Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,7 +1,6 @@ 1 1 (% style="text-align:center" %) 2 2 [[image:image-20220523163353-1.jpeg||height="604" width="500"]] 3 3 4 -**LT-22222-L LoRa IO Controller User Manual ** 5 5 6 6 7 7 **Table of Contents:** ... ... @@ -16,13 +16,16 @@ 16 16 17 17 = 1.Introduction = 18 18 18 + 19 19 == 1.1 What is LT Series I/O Controller == 20 20 21 21 ((( 22 22 23 23 24 +((( 24 24 The Dragino (% style="color:blue" %)**LT series I/O Modules**(%%) are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (% style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %), **relay output**, **digital input**(%%) and (% style="color:blue" %)**digital output**(%%) etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring. 25 25 ))) 27 +))) 26 26 27 27 ((( 28 28 The LT I/O Controllers allows the user to send data and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, smartphone detection, building automation, and so on. ... ... @@ -37,11 +37,13 @@ 37 37 ))) 38 38 39 39 ((( 40 -1) If user ’s area has LoRaWAN service coverage, they can just install the I/O controller and configure it to connect the LoRaWAN provider via wireless.42 +1) If user's area has LoRaWAN service coverage, they can just install the I/O controller and configure it to connect the LoRaWAN provider via wireless. 41 41 ))) 42 42 43 43 ((( 44 44 2) User can set up a LoRaWAN gateway locally and configure the controller to connect to the gateway via wireless. 47 + 48 + 45 45 ))) 46 46 47 47 ((( ... ... @@ -56,7 +56,7 @@ 56 56 ((( 57 57 58 58 59 -**Hardware System:** 63 +(% style="color:#037691" %)**Hardware System:** 60 60 ))) 61 61 62 62 * ((( ... ... @@ -81,7 +81,7 @@ 81 81 ((( 82 82 83 83 84 -**Interface for Model: LT22222-L:** 88 +(% style="color:#037691" %)**Interface for Model: LT22222-L:** 85 85 ))) 86 86 87 87 * ((( ... ... @@ -106,7 +106,7 @@ 106 106 ((( 107 107 108 108 109 -**LoRa Spec:** 113 +(% style="color:#037691" %)**LoRa Spec:** 110 110 ))) 111 111 112 112 * ((( ... ... @@ -173,9 +173,10 @@ 173 173 174 174 == 1.3 Features == 175 175 180 + 176 176 * LoRaWAN Class A & Class C protocol 177 177 * Optional Customized LoRa Protocol 178 -* Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865 183 +* Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865/MA869 179 179 * AT Commands to change parameters 180 180 * Remote configure parameters via LoRa Downlink 181 181 * Firmware upgradable via program port ... ... @@ -185,6 +185,7 @@ 185 185 186 186 == 1.4 Applications == 187 187 193 + 188 188 * Smart Buildings & Home Automation 189 189 * Logistics and Supply Chain Management 190 190 * Smart Metering ... ... @@ -196,6 +196,7 @@ 196 196 197 197 == 1.5 Hardware Variants == 198 198 205 + 199 199 (% border="1" style="background-color:#f7faff; width:500px" %) 200 200 |(% style="width:103px" %)**Model**|(% style="width:131px" %)**Photo**|(% style="width:334px" %)**Description** 201 201 |(% style="width:103px" %)**LT22222-L**|(% style="width:131px" %)[[image:1653296302983-697.png]]|(% style="width:334px" %)((( ... ... @@ -208,12 +208,18 @@ 208 208 ))) 209 209 210 210 218 + 211 211 = 2. Power ON Device = 212 212 221 + 222 +((( 213 213 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. 224 +))) 214 214 215 215 ((( 216 216 PWR will on when device is properly powered. 228 + 229 + 217 217 ))) 218 218 219 219 [[image:1653297104069-180.png]] ... ... @@ -222,21 +222,27 @@ 222 222 223 223 = 3. Operation Mode = 224 224 238 + 225 225 == 3.1 How it works? == 226 226 241 + 227 227 ((( 228 -The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on **TX LED** will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. **TX LED** will be on for 5 seconds after joined in network. When there is message from server, the **RX LED**will be on for 1 second.243 +The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%) will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. (% style="color:green" %)**TX LED**(%%) will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second. 229 229 ))) 230 230 231 231 ((( 232 -In case user can ’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.247 +In case user can't set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 233 233 ))) 234 234 235 235 251 + 236 236 == 3.2 Example to join LoRaWAN network == 237 237 254 + 238 238 ((( 239 239 This chapter shows an example for how to join the TTN LoRaWAN Network. Below is the network structure, we use our LG308 as LoRaWAN gateway here. 257 + 258 + 240 240 ))) 241 241 242 242 [[image:image-20220523172350-1.png||height="266" width="864"]] ... ... @@ -244,6 +244,8 @@ 244 244 245 245 ((( 246 246 The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN: 266 + 267 + 247 247 ))) 248 248 249 249 ((( ... ... @@ -259,18 +259,21 @@ 259 259 260 260 Input these keys in the LoRaWAN Server portal. Below is TTN screen shot: 261 261 262 -Add APP EUI in the application. 283 +**Add APP EUI in the application.** 263 263 264 264 [[image:1653297955910-247.png||height="321" width="716"]] 265 265 266 266 267 -Add APP KEY and DEV EUI 288 +**Add APP KEY and DEV EUI** 268 268 269 269 [[image:1653298023685-319.png]] 270 270 271 271 293 + 272 272 ((( 273 273 (% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 296 + 297 + 274 274 ))) 275 275 276 276 [[image:1653298044601-602.png||height="405" width="709"]] ... ... @@ -279,20 +279,24 @@ 279 279 280 280 == 3.3 Uplink Payload == 281 281 306 + 282 282 There are five working modes + one interrupt mode on LT for different type application: 283 283 284 -* **MOD1**: (default setting): 2 x ACI + 2AVI + DI + DO + RO 285 -* **MOD2**: Double DI Counting + DO + RO 286 -* **MOD3**: Single DI Counting + 2 x ACI + DO + RO 287 -* **MOD4**: Single DI Counting + 1 x Voltage Counting + DO + RO 288 -* **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 289 -* **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 309 +* (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO 310 +* (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO 311 +* (% style="color:blue" %)**MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO 312 +* (% style="color:blue" %)**MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO 313 +* (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 314 +* (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5 290 290 291 291 292 292 293 293 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 294 294 320 + 321 +((( 295 295 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. 