... ... @@ -1,7 +1,6 @@
1 1  (% style="text-align:center" %)
2 2  [[image:image-20220523163353-1.jpeg||height="604" width="500"]]
3 3  
4 -**LT-22222-L LoRa IO Controller User Manual **
5 5  
6 6  
7 7  **Table of Contents:**
... ... @@ -16,6 +16,7 @@
16 16  
17 17  = 1.Introduction =
18 18  
18 +
19 19  == 1.1 What is LT Series I/O Controller ==
20 20  
21 21  (((
... ... @@ -37,11 +37,13 @@
37 37  )))
38 38  
39 39  (((
40 -1) If users area has LoRaWAN service coverage, they can just install the I/O controller and configure it to connect the LoRaWAN provider via wireless.
40 +1) If user's area has LoRaWAN service coverage, they can just install the I/O controller and configure it to connect the LoRaWAN provider via wireless.
41 41  )))
42 42  
43 43  (((
44 44  2) User can set up a LoRaWAN gateway locally and configure the controller to connect to the gateway via wireless.
45 +
46 +
45 45  )))
46 46  
47 47  (((
... ... @@ -56,7 +56,7 @@
56 56  (((
57 57  
58 58  
59 -**Hardware System:**
61 +(% style="color:#037691" %)**Hardware System:**
60 60  )))
61 61  
62 62  * (((
... ... @@ -81,7 +81,7 @@
81 81  (((
82 82  
83 83  
84 -**Interface for Model: LT22222-L:**
86 +(% style="color:#037691" %)**Interface for Model: LT22222-L:**
85 85  )))
86 86  
87 87  * (((
... ... @@ -106,7 +106,7 @@
106 106  (((
107 107  
108 108  
109 -**LoRa Spec:**
111 +(% style="color:#037691" %)**LoRa Spec:**
110 110  )))
111 111  
112 112  * (((
... ... @@ -173,9 +173,10 @@
173 173  
174 174  == 1.3 Features ==
175 175  
178 +
176 176  * LoRaWAN Class A & Class C protocol
177 177  * Optional Customized LoRa Protocol
178 -* Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865
181 +* Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865/MA869
179 179  * AT Commands to change parameters
180 180  * Remote configure parameters via LoRa Downlink
181 181  * Firmware upgradable via program port
... ... @@ -183,8 +183,10 @@
183 183  
184 184  
185 185  
189 +
186 186  == 1.4  Applications ==
187 187  
192 +
188 188  * Smart Buildings & Home Automation
189 189  * Logistics and Supply Chain Management
190 190  * Smart Metering
... ... @@ -194,8 +194,10 @@
194 194  
195 195  
196 196  
202 +
197 197  == 1.5 Hardware Variants ==
198 198  
205 +
199 199  (% border="1" style="background-color:#f7faff; width:500px" %)
200 200  |(% style="width:103px" %)**Model**|(% style="width:131px" %)**Photo**|(% style="width:334px" %)**Description**
201 201  |(% style="width:103px" %)**LT22222-L**|(% style="width:131px" %)[[image:1653296302983-697.png]]|(% style="width:334px" %)(((
... ... @@ -208,12 +208,17 @@
208 208  )))
209 209  
210 210  
218 +
219 +
211 211  = 2. Power ON Device =
212 212  
222 +
213 213  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
214 214  
215 215  (((
216 216  PWR will on when device is properly powered.
227 +
228 +
217 217  )))
218 218  
219 219  [[image:1653297104069-180.png]]
... ... @@ -222,21 +222,27 @@
222 222  
223 223  = 3. Operation Mode =
224 224  
237 +
225 225  == 3.1 How it works? ==
226 226  
240 +
227 227  (((
228 -The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on **TX LED** will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. **TX LED** will be on for 5 seconds after joined in network. When there is message from server, the **RX LED** will be on for 1 second. 
242 +The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%) will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. (% style="color:green" %)**TX LED**(%%) will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second. 
229 229  )))
230 230  
231 231  (((
232 -In case user cant set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.
246 +In case user can't set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.
233 233  )))
234 234  
235 235  
250 +
236 236  == 3.2 Example to join LoRaWAN network ==
237 237  
253 +
238 238  (((
239 239  This chapter shows an example for how to join the TTN LoRaWAN Network. Below is the network structure, we use our LG308 as LoRaWAN gateway here. 
256 +
257 +
240 240  )))
241 241  
242 242  [[image:image-20220523172350-1.png||height="266" width="864"]]
... ... @@ -244,6 +244,8 @@
244 244  
245 245  (((
246 246  The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN:
265 +
266 +
247 247  )))
248 248  
249 249  (((
... ... @@ -269,6 +269,7 @@
269 269  [[image:1653298023685-319.png]]
270 270  
271 271  
292 +
272 272  (((
273 273  (% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
274 274  )))
... ... @@ -279,19 +279,22 @@
279 279  
280 280  == 3.3 Uplink Payload ==
281 281  
303 +
282 282  There are five working modes + one interrupt mode on LT for different type application:
283 283  
284 -* **MOD1**: (default setting): 2 x ACI + 2AVI + DI + DO + RO
285 -* **MOD2**: Double DI Counting + DO + RO
286 -* **MOD3**: Single DI Counting + 2 x ACI + DO + RO
287 -* **MOD4**: Single DI Counting + 1 x Voltage Counting + DO + RO
288 -* **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
289 -* **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
306 +* (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO
307 +* (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO
308 +* (% style="color:blue" %)**MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO
309 +* (% style="color:blue" %)**MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO
310 +* (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
311 +* (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
290 290  
291 291  
292 292  
315 +
293 293  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
294 294  
318 +
295 295  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
296 296  
297 297  [[image:image-20220523174024-3.png]]
... ... @@ -308,8 +308,10 @@
308 308  * DI is for digital input. DIx=1: high or float, DIx=0: low.
309 309  * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
310 310  
311 -(% style="color:red" %)Note: DI3 and DO3 bit are not valid for LT-22222-L
312 312  
336 +
337 +(% style="color:red" %)**Note: DI3 and DO3 bit are not valid for LT-22222-L**
338 +
313 313  For example if payload is: [[image:image-20220523175847-2.png]]
314 314  
315 315  
... ... @@ -328,6 +328,8 @@
328 328  * [1] RO1 relay channel is close and the RO1 LED is ON.
329 329  * [0] RO2 relay channel is open and RO2 LED is OFF;
330 330  
357 +
358 +
331 331  **LT22222-L:**
332 332  
333 333  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -345,6 +345,8 @@
345 345  
346 346  
347 347  
376 +
377 +
348 348  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
349 349  
350 350  
... ... @@ -368,7 +368,7 @@
368 368  * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
369 369  
370 370  (((
371 -(% style="color:red" %)Note: DO3 bit is not valid for LT-22222-L.
