From version < 79.4 >
edited by Xiaoling
on 2022/06/10 09:41
To version < 82.1 >
edited by Bei Jinggeng
on 2022/06/15 08:49
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Bei
Content
... ... @@ -48,6 +48,7 @@
48 48  
49 49  )))
50 50  
51 +
51 51  == 1.2  Specifications ==
52 52  
53 53  (((
... ... @@ -164,6 +164,7 @@
164 164  Packet engine up to 256 bytes with CRC.
165 165  )))
166 166  
168 +
167 167  == 1.3 Features ==
168 168  
169 169  * LoRaWAN Class A & Class C protocol
... ... @@ -174,6 +174,7 @@
174 174  * Firmware upgradable via program port
175 175  * Counting
176 176  
179 +
177 177  == 1.4  Applications ==
178 178  
179 179  * Smart Buildings & Home Automation
... ... @@ -183,6 +183,7 @@
183 183  * Smart Cities
184 184  * Smart Factory
185 185  
189 +
186 186  == 1.5 Hardware Variants ==
187 187  
188 188  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -196,6 +196,7 @@
196 196  * 1 x Counting Port
197 197  )))
198 198  
203 +
199 199  = 2. Power ON Device =
200 200  
201 201  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -276,7 +276,6 @@
276 276  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
277 277  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
278 278  
279 -
280 280  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
281 281  
282 282  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -315,8 +315,6 @@
315 315  * [1] RO1 relay channel is close and the RO1 LED is ON.
316 316  * [0] RO2 relay channel is open and RO2 LED is OFF;
317 317  
318 -
319 -
320 320  **LT22222-L:**
321 321  
322 322  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -332,7 +332,6 @@
332 332  ** DO1 is high in case there is load between DO1 and V+.
333 333  ** DO1 LED is off in both case
334 334  
335 -
336 336  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
337 337  
338 338  
... ... @@ -770,9 +770,6 @@
770 770  
771 771  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
772 772  
773 -
774 -
775 -
776 776  === 3.4.1 Common Commands ===
777 777  
778 778  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -2004,8 +2004,16 @@
2004 2004  )))
2005 2005  
2006 2006  (((
2007 -
2005 +== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? ==
2008 2008  
2007 +If the device is not shut down, but directly powered off.
2008 +
2009 +It will default that this is a power-off state.
2010 +
2011 +In modes 2 to 5, DO RO status and pulse count are saved in flash.
2012 +
2013 +After restart, the status before power failure will be read from flash.
2014 +
2009 2009  = 6. Trouble Shooting =
2010 2010  )))