relay2 will change to NC, last 2 seconds, then relay change to NC,Relay2 change to NO. 1135 1135 1136 1136 **4. 05 00 00 07 D0** 1137 1137 1138 -Relay 1 & relay2 will change to N C, last 2 seconds, then both change to NO.1128 +Relay 1 & relay2 will change to NO, last 2 seconds, then both change to NC. 1139 1139 1140 1140 1141 1141 ... ... @@ -1146,7 +1146,7 @@ 1146 1146 1147 1147 * (% style="color:#037691" %)**AT Command:** 1148 1148 1149 - (% style="color:#037691" %)****(%%)**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]1139 +**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1150 1150 1151 1151 1152 1152 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** ... ... @@ -1160,7 +1160,7 @@ 1160 1160 1161 1161 * (% style="color:#037691" %)**AT Command:** 1162 1162 1163 - (% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) **1153 +**AT+SETCNT=aa,(bb cc dd ee) ** 1164 1164 1165 1165 aa: 1: Set count1, 1166 1166 ... ... @@ -1184,7 +1184,7 @@ 1184 1184 1185 1185 * (% style="color:#037691" %)**AT Command:** 1186 1186 1187 - (% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting1177 +**AT+CLRCOUNT ** ~/~/ clear all counting 1188 1188 1189 1189 1190 1190 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** ... ... @@ -1225,12 +1225,11 @@ 1225 1225 (% style="color:blue" %)**Step 2**(%%): To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps: 1226 1226 ))) 1227 1227 1228 -[[image:1 653356737703-362.png||height="232" width="732"]]1218 +[[image:image-20220719105525-1.png||height="377" width="677"]] 1229 1229 1230 -[[image:image-20220524094641-11.png||height="390" width="723"]] 1231 1231 1232 1232 1233 -[[image:image-20220 524094641-12.png||height="402" width="718"]]1222 +[[image:image-20220719110247-2.png||height="388" width="683"]] 1234 1234 1235 1235 1236 1236 (% style="color:blue" %)**Step 3**(%%): Create an account or log in Mydevices. ... ... @@ -1442,6 +1442,7 @@ 1442 1442 [[image:image-20220524100748-11.png]] 1443 1443 1444 1444 1434 + 1445 1445 = 4. Use AT Command = 1446 1446 1447 1447 == 4.1 Access AT Command == ... ... @@ -1644,8 +1644,6 @@ 1644 1644 1645 1645 ((( 1646 1646 AT+CFG: Print all settings 1647 - 1648 - 1649 1649 ))) 1650 1650 1651 1651 ... ... @@ -1691,8 +1691,6 @@ 1691 1691 1692 1692 ((( 1693 1693 (% style="background-color:#dcdcdc" %)ATZ 1694 - 1695 - 1696 1696 ))) 1697 1697 1698 1698 ... ... @@ -1805,7 +1805,7 @@ 1805 1805 1806 1806 1807 1807 (% style="color:blue" %)**For LT-22222-L**(%%): 1808 -Hold down the PRO button and then momentarily press the RST reset button and the **DO1 led** will change from OFF to ON. When **DO1 LED** is on, it means the device is in download mode. 1794 +Hold down the PRO button and then momentarily press the RST reset button and the (% style="color:red" %)**DO1 led**(%%) will change from OFF to ON. When (% style="color:red" %)**DO1 LED**(%%) is on, it means the device is in download mode. 1809 1809 ))) 1810 1810 1811 1811 [[image:image-20220524103407-12.png]] ... ... @@ -1899,6 +1899,8 @@ 1899 1899 == 5.5 Can i use point to point communication for LT-22222-L? == 1900 1900 1901 1901 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1888 + 1889 + 1902 1902 ))) 1903 1903 1904 1904 ((( ... ... @@ -1912,12 +1912,13 @@ 1912 1912 1913 1913 After restart, the status before power failure will be read from flash. 1914 1914 1903 + 1915 1915 = 6. Trouble Shooting = 1916 1916 ))) 1917 1917 1918 1918 ((( 1919 1919 ((( 1920 -== 6.1 Downlink doesn ’t work, how to solve it? ==1909 +== 6.1 Downlink doesn't work, how to solve it? == 1921 1921 ))) 1922 1922 ))) 1923 1923 ... ... @@ -1938,7 +1938,7 @@ 1938 1938 ((( 1939 1939 1940 1940 1941 -== 6.3 Why I can ’t join TTN in US915 /AU915 bands? ==1930 +== 6.3 Why I can't join TTN in US915 /AU915 bands? == 1942 1942 ))) 1943 1943 1944 1944 ((( ... ... @@ -1946,24 +1946,22 @@ 1946 1946 ))) 1947 1947 1948 1948 1949 - 1950 1950 = 7. Order Info = 1951 1951 1952 1952 1953 1953 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1954 1954 1955 - 1956 1956 (% style="color:#4f81bd" %)**XXX:** 1957 1957 1958 -* (% style="color: #4f81bd" %)**EU433**(%%): LT with frequency bands EU4331959 -* (% style="color: #4f81bd" %)**EU868**(%%): LT with frequency bands EU8681960 -* (% style="color: #4f81bd" %)**KR920**(%%): LT with frequency bands KR9201961 -* (% style="color: #4f81bd" %)**CN470**(%%): LT with frequency bands CN4701962 -* (% style="color: #4f81bd" %)**AS923**(%%): LT with frequency bands AS9231963 -* (% style="color: #4f81bd" %)**AU915**(%%): LT with frequency bands AU9151964 -* (% style="color: #4f81bd" %)**US915**(%%): LT with frequency bands US9151965 -* (% style="color: #4f81bd" %)**IN865**(%%): LT with frequency bands IN8651966 -* (% style="color: #4f81bd" %)**CN779**(%%): LT with frequency bands CN7791945 +* (% style="color:red" %)**EU433**(%%): LT with frequency bands EU433 1946 +* (% style="color:red" %)**EU868**(%%): LT with frequency bands EU868 1947 +* (% style="color:red" %)**KR920**(%%): LT with frequency bands KR920 1948 +* (% style="color:red" %)**CN470**(%%): LT with frequency bands CN470 1949 +* (% style="color:red" %)**AS923**(%%): LT with frequency bands AS923 1950 +* (% style="color:red" %)**AU915**(%%): LT with frequency bands AU915 1951 +* (% style="color:red" %)**US915**(%%): LT with frequency bands US915 1952 +* (% style="color:red" %)**IN865**(%%): LT with frequency bands IN865 1953 +* (% style="color:red" %)**CN779**(%%): LT with frequency bands CN779 1967 1967 1968 1968 = 8. Packing Info = 1969 1969
- image-20220714135731-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +54.1 KB - Content
- image-20220719105525-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +165.5 KB - Content
- image-20220719110247-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +52.9 KB - Content