Last modified by Mengting Qiu on 2025/06/04 18:42

From version 82.17
edited by Xiaoling
on 2022/06/20 11:51
Change comment: There is no comment for this version
To version 82.23
edited by Xiaoling
on 2022/06/20 11:58
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -182,7 +182,6 @@
182 182  * Counting
183 183  
184 184  
185 -
186 186  == 1.4  Applications ==
187 187  
188 188  * Smart Buildings & Home Automation
... ... @@ -193,7 +193,6 @@
193 193  * Smart Factory
194 194  
195 195  
196 -
197 197  == 1.5 Hardware Variants ==
198 198  
199 199  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -208,6 +208,8 @@
208 208  )))
209 209  
210 210  
209 +
210 +
211 211  = 2. Power ON Device =
212 212  
213 213  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -289,7 +289,6 @@
289 289  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
290 290  
291 291  
292 -
293 293  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
294 294  
295 295  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -344,7 +344,6 @@
344 344  ** DO1 LED is off in both case
345 345  
346 346  
347 -
348 348  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
349 349  
350 350  
... ... @@ -399,13 +399,13 @@
399 399  (% class="box infomessage" %)
400 400  (((
401 401  (((
402 -**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) **
400 +**AT+TRIG1=0,100  (set DI1 port to trigger on low level, valid signal is 100ms) **
403 403  
404 -**AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) **
402 +**AT+TRIG1=1,100  (set DI1 port to trigger on high level, valid signal is 100ms ) **
405 405  
406 -**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) **
404 +**AT+TRIG2=0,100  (set DI2 port to trigger on low level, valid signal is 100ms) **
407 407  
408 -**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) **
406 +**AT+TRIG2=1,100  (set DI2 port to trigger on high level, valid signal is 100ms ) **
409 409  
410 410  **AT+SETCNT=1,60   (Set COUNT1 value to 60)**
411 411  
... ... @@ -508,13 +508,13 @@
508 508  (% class="box infomessage" %)
509 509  (((
510 510  (((
511 -(% style="color:blue" %)**AT+SETCNT=3,60**(%%)**   (set AVI Count to 60)**
509 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)**  (set AVI Count to 60)**
512 512  
513 -(% style="color:blue" %)**AT+VOLMAX=20000**(%%)**   (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)**
511 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)**  (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)**
514 514  
515 -(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)**   (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)**
513 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)**  (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)**
516 516  
517 -(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)**   (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)**
515 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)**  (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)**
518 518  )))
519 519  )))
520 520  
... ... @@ -720,7 +720,6 @@
720 720  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
721 721  
722 722  
723 -
724 724  === 3.4.1 Common Commands ===
725 725  
726 726  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -842,10 +842,7 @@
842 842  
843 843  * (% style="color:#037691" %)AT Command:
844 844  
845 -(% class="box infomessage" %)
846 -(((
847 847  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
848 -)))
849 849  
850 850  
851 851  **Example:**
... ... @@ -854,13 +854,11 @@
854 854  
855 855  * (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02):
856 856  
857 -(% class="box infomessage" %)
858 -(((
859 -**0xAA 02 aa bb  ~/~/ Same as AT+DTRI=aa,bb**
860 -)))
851 +**0xAA 02 aa bb        **~/~/ Same as AT+DTRI=aa,bb
861 861  
862 862  
863 863  
855 +
864 864  ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ====
865 865  
866 866  Set DI1 or DI3(for LT-33222-L) trigger.
... ... @@ -867,10 +867,7 @@
867 867  
868 868  * (% style="color:#037691" %)AT Command:
869 869  
870 -(% class="box infomessage" %)
871 -(((
872 872  **AT+TRIG1=a,b**
873 -)))
874 874  
875 875  a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1).
