Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bei1 +XWiki.Xiaoling - Content
-
... ... @@ -19,6 +19,8 @@ 19 19 == 1.1 What is LT Series I/O Controller == 20 20 21 21 ((( 22 + 23 + 22 22 The Dragino (% style="color:blue" %)**LT series I/O Modules**(%%) are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (% style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %), **relay output**, **digital input**(%%) and (% style="color:blue" %)**digital output**(%%) etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring. 23 23 ))) 24 24 ... ... @@ -163,9 +163,12 @@ 163 163 ))) 164 164 * ((( 165 165 Packet engine up to 256 bytes with CRC. 166 -))) 167 167 168 168 170 + 171 + 172 +))) 173 + 169 169 == 1.3 Features == 170 170 171 171 * LoRaWAN Class A & Class C protocol ... ... @@ -177,6 +177,7 @@ 177 177 * Counting 178 178 179 179 185 + 180 180 == 1.4 Applications == 181 181 182 182 * Smart Buildings & Home Automation ... ... @@ -187,6 +187,7 @@ 187 187 * Smart Factory 188 188 189 189 196 + 190 190 == 1.5 Hardware Variants == 191 191 192 192 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -281,6 +281,8 @@ 281 281 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 282 282 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 283 283 291 + 292 + 284 284 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 285 285 286 286 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -334,6 +334,8 @@ 334 334 ** DO1 is high in case there is load between DO1 and V+. 335 335 ** DO1 LED is off in both case 336 336 346 + 347 + 337 337 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 338 338 339 339 ... ... @@ -370,12 +370,7 @@ 370 370 ((( 371 371 ((( 372 372 **AT+MOD=2** 373 -))) 374 -))) 375 375 376 -(% class="box infomessage" %) 377 -((( 378 -((( 379 379 **ATZ** 380 380 ))) 381 381 ))) ... ... @@ -394,40 +394,15 @@ 394 394 ((( 395 395 ((( 396 396 **AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 397 -))) 398 -))) 399 399 400 -(% class="box infomessage" %) 401 -((( 402 -((( 403 403 **AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 404 -))) 405 -))) 406 406 407 -(% class="box infomessage" %) 408 -((( 409 -((( 410 410 **AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 411 -))) 412 -))) 413 413 414 -(% class="box infomessage" %) 415 -((( 416 -((( 417 417 **AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 418 -))) 419 -))) 420 420 421 -(% class="box infomessage" %) 422 -((( 423 -((( 424 424 **AT+SETCNT=1,60 (Set COUNT1 value to 60)** 425 -))) 426 -))) 427 427 428 -(% class="box infomessage" %) 429 -((( 430 -((( 431 431 **AT+SETCNT=2,60 (Set COUNT2 value to 60)** 432 432 ))) 433 433 ))) ... ... @@ -462,12 +462,7 @@ 462 462 ((( 463 463 ((( 464 464 **AT+MOD=3** 465 -))) 466 -))) 467 467 468 -(% class="box infomessage" %) 469 -((( 470 -((( 471 471 **ATZ** 472 472 ))) 473 473 ))) ... ... @@ -512,20 +512,13 @@ 512 512 ((( 513 513 ((( 514 514 **AT+MOD=4** 515 -))) 516 -))) 517 517 518 -(% class="box infomessage" %) 519 -((( 520 -((( 521 521 **ATZ** 522 522 ))) 523 523 ))) 524 524 525 -((( 526 - 527 -))) 528 528 497 + 529 529 ((( 530 530 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 531 531 ))) ... ... @@ -539,33 +539,17 @@ 539 539 (% class="box infomessage" %) 540 540 ((( 541 541 ((( 542 -**AT+SETCNT=3,60 (set AVI Count to 60)** 543 -))) 544 -))) 511 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 545 545 546 -(% class="box infomessage" %) 547 -((( 548 -((( 549 -**AT+VOLMAX=20000 (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 550 -))) 551 -))) 513 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 552 552 553 -(% class="box infomessage" %) 554 -((( 555 -((( 556 -**AT+VOLMAX=20000,0 (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 557 -))) 558 -))) 515 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 559 559 560 -(% class="box infomessage" %) 561 -((( 562 -((( 563 -**AT+VOLMAX=20000,1 (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 517 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 564 564 ))) 565 565 ))) 566 566 567 567 568 - 569 569 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 570 570 571 571 ... ... @@ -599,12 +599,7 @@ 599 599 ((( 600 600 ((( 601 601 **AT+MOD=5** 602 -))) 603 -))) 604 604 605 -(% class="box infomessage" %) 606 -((( 607 -((( 608 608 **ATZ** 609 609 ))) 610 610 ))) ... ... @@ -630,7 +630,7 @@ 630 630 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 631 631 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 632 632 633 -**AT Command to set Trigger Condition**: 581 +(% style="color:#037691" %)**AT Command to set Trigger Condition**: 634 634 635 635 (% style="color:#4f81bd" %)**Trigger base on voltage**: 636 636 ... ... @@ -666,7 +666,7 @@ 666 666 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 667 667 668 668 669 -**Downlink Command to set Trigger Condition:** 617 +(% style="color:#037691" %)**Downlink Command to set Trigger Condition:** 670 670 671 671 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 672 672 ... ... @@ -771,6 +771,8 @@ 771 771 772 772 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 773 773 722 + 723 + 774 774 === 3.4.1 Common Commands === 775 775 776 776 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -783,7 +783,7 @@ 783 783 784 784 Set device uplink interval. 785 785 786 -* AT Command: 736 +* (% style="color:#037691" %)**AT Command:** 787 787 788 788 (% class="box infomessage" %) 789 789 ((( ... ... @@ -793,7 +793,7 @@ 793 793 **Example: **AT+TDC=30000. Means set interval to 30 seconds 794 794 795 795 796 -* Downlink Payload (prefix 0x01): 746 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 797 797 798 798 (% class="box infomessage" %) 799 799 ((( ... ... @@ -806,7 +806,7 @@ 806 806 807 807 Set work mode. 808 808 809 -* AT Command: 759 +* (% style="color:#037691" %)**AT Command:** 810 810 811 811 (% class="box infomessage" %) 812 812 ((( ... ... @@ -816,7 +816,7 @@ 816 816 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 817 817 818 818 819 -* Downlink Payload (prefix 0x0A): 769 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 820 820 821 821 (% class="box infomessage" %) 822 822 ((( ... ... @@ -827,12 +827,12 @@ 827 827 828 828 ==== 3.4.2.3 Poll an uplink ==== 829 829 830 -* AT Command: 780 +* (% style="color:#037691" %)AT Command: 831 831 832 832 There is no AT Command to poll uplink 833 833 834 834 835 -* Downlink Payload (prefix 0x08): 785 +* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 836 836 837 837 (% class="box infomessage" %) 838 838 ((( ... ... @@ -847,7 +847,7 @@ 847 847 848 848 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 849 849 850 -* AT Command: 800 +* (% style="color:#037691" %)AT Command: 851 851 852 852 (% class="box infomessage" %) 853 853 ((( ... ... @@ -859,7 +859,7 @@ 859 859 0: Disable Trigger Mode 860 860 861 861 862 -* Downlink Payload (prefix 0x0A 06): 812 +* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 863 863 864 864 (% class="box infomessage" %) 865 865 ((( ... ... @@ -872,12 +872,12 @@ 872 872 873 873 Poll trigger settings, 874 874 875 -* AT Command: 825 +* (% style="color:#037691" %)AT Command: 876 876 877 877 There is no AT Command for this feature. 878 878 879 879 880 -* Downlink Payload (prefix 0x AB 06): 830 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 881 881 882 882 (% class="box infomessage" %) 883 883 ((( ... ... @@ -890,7 +890,7 @@ 890 890 891 891 Enable Disable DI1/DI2/DI2 as trigger, 892 892 893 -* AT Command: 843 +* (% style="color:#037691" %)AT Command: 894 894 895 895 (% class="box infomessage" %) 896 896 ((( ... ... @@ -902,7 +902,7 @@ 902 902 903 903 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 904 904 905 -* Downlink Payload (prefix 0xAA 02): 855 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 906 906 907 907 (% class="box infomessage" %) 908 908 ((( ... ... @@ -915,7 +915,7 @@ 915 915 916 916 Set DI1 or DI3(for LT-33222-L) trigger. 