323 +))) 296 296 297 297 [[image:image-20220523174024-3.png]] 298 298 ... ... @@ -308,7 +308,7 @@ 308 308 * DI is for digital input. DIx=1: high or float, DIx=0: low. 309 309 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 310 310 311 -(% style="color:red" %)Note: DI3 and DO3 bit are not valid for LT-22222-L 339 +(% style="color:red" %)**Note: DI3 and DO3 bit are not valid for LT-22222-L** 312 312 313 313 For example if payload is: [[image:image-20220523175847-2.png]] 314 314 ... ... @@ -348,7 +348,9 @@ 348 348 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 349 349 350 350 379 +((( 351 351 **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins. 381 +))) 352 352 353 353 ((( 354 354 Total : 11 bytes payload ... ... @@ -368,7 +368,7 @@ 368 368 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 369 369 370 370 ((( 371 -(% style="color:red" %)Note: DO3 bit is not valid for LT-22222-L. 401 +(% style="color:red" %)**Note: DO3 bit is not valid for LT-22222-L.** 372 372 ))) 373 373 374 374 ((( ... ... @@ -380,48 +380,53 @@ 380 380 (% class="box infomessage" %) 381 381 ((( 382 382 ((( 413 +((( 383 383 **AT+MOD=2** 415 +))) 384 384 417 +((( 385 385 **ATZ** 386 386 ))) 387 387 ))) 421 +))) 388 388 389 389 ((( 390 390 391 391 392 392 (% style="color:#4f81bd" %)**AT Commands for counting:** 427 + 428 + 393 393 ))) 394 394 395 395 ((( 396 396 **For LT22222-L:** 397 -))) 398 398 399 -(% class="box infomessage" %) 400 -((( 401 -((( 402 -**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 403 403 404 -**AT+TRIG1= 1,100(set DI1 port to trigger onhighlevel, valid signal is 100ms435 +(% style="color:blue" %)**AT+TRIG1=0,100**(%%)** (set DI1 port to trigger on low level, valid signal is 100ms) ** 405 405 406 -**AT+TRIG 2=0,100 (set DI2port to trigger onlowlevel, valid signal is 100ms) **437 +(% style="color:blue" %)**AT+TRIG1=1,100**(%%)** (set DI1 port to trigger on high level, valid signal is 100ms ) ** 407 407 408 -**AT+TRIG2= 1,100 (set DI2 port to trigger onhighlevel, valid signal is 100ms439 +(% style="color:blue" %)**AT+TRIG2=0,100**(%%)** (set DI2 port to trigger on low level, valid signal is 100ms) ** 409 409 410 -**AT+ SETCNT=1,60SetCOUNT1valueto60)**441 +(% style="color:blue" %)**AT+TRIG2=1,100**(%%)** (set DI2 port to trigger on high level, valid signal is 100ms ) ** 411 411 412 -**AT+SETCNT=2,60 (Set COUNT2 value to 60)** 443 +(% style="color:blue" %)**AT+SETCNT=1,60**(%%)** (Set COUNT1 value to 60)** 444 + 445 +(% style="color:blue" %)**AT+SETCNT=2,60**(%%)** (Set COUNT2 value to 60)** 413 413 ))) 414 -))) 415 415 416 416 417 417 418 418 === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI === 419 419 452 + 420 420 **LT22222-L**: This mode the DI1 is used as a counting pin. 421 421 422 422 [[image:image-20220523181246-5.png]] 423 423 424 424 ((( 458 + 459 + 425 425 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 426 426 ))) 427 427 ... ... @@ -432,9 +432,10 @@ 432 432 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 433 433 434 434 ((( 435 -(% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 470 +(% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.** 436 436 ))) 437 437 473 + 438 438 ((( 439 439 **To use counting mode, please run:** 440 440 ))) ... ... @@ -442,11 +442,15 @@ 442 442 (% class="box infomessage" %) 443 443 ((( 444 444 ((( 481 +((( 445 445 **AT+MOD=3** 483 +))) 446 446 485 +((( 447 447 **ATZ** 448 448 ))) 449 449 ))) 489 +))) 450 450 451 451 ((( 452 452 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. ... ... @@ -457,9 +457,13 @@ 457 457 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 458 458 459 459 500 +((( 460 460 **LT22222-L**: This mode the DI1 is used as a counting pin. 502 +))) 461 461 504 +((( 462 462 The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour. 506 +))) 463 463 464 464 [[image:image-20220523181903-8.png]] 465 465 ... ... @@ -475,7 +475,7 @@ 475 475 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 476 476 477 477 ((( 478 -(% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 522 +(% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.** 479 479 ))) 480 480 481 481 ((( ... ... @@ -487,14 +487,17 @@ 487 487 (% class="box infomessage" %) 488 488 ((( 489 489 ((( 534 +((( 490 490 **AT+MOD=4** 536 +))) 491 491 538 +((( 492 492 **ATZ** 493 493 ))) 494 494 ))) 542 +))) 495 495 496 496 497 - 498 498 ((( 499 499 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 500 500 ))) ... ... @@ -503,22 +503,19 @@ 503 503 504 504 505 505 **Plus below command for AVI1 Counting:** 506 -))) 507 507 508 -(% class="box infomessage" %) 509 -((( 510 -((( 511 -(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 512 512 513 -(% style="color:blue" %)**AT+ VOLMAX=20000**(%%)**(IfAVI1voltagehigherthanVOLMAX(20000mV=20v), counterincrease1)**555 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 514 514 515 -(% style="color:blue" %)**AT+VOLMAX=20000 ,0**(%%)**lower than VOLMAX (20000mV =20v), counter increase 1)**557 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 516 516 517 -(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 559 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 560 + 561 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 518 518 ))) 519 -))) 520 520 521 521 565 + 522 522 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 523 523 524 524 ... ... @@ -539,7 +539,7 @@ 539 539 ))) 540 540 541 541 ((( 542 -(% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 586 +(% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.** 543 543 ))) 544 544 545 545 ((( ... ... @@ -551,11 +551,15 @@ 551 551 (% class="box infomessage" %) 552 552 ((( 553 553 ((( 598 +((( 554 554 **AT+MOD=5** 600 +))) 555 555 602 +((( 556 556 **ATZ** 557 557 ))) 558 558 ))) 606 +))) 559 559 560 560 ((( 561 561 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. ... ... @@ -570,8 +570,8 @@ 570 570 571 571 For example, if user has configured below commands: 572 572 573 -* **AT+MOD=1 ** **~-~->** The normal working mode 574 -* **AT+ADDMOD6=1** **~-~->** Enable trigger 621 +* **AT+MOD=1 ** **~-~->** The normal working mode 622 +* **AT+ADDMOD6=1** **~-~->** Enable trigger 575 575 576 576 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 577 577 ... ... @@ -580,10 +580,12 @@ 580 580 581 581 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 582 582 631 + 583 583 (% style="color:#4f81bd" %)**Trigger base on voltage**: 584 584 585 585 Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH> 586 586 636 + 587 587 **Example:** 588 588 589 589 AT+AVLIM=3000,6000,0,2000 (If AVI1 voltage lower than 3v or higher than 6v. or AV2 voltage is higher than 2v, LT will trigger Uplink) ... ... @@ -596,6 +596,7 @@ 596 596 597 597 Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH> 598 598 649 + 599 599 **Example:** 600 600 601 601 AT+ACLIM=10000,15000,0,0 (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink) ... ... @@ -614,6 +614,7 @@ 614 614 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 615 615 616 616 668 + 617 617 (% style="color:#037691" %)**Downlink Command to set Trigger Condition:** 618 618 619 619 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** ... ... @@ -662,6 +662,7 @@ 662 662 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW 663 663 664 664 717 + 665 665 (% style="color:#4f81bd" %)**TRI Status1**(%%) is a combination to show which condition is trigger. Totally 1byte as below 666 666 667 667 [[image:image-20220524090249-3.png]] ... ... @@ -673,6 +673,7 @@ 673 673 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. 