401 +(% style="color:red" %)**Note: DO3 bit is not valid for LT-22222-L.**
372 372  )))
373 373  
374 374  (((
... ... @@ -390,38 +390,39 @@
390 390  
391 391  
392 392  (% style="color:#4f81bd" %)**AT Commands for counting:**
423 +
424 +
393 393  )))
394 394  
395 395  (((
396 396  **For LT22222-L:**
397 -)))
398 398  
399 -(% class="box infomessage" %)
400 -(((
401 -(((
402 -**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) **
403 403  
404 -**AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) **
431 +(% style="color:blue" %)**AT+TRIG1=0,100**(%%)**  (set DI1 port to trigger on low level, valid signal is 100ms) **
405 405  
406 -**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) **
433 +(% style="color:blue" %)**AT+TRIG1=1,100**(%%)**  (set DI1 port to trigger on high level, valid signal is 100ms ) **
407 407  
408 -**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) **
435 +(% style="color:blue" %)**AT+TRIG2=0,100**(%%)**  (set DI2 port to trigger on low level, valid signal is 100ms) **
409 409  
410 -**AT+SETCNT=1,6  (Set COUNT1 value to 60)**
437 +(% style="color:blue" %)**AT+TRIG2=1,100**(%%)**  (set DI2 port to trigger on high level, valid signal is 100ms ) **
411 411  
412 -**AT+SETCNT=2,60   (Set COUNT2 value to 60)**
439 +(% style="color:blue" %)**AT+SETCNT=1,60**(%%)**   (Set COUNT1 value to 60)**
440 +
441 +(% style="color:blue" %)**AT+SETCNT=2,60**(%%)**   (Set COUNT2 value to 60)**
413 413  )))
414 -)))
415 415  
416 416  
417 417  
418 418  === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI ===
419 419  
448 +
420 420  **LT22222-L**: This mode the DI1 is used as a counting pin.
421 421  
422 422  [[image:image-20220523181246-5.png]]
423 423  
424 424  (((
454 +
455 +
425 425  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
426 426  )))
427 427  
... ... @@ -432,9 +432,10 @@
432 432  * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
433 433  
434 434  (((
435 -(% style="color:red" %)Note: DO3 is not valid for LT-22222-L.
466 +(% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.**
436 436  )))
437 437  
469 +
438 438  (((
439 439  **To use counting mode, please run:**
440 440  )))
... ... @@ -475,7 +475,7 @@
475 475  * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
476 476  
477 477  (((
478 -(% style="color:red" %)Note: DO3 is not valid for LT-22222-L.
510 +(% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.**
479 479  )))
480 480  
481 481  (((
... ... @@ -503,22 +503,19 @@
503 503  
504 504  
505 505  **Plus below command for AVI1 Counting:**
506 -)))
507 507  
508 -(% class="box infomessage" %)
509 -(((
510 -(((
511 -(% style="color:blue" %)**AT+SETCNT=3,60**(%%)**   (set AVI Count to 60)**
512 512  
513 -(% style="color:blue" %)**AT+VOLMAX=20000**(%%)**   (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)**
540 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)**  (set AVI Count to 60)**
514 514  
515 -(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)**   (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)**
542 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)**  (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)**
516 516  
517 -(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)**   (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)**
544 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)**  (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)**
545 +
546 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)**  (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)**
518 518  )))
519 -)))
520 520  
521 521  
550 +
522 522  === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI ===
523 523  
524 524  
... ... @@ -539,7 +539,7 @@
539 539  )))
540 540  
541 541  (((
542 -(% style="color:red" %)Note: DO3 is not valid for LT-22222-L.
571 +(% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.**
543 543  )))
544 544  
545 545  (((
... ... @@ -570,20 +570,27 @@
570 570  
571 571  For example, if user has configured below commands:
572 572  
573 -* **AT+MOD=1 ** **~-~->** The normal working mode
574 -* **AT+ADDMOD6=1**   **~-~->** Enable trigger
602 +* **AT+MOD=1 ** **~-~->**  The normal working mode
603 +* **AT+ADDMOD6=1**   **~-~->**  Enable trigger
575 575  
605 +
606 +
576 576  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
577 577  
578 578  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
579 579  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
580 580  
612 +
613 +
614 +
581 581  (% style="color:#037691" %)**AT Command to set Trigger Condition**:
582 582  
617 +
583 583  (% style="color:#4f81bd" %)**Trigger base on voltage**:
584 584  
585 585  Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH>
586 586  
622 +
587 587  **Example:**
588 588  
589 589  AT+AVLIM=3000,6000,0,2000   (If AVI1 voltage lower than 3v or higher than 6v. or AV2 voltage is higher than 2v, LT will trigger Uplink)
... ... @@ -596,6 +596,7 @@
596 596  
597 597  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
598 598  
635 +
599 599  **Example:**
600 600  
601 601  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
... ... @@ -614,6 +614,7 @@
614 614  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
615 615  
616 616  
654 +
617 617  (% style="color:#037691" %)**Downlink Command to set Trigger Condition:**
618 618  
619 619  Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM**
... ... @@ -657,11 +657,14 @@
657 657  
658 658  * Each bits shows if the corresponding trigger has been configured.
659 659  
698 +
699 +
660 660  **Example:**
661 661  
662 662  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
663 663  
664 664  
705 +
665 665  (% style="color:#4f81bd" %)**TRI Status1**(%%) is a combination to show which condition is trigger. Totally 1byte as below
666 666  
667 667  [[image:image-20220524090249-3.png]]
... ... @@ -668,11 +668,14 @@
668 668  
669 669  * Each bits shows which status has been trigger on this uplink.
670 670  
712 +
713 +
671 671  **Example:**
672 672  
673 673  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
674 674  
675 675  
719 +
676 676  (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below
677 677  
678 678  [[image:image-20220524090456-4.png]]
... ... @@ -679,6 +679,8 @@
679 679  
680 680  * Each bits shows which status has been trigger on this uplink.
681 681  
726 +
727 +
682 682  **Example:**
683 683  
684 684  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -686,6 +686,7 @@
686 686  00000101: Means both DI1 and DI2 trigger are enabled.
687 687  
688 688  
735 +
689 689  (% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable. 0x00: MOD6 is disable.
