Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -927,48 +927,63 @@ 927 927 928 928 * (% style="color:#037691" %)AT Command: 929 929 930 -**AT+ACLIM** 930 +(% class="box infomessage" %) 931 +((( 932 +**AT+ACLIM. ** 933 +))) 931 931 932 932 933 933 * (% style="color:#037691" %)Downlink Payload (prefix 0xAA 01 ): 934 934 935 -**0x AA 01 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 938 +(% class="box infomessage" %) 939 +((( 940 +**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 941 +))) 936 936 937 937 938 938 939 - 940 940 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 941 941 942 942 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 943 943 944 -* (% style="color:#037691" %) **AT Command:**949 +* (% style="color:#037691" %)AT Command: 945 945 946 -**AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 951 +(% class="box infomessage" %) 952 +((( 953 +**AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 954 +))) 947 947 948 948 949 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAA 00 ):**957 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 00 ): 950 950 951 -**0x AA 00 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 959 +(% class="box infomessage" %) 960 +((( 961 +**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ** 962 +))) 952 952 953 953 954 954 955 - 956 956 ==== 3.4.2.11 Trigger – Set minimum interval ==== 957 957 958 958 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 959 959 960 -* (% style="color:#037691" %) **AT Command:**970 +* (% style="color:#037691" %)AT Command: 961 961 972 +(% class="box infomessage" %) 973 +((( 962 962 **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.** 975 +))) 963 963 964 964 965 965 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC ):** 966 966 967 -**0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 980 +(% class="box infomessage" %) 981 +((( 982 +**0x AC aa bb ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min)** 983 +))) 968 968 969 969 970 970 971 - 972 972 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 973 973 974 974 * (% style="color:#037691" %)**AT Command:**