674 674 675 675 729 + 676 676 (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below 677 677 678 678 [[image:image-20220524090456-4.png]] ... ... @@ -686,6 +686,7 @@ 686 686 00000101: Means both DI1 and DI2 trigger are enabled. 687 687 688 688 743 + 689 689 (% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable. 0x00: MOD6 is disable. 690 690 691 691 Downlink command to poll MOD6 status: ... ... @@ -701,19 +701,23 @@ 701 701 ((( 702 702 703 703 704 -**Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]] 705 - 706 - 759 +**Decoder for TTN/loraserver/ChirpStack**: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]] 707 707 ))) 708 708 709 709 763 + 710 710 == 3.4 Configure LT via AT or Downlink == 711 711 766 + 767 +((( 712 712 User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands 769 +))) 713 713 714 714 ((( 772 +((( 715 715 There are two kinds of Commands: 716 716 ))) 775 +))) 717 717 718 718 * (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 719 719 ... ... @@ -721,88 +721,85 @@ 721 721 722 722 723 723 783 + 724 724 === 3.4.1 Common Commands === 725 725 786 + 787 +((( 726 726 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 789 +))) 727 727 728 728 729 729 730 730 === 3.4.2 Sensor related commands === 731 731 795 + 732 732 ==== 3.4.2.1 Set Transmit Interval ==== 733 733 798 + 734 734 Set device uplink interval. 735 735 736 736 * (% style="color:#037691" %)**AT Command:** 737 737 738 -(% class="box infomessage" %) 739 -((( 740 740 **AT+TDC=N ** 741 -))) 742 742 805 + 743 743 **Example: **AT+TDC=30000. Means set interval to 30 seconds 744 744 745 745 746 746 * (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 747 747 748 -(% class="box infomessage" %) 749 -((( 750 750 **0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 751 -))) 752 752 753 753 754 754 815 + 755 755 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 756 756 818 + 757 757 Set work mode. 758 758 759 759 * (% style="color:#037691" %)**AT Command:** 760 760 761 -(% class="box infomessage" %) 762 -((( 763 763 **AT+MOD=N ** 764 -))) 765 765 825 + 766 766 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 767 767 768 768 769 769 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 770 770 771 -(% class="box infomessage" %) 772 -((( 773 -**0x0A aa ~/~/ Same as AT+MOD=aa** 774 -))) 831 +**0x0A aa ** ~/~/ Same as AT+MOD=aa 775 775 776 776 777 777 835 + 778 778 ==== 3.4.2.3 Poll an uplink ==== 779 779 780 -* (% style="color:#037691" %)AT Command: 781 781 839 +* (% style="color:#037691" %)**AT Command:** 840 + 782 782 There is no AT Command to poll uplink 783 783 784 784 785 -* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 844 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x08):** 786 786 787 -(% class="box infomessage" %) 788 -((( 789 -**0x08 FF ~/~/ Poll an uplink,** 790 -))) 846 +**0x08 FF **~/~/ Poll an uplink 791 791 848 + 792 792 **Example**: 0x08FF, ask device to send an Uplink 793 793 794 794 795 795 853 + 796 796 ==== 3.4.2.4 Enable Trigger Mode ==== 797 797 856 + 798 798 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 799 799 800 -* (% style="color:#037691" %)AT Command: 859 +* (% style="color:#037691" %)**AT Command:** 801 801 802 -(% class="box infomessage" %) 803 -((( 804 804 **AT+ADDMOD6=1 or 0** 805 -))) 806 806 807 807 1: Enable Trigger Mode 808 808 ... ... @@ -809,43 +809,38 @@ 809 809 0: Disable Trigger Mode 810 810 811 811 812 -* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 868 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):** 813 813 814 -(% class="box infomessage" %) 815 -((( 816 -**0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 817 -))) 870 +**0x0A 06 aa ** ~/~/ Same as AT+ADDMOD6=aa 818 818 819 819 820 820 874 + 821 821 ==== 3.4.2.5 Poll trigger settings ==== 822 822 877 + 823 823 Poll trigger settings, 824 824 825 -* (% style="color:#037691" %)AT Command: 880 +* (% style="color:#037691" %)**AT Command:** 826 826 827 827 There is no AT Command for this feature. 828 828 829 829 830 -* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 885 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):** 831 831 832 -(% class="box infomessage" %) 833 -((( 834 -**0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 835 -))) 887 +**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 836 836 837 837 838 838 891 + 839 839 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 840 840 894 + 841 841 Enable Disable DI1/DI2/DI2 as trigger, 842 842 843 -* (% style="color:#037691" %)AT Command: 897 +* (% style="color:#037691" %)**AT Command:** 844 844 845 -(% class="box infomessage" %) 846 -((( 847 847 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 848 -))) 849 849 850 850 851 851 **Example:** ... ... @@ -852,25 +852,21 @@ 852 852 853 853 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 854 854 855 -* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 906 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):** 856 856 857 -(% class="box infomessage" %) 858 -((( 859 -**0xAA 02 aa bb ~/~/ Same as AT+DTRI=aa,bb** 860 -))) 908 +**0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 861 861 862 862 863 863 912 + 864 864 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 865 865 915 + 866 866 Set DI1 or DI3(for LT-33222-L) trigger. 867 867 868 -* (% style="color:#037691" %)AT Command: 918 +* (% style="color:#037691" %)**AT Command:** 869 869 870 -(% class="box infomessage" %) 871 -((( 872 872 **AT+TRIG1=a,b** 873 -))) 874 874 875 875 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 876 876 ... ... @@ -882,17 +882,12 @@ 882 882 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 883 883 884 884 885 -* (% style="color:#037691" %)Downlink Payload (prefix 0x09 01 ): 932 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 933 +* **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 886 886 887 -(% class="box infomessage" %) 888 -((( 889 -**0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 890 -))) 891 - 892 - 893 - 894 894 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 895 895 937 + 896 896 Set DI2 trigger. 