690 690  
691 691  Downlink command to poll MOD6 status:
... ... @@ -696,19 +696,20 @@
696 696  
697 697  
698 698  
746 +
699 699  === 3.3.7 Payload Decoder ===
700 700  
701 701  (((
702 702  
703 703  
704 -**Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]]
705 -
706 -
752 +**Decoder for TTN/loraserver/ChirpStack**:  [[https:~~/~~/www.dropbox.com/sh/wtrzu7avdtkmn3z/AACK5NwOMkU9jnvf1uCMuqrVa?dl=0>>https://www.dropbox.com/sh/wtrzu7avdtkmn3z/AACK5NwOMkU9jnvf1uCMuqrVa?dl=0]]
707 707  )))
708 708  
709 709  
756 +
710 710  == 3.4 ​Configure LT via AT or Downlink ==
711 711  
759 +
712 712  User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands
713 713  
714 714  (((
... ... @@ -721,8 +721,10 @@
721 721  
722 722  
723 723  
772 +
724 724  === 3.4.1 Common Commands ===
725 725  
775 +
726 726  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
727 727  
728 728  
... ... @@ -729,80 +729,73 @@
729 729  
730 730  === 3.4.2 Sensor related commands ===
731 731  
782 +
732 732  ==== 3.4.2.1 Set Transmit Interval ====
733 733  
785 +
734 734  Set device uplink interval.
735 735  
736 736  * (% style="color:#037691" %)**AT Command:**
737 737  
738 -(% class="box infomessage" %)
739 -(((
740 740  **AT+TDC=N **
741 -)))
742 742  
792 +
743 743  **Example: **AT+TDC=30000. Means set interval to 30 seconds
744 744  
745 745  
746 746  * (% style="color:#037691" %)**Downlink Payload (prefix 0x01):**
747 747  
748 -(% class="box infomessage" %)
749 -(((
750 750  **0x01 aa bb cc     ~/~/ Same as AT+TDC=0x(aa bb cc)**
751 -)))
752 752  
753 753  
754 754  
802 +
755 755  ==== 3.4.2.2 Set Work Mode (AT+MOD) ====
756 756  
805 +
757 757  Set work mode.
758 758  
759 759  * (% style="color:#037691" %)**AT Command:**
760 760  
761 -(% class="box infomessage" %)
762 -(((
763 763  **AT+MOD=N  **
764 -)))
765 765  
812 +
766 766  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
767 767  
768 768  
769 769  * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):**
770 770  
771 -(% class="box infomessage" %)
772 -(((
773 -**0x0A aa     ~/~/ Same as AT+MOD=aa**
774 -)))
818 +**0x0A aa    ** ~/~/ Same as AT+MOD=aa
775 775  
776 776  
777 777  
822 +
778 778  ==== 3.4.2.3 Poll an uplink ====
779 779  
780 -* (% style="color:#037691" %)AT Command:
781 781  
826 +* (% style="color:#037691" %)**AT Command:**
827 +
782 782  There is no AT Command to poll uplink
783 783  
784 784  
785 -* (% style="color:#037691" %)Downlink Payload (prefix 0x08):
831 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x08):**
786 786  
787 -(% class="box infomessage" %)
788 -(((
789 -**0x08 FF     ~/~/ Poll an uplink,**
790 -)))
833 +**0x08 FF     **~/~/ Poll an uplink
791 791  
835 +
792 792  **Example**: 0x08FF, ask device to send an Uplink
793 793  
794 794  
795 795  
840 +
796 796  ==== 3.4.2.4 Enable Trigger Mode ====
797 797  
843 +
798 798  Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
799 799  
800 -* (% style="color:#037691" %)AT Command:
846 +* (% style="color:#037691" %)**AT Command:**
801 801  
802 -(% class="box infomessage" %)
803 -(((
804 804  **AT+ADDMOD6=1 or 0**
805 -)))
806 806  
807 807  1: Enable Trigger Mode
808 808  
... ... @@ -809,43 +809,38 @@
809 809  0: Disable Trigger Mode
810 810  
811 811  
812 -* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06):
855 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):**
813 813  
814 -(% class="box infomessage" %)
815 -(((
816 -**0x0A 06 aa     ~/~/ Same as AT+ADDMOD6=aa,**
817 -)))
857 +**0x0A 06 aa    ** ~/~/ Same as AT+ADDMOD6=aa
818 818  
819 819  
820 820  
861 +
821 821  ==== 3.4.2.5 Poll trigger settings ====
822 822  
864 +
823 823  Poll trigger settings,
824 824  
825 -* (% style="color:#037691" %)AT Command:
867 +* (% style="color:#037691" %)**AT Command:**
826 826  
827 827  There is no AT Command for this feature.
828 828  
829 829  
830 -* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06):
872 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):**
831 831  
832 -(% class="box infomessage" %)
833 -(((
834 -**0xAB 06  ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command**
835 -)))
874 +**0xAB 06         **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command
836 836  
837 837  
838 838  
878 +
839 839  ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ====
840 840  
881 +
841 841  Enable Disable DI1/DI2/DI2 as trigger,
842 842  
843 -* (% style="color:#037691" %)AT Command:
884 +* (% style="color:#037691" %)**AT Command:**
844 844  
845 -(% class="box infomessage" %)
846 -(((
847 847  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
848 -)))
849 849  
850 850  
851 851  **Example:**
... ... @@ -852,25 +852,21 @@
852 852  
853 853  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
854 854  
855 -* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02):
893 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):**
856 856  
857 -(% class="box infomessage" %)
858 -(((
859 -**0xAA 02 aa bb  ~/~/ Same as AT+DTRI=aa,bb**
860 -)))
895 +**0xAA 02 aa bb        **~/~/ Same as AT+DTRI=aa,bb
861 861  
862 862  
863 863  
899 +
864 864  ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ====
865 865  
902 +
866 866  Set DI1 or DI3(for LT-33222-L) trigger.
867 867  
868 -* (% style="color:#037691" %)AT Command:
905 +* (% style="color:#037691" %)**AT Command:**
869 869  
870 -(% class="box infomessage" %)
871 -(((
872 872  **AT+TRIG1=a,b**
873 -)))
874 874  
875 875  a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1).
876 876  
... ... @@ -882,26 +882,22 @@
882 882  AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms )
883 883  
884 884  
885 -* (% style="color:#037691" %)Downlink Payload (prefix 0x09 01 ):
919 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):**
920 +* **0x09 01 aa bb cc    ** ~/~/ same as AT+TRIG1=aa,0x(bb cc)
886 886  
887 -(% class="box infomessage" %)
888 -(((
889 -**0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)**
890 -)))
891 891  
892 892  
893 893  
894 894  ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
895 895  
927 +
896 896  Set DI2 trigger.
897 897  
898 -* (% style="color:#037691" %)AT Command:
930 +* (% style="color:#037691" %)**AT Command:**
899 899  
900 -(% class="box infomessage" %)
901 -(((
902 902  **AT+TRIG2=a,b**
903 -)))
904 904  
934 +
905 905  a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1).
906 906  
907 907  b : delay timing.
