From version < 82.1 >
edited by Bei Jinggeng
on 2022/06/15 08:49
To version < 79.2 >
edited by Xiaoling
on 2022/06/10 09:40
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Bei
1 +XWiki.Xiaoling
Content
... ... @@ -48,7 +48,6 @@
48 48  
49 49  )))
50 50  
51 -
52 52  == 1.2  Specifications ==
53 53  
54 54  (((
... ... @@ -165,7 +165,6 @@
165 165  Packet engine up to 256 bytes with CRC.
166 166  )))
167 167  
168 -
169 169  == 1.3 Features ==
170 170  
171 171  * LoRaWAN Class A & Class C protocol
... ... @@ -176,7 +176,6 @@
176 176  * Firmware upgradable via program port
177 177  * Counting
178 178  
179 -
180 180  == 1.4  Applications ==
181 181  
182 182  * Smart Buildings & Home Automation
... ... @@ -186,7 +186,6 @@
186 186  * Smart Cities
187 187  * Smart Factory
188 188  
189 -
190 190  == 1.5 Hardware Variants ==
191 191  
192 192  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -200,7 +200,6 @@
200 200  * 1 x Counting Port
201 201  )))
202 202  
203 -
204 204  = 2. Power ON Device =
205 205  
206 206  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -281,6 +281,7 @@
281 281  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
282 282  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
283 283  
279 +
284 284  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
285 285  
286 286  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -319,6 +319,8 @@
319 319  * [1] RO1 relay channel is close and the RO1 LED is ON.
320 320  * [0] RO2 relay channel is open and RO2 LED is OFF;
321 321  
318 +
319 +
322 322  **LT22222-L:**
323 323  
324 324  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -334,6 +334,7 @@
334 334  ** DO1 is high in case there is load between DO1 and V+.
335 335  ** DO1 LED is off in both case
336 336  
335 +
337 337  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
338 338  
339 339  
... ... @@ -474,6 +474,8 @@
474 474  
475 475  (((
476 476  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
476 +
477 +
477 477  )))
478 478  
479 479  
... ... @@ -759,6 +759,7 @@
759 759  )))
760 760  
761 761  
763 +
762 762  == 3.4 ​Configure LT via AT or Downlink ==
763 763  
764 764  User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands
... ... @@ -2002,16 +2002,8 @@
2002 2002  )))
2003 2003  
2004 2004  (((
2005 -== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? ==
2007 +
2006 2006  
2007 -If the device is not shut down, but directly powered off.
2008 -
2009 -It will default that this is a power-off state.
2010 -
2011 -In modes 2 to 5, DO RO status and pulse count are saved in flash.
2012 -
2013 -After restart, the status before power failure will be read from flash.
2014 -
2015 2015  = 6. Trouble Shooting =
2016 2016  )))
2017 2017  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0