897 897 898 898 * (% style="color:#037691" %)**AT Command:** ... ... @@ -912,7 +912,7 @@ 912 912 913 913 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):** 914 914 915 -**0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc) **957 +**0x09 02 aa bb cc **~/~/ same as AT+TRIG1=aa,0x(bb cc) 916 916 917 917 918 918 ... ... @@ -919,6 +919,7 @@ 919 919 920 920 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 921 921 964 + 922 922 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 923 923 924 924 * (% style="color:#037691" %)**AT Command** ... ... @@ -928,7 +928,7 @@ 928 928 929 929 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )** 930 930 931 -**0x AA 01 aa bb cc dd ee ff gg hh 974 +**0x AA 01 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 932 932 933 933 934 934 ... ... @@ -935,6 +935,7 @@ 935 935 936 936 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 937 937 981 + 938 938 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 939 939 940 940 * (% style="color:#037691" %)**AT Command** ... ... @@ -944,7 +944,7 @@ 944 944 945 945 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )** 946 946 947 -**0x AA 00 aa bb cc dd ee ff gg hh 991 +**0x AA 00 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 948 948 949 949 950 950 ... ... @@ -951,22 +951,30 @@ 951 951 952 952 ==== 3.4.2.11 Trigger – Set minimum interval ==== 953 953 954 -Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 955 955 999 +Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger. 1000 + 956 956 * (% style="color:#037691" %)**AT Command** 957 957 958 -**AT+ATDC=5 .Device won’t response the second trigger within 5 minute after the first trigger.**1003 +**AT+ATDC=5 ** Device won't response the second trigger within 5 minute after the first trigger. 959 959 960 960 961 961 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** 962 962 963 -**0x AC aa bb 1008 +**0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 964 964 1010 +((( 1011 + 965 965 1013 +(% style="color:red" %)**Note: ATDC setting must be more than 5min** 1014 +))) 966 966 967 967 1017 + 1018 + 968 968 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 969 969 1021 + 970 970 * (% style="color:#037691" %)**AT Command** 971 971 972 972 There is no AT Command to control Digital Output ... ... @@ -975,7 +975,6 @@ 975 975 * (% style="color:#037691" %)**Downlink Payload (prefix 0x02)** 976 976 * **0x02 aa bb cc **~/~/ Set DO1/DO2/DO3 output 977 977 978 - 979 979 ((( 980 980 If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low. 981 981 ))) ... ... @@ -987,11 +987,11 @@ 987 987 [[image:image-20220524092754-5.png]] 988 988 989 989 ((( 990 -(% style="color:red" %)Note: For LT-22222-L, there is no DO3, the last byte can use any value. 1041 +(% style="color:red" %)**Note: For LT-22222-L, there is no DO3, the last byte can use any value.** 991 991 ))) 992 992 993 993 ((( 994 -(% style="color:red" %)Device will upload a packet if downlink code executes successfully. 1045 +(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** 995 995 ))) 996 996 997 997 ... ... @@ -999,6 +999,7 @@ 999 999 1000 1000 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1001 1001 1053 + 1002 1002 * (% style="color:#037691" %)**AT Command** 1003 1003 1004 1004 There is no AT Command to control Digital Output ... ... @@ -1035,11 +1035,11 @@ 1035 1035 [[image:image-20220524093351-8.png]] 1036 1036 1037 1037 1038 -(% style="color:#4f81bd" %)**Sixth and Seventh Byte**: 1090 +(% style="color:#4f81bd" %)**Sixth and Seventh and Eighth and Ninth Byte**: 1039 1039 1040 1040 Latching time. Unit: ms 1041 1041 1042 -Device will upload a packet if downlink code executes successfully. 1094 +(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** 1043 1043 1044 1044 1045 1045 **Example payload:** ... ... @@ -1065,6 +1065,7 @@ 1065 1065 1066 1066 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1067 1067 1120 + 1068 1068 * (% style="color:#037691" %)**AT Command:** 1069 1069 1070 1070 There is no AT Command to control Relay Output ... ... @@ -1087,7 +1087,7 @@ 1087 1087 [[image:image-20220524093724-9.png]] 1088 1088 ))) 1089 1089 1090 -Device will upload a packet if downlink code executes successfully. 1143 +(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** 1091 1091 1092 1092 1093 1093 ... ... @@ -1094,6 +1094,7 @@ 1094 1094 1095 1095 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1096 1096 1150 + 1097 1097 * (% style="color:#037691" %)**AT Command:** 1098 1098 1099 1099 There is no AT Command to control Relay Output ... ... @@ -1117,42 +1117,42 @@ 1117 1117 1118 1118 (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status: 1119 1119 1120 -[[image:image-20220 524093831-10.png]]1174 +[[image:image-20221008095908-1.png||height="364" width="564"]] 1121 1121 1122 1122 1123 -(% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms 1177 +(% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh Bytes(cc)**(%%): Latching time. Unit: ms 1124 1124 1125 -Device will upload a packet if downlink code executes successfully. 1179 +(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** 1126 1126 1127 1127 1128 1128 **Example payload:** 1129 1129 1130 -**~1. 05 01 11 07 D 0**1184 +**~1. 05 01 11 07 D** 1131 1131 1132 -Relay1 and Relay 2 will be set to N O, last 2 seconds, then change back to original state.1186 +Relay1 and Relay 2 will be set to NC , last 2 seconds, then change back to original state. 1133 1133 1134 1134 **2. 05 01 10 07 D0** 1135 1135 1136 -Relay1 will change to N O, Relay2 will change to NC, last 2 seconds, then both change back to original state.1190 +Relay1 will change to NC, Relay2 will change to NO, last 2 seconds, then both change back to original state. 1137 1137 1138 1138 **3. 05 00 01 07 D0** 1139 1139 1140 -Relay1 will change to N C, Relay2 will change to NO, last 2 seconds, then relay change to NO,C.1194 +Relay1 will change to NO, Relay2 will change to NC, last 2 seconds, then relay change to NC,Relay2 change to NO. 1141 1141 1142 1142 **4. 05 00 00 07 D0** 1143 1143 1144 -Relay 1 & relay2 will change to N C, last 2 seconds, then both change to NO.1198 +Relay 1 & relay2 will change to NO, last 2 seconds, then both change to NC. 1145 1145 1146 1146 1147 1147 1148 - 1149 1149 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1150 1150 1204 + 1151 1151 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1152 1152 1153 1153 * (% style="color:#037691" %)**AT Command:** 1154 1154 1155 - (% style="color:#037691" %)****(%%)**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]1209 +**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1156 1156 1157 1157 1158 1158 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** ... ... @@ -1164,9 +1164,10 @@ 1164 1164 1165 1165 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1166 1166 1221 + 1167 1167 * (% style="color:#037691" %)**AT Command:** 1168 1168 1169 - (% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) **1224 +**AT+SETCNT=aa,(bb cc dd ee) ** 1170 1170 1171 1171 aa: 1: Set count1, 1172 1172 ... ... @@ -1186,11 +1186,12 @@ 1186 1186 1187 1187 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1188 1188 1244 + 1189 1189 Clear counting for counting mode 1190 1190 1191 1191 * (% style="color:#037691" %)**AT Command:** 1192 1192 1193 - (% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting1249 +**AT+CLRCOUNT ** ~/~/ clear all counting 1194 1194 1195 1195 1196 1196 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** ... ... @@ -1202,6 +1202,7 @@ 1202 1202 1203 1203 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1204 1204 1261 + 1205 1205 * (% style="color:#037691" %)**AT Command:** 1206 1206 1207 1207 **AT+COUTIME=60 **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30) ... ... @@ -1214,13 +1214,127 @@ 1214 1214 ((( 1215 1215 range: aa bb cc:0 to 16777215, (unit:second) 1216 1216 1274 + 1275 + 1217 1217 1218 1218 ))) 1219 1219 1279 +==== 3.4.2.20 Reset save DR DO state ==== 1220 1220 1221 1221 1282 +* (% style="color:#037691" %)**AT Command:** 1283 + 1284 +**AT+RODORET=1 **~/~/ RODO will close when the device joining the network. (default) 1285 + 1286 +**AT+RODORET=0 **~/~/After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state is not changed when it is reconnected to the network. 