... ... @@ -912,93 +912,82 @@
912 912  AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms )
913 913  
914 914  
915 -* (% style="color:#037691" %)Downlink Payload (prefix 0x09 02 ):
945 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):**
916 916  
917 -(% class="box infomessage" %)
918 -(((
919 -**0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)**
920 -)))
947 +**0x09 02 aa bb cc           **~/~/ same as AT+TRIG1=aa,0x(bb cc)
921 921  
922 922  
923 923  
951 +
924 924  ==== 3.4.2.9 Trigger – Set AC (current) as trigger ====
925 925  
954 +
926 926  Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
927 927  
928 -* (% style="color:#037691" %)AT Command:
957 +* (% style="color:#037691" %)**AT Command**
929 929  
930 -(% class="box infomessage" %)
931 -(((
932 -**AT+ACLIM. **
933 -)))
959 +**AT+ACLIM**
934 934  
935 935  
936 -* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 01 ):
962 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )**
937 937  
938 -(% class="box infomessage" %)
939 -(((
940 -**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
941 -)))
964 +**0x AA 01 aa bb cc dd ee ff gg hh        ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
942 942  
943 943  
944 944  
968 +
945 945  ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ====
946 946  
971 +
947 947  Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
948 948  
949 -* (% style="color:#037691" %)AT Command:
974 +* (% style="color:#037691" %)**AT Command**
950 950  
951 -(% class="box infomessage" %)
952 -(((
953 -**AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
954 -)))
976 +**AT+AVLIM  See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
955 955  
956 956  
957 -* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 00 ):
979 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )**
958 958  
959 -(% class="box infomessage" %)
960 -(((
961 -**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] **
962 -)))
981 +**0x AA 00 aa bb cc dd ee ff gg hh    ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
963 963  
964 964  
965 965  
985 +
966 966  ==== 3.4.2.11 Trigger – Set minimum interval ====
967 967  
968 -Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger.
969 969  
970 -* (% style="color:#037691" %)AT Command:
989 +Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger.
971 971  
972 -(% class="box infomessage" %)
973 -(((
974 -**AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.**
975 -)))
991 +* (% style="color:#037691" %)**AT Command**
976 976  
993 +**AT+ATDC=5        ** Device won't response the second trigger within 5 minute after the first trigger.
977 977  
978 -* (% style="color:#037691" %)Downlink Payload (prefix 0xAC ):
979 979  
980 -(% class="box infomessage" %)
996 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )**
997 +
998 +**0x AC aa bb   ** ~/~/ same as AT+ATDC=0x(aa bb)   . Unit (min)
999 +
981 981  (((
982 -**0x AC aa bb ~/~/ same as AT+ATDC=0x(aa bb)   . Unit (min)**
1001 +
1002 +
1003 +(% style="color:red" %)**Note: ATDC setting must be more than 5min**
983 983  )))
984 984  
985 985  
986 986  
1008 +
987 987  ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ====
988 988  
989 -* (% style="color:#037691" %)AT Command:
990 990  
1012 +* (% style="color:#037691" %)**AT Command**
1013 +
991 991  There is no AT Command to control Digital Output
992 992  
993 993  
994 -* (% style="color:#037691" %)Downlink Payload (prefix 0x02):
1017 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x02)**
1018 +* **0x02 aa bb cc     **~/~/ Set DO1/DO2/DO3 output
995 995  
996 -(% class="box infomessage" %)
997 997  (((
998 -**0x02 aa bb cc     ~/~/ Set DO1/DO2/DO3 output**
999 -)))
1000 -
1001 -(((
1002 1002  If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low.
1003 1003  )))
1004 1004  
... ... @@ -1009,31 +1009,29 @@
1009 1009  [[image:image-20220524092754-5.png]]
1010 1010  
1011 1011  (((
1012 -(% style="color:red" %)Note: For LT-22222-L, there is no DO3, the last byte can use any value.
1031 +(% style="color:red" %)**Note: For LT-22222-L, there is no DO3, the last byte can use any value.**
1013 1013  )))
1014 1014  
1015 1015  (((
1016 -(% style="color:red" %)Device will upload a packet if downlink code executes successfully.
1035 +(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.**
1017 1017  )))
1018 1018  
1019 1019  
1020 1020  
1040 +
1021 1021  ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ====
1022 1022  
1023 -* (% style="color:#037691" %)AT Command:
1024 1024  
1044 +* (% style="color:#037691" %)**AT Command**
1045 +
1025 1025  There is no AT Command to control Digital Output
1026 1026  
1027 1027  
1028 -* (% style="color:#037691" %)Downlink Payload (prefix 0xA9):
1049 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA9)**
1029 1029  
1030 -(% class="box infomessage" %)
1031 -(((
1032 -(((
1033 -**0xA9 aa bb cc     ~/~/ Set DO1/DO2/DO3 output with time control**
1034 -)))
1035 -)))
1051 +**0xA9 aa bb cc     **~/~/ Set DO1/DO2/DO3 output with time control
1036 1036  
1053 +
1037 1037  This is to control the digital output time of DO pin. Include four bytes:
1038 1038  
1039 1039  (% style="color:#4f81bd" %)**First Byte**(%%)**:** Type code (0xA9)
... ... @@ -1060,11 +1060,11 @@
1060 1060  [[image:image-20220524093351-8.png]]
1061 1061  
1062 1062  
1063 -(% style="color:#4f81bd" %)**Sixth and Seventh Byte**:
1080 +(% style="color:#4f81bd" %)**Sixth and Seventh and Eighth and Ninth Byte**:
1064 1064  
1065 1065   Latching time. Unit: ms
1066 1066  
1067 -Device will upload a packet if downlink code executes successfully.
1084 +(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.**
1068 1068  
1069 1069  
1070 1070  **Example payload:**
... ... @@ -1087,20 +1087,20 @@
1087 1087  
1088 1088  
1089 1089  
1107 +
1090 1090  ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1091 1091  
1092 -* (% style="color:#037691" %)AT Command:
1093 1093  
1111 +* (% style="color:#037691" %)**AT Command:**
1112 +
1094 1094  There is no AT Command to control Relay Output
1095 1095  
1096 1096  
1097 -* (% style="color:#037691" %)Downlink Payload (prefix 0x03):
1116 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x03):**
1098 1098  
1099 -(% class="box infomessage" %)
1100 -(((
1101 -**0x03 aa bb     ~/~/ Set RO1/RO2 output**
1102 -)))
1118 +**0x03 aa bb     **~/~/ Set RO1/RO2 output
1103 1103  
1120 +
1104 1104  (((
1105 1105  If payload = 0x030100, it means set RO1 to close and RO2 to open.
1106 1106  )))
... ... @@ -1113,24 +1113,24 @@
1113 1113  [[image:image-20220524093724-9.png]]
1114 1114  )))
1115 1115  
1116 -Device will upload a packet if downlink code executes successfully.
