From version < 82.1 >
edited by Bei Jinggeng
on 2022/06/15 08:49
To version < 80.1 >
edited by Xiaoling
on 2022/06/10 09:41
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Bei
1 +XWiki.Xiaoling
Content
... ... @@ -48,7 +48,6 @@
48 48  
49 49  )))
50 50  
51 -
52 52  == 1.2  Specifications ==
53 53  
54 54  (((
... ... @@ -165,7 +165,6 @@
165 165  Packet engine up to 256 bytes with CRC.
166 166  )))
167 167  
168 -
169 169  == 1.3 Features ==
170 170  
171 171  * LoRaWAN Class A & Class C protocol
... ... @@ -176,7 +176,6 @@
176 176  * Firmware upgradable via program port
177 177  * Counting
178 178  
179 -
180 180  == 1.4  Applications ==
181 181  
182 182  * Smart Buildings & Home Automation
... ... @@ -186,7 +186,6 @@
186 186  * Smart Cities
187 187  * Smart Factory
188 188  
189 -
190 190  == 1.5 Hardware Variants ==
191 191  
192 192  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -200,7 +200,6 @@
200 200  * 1 x Counting Port
201 201  )))
202 202  
203 -
204 204  = 2. Power ON Device =
205 205  
206 206  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -319,6 +319,7 @@
319 319  * [1] RO1 relay channel is close and the RO1 LED is ON.
320 320  * [0] RO2 relay channel is open and RO2 LED is OFF;
321 321  
317 +
322 322  **LT22222-L:**
323 323  
324 324  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -771,6 +771,8 @@
771 771  
772 772  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
773 773  
770 +
771 +
774 774  === 3.4.1 Common Commands ===
775 775  
776 776  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -2002,16 +2002,8 @@
2002 2002  )))
2003 2003  
2004 2004  (((
2005 -== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? ==
2003 +
2006 2006  
2007 -If the device is not shut down, but directly powered off.
2008 -
2009 -It will default that this is a power-off state.
2010 -
2011 -In modes 2 to 5, DO RO status and pulse count are saved in flash.
2012 -
2013 -After restart, the status before power failure will be read from flash.
2014 -
2015 2015  = 6. Trouble Shooting =
2016 2016  )))
2017 2017  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0