Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -19,6 +19,8 @@ 19 19 == 1.1 What is LT Series I/O Controller == 20 20 21 21 ((( 22 + 23 + 22 22 The Dragino (% style="color:blue" %)**LT series I/O Modules**(%%) are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (% style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %), **relay output**, **digital input**(%%) and (% style="color:blue" %)**digital output**(%%) etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring. 23 23 ))) 24 24 ... ... @@ -48,6 +48,7 @@ 48 48 49 49 ))) 50 50 53 + 51 51 == 1.2 Specifications == 52 52 53 53 ((( ... ... @@ -162,6 +162,10 @@ 162 162 ))) 163 163 * ((( 164 164 Packet engine up to 256 bytes with CRC. 168 + 169 + 170 + 171 + 165 165 ))) 166 166 167 167 == 1.3 Features == ... ... @@ -174,6 +174,8 @@ 174 174 * Firmware upgradable via program port 175 175 * Counting 176 176 184 + 185 + 177 177 == 1.4 Applications == 178 178 179 179 * Smart Buildings & Home Automation ... ... @@ -183,6 +183,8 @@ 183 183 * Smart Cities 184 184 * Smart Factory 185 185 195 + 196 + 186 186 == 1.5 Hardware Variants == 187 187 188 188 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -196,6 +196,7 @@ 196 196 * 1 x Counting Port 197 197 ))) 198 198 210 + 199 199 = 2. Power ON Device = 200 200 201 201 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -276,6 +276,8 @@ 276 276 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 277 277 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 278 278 291 + 292 + 279 279 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 280 280 281 281 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -314,7 +314,6 @@ 314 314 * [1] RO1 relay channel is close and the RO1 LED is ON. 315 315 * [0] RO2 relay channel is open and RO2 LED is OFF; 316 316 317 - 318 318 **LT22222-L:** 319 319 320 320 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -330,6 +330,8 @@ 330 330 ** DO1 is high in case there is load between DO1 and V+. 331 331 ** DO1 LED is off in both case 332 332 346 + 347 + 333 333 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 334 334 335 335 ... ... @@ -366,12 +366,7 @@ 366 366 ((( 367 367 ((( 368 368 **AT+MOD=2** 369 -))) 370 -))) 371 371 372 -(% class="box infomessage" %) 373 -((( 374 -((( 375 375 **ATZ** 376 376 ))) 377 377 ))) ... ... @@ -390,40 +390,15 @@ 390 390 ((( 391 391 ((( 392 392 **AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 393 -))) 394 -))) 395 395 396 -(% class="box infomessage" %) 397 -((( 398 -((( 399 399 **AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 400 -))) 401 -))) 402 402 403 -(% class="box infomessage" %) 404 -((( 405 -((( 406 406 **AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 407 -))) 408 -))) 409 409 410 -(% class="box infomessage" %) 411 -((( 412 -((( 413 413 **AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 414 -))) 415 -))) 416 416 417 -(% class="box infomessage" %) 418 -((( 419 -((( 420 420 **AT+SETCNT=1,60 (Set COUNT1 value to 60)** 421 -))) 422 -))) 423 423 424 -(% class="box infomessage" %) 425 -((( 426 -((( 427 427 **AT+SETCNT=2,60 (Set COUNT2 value to 60)** 428 428 ))) 429 429 ))) ... ... @@ -458,12 +458,7 @@ 458 458 ((( 459 459 ((( 460 460 **AT+MOD=3** 461 -))) 462 -))) 463 463 464 -(% class="box infomessage" %) 465 -((( 466 -((( 467 467 **ATZ** 468 468 ))) 469 469 ))) ... ... @@ -508,20 +508,13 @@ 508 508 ((( 509 509 ((( 510 510 **AT+MOD=4** 511 -))) 512 -))) 513 513 514 -(% class="box infomessage" %) 515 -((( 516 -((( 517 517 **ATZ** 518 518 ))) 519 519 ))) 520 520 521 -((( 522 - 523 -))) 524 524 497 + 525 525 ((( 526 526 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 527 527 ))) ... ... @@ -535,33 +535,17 @@ 535 535 (% class="box infomessage" %) 536 