... ... @@ -1089,18 +1089,16 @@
1089 1089  
1090 1090  ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1091 1091  
1092 -* (% style="color:#037691" %)AT Command:
1092 +* (% style="color:#037691" %)**AT Command:**
1093 1093  
1094 1094  There is no AT Command to control Relay Output
1095 1095  
1096 1096  
1097 -* (% style="color:#037691" %)Downlink Payload (prefix 0x03):
1097 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x03):**
1098 1098  
1099 -(% class="box infomessage" %)
1100 -(((
1101 -**0x03 aa bb     ~/~/ Set RO1/RO2 output**
1102 -)))
1099 +**0x03 aa bb     **~/~/ Set RO1/RO2 output
1103 1103  
1101 +
1104 1104  (((
1105 1105  If payload = 0x030100, it means set RO1 to close and RO2 to open.
1106 1106  )))
... ... @@ -1117,20 +1117,19 @@
1117 1117  
1118 1118  
1119 1119  
1118 +
1120 1120  ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ====
1121 1121  
1122 -* (% style="color:#037691" %)AT Command:
1121 +* (% style="color:#037691" %)**AT Command:**
1123 1123  
1124 1124  There is no AT Command to control Relay Output
1125 1125  
1126 1126  
1127 -* (% style="color:#037691" %)Downlink Payload (prefix 0x05):
1126 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x05):**
1128 1128  
1129 -(% class="box infomessage" %)
1130 -(((
1131 -**0x05 aa bb cc dd     ~/~/ Set RO1/RO2 relay with time control:**
1132 -)))
1128 +**0x05 aa bb cc dd     **~/~/ Set RO1/RO2 relay with time control
1133 1133  
1130 +
1134 1134  This is to control the relay output time of relay. Include four bytes:
1135 1135  
1136 1136  (% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05)
... ... @@ -1172,6 +1172,7 @@
1172 1172  
1173 1173  
1174 1174  
1172 +
1175 1175  ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ====
1176 1176  
1177 1177  When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
... ... @@ -1187,6 +1187,7 @@
1187 1187  
1188 1188  
1189 1189  
1188 +
1190 1190  ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ====
1191 1191  
1192 1192  * (% style="color:#037691" %)**AT Command:**
... ... @@ -1208,6 +1208,7 @@
1208 1208  
1209 1209  
1210 1210  
1210 +
1211 1211  ==== 3.4.2.18 Counting ~-~- Clear Counting ====
1212 1212  
1213 1213  Clear counting for counting mode
... ... @@ -1223,6 +1223,7 @@
1223 1223  
1224 1224  
1225 1225  
1226 +
1226 1226  ==== 3.4.2.19 Counting ~-~- Change counting mode save time ====
1227 1227  
1228 1228  * (% style="color:#037691" %)**AT Command:**
... ... @@ -1241,6 +1241,7 @@
1241 1241  )))
1242 1242  
1243 1243  
1245 +
1244 1244  == 3.5 Integrate with Mydevice ==
1245 1245  
1246 1246  Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: