... ... @@ -867,7 +867,10 @@
867 867  
868 868  * (% style="color:#037691" %)AT Command:
869 869  
870 +(% class="box infomessage" %)
871 +(((
870 870  **AT+TRIG1=a,b**
873 +)))
871 871  
872 872  a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1).
873 873  
... ... @@ -879,9 +879,12 @@
879 879  AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms )
880 880  
881 881  
882 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):**
883 -* **0x09 01 aa bb cc  ** ~/~/ same as AT+TRIG1=aa,0x(bb cc)
885 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 01 ):
884 884  
887 +(% class="box infomessage" %)
888 +(((
889 +**0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)**
890 +)))
885 885  
886 886  
887 887  
... ... @@ -889,11 +889,13 @@
889 889  
890 890  Set DI2 trigger.
891 891  
892 -* (% style="color:#037691" %)**AT Command:**
898 +* (% style="color:#037691" %)AT Command:
893 893  
900 +(% class="box infomessage" %)
901 +(((
894 894  **AT+TRIG2=a,b**
903 +)))
895 895  
896 -
897 897  a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1).
898 898  
899 899  b : delay timing.
... ... @@ -904,71 +904,91 @@
904 904  AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms )
905 905  
906 906  
907 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):**
915 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 02 ):
908 908  
909 -**0x09 02 aa bb cc  **~/~/ same as AT+TRIG1=aa,0x(bb cc)
917 +(% class="box infomessage" %)
918 +(((
919 +**0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)**
920 +)))
910 910  
911 911  
912 912  
913 -
914 914  ==== 3.4.2.9 Trigger – Set AC (current) as trigger ====
915 915  
916 916  Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
917 917  
918 -* (% style="color:#037691" %)**AT Command**
928 +* (% style="color:#037691" %)AT Command:
919 919  
920 -**AT+ACLIM**
930 +(% class="box infomessage" %)
931 +(((
932 +**AT+ACLIM. **
933 +)))
921 921  
922 922  
923 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )**
936 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 01 ):
924 924  
925 -**0x AA 01 aa bb cc dd ee ff gg hh  ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
938 +(% class="box infomessage" %)
939 +(((
940 +**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
941 +)))
926 926  
927 927  
928 928  
929 -
930 930  ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ====
931 931  
932 932  Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
933 933  
934 -* (% style="color:#037691" %)**AT Command**
949 +* (% style="color:#037691" %)AT Command:
935 935  
936 -**AT+AVLIM  See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
951 +(% class="box infomessage" %)
952 +(((
953 +**AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
954 +)))
937 937  
938 938  
939 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )**
957 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 00 ):
940 940  
941 -**0x AA 00 aa bb cc dd ee ff gg hh  ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
959 +(% class="box infomessage" %)
960 +(((
961 +**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] **
962 +)))
942 942  
943 943  
944 944  
945 -
946 946  ==== 3.4.2.11 Trigger – Set minimum interval ====
947 947  
948 948  Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger.
949 949  
950 -* (% style="color:#037691" %)**AT Command**
970 +* (% style="color:#037691" %)AT Command:
951 951  
972 +(% class="box infomessage" %)
973 +(((
952 952  **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.**
975 +)))
953 953  
954 954  
955 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )**
978 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAC ):
956 956  
957 -**0x AC aa bb  ** ~/~/ same as AT+ATDC=0x(aa bb)   . Unit (min)
980 +(% class="box infomessage" %)
981 +(((
982 +**0x AC aa bb ~/~/ same as AT+ATDC=0x(aa bb)   . Unit (min)**
983 +)))
958 958  
959 959  
960 960  
961 -
962 962  ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ====
963 963  
964 -* (% style="color:#037691" %)**AT Command**
989 +* (% style="color:#037691" %)AT Command:
965 965  
966 966  There is no AT Command to control Digital Output
967 967  
968 968  
969 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x02)**
970 -* **0x02 aa bb cc     **~/~/ Set DO1/DO2/DO3 output
994 +* (% style="color:#037691" %)Downlink Payload (prefix 0x02):
971 971  
996 +(% class="box infomessage" %)
997 +(((
998 +**0x02 aa bb cc     ~/~/ Set DO1/DO2/DO3 output**
999 +)))
972 972  
973 973  (((
974 974  If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low.
... ... @@ -990,19 +990,22 @@
990 990  
991 991  
992 992  
993 -
994 994  ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ====
995 995  
996 -* (% style="color:#037691" %)**AT Command**
1023 +* (% style="color:#037691" %)AT Command:
997 997  
998 998  There is no AT Command to control Digital Output
999 999  
1000 1000  
1001 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA9)**
1028 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA9):
1002 1002  
1003 -**0xA9 aa bb cc     **~/~/ Set DO1/DO2/DO3 output with time control
1030 +(% class="box infomessage" %)
1031 +(((
1032 +(((
1033 +**0xA9 aa bb cc     ~/~/ Set DO1/DO2/DO3 output with time control**
1034 +)))
1035 +)))
1004 1004  
1005 -
1006 1006  This is to control the digital output time of DO pin. Include four bytes:
1007 1007  
1008 1008  (% style="color:#4f81bd" %)**First Byte**(%%)**:** Type code (0xA9)
... ... @@ -1056,7 +1056,6 @@
1056 1056  
1057 1057  
1058 1058  
1059 -
1060 1060  ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1061 1061  
1062 1062  * (% style="color:#037691" %)**AT Command:**
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved