Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -19,6 +19,8 @@ 19 19 == 1.1 What is LT Series I/O Controller == 20 20 21 21 ((( 22 + 23 + 22 22 The Dragino (% style="color:blue" %)**LT series I/O Modules**(%%) are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (% style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %), **relay output**, **digital input**(%%) and (% style="color:blue" %)**digital output**(%%) etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring. 23 23 ))) 24 24 ... ... @@ -163,10 +163,12 @@ 163 163 ))) 164 164 * ((( 165 165 Packet engine up to 256 bytes with CRC. 166 -))) 167 167 168 168 169 169 171 + 172 +))) 173 + 170 170 == 1.3 Features == 171 171 172 172 * LoRaWAN Class A & Class C protocol ... ... @@ -179,6 +179,7 @@ 179 179 180 180 181 181 186 + 182 182 == 1.4 Applications == 183 183 184 184 * Smart Buildings & Home Automation ... ... @@ -190,6 +190,7 @@ 190 190 191 191 192 192 198 + 193 193 == 1.5 Hardware Variants == 194 194 195 195 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -285,6 +285,9 @@ 285 285 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 286 286 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 287 287 294 + 295 + 296 + 288 288 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 289 289 290 290 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -323,6 +323,7 @@ 323 323 * [1] RO1 relay channel is close and the RO1 LED is ON. 324 324 * [0] RO2 relay channel is open and RO2 LED is OFF; 325 325 335 + 326 326 **LT22222-L:** 327 327 328 328 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -338,6 +338,9 @@ 338 338 ** DO1 is high in case there is load between DO1 and V+. 339 339 ** DO1 LED is off in both case 340 340 351 + 352 + 353 + 341 341 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 342 342 343 343 ... ... @@ -2006,8 +2006,16 @@ 2006 2006 ))) 2007 2007 2008 2008 ((( 2009 - 2022 +== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? == 2010 2010 2024 +If the device is not shut down, but directly powered off. 2025 + 2026 +It will default that this is a power-off state. 2027 + 2028 +In modes 2 to 5, DO RO status and pulse count are saved in flash. 2029 + 2030 +After restart, the status before power failure will be read from flash. 2031 + 2011 2011 = 6. Trouble Shooting = 2012 2012 ))) 2013 2013