536 ((( 537 537 ((( 538 -**AT+SETCNT=3,60 (set AVI Count to 60)** 539 -))) 540 -))) 511 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 541 541 542 -(% class="box infomessage" %) 543 -((( 544 -((( 545 -**AT+VOLMAX=20000 (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 546 -))) 547 -))) 513 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 548 548 549 -(% class="box infomessage" %) 550 -((( 551 -((( 552 -**AT+VOLMAX=20000,0 (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 553 -))) 554 -))) 515 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 555 555 556 -(% class="box infomessage" %) 557 -((( 558 -((( 559 -**AT+VOLMAX=20000,1 (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 517 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 560 560 ))) 561 561 ))) 562 562 563 563 564 - 565 565 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 566 566 567 567 ... ... @@ -595,12 +595,7 @@ 595 595 ((( 596 596 ((( 597 597 **AT+MOD=5** 598 -))) 599 -))) 600 600 601 -(% class="box infomessage" %) 602 -((( 603 -((( 604 604 **ATZ** 605 605 ))) 606 606 ))) ... ... @@ -626,7 +626,7 @@ 626 626 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 627 627 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 628 628 629 -**AT Command to set Trigger Condition**: 581 +(% style="color:#037691" %)**AT Command to set Trigger Condition**: 630 630 631 631 (% style="color:#4f81bd" %)**Trigger base on voltage**: 632 632 ... ... @@ -662,7 +662,7 @@ 662 662 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 663 663 664 664 665 -**Downlink Command to set Trigger Condition:** 617 +(% style="color:#037691" %)**Downlink Command to set Trigger Condition:** 666 666 667 667 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 668 668 ... ... @@ -781,7 +781,7 @@ 781 781 782 782 Set device uplink interval. 783 783 784 -* AT Command: 736 +* (% style="color:#037691" %)**AT Command:** 785 785 786 786 (% class="box infomessage" %) 787 787 ((( ... ... @@ -791,7 +791,7 @@ 791 791 **Example: **AT+TDC=30000. Means set interval to 30 seconds 792 792 793 793 794 -* Downlink Payload (prefix 0x01): 746 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 795 795 796 796 (% class="box infomessage" %) 797 797 ((( ... ... @@ -804,7 +804,7 @@ 804 804 805 805 Set work mode. 806 806 807 -* AT Command: 759 +* (% style="color:#037691" %)**AT Command:** 808 808 809 809 (% class="box infomessage" %) 810 810 ((( ... ... @@ -814,7 +814,7 @@ 814 814 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 815 815 816 816 817 -* Downlink Payload (prefix 0x0A): 769 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 818 818 819 819 (% class="box infomessage" %) 820 820 ((( ... ... @@ -825,12 +825,12 @@ 825 825 826 826 ==== 3.4.2.3 Poll an uplink ==== 827 827 828 -* AT Command: 780 +* (% style="color:#037691" %)AT Command: 829 829 830 830 There is no AT Command to poll uplink 831 831 832 832 833 -* Downlink Payload (prefix 0x08): 785 +* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 834 834 835 835 (% class="box infomessage" %) 836 836 ((( ... ... @@ -845,7 +845,7 @@ 845 845 846 846 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 847 847 848 -* AT Command: 800 +* (% style="color:#037691" %)AT Command: 849 849 850 850 (% class="box infomessage" %) 851 851 ((( ... ... @@ -857,7 +857,7 @@ 857 857 0: Disable Trigger Mode 858 858 859 859 860 -* Downlink Payload (prefix 0x0A 06): 812 +* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 861 861 862 862 (% class="box infomessage" %) 863 863 ((( ... ... @@ -870,12 +870,12 @@ 870 870 871 871 Poll trigger settings, 872 872 873 -* AT Command: 825 +* (% style="color:#037691" %)AT Command: 874 874 875 875 There is no AT Command for this feature. 876 876 877 877 878 -* Downlink Payload (prefix 0x AB 06): 830 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 879 879 880 880 (% class="box infomessage" %) 881 881 ((( ... ... @@ -888,7 +888,7 @@ 888 888 889 889 Enable Disable DI1/DI2/DI2 as trigger, 890 890 891 -* AT Command: 843 +* (% style="color:#037691" %)AT Command: 892 892 893 893 (% class="box infomessage" %) 894 894 ((( ... ... @@ -900,25 +900,20 @@ 900 900 901 901 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 902 902 903 -* Downlink Payload (prefix 0xAA 02): 855 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 904 904 905 -(% class="box infomessage" %) 906 -((( 907 -**0xAA 02 aa bb ~/~/ Same as AT+DTRI=aa,bb** 908 -))) 857 +**0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 909 909 910 910 911 911 861 + 912 912 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 913 913 914 914 Set DI1 or DI3(for LT-33222-L) trigger. 915 915 916 -* AT Command: 866 +* (% style="color:#037691" %)AT Command: 917 917 918 -(% class="box infomessage" %) 919 -((( 920 920 **AT+TRIG1=a,b** 921 -))) 922 922 923 923 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 924 924 ... ... @@ -930,12 +930,9 @@ 930 930 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 931 931 932 932 933 -* Downlink Payload (prefix 0x09 01 ): 880 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 881 +* **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 934 934 935 -(% class="box infomessage" %) 936 -((( 937 -**0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 938 -))) 939 939 940 940 941 941 ... ... @@ -943,13 +943,11 @@ 943 943 944 944 Set DI2 trigger. 945 945 946 -* AT Command: 890 +* (% style="color:#037691" %)**AT Command:** 947 947 948 -(% class="box infomessage" %) 949 -((( 950 950 **AT+TRIG2=a,b** 951 -))) 952 952 894 + 953 953 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 954 954 955 955 b : delay timing. ... ... @@ -960,91 +960,71 @@ 960 960 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 961 961 962 962 963 -* Downlink Payload (prefix 0x09 02 ): 905 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):** 964 964 965 -(% class="box infomessage" %) 966 -((( 967 -**0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 968 -))) 907 +**0x09 02 aa bb cc **~/~/ same as AT+TRIG1=aa,0x(bb cc) 969 969 970 970 971 971 911 + 972 972 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 973 973 974 974 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 975 975 976 -* AT Command :916 +* (% style="color:#037691" %)**AT Command** 977 977 978 -(% class="box infomessage" %) 979 -((( 980 -**AT+ACLIM. ** 981 -))) 918 +**AT+ACLIM** 982 982 983 983 984 -* Downlink Payload (prefix 0xAA 01 ) :921 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )** 985 985 986 -(% class="box infomessage" %) 987 -((( 988 -**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 989 -))) 923 +**0x AA 01 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 990 990 991 991 992 992 927 + 993 993 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 994 994 995 995 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 996 996 997 -* AT Command :932 +* (% style="color:#037691" %)**AT Command** 998 998 999 -(% class="box infomessage" %) 1000 -((( 1001 -**AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 1002 -))) 934 +**AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 1003 1003 1004 1004 1005 -* Downlink Payload (prefix 0xAA 00 ) :937 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )** 1006 1006 1007 -(% class="box infomessage" %) 1008 -((( 1009 -**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ** 1010 -))) 939 +**0x AA 00 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 1011 1011 1012 1012 1013 1013 943 + 1014 1014 ==== 3.4.2.11 Trigger – Set minimum interval ==== 1015 1015 1016 1016 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 1017 1017 1018 -* AT Command :948 +* (% style="color:#037691" %)**AT Command** 1019 1019 1020 -(% class="box infomessage" %) 1021 -((( 1022 1022 **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.