876 876  
... ... @@ -882,26 +882,20 @@
882 882  AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms )
883 883  
884 884  
885 -* (% style="color:#037691" %)Downlink Payload (prefix 0x09 01 ):
874 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):**
875 +* **0x09 01 aa bb cc    ** ~/~/ same as AT+TRIG1=aa,0x(bb cc)
886 886  
887 -(% class="box infomessage" %)
888 -(((
889 -**0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)**
890 -)))
891 891  
892 892  
893 -
894 894  ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
895 895  
896 896  Set DI2 trigger.
897 897  
898 -* (% style="color:#037691" %)AT Command:
883 +* (% style="color:#037691" %)**AT Command:**
899 899  
900 -(% class="box infomessage" %)
901 -(((
902 902  **AT+TRIG2=a,b**
903 -)))
904 904  
887 +
905 905  a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1).
906 906  
907 907  b : delay timing.
... ... @@ -912,27 +912,25 @@
912 912  AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms )
913 913  
914 914  
915 -* (% style="color:#037691" %)Downlink Payload (prefix 0x09 02 ):
898 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):**
916 916  
917 -(% class="box infomessage" %)
918 -(((
919 -**0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)**
920 -)))
900 +**0x09 02 aa bb cc           **~/~/ same as AT+TRIG1=aa,0x(bb cc)
921 921  
922 922  
923 923  
904 +
924 924  ==== 3.4.2.9 Trigger – Set AC (current) as trigger ====
925 925  
926 926  Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
927 927  
928 -* (% style="color:#037691" %)AT Command:
909 +* (% style="color:#037691" %)**AT Command**
929 929  
930 930  **AT+ACLIM**
931 931  
932 932  
933 -* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 01 ):
914 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )**
934 934  
935 -**0x AA 01 aa bb cc dd ee ff gg hh  ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
916 +**0x AA 01 aa bb cc dd ee ff gg hh        ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
936 936  
937 937  
938 938  
... ... @@ -941,14 +941,14 @@
941 941  
942 942  Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
943 943  
944 -* (% style="color:#037691" %)**AT Command:**
925 +* (% style="color:#037691" %)**AT Command**
945 945  
946 946  **AT+AVLIM  See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
947 947  
948 948  
949 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 ):**
930 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )**
950 950  
951 -**0x AA 00 aa bb cc dd ee ff gg hh  ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
932 +**0x AA 00 aa bb cc dd ee ff gg hh    ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
952 952  
953 953  
954 954  
... ... @@ -957,14 +957,14 @@
957 957  
958 958  Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger.
959 959  
960 -* (% style="color:#037691" %)**AT Command:**
941 +* (% style="color:#037691" %)**AT Command**
961 961  
962 962  **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.**
963 963  
964 964  
965 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xAC ):**
946 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )**
966 966  
967 -**0x AC aa bb  ** ~/~/ same as AT+ATDC=0x(aa bb)   . Unit (min)
948 +**0x AC aa bb   ** ~/~/ same as AT+ATDC=0x(aa bb)   . Unit (min)
968 968  
969 969  
970 970  
... ... @@ -971,15 +971,14 @@
971 971  
972 972  ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ====
973 973  
974 -* (% style="color:#037691" %)**AT Command:**
955 +* (% style="color:#037691" %)**AT Command**
975 975  
976 976  There is no AT Command to control Digital Output
977 977  
978 978  
979 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x02):**
960 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x02)**
980 980  * **0x02 aa bb cc     **~/~/ Set DO1/DO2/DO3 output
981 981  
982 -
983 983  (((
984 984  If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low.
985 985  )))
... ... @@ -1003,12 +1003,12 @@
1003 1003  
1004 1004  ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ====
1005 1005  
1006 -* (% style="color:#037691" %)**AT Command:**
986 +* (% style="color:#037691" %)**AT Command**
1007 1007  
1008 1008  There is no AT Command to control Digital Output
1009 1009  
1010 1010  
1011 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA9):**
991 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA9)**
1012 1012  
1013 1013  **0xA9 aa bb cc     **~/~/ Set DO1/DO2/DO3 output with time control
1014 1014