917 917 918 -* AT Command: 868 +* (% style="color:#037691" %)AT Command: 919 919 920 920 (% class="box infomessage" %) 921 921 ((( ... ... @@ -932,7 +932,7 @@ 932 932 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 933 933 934 934 935 -* Downlink Payload (prefix 0x09 01 ): 885 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 01 ): 936 936 937 937 (% class="box infomessage" %) 938 938 ((( ... ... @@ -945,7 +945,7 @@ 945 945 946 946 Set DI2 trigger. 947 947 948 -* AT Command: 898 +* (% style="color:#037691" %)AT Command: 949 949 950 950 (% class="box infomessage" %) 951 951 ((( ... ... @@ -962,7 +962,7 @@ 962 962 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 963 963 964 964 965 -* Downlink Payload (prefix 0x09 02 ): 915 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 02 ): 966 966 967 967 (% class="box infomessage" %) 968 968 ((( ... ... @@ -975,7 +975,7 @@ 975 975 976 976 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 977 977 978 -* AT Command: 928 +* (% style="color:#037691" %)AT Command: 979 979 980 980 (% class="box infomessage" %) 981 981 ((( ... ... @@ -983,7 +983,7 @@ 983 983 ))) 984 984 985 985 986 -* Downlink Payload (prefix 0xAA 01 ): 936 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 01 ): 987 987 988 988 (% class="box infomessage" %) 989 989 ((( ... ... @@ -996,7 +996,7 @@ 996 996 997 997 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 998 998 999 -* AT Command: 949 +* (% style="color:#037691" %)AT Command: 1000 1000 1001 1001 (% class="box infomessage" %) 1002 1002 ((( ... ... @@ -1004,7 +1004,7 @@ 1004 1004 ))) 1005 1005 1006 1006 1007 -* Downlink Payload (prefix 0xAA 00 ): 957 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 00 ): 1008 1008 1009 1009 (% class="box infomessage" %) 1010 1010 ((( ... ... @@ -1017,7 +1017,7 @@ 1017 1017 1018 1018 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 1019 1019 1020 -* AT Command: 970 +* (% style="color:#037691" %)AT Command: 1021 1021 1022 1022 (% class="box infomessage" %) 1023 1023 ((( ... ... @@ -1025,7 +1025,7 @@ 1025 1025 ))) 1026 1026 1027 1027 1028 -* Downlink Payload (prefix 0xAC ): 978 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAC ): 1029 1029 1030 1030 (% class="box infomessage" %) 1031 1031 ((( ... ... @@ -1036,12 +1036,12 @@ 1036 1036 1037 1037 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 1038 1038 1039 -* AT Command: 989 +* (% style="color:#037691" %)AT Command: 1040 1040 1041 1041 There is no AT Command to control Digital Output 1042 1042 1043 1043 1044 -* Downlink Payload (prefix 0x02): 994 +* (% style="color:#037691" %)Downlink Payload (prefix 0x02): 1045 1045 1046 1046 (% class="box infomessage" %) 1047 1047 ((( ... ... @@ -1070,12 +1070,12 @@ 1070 1070 1071 1071 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1072 1072 1073 -* AT Command: 1023 +* (% style="color:#037691" %)AT Command: 1074 1074 1075 1075 There is no AT Command to control Digital Output 1076 1076 1077 1077 1078 -* Downlink Payload (prefix 0xA9): 1028 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA9): 1079 1079 1080 1080 (% class="box infomessage" %) 1081 1081 ((( ... ... @@ -1139,12 +1139,12 @@ 1139 1139 1140 1140 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1141 1141 1142 -* AT Command: 1092 +* (% style="color:#037691" %)AT Command: 1143 1143 1144 1144 There is no AT Command to control Relay Output 1145 1145 1146 1146 1147 -* Downlink Payload (prefix 0x03): 1097 +* (% style="color:#037691" %)Downlink Payload (prefix 0x03): 1148 1148 1149 1149 (% class="box infomessage" %) 1150 1150 ((( ... ... @@ -1169,18 +1169,16 @@ 1169 1169 1170 1170 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1171 1171 1172 -* AT Command: 1122 +* (% style="color:#037691" %)AT