Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Change comment:
Uploaded new attachment "image-20220714135731-1.png", version {1}
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -1,7 +1,6 @@ 1 1 (% style="text-align:center" %) 2 2 [[image:image-20220523163353-1.jpeg||height="604" width="500"]] 3 3 4 -**LT-22222-L LoRa IO Controller User Manual ** 5 5 6 6 7 7 **Table of Contents:** ... ... @@ -167,7 +167,6 @@ 167 167 Packet engine up to 256 bytes with CRC. 168 168 169 169 170 - 171 171 172 172 ))) 173 173 ... ... @@ -181,8 +181,6 @@ 181 181 * Firmware upgradable via program port 182 182 * Counting 183 183 184 - 185 - 186 186 == 1.4 Applications == 187 187 188 188 * Smart Buildings & Home Automation ... ... @@ -192,8 +192,6 @@ 192 192 * Smart Cities 193 193 * Smart Factory 194 194 195 - 196 - 197 197 == 1.5 Hardware Variants == 198 198 199 199 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -207,7 +207,6 @@ 207 207 * 1 x Counting Port 208 208 ))) 209 209 210 - 211 211 = 2. Power ON Device = 212 212 213 213 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -225,11 +225,11 @@ 225 225 == 3.1 How it works? == 226 226 227 227 ((( 228 -The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on **TX LED** will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. **TX LED** will be on for 5 seconds after joined in network. When there is message from server, the **RX LED**will be on for 1 second.221 +The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%) will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. (% style="color:green" %)**TX LED**(%%) will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second. 229 229 ))) 230 230 231 231 ((( 232 -In case user can ’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.225 +In case user can't set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 233 233 ))) 234 234 235 235 ... ... @@ -281,15 +281,13 @@ 281 281 282 282 There are five working modes + one interrupt mode on LT for different type application: 283 283 284 -* **MOD1**: (default setting): 2 x ACI + 2AVI + DI + DO + RO 285 -* **MOD2**: Double DI Counting + DO + RO 286 -* **MOD3**: Single DI Counting + 2 x ACI + DO + RO 287 -* **MOD4**: Single DI Counting + 1 x Voltage Counting + DO + RO 288 -* **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 289 -* **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 277 +* (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO 278 +* (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO 279 +* (% style="color:blue" %)**MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO 280 +* (% style="color:blue" %)**MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO 281 +* (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 282 +* (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5 290 290 291 - 292 - 293 293 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 294 294 295 295 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -343,8 +343,6 @@ 343 343 ** DO1 is high in case there is load between DO1 and V+. 344 344 ** DO1 LED is off in both case 345 345 346 - 347 - 348 348 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 349 349 350 350 ... ... @@ -394,24 +394,20 @@ 394 394 395 395 ((( 396 396 **For LT22222-L:** 397 -))) 398 398 399 -(% class="box infomessage" %) 400 -((( 401 -((( 402 -**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 403 403 404 -**AT+TRIG1= 1,100(set DI1 port to trigger onhighlevel, valid signal is 100ms388 +(% style="color:blue" %)**AT+TRIG1=0,100**(%%)** (set DI1 port to trigger on low level, valid signal is 100ms) ** 405 405 406 -**AT+TRIG 2=0,100 (set DI2port to trigger onlowlevel, valid signal is 100ms) **390 +(% style="color:blue" %)**AT+TRIG1=1,100**(%%)** (set DI1 port to