Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -867,10 +867,7 @@ 867 867 868 868 * (% style="color:#037691" %)AT Command: 869 869 870 -(% class="box infomessage" %) 871 -((( 872 872 **AT+TRIG1=a,b** 873 -))) 874 874 875 875 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 876 876 ... ... @@ -882,12 +882,9 @@ 882 882 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 883 883 884 884 885 -* (% style="color:#037691" %)Downlink Payload (prefix 0x09 01 ): 882 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 883 +* **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 886 886 887 -(% class="box infomessage" %) 888 -((( 889 -**0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 890 -))) 891 891 892 892 893 893 ... ... @@ -912,7 +912,7 @@ 912 912 913 913 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):** 914 914 915 -**0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc) **909 +**0x09 02 aa bb cc **~/~/ same as AT+TRIG1=aa,0x(bb cc) 916 916 917 917 918 918