1133 +(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.**
1117 1117  
1118 1118  
1119 1119  
1137 +
1120 1120  ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ====
1121 1121  
1122 -* (% style="color:#037691" %)AT Command:
1123 1123  
1141 +* (% style="color:#037691" %)**AT Command:**
1142 +
1124 1124  There is no AT Command to control Relay Output
1125 1125  
1126 1126  
1127 -* (% style="color:#037691" %)Downlink Payload (prefix 0x05):
1146 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x05):**
1128 1128  
1129 -(% class="box infomessage" %)
1130 -(((
1131 -**0x05 aa bb cc dd     ~/~/ Set RO1/RO2 relay with time control:**
1132 -)))
1148 +**0x05 aa bb cc dd     **~/~/ Set RO1/RO2 relay with time control
1133 1133  
1150 +
1134 1134  This is to control the relay output time of relay. Include four bytes:
1135 1135  
1136 1136  (% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05)
... ... @@ -1144,63 +1144,57 @@
1144 1144  
1145 1145  (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status:
1146 1146  
1147 -[[image:image-20220524093831-10.png]]
1164 +[[image:image-20220714135731-1.png||height="406" width="627"]]
1148 1148  
1149 1149  
1150 -(% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms
1167 +(% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh Bytes(cc)**(%%): Latching time. Unit: ms
1151 1151  
1152 -Device will upload a packet if downlink code executes successfully.
1169 +(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.**
1153 1153  
1154 1154  
1155 1155  **Example payload:**
1156 1156  
1157 -**~1. 05 01 11 07 D0**
1174 +**~1. 05 01 11 07 D**
1158 1158  
1159 -Relay1 and Relay 2 will be set to NO , last 2 seconds, then change back to original state.
1176 +Relay1 and Relay 2 will be set to NC , last 2 seconds, then change back to original state.
1160 1160  
1161 1161  **2. 05 01 10 07 D0**
1162 1162  
1163 -Relay1 will change to NO, Relay2 will change to NC, last 2 seconds, then both change back to original state.
1180 +Relay1 will change to NC, Relay2 will change to NO, last 2 seconds, then both change back to original state.
1164 1164  
1165 1165  **3. 05 00 01 07 D0**
1166 1166  
1167 -Relay1 will change to NC, Relay2 will change to NO, last 2 seconds, then relay change to NO, Relay2 change to NC.
1184 +Relay1 will change to NO, Relay2 will change to NC, last 2 seconds, then relay change to NC,Relay2 change to NO.
1168 1168  
1169 1169  **4. 05 00 00 07 D0**
1170 1170  
1171 -Relay 1 & relay2 will change to NC, last 2 seconds, then both change to NO.
1188 +Relay 1 & relay2 will change to NO, last 2 seconds, then both change to NC.
1172 1172  
1173 1173  
1174 1174  
1175 1175  ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ====
1176 1176  
1194 +
1177 1177  When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1178 1178  
1179 -* (% style="color:#037691" %)AT Command:
1197 +* (% style="color:#037691" %)**AT Command:**
1180 1180  
1181 -(% class="box infomessage" %)
1182 -(((
1183 -**AT+VOLMAX    ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]**
1184 -)))
1199 +**AT+VOLMAX   ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1185 1185  
1186 1186  
1187 -* (% style="color:#037691" %)Downlink Payload (prefix 0xA5):
1202 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):**
1188 1188  
1189 -(% class="box infomessage" %)
1190 -(((
1191 -**0xA5 aa bb cc   ~/~/ Same as AT+VOLMAX=(aa bb),cc**
1192 -)))
1204 +**0xA5 aa bb cc   **~/~/ Same as AT+VOLMAX=(aa bb),cc
1193 1193  
1194 1194  
1195 1195  
1208 +
1196 1196  ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ====
1197 1197  
1198 -* (% style="color:#037691" %)AT Command:
1199 1199  
1200 -(% class="box infomessage" %)
1201 -(((
1212 +* (% style="color:#037691" %)**AT Command:**
1213 +
1202 1202  **AT+SETCNT=aa,(bb cc dd ee) **
1203 -)))
1204 1204  
1205 1205  aa: 1: Set count1,
1206 1206  
... ... @@ -1211,37 +1211,33 @@
1211 1211  Bb cc dd ee: number to be set
1212 1212  
1213 1213  
1214 -* (% style="color:#037691" %)Downlink Payload (prefix 0xA8):
1225 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA8):**
1215 1215  
1216 -(% class="box infomessage" %)
1217 -(((
1218 -**0x A8 aa bb cc dd ee     ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)**
1219 -)))
1227 +**0x A8 aa bb cc dd ee     **~/~/ same as AT+SETCNT=aa,(bb cc dd ee)
1220 1220  
1221 1221  
1222 1222  
1231 +
1223 1223  ==== 3.4.2.18 Counting ~-~- Clear Counting ====
1224 1224  
1234 +
1225 1225  Clear counting for counting mode
1226 1226  
1227 -* (% style="color:#037691" %)AT Command:
1237 +* (% style="color:#037691" %)**AT Command:**
1228 1228  
1229 -(% class="box infomessage" %)
1230 -(((
1231 -**AT+CLRCOUNT ~/~/ clear all counting**
1232 -)))
1239 +**AT+CLRCOUNT ** ~/~/ clear all counting
1233 1233  
1234 -* (% style="color:#037691" %)Downlink Payload (prefix 0xA6):
1235 1235  
1236 -(% class="box infomessage" %)
1237 -(((
1238 -**0x A6 01     ~/~/ clear all counting,**
1239 -)))
1242 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):**
1240 1240  
1244 +**0x A6 01    ** ~/~/ clear all counting
1241 1241  
1242 1242  
1247 +
1248 +
1243 1243  ==== 3.4.2.19 Counting ~-~- Change counting mode save time ====
1244 1244  
1251 +
1245 1245  * (% style="color:#037691" %)**AT Command:**
1246 1246  
1247 1247  **AT+COUTIME=60  **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)
... ... @@ -1254,12 +1254,124 @@
1254 1254  (((
1255 1255  range: aa bb cc:0 to 16777215,  (unit:second)
1256 1256  
1264 +
1265 +
1257 1257  
1258 1258  )))
1259 1259  
1269 +==== 3.4.2.20 Reset save DR DO state ====
1260 1260  
1271 +
1272 +* (% style="color:#037691" %)**AT Command:**
1273 +
1274 +**AT+RODORET=1  **~/~/ RODO will close when the device joining the network. (default)
1275 +
1276 +**AT+RODORET=0  **~/~/After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state is not changed when it is reconnected to the network.