1287 + 1288 + 1289 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAD):** 1290 + 1291 +**0x AD aa **~/~/ same as AT+RODORET =aa 1292 + 1293 +((( 1294 + 1295 + 1296 + 1297 + 1298 +==== 3.4.2.21 Encrypted payload ==== 1299 + 1300 + 1301 +* (% style="color:#037691" %)**AT Command:** 1302 + 1303 +**AT+DECRYPT=1 **~/~/ The payload is uploaded without encryption 1304 + 1305 +**AT+DECRYPT=0 **~/~/Encrypt when uploading payload (default) 1306 + 1307 + 1308 + 1309 + 1310 +==== 3.4.2.22 Get sensor value ==== 1311 + 1312 + 1313 +* (% style="color:#037691" %)**AT Command:** 1314 + 1315 +**AT+GETSENSORVALUE=0 **~/~/ The serial port gets the reading of the current sensor 1316 + 1317 +**AT+GETSENSORVALUE=1 **~/~/The serial port gets the current sensor reading and uploads it. 1318 + 1319 + 1320 + 1321 + 1322 +==== 3.4.2.23 Resets the downlink packet count ==== 1323 + 1324 + 1325 +* (% style="color:#037691" %)**AT Command:** 1326 + 1327 +**AT+DISFCNTCHECK=0 **~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node will no longer receive downlink packets (default) 1328 + 1329 +**AT+DISFCNTCHECK=1 **~/~/When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node resets the downlink packet count and keeps it consistent with the server downlink packet count. 1330 + 1331 + 1332 + 1333 + 1334 +==== 3.4.2.24 When the limit bytes are exceeded, upload in batches ==== 1335 + 1336 + 1337 +* (% style="color:#037691" %)**AT Command:** 1338 + 1339 + **AT+DISMACANS=0** ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of 11 bytes (DR0 of US915, DR2 of AS923, DR2 of AU195), the node will send a packet with a payload of 00 and a port of 4. (default) 1340 + 1341 + **AT+DISMACANS=1** ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of the DR, the node will ignore the MACANS and not reply, and only upload the payload part. 1342 + 1343 + 1344 +* (% style="color:#037691" %)**Downlink Payload **(%%)**:** 1345 + 1346 +**0x21 00 01 ** ~/~/ Set the DISMACANS=1 1347 + 1348 + 1349 + 1350 + 1351 +==== 3.4.2.25 Copy downlink to uplink ==== 1352 + 1353 + 1354 +* (% style="color:#037691" %)**AT Command**(%%)**:** 1355 + 1356 + **AT+RPL=5** ~/~/ After receiving the package from the server, it will immediately upload the content of the package to the server, the port number is 100. 1357 + 1358 +Example:**aa xx xx xx xx** ~/~/ aa indicates whether the configuration has changed, 00 is yes, 01 is no; xx xx xx xx are the bytes sent. 1359 + 1360 + 1361 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173747-6.png?width=1124&height=165&rev=1.1||alt="image-20220823173747-6.png"]] 1362 + 1363 +For example, sending 11 22 33 44 55 66 77 will return invalid configuration 00 11 22 33 44 55 66 77. 1364 + 1365 + 1366 + 1367 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173833-7.png?width=1124&height=149&rev=1.1||alt="image-20220823173833-7.png"]] 1368 + 1369 +For example, if 01 00 02 58 is issued, a valid configuration of 01 01 00 02 58 will be returned. 1370 + 1371 + 1372 + 1373 +==== 3.4.2.26 Query version number and frequency band 、TDC ==== 1374 + 1375 + 1376 +* ((( 1377 +(% style="color:#037691" %)**Downlink Payload**(%%)**:** 1378 + 1379 +**26 01 ** ~/~/ Downlink 26 01 can query device upload frequency, frequency band, software version number, TDC time. 1380 + 1381 + 1382 +))) 1383 + 1384 +**Example:** 1385 + 1386 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173929-8.png?width=1205&height=76&rev=1.1||alt="image-20220823173929-8.png"]] 1387 + 1388 + 1389 + 1390 +))) 1391 + 1222 1222 == 3.5 Integrate with Mydevice == 1223 1223 1394 + 1224 1224 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: 1225 1225 1226 1226 ((( ... ... @@ -1229,14 +1229,15 @@ 1229 1229 1230 1230 ((( 1231 1231 (% style="color:blue" %)**Step 2**(%%): To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps: 1403 + 1404 + 1232 1232 ))) 1233 1233 1234 -[[image:1 653356737703-362.png||height="232" width="732"]]1407 +[[image:image-20220719105525-1.png||height="377" width="677"]] 1235 1235 1236 -[[image:image-20220524094641-11.png||height="390" width="723"]] 1237 1237 1238 1238 1239 -[[image:image-20220 524094641-12.png||height="402" width="718"]]1411 +[[image:image-20220719110247-2.png||height="388" width="683"]] 1240 1240 1241 1241 1242 1242 (% style="color:blue" %)**Step 3**(%%): Create an account or log in Mydevices. ... ... @@ -1269,8 +1269,10 @@ 1269 1269 1270 1270 == 3.6 Interface Detail == 1271 1271 1444 + 1272 1272 === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) === 1273 1273 1447 + 1274 1274 Support NPN Type sensor 1275 1275 1276 1276 [[image:1653356991268-289.png]] ... ... @@ -1279,6 +1279,7 @@ 1279 1279 1280 1280 === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) === 1281 1281 1456 + 1282 1282 ((( 1283 1283 The DI port of LT-22222-L can support NPN or PNP output sensor. 1284 1284 ))) ... ... @@ -1285,7 +1285,9 @@ 1285 1285 1286 1286 ((( 1287 1287 ((( 1288 -Internal circuit as below, the NEC2501 is a photocoupler, the Active current (from NEC2501 pin 1 to pin 2 is 1ma and the max current is 50mA. When there is active current pass NEC2501 pin1 to pin2. The DI will be active high 1463 +Internal circuit as below, the NEC2501 is a photocoupler, the Active current (from NEC2501 pin 1 to pin 2 is 1ma and the max current is 50mA. When there is active current pass NEC2501 pin1 to pin2. The DI will be active high. 1464 + 1465 + 1289 1289 ))) 1290 1290 ))) 1291 1291 ... ... @@ -1310,10 +1310,10 @@ 1310 1310 ))) 1311 1311 1312 1312 * ((( 1313 -Connect sensor ’s output to DI1-1490 +Connect sensor's output to DI1- 1314 1314 ))) 1315 1315 * ((( 1316 -Connect sensor ’s VCC to DI1+.1493 +Connect sensor's VCC to DI1+. 1317 1317 ))) 1318 1318 1319 1319 ((( ... ... @@ -1321,15 +1321,17 @@ 1321 1321 ))) 1322 1322 1323 1323 ((( 1324 -[[image:1653968155772-850.png||height="23" width="19"]]**= DI1+ 1501 +[[image:1653968155772-850.png||height="23" width="19"]]**= DI1**+** / 1K.