trigger on high level, valid signal is 100ms ) ** 407 407 408 -**AT+TRIG2= 1,100 (set DI2 port to trigger onhighlevel, valid signal is 100ms392 +(% style="color:blue" %)**AT+TRIG2=0,100**(%%)** (set DI2 port to trigger on low level, valid signal is 100ms) ** 409 409 410 -**AT+ SETCNT=1,60SetCOUNT1valueto60)**394 +(% style="color:blue" %)**AT+TRIG2=1,100**(%%)** (set DI2 port to trigger on high level, valid signal is 100ms ) ** 411 411 412 -**AT+SETCNT=2,60 (Set COUNT2 value to 60)** 396 +(% style="color:blue" %)**AT+SETCNT=1,60**(%%)** (Set COUNT1 value to 60)** 397 + 398 +(% style="color:blue" %)**AT+SETCNT=2,60**(%%)** (Set COUNT2 value to 60)** 413 413 ))) 414 -))) 415 415 416 416 417 417 ... ... @@ -422,6 +422,8 @@ 422 422 [[image:image-20220523181246-5.png]] 423 423 424 424 ((( 410 + 411 + 425 425 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 426 426 ))) 427 427 ... ... @@ -435,6 +435,7 @@ 435 435 (% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 436 436 ))) 437 437 425 + 438 438 ((( 439 439 **To use counting mode, please run:** 440 440 ))) ... ... @@ -503,22 +503,19 @@ 503 503 504 504 505 505 **Plus below command for AVI1 Counting:** 506 -))) 507 507 508 -(% class="box infomessage" %) 509 -((( 510 -((( 511 -(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 512 512 513 -(% style="color:blue" %)**AT+ VOLMAX=20000**(%%)**(IfAVI1voltagehigherthanVOLMAX(20000mV=20v), counterincrease1)**496 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 514 514 515 -(% style="color:blue" %)**AT+VOLMAX=20000 ,0**(%%)**lower than VOLMAX (20000mV =20v), counter increase 1)**498 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 516 516 517 -(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 500 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 501 + 502 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 518 518 ))) 519 -))) 520 520 521 521 506 + 522 522 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 523 523 524 524 ... ... @@ -570,8 +570,8 @@ 570 570 571 571 For example, if user has configured below commands: 572 572 573 -* **AT+MOD=1 ** **~-~->** The normal working mode 574 -* **AT+ADDMOD6=1** **~-~->** Enable trigger 558 +* **AT+MOD=1 ** **~-~->** The normal working mode 559 +* **AT+ADDMOD6=1** **~-~->** Enable trigger 575 575 576 576 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 577 577 ... ... @@ -580,6 +580,7 @@ 580 580 581 581 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 582 582 568 + 583 583 (% style="color:#4f81bd" %)**Trigger base on voltage**: 584 584 585 585 Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH> ... ... @@ -719,8 +719,6 @@ 719 719 720 720 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 721 721 722 - 723 - 724 724 === 3.4.1 Common Commands === 725 725 726 726 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -729,6 +729,7 @@ 729 729 730 730 === 3.4.2 Sensor related commands === 731 731 716 + 732 732 ==== 3.4.2.1 Set Transmit Interval ==== 733 733 734 734 Set device uplink interval. ... ... @@ -735,23 +735,19 @@ 735 735 736 736 * (% style="color:#037691" %)**AT Command:** 737 737 738 -(% class="box infomessage" %) 739 -((( 740 740 **AT+TDC=N ** 741 -))) 742 742 725 + 743 743 **Example: **AT+TDC=30000. Means set interval to 30 seconds 744 744 745 745 746 746 * (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 747 747 748 -(% class="box infomessage" %) 749 -((( 750 750 **0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 751 -))) 752 752 753 753 754 754 735 + 755 755 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 756 756 757 757 Set work mode. ... ... @@ -758,51 +758,42 @@ 758 758 759 759 * (% style="color:#037691" %)**AT Command:** 760 760 761 -(% class="box infomessage" %) 762 -((( 763 763 **AT+MOD=N ** 764 -))) 765 765 744 + 766 766 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 767 767 768 768 769 769 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 770 770 771 -(% class="box infomessage" %) 772 -((( 773 -**0x0A aa ~/~/ Same as AT+MOD=aa** 774 -))) 750 +**0x0A aa ** ~/~/ Same as AT+MOD=aa 775 775 776 776 777 777 754 + 778 778 ==== 3.4.2.3 Poll an uplink ==== 779 779 780 -* (% style="color:#037691" %)AT Command: 757 +* (% style="color:#037691" %)**AT Command:** 781 781 782 782 There is no AT Command to poll uplink 783 783 784 784 785 -* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 762 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x08):** 786 786 787 -(% class="box infomessage" %) 788 -((( 789 -**0x08 FF ~/~/ Poll an uplink,** 790 -))) 764 +**0x08 FF **~/~/ Poll an uplink 791 791 792 792 **Example**: 0x08FF, ask device to send an Uplink 793 793 794 794 795 795 770 + 796 796 ==== 3.4.2.4 Enable Trigger Mode ==== 797 797 798 798 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 799 799 800 -* (% style="color:#037691" %)AT Command: 775 +* (% style="color:#037691" %)**AT Command:** 801 801 802 -(% class="box infomessage" %) 803 -((( 804 804 **AT+ADDMOD6=1 or 0** 805 -))) 806 806 807 807 1: Enable Trigger Mode 808 808 ... ... @@ -809,43 +809,36 @@ 809 809 0: Disable Trigger Mode 810 810 811 811 812 -* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 784 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):** 813 813 814 -(% class="box infomessage" %) 815 -((( 816 -**0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 817 -))) 786 +**0x0A 06 aa ** ~/~/ Same as AT+ADDMOD6=aa 818 818 819 819 820 820 790 + 821 821 ==== 3.4.2.5 Poll trigger settings ==== 822 822 823 823 Poll trigger settings, 824 824 825 -* (% style="color:#037691" %)AT Command: 795 +* (% style="color:#037691" %)**AT Command:** 826 826 827 827 There is no AT Command for this feature. 828 828 829 829 830 -* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 800 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):** 831 831 832 -(% class="box infomessage" %) 833 -((( 834 -**0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 835 -))) 802 +**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 836 836 837 837 838 838 806 + 839 839 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 840 840 841 841 Enable Disable DI1/DI2/DI2 as trigger, 842 842 843 -* (% style="color:#037691" %)AT Command: 811 +* (% style="color:#037691" %)**AT Command:** 844 844 845 -(% class="box infomessage" %) 846 -((( 847 847 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 848 -))) 849 849 850 850 851 851 **Example:** ... ... @@ -852,25 +852,20 @@ 852 852 853 853 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 854 854 855 -* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 820 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):** 856 856 857 -(% class="box infomessage" %) 858 -((( 859 -**0xAA 02 aa bb ~/~/ Same as AT+DTRI=aa,bb** 860 -))) 822 +**0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 861 861 862 862 863 863 826 + 864 864 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 865 865 866 866 Set DI1 or DI3(for LT-33222-L) trigger. 867 867 868 -* (% style="color:#037691" %)AT Command: 831 +* (% style="color:#037691" %)**AT Command:** 869 869 870 -(% class="box infomessage" %) 871 -((( 872 872 **AT+TRIG1=a,b** 873 -))) 874 874 875 875 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 876 876 ... ... @@ -882,26 +882,18 @@ 882 882 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 883 883 884 884 885 -* (% style="color:#037691" %)Downlink Payload (prefix 0x09 01 ): 845 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 846 +* **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 886 886 887 -(% class="box infomessage" %) 888 -((( 889 -**0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 890 -))) 891 - 892 - 893 - 894 894 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 895 895 896 896 Set DI2 trigger. 897 897 898 -* (% style="color:#037691" %)AT Command: 852 +* (% style="color:#037691" %)**AT Command:** 899 899 900 -(% class="box infomessage" %) 901 -((( 902 902 **AT+TRIG2=a,b** 903 -))) 904 904 856 + 905 905 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 906 906 907 907 b : delay timing. ... ... @@ -912,93 +912,78 @@ 912 912 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 913 913 914 914 915 -* (% style="color:#037691" %)Downlink Payload (prefix 0x09 02 ): 867 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):** 916 916 917 -(% class="box infomessage" %) 918 -((( 919 -**0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 920 -))) 869 +**0x09 02 aa bb cc **~/~/ same as AT+TRIG1=aa,0x(bb cc) 921 921 922 922 923 923 873 + 924 924 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 925 925 926 926 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 927 927 928 -* (% style="color:#037691" %)AT Command :878 +* (% style="color:#037691" %)**AT Command** 929 929 930 -(% class="box infomessage" %) 931 -((( 932 -**AT+ACLIM. ** 933 -))) 880 +**AT+ACLIM** 934 934 935 935 936 -* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 01 ) :883 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )** 937 937 938 -(% class="box infomessage" %) 939 -((( 940 -**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 941 -))) 885 +**0x AA 01 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 942 942 943 943 944 944 889 + 945 945 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 946 946 947 947 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 948 948 949 -* (% style="color:#037691" %)AT Command :894 +* (% style="color:#037691" %)**AT Command** 950 950 951 -(% class="box infomessage" %) 952 -((( 953 -**AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 954 -))) 896 +**AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 955 955 956 956 957 -* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 00 ) :899 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )** 958 958 959 -(% class="box infomessage" %) 960 -((( 961 -**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ** 962 -))) 901 +**0x AA 00 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 963 963 964 964 965 965 905 + 966 966 ==== 3.4.2.11 Trigger – Set minimum interval ==== 967 967 968 -Set AV and AC trigger minimum interval, system won ’t response to the second trigger within this set time after the first trigger.908 +Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger. 969 969 970 -* (% style="color:#037691" %)AT Command :910 +* (% style="color:#037691" %)**AT Command** 971 971 972 -(% class="box infomessage" %) 973 -((( 974 -**AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.** 975 -))) 912 +**AT+ATDC=5 ** Device won't response the second trigger within 5 minute after the first trigger. 976 976 977 977 978 -* (% style="color:#037691" %)Downlink Payload (prefix 0xAC ) :915 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** 979 979 980 -(% class="box infomessage" %) 917 +**0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 918 + 981 981 ((( 982 -**0x AC aa bb ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min)** 920 + 921 + 922 +(% style="color:red" %)Note: ATDC setting must be more than 5min 983 983 ))) 984 984 985 985 986 986 927 + 987 987 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 988 988 989 -* (% style="color:#037691" %)AT Command :930 +* (% style="color:#037691" %)**AT Command** 990 990 991 991 There is no