1277 +
1278 +
1279 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAD):**
1280 +
1281 +**0x AD aa      **~/~/ same as AT+RODORET =aa
1282 +
1283 +(((
1284 +
1285 +
1286 +
1287 +
1288 +==== 3.4.2.21 Encrypted payload ====
1289 +
1290 +
1291 +* (% style="color:#037691" %)**AT Command:**
1292 +
1293 +**AT+DECRYPT=1  **~/~/ The payload is uploaded without encryption
1294 +
1295 +**AT+DECRYPT=0  **~/~/Encrypt when uploading payload (default)
1296 +
1297 +
1298 +
1299 +
1300 +==== 3.4.2.22 Get sensor value ====
1301 +
1302 +
1303 +* (% style="color:#037691" %)**AT Command:**
1304 +
1305 +**AT+GETSENSORVALUE=0  **~/~/ The serial port gets the reading of the current sensor
1306 +
1307 +**AT+GETSENSORVALUE=1  **~/~/The serial port gets the current sensor reading and uploads it.
1308 +
1309 +
1310 +
1311 +
1312 +==== 3.4.2.23 Resets the downlink packet count ====
1313 +
1314 +
1315 +* (% style="color:#037691" %)**AT Command:**
1316 +
1317 +**AT+DISFCNTCHECK=0  **~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node will no longer receive downlink packets (default)
1318 +
1319 +**AT+DISFCNTCHECK=1  **~/~/When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node resets the downlink packet count and keeps it consistent with the server downlink packet count.
1320 +
1321 +
1322 +
1323 +
1324 +==== 3.4.2.24 When the limit bytes are exceeded, upload in batches ====
1325 +
1326 +
1327 +* (% style="color:#037691" %)**AT Command:**
1328 +
1329 + **AT+DISMACANS=0**  ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of 11 bytes (DR0 of US915, DR2 of AS923, DR2 of AU195), the node will send a packet with a payload of 00 and a port of 4. (default)
1330 +
1331 + **AT+DISMACANS=1**      ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of the DR, the node will ignore the MACANS and not reply, and only upload the payload part.
1332 +
1333 +
1334 +* (% style="color:#037691" %)**Downlink Payload **(%%)**:**
1335 +
1336 +**0x21 00 01 ** ~/~/ Set  the DISMACANS=1
1337 +
1338 +
1339 +
1340 +
1341 +==== 3.4.2.25 Copy downlink to uplink ====
1342 +
1343 +
1344 +* (% style="color:#037691" %)**AT Command**(%%)**:**
1345 +
1346 + **AT+RPL=5**  ~/~/ After receiving the package from the server, it will immediately upload the content of the package to the server, the port number is 100.
1347 +
1348 +Example:**aa xx xx xx xx**         ~/~/ aa indicates whether the configuration has changed, 00 is yes, 01 is no; xx xx xx xx are the bytes sent.
1349 +
1350 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173747-6.png?width=1124&height=165&rev=1.1||alt="image-20220823173747-6.png"]]
1351 +
1352 +For example, sending 11 22 33 44 55 66 77 will return invalid configuration 00 11 22 33 44 55 66 77.
1353 +
1354 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173833-7.png?width=1124&height=149&rev=1.1||alt="image-20220823173833-7.png"]]
1355 +
1356 +For example, if 01 00 02 58 is issued, a valid configuration of 01 01 00 02 58 will be returned.
1357 +
1358 +
1359 +
1360 +==== 3.4.2.26 Query version number and frequency band 、TDC ====
1361 +
1362 +
1363 +* (((
1364 +(% style="color:#037691" %)**Downlink Payload**(%%)**:**
1365 +
1366 +**26 01  ** ~/~/ Downlink 26 01 can query device upload frequency, frequency band, software version number, TDC time.
1367 +
1368 +
1369 +)))
1370 +
1371 +**Example:**
1372 +
1373 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173929-8.png?width=1205&height=76&rev=1.1||alt="image-20220823173929-8.png"]]
1374 +
1375 +
1376 +
1377 +)))
1378 +
1261 1261  == 3.5 Integrate with Mydevice ==
1262 1262  
1381 +
1263 1263  Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps:
1264 1264  
1265 1265  (((
... ... @@ -1268,14 +1268,15 @@
1268 1268  
1269 1269  (((
1270 1270  (% style="color:blue" %)**Step 2**(%%): To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps:
1390 +
1391 +
1271 1271  )))
1272 1272  
1273 -[[image:1653356737703-362.png||height="232" width="732"]]
1394 +[[image:image-20220719105525-1.png||height="377" width="677"]]
1274 1274  
1275 -[[image:image-20220524094641-11.png||height="390" width="723"]]
1276 1276  
1277 1277  
1278 -[[image:image-20220524094641-12.png||height="402" width="718"]]
1398 +[[image:image-20220719110247-2.png||height="388" width="683"]]
1279 1279  
1280 1280  
1281 1281  (% style="color:blue" %)**Step 3**(%%): Create an account or log in Mydevices.
... ... @@ -1308,8 +1308,10 @@
1308 1308  
1309 1309  == 3.6 Interface Detail ==
1310 1310  
1431 +
1311 1311  === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) ===
1312 1312  
1434 +
1313 1313  Support NPN Type sensor
1314 1314  
1315 1315  [[image:1653356991268-289.png]]
... ... @@ -1318,6 +1318,7 @@
1318 1318  
1319 1319  === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) ===
1320 1320  
1443 +
1321 1321  (((
1322 1322  The DI port of LT-22222-L can support NPN or PNP output sensor.
1323 1323  )))
... ... @@ -1324,7 +1324,9 @@
1324 1324  
1325 1325  (((
1326 1326  (((
1327 -Internal circuit as below, the NEC2501 is a photocoupler, the Active current (from NEC2501 pin 1 to pin 2 is 1ma and the max current is 50mA. When there is active current pass NEC2501 pin1 to pin2. The DI will be active high
1450 +Internal circuit as below, the NEC2501 is a photocoupler, the Active current (from NEC2501 pin 1 to pin 2 is 1ma and the max current is 50mA. When there is active current pass NEC2501 pin1 to pin2. The DI will be active high.
1451 +
1452 +
1328 1328  )))
1329 1329  )))
1330 1330  
... ... @@ -1349,10 +1349,10 @@
1349 1349  )))
1350 1350  
1351 1351  * (((
1352 -Connect sensors output to DI1-
1477 +Connect sensor's output to DI1-
1353 1353  )))
1354 1354  * (((
1355 -Connect sensors VCC to DI1+.
1480 +Connect sensor's VCC to DI1+.
1356 1356  )))
1357 1357  
1358 1358  (((
... ... @@ -1360,15 +1360,17 @@
1360 1360  )))
1361 1361  
1362 1362  (((
1363 -[[image:1653968155772-850.png||height="23" width="19"]]**= DI1+ / 1K.**
1488 +[[image:1653968155772-850.png||height="23" width="19"]]**= DI1**+** / 1K.**
1364 1364  )))
1365 1365  
1366 1366  (((
1367 -If DI1+ = 12v, the [[image:1653968155772-850.png||height="23" width="19"]]= 12mA , So the LT-22222-L will be able to detect this active signal.
1492 +If** DI1+ **= **12v**, the [[image:1653968155772-850.png||height="23" width="19"]]= 12mA , So the LT-22222-L will be able to detect this active signal.
1368 1368  )))
1369 1369  
1370 1370  (((
1371 1371  
1497 +
1498 +
1372 1372  )))
1373 1373  
1374 1374  (((
... ... @@ -1380,10 +1380,10 @@
1380 1380  )))
1381 1381  
1382 1382  * (((
1383 -Connect sensors output to DI1+
1510 +Connect sensor's output to DI1+
1384 1384  )))
1385 1385  * (((
1386 -Connect sensors GND DI1-.
1513 +Connect sensor's GND DI1-.
1387 1387  )))
1388 1388  
1389 1389  (((
... ... @@ -1400,6 +1400,8 @@
1400 1400  
1401 1401  (((
1402 1402  
1530 +
1531 +
1403 1403  )))
1404 1404  
1405 1405  (((
... ... @@ -1411,10 +1411,10 @@
1411 1411  )))
1412 1412  
1413 1413  * (((
1414 -Connect sensors output to DI1+ with a serial 50K resistor
1543 +Connect sensor's output to DI1+ with a serial 50K resistor
1415 1415  )))
1416 1416  * (((
1417 -Connect sensors GND DI1-.
1546 +Connect sensor's GND DI1-.
1418 1418  )))
1419 1419  
1420 1420  (((
... ... @@ -1433,6 +1433,7 @@
1433 1433  
1434 1434  === 3.6.3 Digital Output Port: DO1/DO2 /DO3 ===
1435 1435  
1565 +
1436 1436  NPN output: GND or Float. Max voltage can apply to output pin is 36v.
1437 1437  
1438 1438  [[image:1653357531600-905.png]]
... ... @@ -1441,6 +1441,7 @@
1441 1441  
1442 1442  === 3.6.4 Analog Input Interface ===
1443 1443  
1574 +
1444 1444  The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is:
1445 1445  
1446 1446  
... ... @@ -1472,6 +1472,7 @@
1472 1472  
1473 1473  === 3.6.5 Relay Output ===
1474 1474  
1606 +
1475 1475  (((
1476 1476  The LT serial controller has two relay interfaces; each interface uses two pins of the screw terminal. User can connect other device’s Power Line to in serial of RO1_1 and RO_2. Such as below:
1477 1477  )))
... ... @@ -1478,6 +1478,7 @@
1478 1478  
1479 1479  [[image:image-20220524100215-9.png]]
1480 1480  
1613 +
1481 1481  [[image:image-20220524100215-10.png||height="382" width="723"]]
1482 1482  
1483 1483  
... ... @@ -1484,13 +1484,17 @@
1484 1484  
1485 1485  == 3.7 LEDs Indicators ==
1486 1486  
1620 +
1487 1487  [[image:image-20220524100748-11.png]]
1488 1488  
1489 1489  
1624 +
1490 1490  = 4. Use AT Command =
1491 1491  
1627 +
1492 1492  == 4.1 Access AT Command ==
1493 1493  
1630 +
1494 1494  LT supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to LT for using AT command, as below.
1495 1495  
1496 1496  [[image:1653358238933-385.png]]
... ... @@ -1689,8 +1689,6 @@
1689 1689  
1690 1690  (((
1691 1691  AT+CFG: Print all settings
1692 -
1693 -
1694 1694  )))
1695 1695  
1696 1696  
... ... @@ -1697,6 +1697,7 @@
1697 1697  
1698 1698  == 4.2 Common AT Command Sequence ==
1699 1699  
1835 +
1700 1700  === 4.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
1701 1701  
1702 1702  (((
... ... @@ -1736,8 +1736,6 @@
1736 1736  
1737 1737  (((
1738 1738  (% style="background-color:#dcdcdc" %)ATZ
1739 -
1740 -
1741 1741  )))
1742 1742  
1743 1743  
... ... @@ -1809,6 +1809,8 @@
1809 1809  2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1810 1810  3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1811 1811  4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1946 +
1947 +
1812 1812  )))
1813 1813  
1814 1814  (((
... ... @@ -1822,13 +1822,16 @@
1822 1822  
1823 1823  === 4.2.3 Change to Class A ===
1824 1824  
1961 +
1825 1825  If sensor JOINED
1826 1826  (% style="background-color:#dcdcdc" %)AT+CLASS=A
1827 1827  ATZ
1828 1828  
1829 1829  
1967 +
1830 1830  = 5. FAQ =
1831 1831  
1970 +
1832 1832  == 5.1 How to upgrade the image? ==
1833 1833  
1834 1834  
... ... @@ -1845,12 +1845,14 @@
1845 1845  
1846 1846  (((
1847 1847  (% style="color:blue" %)**Step1**(%%)**:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
1848 -(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].
1987 +(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:https://www.dropbox.com/sh/g99v0fxcltn9r1y/AADKXQ2v5ZT-S3sxdmbvE7UAa/LT-22222-L/image?dl=0&subfolder_nav_tracking=1]].
1849 1849  (% style="color:blue" %)**Step3**(%%)**:** Open flashloader; choose the correct COM port to update.
1850 1850  
1851 1851  
1852 1852  (% style="color:blue" %)**For LT-22222-L**(%%):
1853 -Hold down the PRO button and then momentarily press the RST reset button and the **DO1 led** will change from OFF to ON. When **DO1 LED** is on, it means the device is in download mode.
1992 +Hold down the PRO button and then momentarily press the RST reset button and the (% style="color:red" %)**DO1 led**(%%) will change from OFF to ON. When (% style="color:red" %)**DO1 LED**(%%) is on, it means the device is in download mode.
1993 +
1994 +
1854 1854  )))
1855 1855  
1856 1856   [[image:image-20220524103407-12.png]]
... ... @@ -1862,6 +1862,7 @@
1862 1862  
1863 1863  (% style="color:red" %)**Notice**(%%): In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:
1864 1864  
2006 +
1865 1865  [[image:1653360054704-518.png||height="186" width="745"]]
1866 1866  
1867 1867  
... ... @@ -1870,6 +1870,8 @@
1870 1870  
1871 1871  
1872 1872  == 5.2 How to change the LoRa Frequency Bands/Region? ==
2015 +
2016 +
1873 1873  )))
1874 1874  )))
1875 1875  
... ... @@ -1880,7 +1880,10 @@
1880 1880  (((
1881 1881  
1882 1882  
2027 +
1883 1883  == 5.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? ==
2029 +
2030 +
1884 1884  )))
1885 1885  
1886 1886  (((
... ... @@ -1893,25 +1893,33 @@
1893 1893  (((
1894 1894  Assume we have a LG02 working in the frequency 868400000 now , below is the step.