** 1325 1325 ))) 1326 1326 1327 1327 ((( 1328 -If 1505 +If** DI1+ **= **12v**, the [[image:1653968155772-850.png||height="23" width="19"]]= 12mA , So the LT-22222-L will be able to detect this active signal. 1329 1329 ))) 1330 1330 1331 1331 ((( 1332 1332 1510 + 1511 + 1333 1333 ))) 1334 1334 1335 1335 ((( ... ... @@ -1341,10 +1341,10 @@ 1341 1341 ))) 1342 1342 1343 1343 * ((( 1344 -Connect sensor ’s output to DI1+1523 +Connect sensor's output to DI1+ 1345 1345 ))) 1346 1346 * ((( 1347 -Connect sensor ’s GND DI1-.1526 +Connect sensor's GND DI1-. 1348 1348 ))) 1349 1349 1350 1350 ((( ... ... @@ -1361,6 +1361,8 @@ 1361 1361 1362 1362 ((( 1363 1363 1543 + 1544 + 1364 1364 ))) 1365 1365 1366 1366 ((( ... ... @@ -1372,10 +1372,10 @@ 1372 1372 ))) 1373 1373 1374 1374 * ((( 1375 -Connect sensor ’s output to DI1+ with a serial 50K resistor1556 +Connect sensor's output to DI1+ with a serial 50K resistor 1376 1376 ))) 1377 1377 * ((( 1378 -Connect sensor ’s GND DI1-.1559 +Connect sensor's GND DI1-. 1379 1379 ))) 1380 1380 1381 1381 ((( ... ... @@ -1394,6 +1394,7 @@ 1394 1394 1395 1395 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1396 1396 1578 + 1397 1397 NPN output: GND or Float. Max voltage can apply to output pin is 36v. 1398 1398 1399 1399 [[image:1653357531600-905.png]] ... ... @@ -1402,6 +1402,7 @@ 1402 1402 1403 1403 === 3.6.4 Analog Input Interface === 1404 1404 1587 + 1405 1405 The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is: 1406 1406 1407 1407 ... ... @@ -1414,13 +1414,13 @@ 1414 1414 We take the wind speed sensor as an example for reference only. 1415 1415 1416 1416 1417 -**Specifications of the wind speed sensor:** 1600 +(% style="color:blue" %)**Specifications of the wind speed sensor:** 1418 1418 1419 -Red: 12~~24v 1602 +**Red: 12~~24v** 1420 1420 1421 -Yellow: 4~~20mA 1604 +**Yellow: 4~~20mA** 1422 1422 1423 -Black: GND 1606 +**Black: GND** 1424 1424 1425 1425 1426 1426 **Connection diagram:** ... ... @@ -1433,6 +1433,7 @@ 1433 1433 1434 1434 === 3.6.5 Relay Output === 1435 1435 1619 + 1436 1436 ((( 1437 1437 The LT serial controller has two relay interfaces; each interface uses two pins of the screw terminal. User can connect other device’s Power Line to in serial of RO1_1 and RO_2. Such as below: 1438 1438 ))) ... ... @@ -1439,6 +1439,7 @@ 1439 1439 1440 1440 [[image:image-20220524100215-9.png]] 1441 1441 1626 + 1442 1442 [[image:image-20220524100215-10.png||height="382" width="723"]] 1443 1443 1444 1444 ... ... @@ -1445,15 +1445,25 @@ 1445 1445 1446 1446 == 3.7 LEDs Indicators == 1447 1447 1633 + 1448 1448 [[image:image-20220524100748-11.png]] 1449 1449 1450 1450 1637 + 1451 1451 = 4. Use AT Command = 1452 1452 1640 + 1453 1453 == 4.1 Access AT Command == 1454 1454 1643 + 1644 +((( 1455 1455 LT supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to LT for using AT command, as below. 1646 +))) 1456 1456 1648 +((( 1649 + 1650 +))) 1651 + 1457 1457 [[image:1653358238933-385.png]] 1458 1458 1459 1459 ... ... @@ -1481,7 +1481,7 @@ 1481 1481 ))) 1482 1482 1483 1483 ((( 1484 -AT+<CMD>=? : Get the value 1679 +AT+<CMD>=? : Get the value 1485 1485 ))) 1486 1486 1487 1487 ((( ... ... @@ -1509,11 +1509,11 @@ 1509 1509 ))) 1510 1510 1511 1511 ((( 1512 -AT+APPSKEY: Get or Set the Application Session Key 1707 +AT+APPSKEY: Get or Set the Application Session Key 1513 1513 ))) 1514 1514 1515 1515 ((( 1516 -AT+APPEUI: Get or Set the Application EUI 1711 +AT+APPEUI: Get or Set the Application EUI 1517 1517 ))) 1518 1518 1519 1519 ((( ... ... @@ -1525,7 +1525,7 @@ 1525 1525 ))) 1526 1526 1527 1527 ((( 1528 -AT+DR: Get or Set the Data Rate. (0-7 corresponding to DR_X) 1723 +AT+DR: Get or Set the Data Rate. (0-7 corresponding to DR_X) 1529 1529 ))) 1530 1530 1531 1531 ((( ... ... @@ -1561,7 +1561,7 @@ 1561 1561 ))) 1562 1562 1563 1563 ((( 1564 -AT+NJM: Get or Set the Network Join Mode. (0: ABP, 1: OTAA) 1759 +AT+NJM: Get or Set the Network Join Mode. (0: ABP, 1: OTAA) 1565 1565 ))) 1566 1566 1567 1567 ((( ... ... @@ -1605,7 +1605,7 @@ 1605 1605 ))) 1606 1606 1607 1607 ((( 1608 -AT+VER: Get current image version and Frequency Band 1803 +AT+VER: Get current image version and Frequency Band 1609 1609 ))) 1610 1610 1611 1611 ((( ... ... @@ -1613,7 +1613,7 @@ 1613 1613 ))) 1614 1614 1615 1615 ((( 1616 -AT+CFS: Get confirmation status of the last AT+SEND (0-1) 1811 +AT+CFS: Get confirmation status of the last AT+SEND (0-1) 1617 1617 ))) 1618 1618 1619 1619 ((( ... ... @@ -1650,8 +1650,6 @@ 1650 1650 1651 1651 ((( 1652 1652 AT+CFG: Print all settings 1653 - 1654 - 1655 1655 ))) 1656 1656 1657 1657 ... ... @@ -1658,47 +1658,48 @@ 1658 1658 1659 1659 == 4.2 Common AT Command Sequence == 1660 1660 1854 + 1661 1661 === 4.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1662 1662 1663 1663 ((( 1664 1664 1665 1665 1666 -**If device has not joined network yet:** 1860 +((( 1861 +(% style="color:blue" %)**If device has not joined network yet:** 1667 1667 ))) 1863 +))) 1668 1668 1669 1669 ((( 1670 -(% style="background-color:#dcdcdc" %)123456 1866 +(% style="background-color:#dcdcdc" %)**123456** 1671 1671 ))) 1672 1672 1673 1673 ((( 1674 -(% style="background-color:#dcdcdc" %)AT+FDR 1870 +(% style="background-color:#dcdcdc" %)**AT+FDR** 1675 1675 ))) 1676 1676 1677 1677 ((( 1678 -(% style="background-color:#dcdcdc" %)123456 1874 +(% style="background-color:#dcdcdc" %)**123456** 1679 1679 ))) 1680 1680 1681 1681 ((( 1682 -(% style="background-color:#dcdcdc" %)AT+NJM=0 1878 +(% style="background-color:#dcdcdc" %)**AT+NJM=0** 1683 1683 ))) 1684 1684 1685 1685 ((( 1686 -(% style="background-color:#dcdcdc" %)ATZ 1882 +(% style="background-color:#dcdcdc" %)**ATZ** 1687 1687 ))) 1688 1688 1689 1689 1690 1690 ((( 1691 -**If device already joined network:** 1887 +(% style="color:blue" %)**If device already joined network:** 1692 1692 ))) 1693 1693 1694 1694 ((( 1695 -(% style="background-color:#dcdcdc" %)AT+NJM=0 1891 +(% style="background-color:#dcdcdc" %)**AT+NJM=0** 1696 1696 ))) 1697 1697 1698 1698 ((( 1699 -(% style="background-color:#dcdcdc" %)ATZ 1700 - 1701 - 1895 +(% style="background-color:#dcdcdc" %)**ATZ** 1702 1702 ))) 1703 1703 1704 1704 ... ... @@ -1708,55 +1708,57 @@ 1708 1708 ((( 1709 1709 1710 1710 1711 -(% style="background-color:#dcdcdc" %)123456(%%) Enter Password to have AT access. 1905 +((( 1906 +(% style="background-color:#dcdcdc" %)**123456**(%%) ~/~/ Enter Password to have AT access. 1712 1712 ))) 1908 +))) 1713 1713 1714 1714 ((( 1715 -(% style="background-color:#dcdcdc" %) AT+FDR(%%) 1911 +(% style="background-color:#dcdcdc" %)** AT+FDR**(%%) ~/~/ Reset Parameters to Factory Default, Keys Reserve 1716 1716 ))) 1717 1717 1718 1718 ((( 1719 -(% style="background-color:#dcdcdc" %) 123456(%%) Enter Password to have AT access. 1915 +(% style="background-color:#dcdcdc" %)** 123456**(%%) ~/~/ Enter Password to have AT access. 1720 1720 ))) 1721 1721 1722 1722 ((( 1723 -(% style="background-color:#dcdcdc" %) AT+CLASS=C(%%) Set to work in CLASS C 1919 +(% style="background-color:#dcdcdc" %)** AT+CLASS=C**(%%) ~/~/ Set to work in CLASS C 1724 1724 ))) 1725 1725 1726 1726 ((( 1727 -(% style="background-color:#dcdcdc" %) AT+NJM=0(%%) Set to ABP mode 1923 +(% style="background-color:#dcdcdc" %)** AT+NJM=0**(%%) ~/~/ Set to ABP mode 1728 1728 ))) 1729 1729 1730 1730 ((( 1731 -(% style="background-color:#dcdcdc" %) AT+ADR=0(%%) Set the Adaptive Data Rate Off 1927 +(% style="background-color:#dcdcdc" %) **AT+ADR=0**(%%) ~/~/ Set the Adaptive Data Rate Off 1732 1732 ))) 1733 1733 1734 1734 ((( 1735 -(% style="background-color:#dcdcdc" %) AT+DR=5(%%) Set Data Rate 1931 +(% style="background-color:#dcdcdc" %)** AT+DR=5**(%%) ~/~/ Set Data Rate 1736 1736 ))) 1737 1737 1738 1738 ((( 1739 -(% style="background-color:#dcdcdc" %) AT+TDC=60000(%%) Set transmit interval to 60 seconds 1935 +(% style="background-color:#dcdcdc" %)** AT+TDC=60000**(%%) ~/~/ Set transmit interval to 60 seconds 1740 1740 ))) 1741 1741 1742 1742 ((( 1743 -(% style="background-color:#dcdcdc" %) AT+CHS=868400000(%%) Set transmit frequency to 868.4Mhz 1939 +(% style="background-color:#dcdcdc" %)** AT+CHS=868400000**(%%) ~/~/ Set transmit frequency to 868.4Mhz 1744 1744 ))) 1745 1745 1746 1746 ((( 1747 -(% style="background-color:#dcdcdc" %) AT+RX2FQ=868400000(%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 1943 +(% style="background-color:#dcdcdc" %)** AT+RX2FQ=868400000**(%%) ~/~/ Set RX2Frequency to 868.4Mhz (according to the result from server) 1748 1748 ))) 1749 1749 1750 1750 ((( 1751 -(% style="background-color:#dcdcdc" %) AT+RX2DR=5(%%) 1947 +(% style="background-color:#dcdcdc" %)** AT+RX2DR=5**(%%)** ** ~/~/ Set RX2DR to match the downlink DR from server. see below 1752 1752 ))) 1753 1753 1754 1754 ((( 1755 -(% style="background-color:#dcdcdc" %) AT+DADDR=26 01 1A F1 (%%) Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1951 +(% style="background-color:#dcdcdc" %)** AT+DADDR=26 01 1A F1** (%%) ~/~/ Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1756 1756 ))) 1757 1757 1758 1758 ((( 1759 -(% style="background-color:#dcdcdc" %) ATZ (%%) Reset MCU 1955 +(% style="background-color:#dcdcdc" %)** ATZ** (%%) ~/~/ Reset MCU 1760 1760 1761 1761 1762 1762 ))) ... ... @@ -1766,10 +1766,16 @@ 1766 1766 ))) 1767 1767 1768 1768 ((( 1769 -(% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server. 1770 -2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1771 -3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1772 -4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1965 +**~1. Make sure the device is set to ABP mode in the IoT Server.** 1966 + 1967 +**2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.** 1968 + 1969 +**3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php? 1970 +dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.** 1971 + 1972 +**4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5** 1973 + 1974 + 1773 1773 ))) 1774 1774 1775 1775 ((( ... ... @@ -1783,13 +1783,19 @@ 1783 1783 1784 1784 === 4.2.3 Change to Class A === 1785 1785 1786 -If sensor JOINED 1787 -(% style="background-color:#dcdcdc" %)AT+CLASS=A 1788 -ATZ 1789 1789 1989 +((( 1990 +(% style="color:blue" %)If sensor JOINED: 1790 1790 1992 +(% style="background-color:#dcdcdc" %)**AT+CLASS=A 1993 +ATZ** 1994 +))) 1995 + 1996 + 1997 + 1791 1791 = 5. FAQ = 1792 1792 2000 + 1793 1793 == 5.1 How to upgrade the image? == 1794 1794 1795 1795 ... ... @@ -1806,14 +1806,18 @@ 1806 1806 1807 1807 ((( 1808 1808 (% style="color:blue" %)**Step1**(%%)**:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1809 -(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:http://www.dr agino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].2017 +(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:https://www.dropbox.com/sh/g99v0fxcltn9r1y/AADKXQ2v5ZT-S3sxdmbvE7UAa/LT-22222-L/image?dl=0&subfolder_nav_tracking=1]]. 1810 1810 (% style="color:blue" %)**Step3**(%%)**:** Open flashloader; choose the correct COM port to update. 1811 1811 1812 1812 2021 +((( 1813 1813 (% style="color:blue" %)**For LT-22222-L**(%%): 1814 -Hold down the PRO button and then momentarily press the RST reset button and the **DO1 led** will change from OFF to ON. When **DO1 LED** is on, it means the device is in download mode. 2023 +Hold down the PRO button and then momentarily press the RST reset button and the (% style="color:red" %)**DO1 led**(%%) will change from OFF to ON. When (% style="color:red" %)**DO1 LED**(%%) is on, it means the device is in download mode. 1815 1815 ))) 1816 1816 2026 + 2027 +))) 2028 + 1817 1817 [[image:image-20220524103407-12.png]] 1818 1818 1819 1819 [[image:image-20220524103429-13.png]] ... ... @@ -1823,6 +1823,7 @@ 1823 1823 1824 1824 (% style="color:red" %)**Notice**(%%): In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is: 1825 1825 2038 + 1826 1826 [[image:1653360054704-518.png||height="186" width="745"]] 1827 1827 1828 1828 ... ... @@ -1831,6 +1831,8 @@ 1831 1831 1832 1832 1833 1833 == 5.2 How to change the LoRa Frequency Bands/Region? == 2047 + 2048 + 1834 1834 ))) 1835 1835 ))) 1836 1836 ... ... @@ -1841,7 +1841,10 @@ 1841 1841 ((( 1842 1842 1843 1843 2059 + 1844 1844 == 5.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? == 2061 + 2062 + 1845 1845 ))) 1846 1846 1847 1847 ((( ... ... @@ -1854,38 +1854,45 @@ 1854 1854 ((( 1855 1855 Assume we have a LG02 working in the frequency 868400000 now , below is the step. 1856 1856 2075 + 1857 1857 1858 1858 ))) 1859 1859 ))) 1860 1860 1861 1861 ((( 1862 -(% style="color:#4f81bd" %)**Step1**(%%): Log in TTN, Create an ABP device in the application and input the network session key (NETSKEY), app session key (APPSKEY) from the device. 2081 +(% style="color:blue" %)**Step1**(%%): Log in TTN, Create an ABP device in the application and input the network session key (NETSKEY), app session key (APPSKEY) from the device. 2082 + 2083 + 1863 1863 ))) 1864 1864 1865 1865 ((( 1866 1866 [[image:1653360231087-571.png||height="401" width="727"]] 2088 + 2089 + 1867 1867 ))) 1868 1868 1869 1869 ((( 1870 -(% style="color:red" %)Note: user just need to make sure above three keys match, User can change either in TTN or Device to make then match. In TTN, NETSKEY and APPSKEY can be configured by user in setting page, but Device Addr is generated by TTN. 2093 +(% style="color:red" %)**Note: user just need to make sure above three keys match, User can change either in TTN or Device to make then match. In TTN, NETSKEY and APPSKEY can be configured by user in setting page, but Device Addr is generated by TTN.** 1871 1871 ))) 1872 1872 1873 1873 2097 + 1874 1874 ((( 1875 -(% style="color:#4f81bd" %)**Step2**(%%)**: **Run AT Command to make LT work in Single frequency & ABP mode. Below is the AT commands: 2099 +(% style="color:blue" %)**Step2**(%%)**: **Run AT Command to make LT work in Single frequency & ABP mode. Below is the AT commands: 2100 + 2101 + 1876 1876 ))) 1877 1877 1878 1878 ((( 1879 -(% style="background-color:#dcdcdc" %)123456 (%%) Enter Password to have AT access. 