** 1023 -))) 1024 1024 1025 1025 1026 -* Downlink Payload (prefix 0xAC ) :953 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** 1027 1027 1028 -(% class="box infomessage" %) 1029 -((( 1030 -**0x AC aa bb ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min)** 1031 -))) 955 +**0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 1032 1032 1033 1033 1034 1034 959 + 1035 1035 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 1036 1036 1037 -* AT Command :962 +* (% style="color:#037691" %)**AT Command** 1038 1038 1039 1039 There is no AT Command to control Digital Output 1040 1040 1041 1041 1042 -* Downlink Payload (prefix 0x02): 967 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x02)** 968 +* **0x02 aa bb cc **~/~/ Set DO1/DO2/DO3 output 1043 1043 1044 -(% class="box infomessage" %) 1045 -((( 1046 -**0x02 aa bb cc ~/~/ Set DO1/DO2/DO3 output** 1047 -))) 1048 1048 1049 1049 ((( 1050 1050 If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low. ... ... @@ -1066,22 +1066,19 @@ 1066 1066 1067 1067 1068 1068 991 + 1069 1069 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1070 1070 1071 -* AT Command :994 +* (% style="color:#037691" %)**AT Command** 1072 1072 1073 1073 There is no AT Command to control Digital Output 1074 1074 1075 1075 1076 -* Downlink Payload (prefix 0xA9) :999 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA9)** 1077 1077 1078 -(% class="box infomessage" %) 1079 -((( 1080 -((( 1081 -**0xA9 aa bb cc ~/~/ Set DO1/DO2/DO3 output with time control** 1082 -))) 1083 -))) 1001 +**0xA9 aa bb cc **~/~/ Set DO1/DO2/DO3 output with time control 1084 1084 1003 + 1085 1085 This is to control the digital output time of DO pin. Include four bytes: 1086 1086 1087 1087 (% style="color:#4f81bd" %)**First Byte**(%%)**:** Type code (0xA9) ... ... @@ -1135,20 +1135,19 @@ 1135 1135 1136 1136 1137 1137 1057 + 1138 1138 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1139 1139 1140 -* AT Command: 1060 +* (% style="color:#037691" %)**AT Command:** 1141 1141 1142 1142 There is no AT Command to control Relay Output 1143 1143 1144 1144 1145 -* Downlink Payload (prefix 0x03): 1065 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x03):** 1146 1146 1147 -(% class="box infomessage" %) 1148 -((( 1149 -**0x03 aa bb ~/~/ Set RO1/RO2 output** 1150 -))) 1067 +**0x03 aa bb **~/~/ Set RO1/RO2 output 1151 1151 1069 + 1152 1152 ((( 1153 1153 If payload = 0x030100, it means set RO1 to close and RO2 to open. 1154 1154 ))) ... ... @@ -1165,20 +1165,19 @@ 1165 1165 1166 1166 1167 1167 1086 + 1168 1168 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1169 1169 1170 -* AT Command: 1089 +* (% style="color:#037691" %)**AT Command:** 1171 1171 1172 1172 There is no AT Command to control Relay Output 1173 1173 1174 1174 1175 -* Downlink Payload (prefix 0x05): 1094 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x05):** 1176 1176 1177 -(% class="box infomessage" %) 1178 -((( 1179 -**0x05 aa bb cc dd ~/~/ Set RO1/RO2 relay with time control:** 1180 -))) 1096 +**0x05 aa bb cc dd **~/~/ Set RO1/RO2 relay with time control 1181 1181 1098 + 1182 1182 This is to control the relay output time of relay. Include four bytes: 1183 1183 1184 1184 (% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05) ... ... @@ -1220,35 +1220,28 @@ 1220 1220 1221 1221 1222 1222 1140 + 1223 1223 