Command: 1173 1173 1174 1174 There is no AT Command to control Relay Output 1175 1175 1176 1176 1177 -* Downlink Payload (prefix 0x05): 1127 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x05):** 1178 1178 1179 -(% class="box infomessage" %) 1180 -((( 1181 -**0x05 aa bb cc dd ~/~/ Set RO1/RO2 relay with time control:** 1182 -))) 1129 +**0x05 aa bb cc dd **~/~/ Set RO1/RO2 relay with time control 1183 1183 1131 + 1184 1184 This is to control the relay output time of relay. Include four bytes: 1185 1185 1186 1186 (% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05) ... ... @@ -1222,35 +1222,28 @@ 1222 1222 1223 1223 1224 1224 1173 + 1225 1225 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1226 1226 1227 1227 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1228 1228 1229 -* AT Command: 1178 +* (% style="color:#037691" %)**AT Command:** 1230 1230 1231 -(% class="box infomessage" %) 1232 -((( 1233 -**AT+VOLMAX ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]** 1234 -))) 1180 +(% style="color:#037691" %)****(%%)**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1235 1235 1236 1236 1237 -* Downlink Payload (prefix 0xA5): 1183 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** 1238 1238 1239 -(% class="box infomessage" %) 1240 -((( 1241 -**0xA5 aa bb cc ~/~/ Same as AT+VOLMAX=(aa bb),cc** 1242 -))) 1185 +**0xA5 aa bb cc **~/~/ Same as AT+VOLMAX=(aa bb),cc 1243 1243 1244 1244 1245 1245 1189 + 1246 1246 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1247 1247 1248 -* AT Command: 1192 +* (% style="color:#037691" %)**AT Command:** 1249 1249 1250 -(% class="box infomessage" %) 1251 -((( 1252 -**AT+SETCNT=aa,(bb cc dd ee) ** 1253 -))) 1194 +(% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) ** 1254 1254 1255 1255 aa: 1: Set count1, 1256 1256 ... ... @@ -1261,51 +1261,40 @@ 1261 1261 Bb cc dd ee: number to be set 1262 1262 1263 1263 1264 -* Downlink Payload (prefix 0xA8): 1205 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA8):** 1265 1265 1266 -(% class="box infomessage" %) 1267 -((( 1268 -**0x A8 aa bb cc dd ee ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)** 1269 -))) 1207 +**0x A8 aa bb cc dd ee **~/~/ same as AT+SETCNT=aa,(bb cc dd ee) 1270 1270 1271 1271 1272 1272 1211 + 1273 1273 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1274 1274 1275 1275 Clear counting for counting mode 1276 1276 1277 -* AT Command: 1216 +* (% style="color:#037691" %)**AT Command:** 1278 1278 1279 -(% class="box infomessage" %) 1280 -((( 1281 -**AT+CLRCOUNT ~/~/ clear all counting** 1282 -))) 1218 +(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1283 1283 1284 -* Downlink Payload (prefix 0xA6): 1285 1285 1286 -(% class="box infomessage" %) 1287 -((( 1288 -**0x A6 01 ~/~/ clear all counting,** 1289 -))) 1221 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** 1290 1290 1223 +**0x A6 01 ** ~/~/ clear all counting 1291 1291 1292 1292 1226 + 1227 + 1293 1293 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1294 1294 1295 -* AT Command: 1230 +* (% style="color:#037691" %)**AT Command:** 1296 1296 1297 -(% class="box infomessage" %) 1298 -((( 1299 -**AT+COUTIME=60 ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)** 1300 -))) 1232 +**AT+COUTIME=60 **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30) 1301 1301 1302 -* Downlink Payload (prefix 0xA7): 1303 1303 1304 -(% class="box infomessage" %) 1305 -((( 1306 -**0x A7 aa bb cc ~/~/ same as AT+COUTIME =aa bb cc,** 1307 -))) 1235 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA7):** 1308 1308 1237 +**0x A7 aa bb cc **~/~/ same as AT+COUTIME =aa bb cc, 1238 + 1309 1309 ((( 1310 1310 range: aa bb cc:0 to 16777215, (unit:second) 1311 1311 ... ... @@ -1313,6 +1313,7 @@ 1313 1313 ))) 1314 1314 1315 1315 1246 + 1316 1316 == 3.5 Integrate with Mydevice == 1317 1317 1318 1318 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: