... ... @@ -181,8 +181,6 @@
181 181  * Firmware upgradable via program port
182 182  * Counting
183 183  
184 -
185 -
186 186  == 1.4  Applications ==
187 187  
188 188  * Smart Buildings & Home Automation
... ... @@ -192,8 +192,6 @@
192 192  * Smart Cities
193 193  * Smart Factory
194 194  
195 -
196 -
197 197  == 1.5 Hardware Variants ==
198 198  
199 199  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -208,6 +208,7 @@
208 208  )))
209 209  
210 210  
207 +
211 211  = 2. Power ON Device =
212 212  
213 213  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -288,8 +288,6 @@
288 288  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
289 289  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
290 290  
291 -
292 -
293 293  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
294 294  
295 295  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -343,8 +343,6 @@
343 343  ** DO1 is high in case there is load between DO1 and V+.
344 344  ** DO1 LED is off in both case
345 345  
346 -
347 -
348 348  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
349 349  
350 350  
... ... @@ -394,24 +394,20 @@
394 394  
395 395  (((
396 396  **For LT22222-L:**
397 -)))
398 398  
399 -(% class="box infomessage" %)
400 -(((
401 -(((
402 -**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) **
403 403  
404 -**AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) **
392 +(% style="color:blue" %)**AT+TRIG1=0,100**(%%)**  (set DI1 port to trigger on low level, valid signal is 100ms) **
405 405  
406 -**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) **
394 +(% style="color:blue" %)**AT+TRIG1=1,100**(%%)**  (set DI1 port to trigger on high level, valid signal is 100ms ) **
407 407  
408 -**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) **
396 +(% style="color:blue" %)**AT+TRIG2=0,100**(%%)**  (set DI2 port to trigger on low level, valid signal is 100ms) **
409 409  
410 -**AT+SETCNT=1,6  (Set COUNT1 value to 60)**
398 +(% style="color:blue" %)**AT+TRIG2=1,100**(%%)**  (set DI2 port to trigger on high level, valid signal is 100ms ) **
411 411  
412 -**AT+SETCNT=2,60   (Set COUNT2 value to 60)**
400 +(% style="color:blue" %)**AT+SETCNT=1,60**(%%)**   (Set COUNT1 value to 60)**
401 +
402 +(% style="color:blue" %)**AT+SETCNT=2,60**(%%)**   (Set COUNT2 value to 60)**
413 413  )))
414 -)))
415 415  
416 416  
417 417  
... ... @@ -503,22 +503,19 @@
503 503  
504 504  
505 505  **Plus below command for AVI1 Counting:**
506 -)))
507 507  
508 -(% class="box infomessage" %)
509 -(((
510 -(((
511 -(% style="color:blue" %)**AT+SETCNT=3,60**(%%)**   (set AVI Count to 60)**
512 512  
513 -(% style="color:blue" %)**AT+VOLMAX=20000**(%%)**   (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)**
497 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)**  (set AVI Count to 60)**
514 514  
515 -(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)**   (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)**
499 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)**  (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)**
516 516  
517 -(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)**   (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)**
501 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)**  (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)**
502 +
503 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)**  (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)**
518 518  )))
519 -)))
520 520  
521 521  
507 +
522 522  === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI ===
523 523  
524 524  
... ... @@ -578,6 +578,7 @@
578 578  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
579 579  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
580 580  
567 +
581 581  (% style="color:#037691" %)**AT Command to set Trigger Condition**:
582 582  
583 583  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -719,8 +719,6 @@
719 719  
720 720  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
721 721  
722 -
723 -
724 724  === 3.4.1 Common Commands ===
725 725  
726 726  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -842,10 +842,7 @@
842 842  
843 843  * (% style="color:#037691" %)AT Command:
844 844  
845 -(% class="box infomessage" %)
846 -(((
847 847  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
848 -)))
849 849  
850 850  
851 851  **Example:**
... ... @@ -854,13 +854,11 @@
854 854  
855 855  * (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02):
856 856  
857 -(% class="box infomessage" %)
858 -(((
859 -**0xAA 02 aa bb  ~/~/ Same as AT+DTRI=aa,bb**
860 -)))
839 +**0xAA 02 aa bb        **~/~/ Same as AT+DTRI=aa,bb
861 861  
862 862  
863 863  
843 +
864 864  ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ====
865 865  
866 866  Set DI1 or DI3(for LT-33222-L) trigger.
... ... @@ -867,10 +867,7 @@
867 867  
868 868  * (% style="color:#037691" %)AT Command:
869 869  
870 -(% class="box infomessage" %)
871 -(((
872 872  **AT+TRIG1=a,b**
873 -)))
874 874  
875 875  a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1).
876 876  
... ... @@ -882,15 +882,10 @@
882 882  AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms )
883 883  
884 884  
885 -* (% style="color:#037691" %)Downlink Payload (prefix 0x09 01 ):
862 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):**
863 +* **0x09 01 aa bb cc    ** ~/~/ same as AT+TRIG1=aa,0x(bb cc)
886 886  
887 -(% class="box infomessage" %)
888 -(((
889 -**0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)**
890 -)))
891 891  
892 -
893 -
894 894  ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
895 895  
896 896  Set DI2 trigger.
... ... @@ -912,7 +912,7 @@
912 912  
913 913  * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):**
914 914  
915 -**0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)**
887 +**0x09 02 aa bb cc           **~/~/ same as AT+TRIG1=aa,0x(bb cc)
916 916  
917 917  
918 918  
... ... @@ -928,7 +928,7 @@
928 928  
929 929  * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )**
930 930  
931 -**0x AA 01 aa bb cc dd ee ff gg hh  ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
903 +**0x AA 01 aa bb cc dd ee ff gg hh        ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
932 932  
933 933  
934 934  
... ... @@ -944,7 +944,7 @@
944 944  
945 945  * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )**
946 946  
947 -**0x AA 00 aa bb cc dd ee ff gg hh  ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
919 +**0x AA 00 aa bb cc dd ee ff gg hh    ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
948 948  
949 949  
950 950  
... ... @@ -960,7 +960,7 @@
960 960  
961 961  * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )**
962 962  
963 -**0x AC aa bb  ** ~/~/ same as AT+ATDC=0x(aa bb)   . Unit (min)
935 +**0x AC aa bb   ** ~/~/ same as AT+ATDC=0x(aa bb)   . Unit (min)
964 964  
965 965  
966 966  
... ... @@ -975,7 +975,6 @@
975 975  * (% style="color:#037691" %)**Downlink Payload (prefix 0x02)**
976 976  * **0x02 aa bb cc     **~/~/ Set DO1/DO2/DO3 output
977 977  
978 -
979 979  (((
980 980  If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low.
981 981  )))
... ... @@ -1152,7 +1152,7 @@
1152 1152  
1153 1153  * (% style="color:#037691" %)**AT Command:**
1154 1154  
1155 -(% style="color:#037691" %)**​​​​​​​**(%%)**AT+VOLMAX   ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1126 +**AT+VOLMAX   ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1156 1156  
1157 1157  
1158 1158  * (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):**
... ... @@ -1166,7 +1166,7 @@
1166 1166  
1167 1167  * (% style="color:#037691" %)**AT Command:**
1168 1168  
1169 -(% style="color:#037691" %)**​​​​​​​​​​​​​​**(%%)**AT+SETCNT=aa,(bb cc dd ee) **
1140 +(% style="color:#037691" %)**​​​​​​​**(%%)**AT+SETCNT=aa,(bb cc dd ee) **
1170 1170  
1171 1171  aa: 1: Set count1,
1172 1172