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1224 1224 1225 1225 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1226 1226 1227 -* AT Command: 1145 +* (% style="color:#037691" %)**AT Command:** 1228 1228 1229 -(% class="box infomessage" %) 1230 -((( 1231 -**AT+VOLMAX ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]** 1232 -))) 1147 +(% style="color:#037691" %)****(%%)**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1233 1233 1234 1234 1235 -* Downlink Payload (prefix 0xA5): 1150 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** 1236 1236 1237 -(% class="box infomessage" %) 1238 -((( 1239 -**0xA5 aa bb cc ~/~/ Same as AT+VOLMAX=(aa bb),cc** 1240 -))) 1152 +**0xA5 aa bb cc **~/~/ Same as AT+VOLMAX=(aa bb),cc 1241 1241 1242 1242 1243 1243 1156 + 1244 1244 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1245 1245 1246 -* AT Command: 1159 +* (% style="color:#037691" %)**AT Command:** 1247 1247 1248 -(% class="box infomessage" %) 1249 -((( 1250 -**AT+SETCNT=aa,(bb cc dd ee) ** 1251 -))) 1161 +(% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) ** 1252 1252 1253 1253 aa: 1: Set count1, 1254 1254 ... ... @@ -1259,51 +1259,40 @@ 1259 1259 Bb cc dd ee: number to be set 1260 1260 1261 1261 1262 -* Downlink Payload (prefix 0xA8): 1172 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA8):** 1263 1263 1264 -(% class="box infomessage" %) 1265 -((( 1266 -**0x A8 aa bb cc dd ee ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)** 1267 -))) 1174 +**0x A8 aa bb cc dd ee **~/~/ same as AT+SETCNT=aa,(bb cc dd ee) 1268 1268 1269 1269 1270 1270 1178 + 1271 1271 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1272 1272 1273 1273 Clear counting for counting mode 1274 1274 1275 -* AT Command: 1183 +* (% style="color:#037691" %)**AT Command:** 1276 1276 1277 -(% class="box infomessage" %) 1278 -((( 1279 -**AT+CLRCOUNT ~/~/ clear all counting** 1280 -))) 1185 +(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1281 1281 1282 -* Downlink Payload (prefix 0xA6): 1283 1283 1284 -(% class="box infomessage" %) 1285 -((( 1286 -**0x A6 01 ~/~/ clear all counting,** 1287 -))) 1188 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** 1288 1288 1190 +**0x A6 01 ** ~/~/ clear all counting 1289 1289 1290 1290 1193 + 1194 + 1291 1291 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1292 1292 1293 -* AT Command: 1197 +* (% style="color:#037691" %)**AT Command:** 1294 1294 1295 -(% class="box infomessage" %) 1296 -((( 1297 -**AT+COUTIME=60 ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)** 1298 -))) 1199 +**AT+COUTIME=60 **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30) 1299 1299 1300 -* Downlink Payload (prefix 0xA7): 1301 1301 1302 -(% class="box infomessage" %) 1303 -((( 1304 -**0x A7 aa bb cc ~/~/ same as AT+COUTIME =aa bb cc,** 1305 -))) 1202 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA7):** 1306 1306 1204 +**0x A7 aa bb cc **~/~/ same as AT+COUTIME =aa bb cc, 1205 + 1307 1307 ((( 1308 1308 range: aa bb cc:0 to 16777215, (unit:second) 1309 1309 ... ... @@ -1311,6 +1311,7 @@ 1311 1311 ))) 1312 1312 1313 1313 1213 + 1314 1314 == 3.5 Integrate with Mydevice == 1315 1315 1316 1316 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: ... ... @@ -2000,8 +2000,16 @@ 2000 2000 ))) 2001 2001 2002 2002 ((( 2003 - 1903 +== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? == 2004 2004 1905 +If the device is not shut down, but directly powered off. 1906 + 1907 +It will default that this is a power-off state. 1908 + 1909 +In modes 2 to 5, DO RO status and pulse count are saved in flash. 1910 + 1911 +After restart, the status before power failure will be read from flash. 1912 + 2005 2005 = 6. Trouble Shooting = 2006 2006 ))) 2007 2007