1895 1895  
2043 +
1896 1896  
1897 1897  )))
1898 1898  )))
1899 1899  
1900 1900  (((
1901 -(% style="color:#4f81bd" %)**Step1**(%%): Log in TTN, Create an ABP device in the application and input the network session key (NETSKEY), app session key (APPSKEY) from the device.
2049 +(% style="color:blue" %)**Step1**(%%):  Log in TTN, Create an ABP device in the application and input the network session key (NETSKEY), app session key (APPSKEY) from the device.
2050 +
2051 +
1902 1902  )))
1903 1903  
1904 1904  (((
1905 1905  [[image:1653360231087-571.png||height="401" width="727"]]
2056 +
2057 +
1906 1906  )))
1907 1907  
1908 1908  (((
1909 -(% style="color:red" %)Note: user just need to make sure above three keys match, User can change either in TTN or Device to make then match. In TTN, NETSKEY and APPSKEY can be configured by user in setting page, but Device Addr is generated by TTN.
2061 +(% style="color:red" %)**Note: user just need to make sure above three keys match, User can change either in TTN or Device to make then match. In TTN, NETSKEY and APPSKEY can be configured by user in setting page, but Device Addr is generated by TTN.**
1910 1910  )))
1911 1911  
1912 1912  
2065 +
1913 1913  (((
1914 -(% style="color:#4f81bd" %)**Step2**(%%)**: **Run AT Command to make LT work in Single frequency & ABP mode. Below is the AT commands:
2067 +(% style="color:blue" %)**Step2**(%%)**:  **Run AT Command to make LT work in Single frequency & ABP mode. Below is the AT commands:
2068 +
2069 +
1915 1915  )))
1916 1916  
1917 1917  (((
... ... @@ -1935,20 +1935,28 @@
1935 1935  [[image:1653360498588-932.png||height="485" width="726"]]
1936 1936  
1937 1937  
2093 +
1938 1938  == 5.4 Can I see counting event in Serial? ==
1939 1939  
2096 +
1940 1940  (((
1941 -User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesnt support AT+DEBUG. User can update to latest firmware first.
2098 +User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn't support AT+DEBUG. User can update to latest firmware first.
1942 1942  
1943 1943  
2101 +
1944 1944  == 5.5 Can i use point to point communication for LT-22222-L? ==
1945 1945  
2104 +
1946 1946  Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]]
2106 +
2107 +
2108 +
1947 1947  )))
1948 1948  
1949 1949  (((
1950 1950  == 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? ==
1951 1951  
2114 +
1952 1952  If the device is not shut down, but directly powered off.
1953 1953  
1954 1954  It will default that this is a power-off state.
... ... @@ -1957,12 +1957,18 @@
1957 1957  
1958 1958  After restart, the status before power failure will be read from flash.
1959 1959  
2123 +
2124 +
1960 1960  = 6. Trouble Shooting =
2126 +
2127 +
1961 1961  )))
1962 1962  
1963 1963  (((
1964 1964  (((
1965 -== 6.1 Downlink doesn’t work, how to solve it? ==
2132 +== 6.1 Downlink doesn't work, how to solve it? ==
2133 +
2134 +
1966 1966  )))
1967 1967  )))
1968 1968  
... ... @@ -1973,7 +1973,10 @@
1973 1973  (((
1974 1974  
1975 1975  
2145 +
1976 1976  == 6.2 Have trouble to upload image. ==
2147 +
2148 +
1977 1977  )))
1978 1978  
1979 1979  (((
... ... @@ -1983,7 +1983,10 @@
1983 1983  (((
1984 1984  
1985 1985  
1986 -== 6.3 Why I can’t join TTN in US915 /AU915 bands? ==
2158 +
2159 +== 6.3 Why I can't join TTN in US915 /AU915 bands? ==
2160 +
2161 +
1987 1987  )))
1988 1988  
1989 1989  (((
... ... @@ -1997,19 +1997,21 @@
1997 1997  
1998 1998  (% style="color:#4f81bd" %)**LT-22222-L-XXX:**
1999 1999  
2000 -
2001 2001  (% style="color:#4f81bd" %)**XXX:**
2002 2002  
2003 -* (% style="color:#4f81bd" %)**EU433**(%%): LT with frequency bands EU433
2004 -* (% style="color:#4f81bd" %)**EU868**(%%): LT with frequency bands EU868
2005 -* (% style="color:#4f81bd" %)**KR920**(%%): LT with frequency bands KR920
2006 -* (% style="color:#4f81bd" %)**CN470**(%%): LT with frequency bands CN470
2007 -* (% style="color:#4f81bd" %)**AS923**(%%): LT with frequency bands AS923
2008 -* (% style="color:#4f81bd" %)**AU915**(%%): LT with frequency bands AU915
2009 -* (% style="color:#4f81bd" %)**US915**(%%): LT with frequency bands US915
2010 -* (% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865
2011 -* (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779
2177 +* (% style="color:red" %)**EU433**(%%):  LT with frequency bands EU433
2178 +* (% style="color:red" %)**EU868**(%%):  LT with frequency bands EU868
2179 +* (% style="color:red" %)**KR920**(%%):  LT with frequency bands KR920
2180 +* (% style="color:red" %)**CN470**(%%):  LT with frequency bands CN470
2181 +* (% style="color:red" %)**AS923**(%%):  LT with frequency bands AS923
2182 +* (% style="color:red" %)**AU915**(%%):  LT with frequency bands AU915
2183 +* (% style="color:red" %)**US915**(%%):  LT with frequency bands US915
2184 +* (% style="color:red" %)**IN865**(%%):  LT with frequency bands IN865
2185 +* (% style="color:red" %)**CN779**(%%):  LT with frequency bands CN779
2012 2012  
2187 +
2188 +
2189 +
2013 2013  = 8. Packing Info =
2014 2014  
2015 2015  
... ... @@ -2027,18 +2027,28 @@
2027 2027  * Package Size / pcs : 14.5 x 8 x 5 cm
2028 2028  * Weight / pcs : 170g
2029 2029  
2207 +
2208 +
2209 +
2030 2030  = 9. Support =
2031 2031  
2212 +
2032 2032  * (((
2033 2033  Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
2034 2034  )))
2035 2035  * (((
2036 2036  Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
2218 +
2219 +
2220 +
2221 +
2037 2037  )))
2038 2038  
2039 2039  = 10. Reference​​​​​ =
2040 2040  
2226 +
2041 2041  * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]]
2042 -* [[Image Download>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]
2043 -* [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
2228 +* [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]]
2044 2044  * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]]
2230 +
2231 +
image-20220714135731-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bei
Size
... ... @@ -1,0 +1,1 @@
1 +54.1 KB
Content
image-20220719105525-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bei
Size
... ... @@ -1,0 +1,1 @@
1 +165.5 KB
Content
image-20220719110247-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bei
Size
... ... @@ -1,0 +1,1 @@
1 +52.9 KB
Content