AT Command to control Digital Output 992 992 993 993 994 -* (% style="color:#037691" %)Downlink Payload (prefix 0x02): 935 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x02)** 936 +* **0x02 aa bb cc **~/~/ Set DO1/DO2/DO3 output 995 995 996 -(% class="box infomessage" %) 997 997 ((( 998 -**0x02 aa bb cc ~/~/ Set DO1/DO2/DO3 output** 999 -))) 1000 - 1001 -((( 1002 1002 If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low. 1003 1003 ))) 1004 1004 ... ... @@ -1018,22 +1018,19 @@ 1018 1018 1019 1019 1020 1020 958 + 1021 1021 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1022 1022 1023 -* (% style="color:#037691" %)AT Command :961 +* (% style="color:#037691" %)**AT Command** 1024 1024 1025 1025 There is no AT Command to control Digital Output 1026 1026 1027 1027 1028 -* (% style="color:#037691" %)Downlink Payload (prefix 0xA9) :966 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA9)** 1029 1029 1030 -(% class="box infomessage" %) 1031 -((( 1032 -((( 1033 -**0xA9 aa bb cc ~/~/ Set DO1/DO2/DO3 output with time control** 1034 -))) 1035 -))) 968 +**0xA9 aa bb cc **~/~/ Set DO1/DO2/DO3 output with time control 1036 1036 970 + 1037 1037 This is to control the digital output time of DO pin. Include four bytes: 1038 1038 1039 1039 (% style="color:#4f81bd" %)**First Byte**(%%)**:** Type code (0xA9) ... ... @@ -1087,20 +1087,19 @@ 1087 1087 1088 1088 1089 1089 1024 + 1090 1090 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1091 1091 1092 -* (% style="color:#037691" %)AT Command: 1027 +* (% style="color:#037691" %)**AT Command:** 1093 1093 1094 1094 There is no AT Command to control Relay Output 1095 1095 1096 1096 1097 -* (% style="color:#037691" %)Downlink Payload (prefix 0x03): 1032 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x03):** 1098 1098 1099 -(% class="box infomessage" %) 1100 -((( 1101 -**0x03 aa bb ~/~/ Set RO1/RO2 output** 1102 -))) 1034 +**0x03 aa bb **~/~/ Set RO1/RO2 output 1103 1103 1036 + 1104 1104 ((( 1105 1105 If payload = 0x030100, it means set RO1 to close and RO2 to open. 1106 1106 ))) ... ... @@ -1117,9 +1117,10 @@ 1117 1117 1118 1118 1119 1119 1053 + 1120 1120 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1121 1121 1122 -* (% style="color:#037691" %)AT Command: 1056 +* (% style="color:#037691" %)**AT Command:** 1123 1123 1124 1124 There is no AT Command to control Relay Output 1125 1125 ... ... @@ -1177,7 +1177,7 @@ 1177 1177 1178 1178 * (% style="color:#037691" %)**AT Command:** 1179 1179 1180 - (% style="color:#037691" %)****(%%)**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]1114 +**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1181 1181 1182 1182 1183 1183 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** ... ... @@ -1191,7 +1191,7 @@ 1191 1191 1192 1192 * (% style="color:#037691" %)**AT Command:** 1193 1193 1194 - (% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) **1128 +**AT+SETCNT=aa,(bb cc dd ee) ** 1195 1195 1196 1196 aa: 1: Set count1, 1197 1197 ... ... @@ -1215,7 +1215,7 @@ 1215 1215 1216 1216 * (% style="color:#037691" %)**AT Command:** 1217 1217 1218 - (% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting1152 +**AT+CLRCOUNT ** ~/~/ clear all counting 1219 1219 1220 1220 1221 1221 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** ... ... @@ -1473,6 +1473,7 @@ 1473 1473 [[image:image-20220524100748-11.png]] 1474 1474 1475 1475 1410 + 1476 1476 = 4. Use AT Command = 1477 1477 1478 1478 == 4.1 Access AT Command == ... ... @@ -1675,8 +1675,6 @@ 1675 1675 1676 1676 ((( 1677 1677 AT+CFG: Print all settings 1678 - 1679 - 1680 1680 ))) 1681 1681 1682 1682 ... ... @@ -1722,8 +1722,6 @@ 1722 1722 1723 1723 ((( 1724 1724 (% style="background-color:#dcdcdc" %)ATZ 1725 - 1726 - 1727 1727 ))) 1728 1728 1729 1729 ... ... @@ -1836,7 +1836,7 @@ 1836 1836 1837 1837 1838 1838 (% style="color:blue" %)**For LT-22222-L**(%%): 1839 -Hold down the PRO button and then momentarily press the RST reset button and the **DO1 led** will change from OFF to ON. When **DO1 LED** is on, it means the device is in download mode. 1770 +Hold down the PRO button and then momentarily press the RST reset button and the (% style="color:red" %)**DO1 led**(%%) will change from OFF to ON. When (% style="color:red" %)**DO1 LED**(%%) is on, it means the device is in download mode. 1840 1840 ))) 1841 1841 1842 1842 [[image:image-20220524103407-12.png]] ... ... @@ -1930,6 +1930,8 @@ 1930 1930 == 5.5 Can i use point to point communication for LT-22222-L? == 1931 1931 1932 1932 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1864 + 1865 + 1933 1933 ))) 1934 1934 1935 1935 ((( ... ... @@ -1943,12 +1943,13 @@ 1943 1943 1944 1944 After restart, the status before power failure will be read from flash. 1945 1945 1879 + 1946 1946 = 6. Trouble Shooting = 1947 1947 ))) 1948 1948 1949 1949 ((( 1950 1950 ((( 1951 -== 6.1 Downlink doesn ’t work, how to solve it? ==1885 +== 6.1 Downlink doesn't work, how to solve it? == 1952 1952 ))) 1953 1953 ))) 1954 1954 ... ... @@ -1969,7 +1969,7 @@ 1969 1969 ((( 1970 1970 1971 1971 1972 -== 6.3 Why I can ’t join TTN in US915 /AU915 bands? ==1906 +== 6.3 Why I can't join TTN in US915 /AU915 bands? == 1973 1973 ))) 1974 1974 1975 1975 ((( ... ... @@ -1977,25 +1977,27 @@ 1977 1977 ))) 1978 1978 1979 1979 1980 - 1981 1981 = 7. Order Info = 1982 1982 1983 1983 1984 1984 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1985 1985 1986 - 1987 1987 (% style="color:#4f81bd" %)**XXX:** 1988 1988 1989 -* (% style="color: #4f81bd" %)**EU433**(%%): LT with frequency bands EU4331990 -* (% style="color: #4f81bd" %)**EU868**(%%): LT with frequency bands EU8681991 -* (% style="color: #4f81bd" %)**KR920**(%%): LT with frequency bands KR9201992 -* (% style="color: #4f81bd" %)**CN470**(%%): LT with frequency bands CN4701993 -* (% style="color: #4f81bd" %)**AS923**(%%): LT with frequency bands AS9231994 -* (% style="color: #4f81bd" %)**AU915**(%%): LT with frequency bands AU9151995 -* (% style="color: #4f81bd" %)**US915**(%%): LT with frequency bands US9151996 -* (% style="color: #4f81bd" %)**IN865**(%%): LT with frequency bands IN8651997 -* (% style="color: #4f81bd" %)**CN779**(%%): LT with frequency bands CN7791921 +* (% style="color:red" %)**EU433**(%%): LT with frequency bands EU433 1922 +* (% style="color:red" %)**EU868**(%%): LT with frequency bands EU868 1923 +* (% style="color:red" %)**KR920**(%%): LT with frequency bands KR920 1924 +* (% style="color:red" %)**CN470**(%%): LT with frequency bands CN470 1925 +* (% style="color:red" %)**AS923**(%%): LT with frequency bands AS923 1926 +* (% style="color:red" %)**AU915**(%%): LT with frequency bands AU915 1927 +* (% style="color:red" %)**US915**(%%): LT with frequency bands US915 1928 +* (% style="color:red" %)**IN865**(%%): LT with frequency bands IN865 1929 +* (% style="color:red" %)**CN779**(%%): LT with frequency bands CN779 1998 1998 1931 + 1932 + 1933 + 1934 + 1999 1999 = 8. Packing Info = 2000 2000 2001 2001 ... ... @@ -2013,6 +2013,10 @@ 2013 2013 * Package Size / pcs : 14.5 x 8 x 5 cm 2014 2014 * Weight / pcs : 170g 2015 2015 1952 + 1953 + 1954 + 1955 + 2016 2016 = 9. Support = 2017 2017 2018 2018 * ((( ... ... @@ -2022,6 +2022,9 @@ 2022 2022 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 2023 2023 ))) 2024 2024 1965 + 1966 + 1967 + 2025 2025 = 10. Reference = 2026 2026 2027 2027 * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]]
- image-20220714135731-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +54.1 KB - Content