1880 -(% style="background-color:#dcdcdc" %)AT+FDR(%%) Reset Parameters to Factory Default, Keys Reserve 1881 -(% style="background-color:#dcdcdc" %)123456 (%%) Enter Password to have AT access. 1882 -(% style="background-color:#dcdcdc" %)AT+NJM=0 (%%) Set to ABP mode 1883 -(% style="background-color:#dcdcdc" %)AT+ADR=0 (%%) Set the Adaptive Data Rate Off 1884 -(% style="background-color:#dcdcdc" %)AT+DR=5 (%%) Set Data Rate (Set AT+DR=3 for 915 band) 1885 -(% style="background-color:#dcdcdc" %)AT+TDC=60000 (%%) Set transmit interval to 60 seconds 1886 -(% style="background-color:#dcdcdc" %)AT+CHS=868400000(%%) Set transmit frequency to 868.4Mhz 1887 -(% style="background-color:#dcdcdc" %)AT+DADDR=26 01 1A F1(%%) Set Device Address to 26 01 1A F1 1888 -(% style="background-color:#dcdcdc" %)ATZ (%%) Reset MCU 2105 +(% style="background-color:#dcdcdc" %)**123456** (%%) : Enter Password to have AT access. 2106 +(% style="background-color:#dcdcdc" %)**AT+FDR**(%%) : Reset Parameters to Factory Default, Keys Reserve 2107 +(% style="background-color:#dcdcdc" %)**AT+NJM=0** (%%) : Set to ABP mode 2108 +(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%) : Set the Adaptive Data Rate Off 2109 +(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%) : Set Data Rate (Set AT+DR=3 for 915 band) 2110 +(% style="background-color:#dcdcdc" %)**AT+TDC=60000 **(%%) : Set transmit interval to 60 seconds 2111 +(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) : Set transmit frequency to 868.4Mhz 2112 +(% style="background-color:#dcdcdc" %)**AT+DADDR=26 01 1A F1**(%%) : Set Device Address to 26 01 1A F1 2113 +(% style="background-color:#dcdcdc" %)**ATZ** (%%) : Reset MCU 1889 1889 ))) 1890 1890 1891 1891 ... ... @@ -1896,20 +1896,28 @@ 1896 1896 [[image:1653360498588-932.png||height="485" width="726"]] 1897 1897 1898 1898 2124 + 1899 1899 == 5.4 Can I see counting event in Serial? == 1900 1900 2127 + 1901 1901 ((( 1902 -User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn ’t support AT+DEBUG. User can update to latest firmware first.2129 +User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn't support AT+DEBUG. User can update to latest firmware first. 1903 1903 1904 1904 2132 + 1905 1905 == 5.5 Can i use point to point communication for LT-22222-L? == 1906 1906 2135 + 1907 1907 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 2137 + 2138 + 2139 + 1908 1908 ))) 1909 1909 1910 1910 ((( 1911 1911 == 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? == 1912 1912 2145 + 1913 1913 If the device is not shut down, but directly powered off. 1914 1914 1915 1915 It will default that this is a power-off state. ... ... @@ -1918,12 +1918,28 @@ 1918 1918 1919 1919 After restart, the status before power failure will be read from flash. 1920 1920 2154 + 2155 + 2156 +== 5.7 Can i set up LT-22222-L as a NC(Normal Close) Relay? == 2157 + 2158 + 2159 +LT-22222-L built-in relay is NO (Normal Open). User can use an external relay to achieve Normal Close purpose. Diagram as below: 2160 + 2161 + 2162 +[[image:image-20221006170630-1.png||height="610" width="945"]] 2163 + 2164 + 2165 + 1921 1921 = 6. Trouble Shooting = 2167 + 2168 + 1922 1922 ))) 1923 1923 1924 1924 ((( 1925 1925 ((( 1926 -== 6.1 Downlink doesn’t work, how to solve it? == 2173 +== 6.1 Downlink doesn't work, how to solve it? == 2174 + 2175 + 1927 1927 ))) 1928 1928 ))) 1929 1929 ... ... @@ -1934,7 +1934,10 @@ 1934 1934 ((( 1935 1935 1936 1936 2186 + 1937 1937 == 6.2 Have trouble to upload image. == 2188 + 2189 + 1938 1938 ))) 1939 1939 1940 1940 ((( ... ... @@ -1944,7 +1944,10 @@ 1944 1944 ((( 1945 1945 1946 1946 1947 -== 6.3 Why I can’t join TTN in US915 /AU915 bands? == 2199 + 2200 +== 6.3 Why I can't join TTN in US915 /AU915 bands? == 2201 + 2202 + 1948 1948 ))) 1949 1949 1950 1950 ((( ... ... @@ -1958,19 +1958,20 @@ 1958 1958 1959 1959 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1960 1960 1961 - 1962 1962 (% style="color:#4f81bd" %)**XXX:** 1963 1963 1964 -* (% style="color: #4f81bd" %)**EU433**(%%): LT with frequency bands EU4331965 -* (% style="color: #4f81bd" %)**EU868**(%%): LT with frequency bands EU8681966 -* (% style="color: #4f81bd" %)**KR920**(%%): LT with frequency bands KR9201967 -* (% style="color: #4f81bd" %)**CN470**(%%): LT with frequency bands CN4701968 -* (% style="color: #4f81bd" %)**AS923**(%%): LT with frequency bands AS9231969 -* (% style="color: #4f81bd" %)**AU915**(%%): LT with frequency bands AU9151970 -* (% style="color: #4f81bd" %)**US915**(%%): LT with frequency bands US9151971 -* (% style="color: #4f81bd" %)**IN865**(%%): LT with frequency bands IN8651972 -* (% style="color: #4f81bd" %)**CN779**(%%): LT with frequency bands CN7792218 +* (% style="color:red" %)**EU433**(%%): LT with frequency bands EU433 2219 +* (% style="color:red" %)**EU868**(%%): LT with frequency bands EU868 2220 +* (% style="color:red" %)**KR920**(%%): LT with frequency bands KR920 2221 +* (% style="color:red" %)**CN470**(%%): LT with frequency bands CN470 2222 +* (% style="color:red" %)**AS923**(%%): LT with frequency bands AS923 2223 +* (% style="color:red" %)**AU915**(%%): LT with frequency bands AU915 2224 +* (% style="color:red" %)**US915**(%%): LT with frequency bands US915 2225 +* (% style="color:red" %)**IN865**(%%): LT with frequency bands IN865 2226 +* (% style="color:red" %)**CN779**(%%): LT with frequency bands CN779 1973 1973 2228 + 2229 + 1974 1974 = 8. Packing Info = 1975 1975 1976 1976 ... ... @@ -1988,18 +1988,25 @@ 1988 1988 * Package Size / pcs : 14.5 x 8 x 5 cm 1989 1989 * Weight / pcs : 170g 1990 1990 2247 + 2248 + 1991 1991 = 9. Support = 1992 1992 2251 + 1993 1993 * ((( 1994 1994 Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1995 1995 ))) 1996 1996 * ((( 1997 1997 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 2257 + 2258 + 2259 + 2260 + 1998 1998 ))) 1999 1999 2000 2000 = 10. Reference = 2001 2001 2265 + 2002 2002 * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] 2003 -* [[Image Download>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]] 2004 -* [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 2267 +* [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]] 2005 2005 * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]]
- image-20220714135731-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +54.1 KB - Content
- image-20220719105525-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +165.5 KB - Content
- image-20220719110247-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +52.9 KB - Content
- image-20221006170630-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +486.5 KB - Content
- image-20221008095908-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +41.8 KB - Content