... ... @@ -1,7 +1,6 @@
1 1  (% style="text-align:center" %)
2 2  [[image:image-20220523163353-1.jpeg||height="604" width="500"]]
3 3  
4 -**LT-22222-L LoRa IO Controller User Manual **
5 5  
6 6  
7 7  **Table of Contents:**
... ... @@ -16,9 +16,12 @@
16 16  
17 17  = 1.Introduction =
18 18  
18 +
19 19  == 1.1 What is LT Series I/O Controller ==
20 20  
21 21  (((
22 +
23 +
22 22  The Dragino (% style="color:blue" %)**LT series I/O Modules**(%%) are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (% style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %), **relay output**, **digital input**(%%) and (% style="color:blue" %)**digital output**(%%) etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring.
23 23  )))
24 24  
... ... @@ -35,11 +35,13 @@
35 35  )))
36 36  
37 37  (((
38 -1) If users area has LoRaWAN service coverage, they can just install the I/O controller and configure it to connect the LoRaWAN provider via wireless.
40 +1) If user's area has LoRaWAN service coverage, they can just install the I/O controller and configure it to connect the LoRaWAN provider via wireless.
39 39  )))
40 40  
41 41  (((
42 42  2) User can set up a LoRaWAN gateway locally and configure the controller to connect to the gateway via wireless.
45 +
46 +
43 43  )))
44 44  
45 45  (((
... ... @@ -48,12 +48,13 @@
48 48  
49 49  )))
50 50  
55 +
51 51  == 1.2  Specifications ==
52 52  
53 53  (((
54 54  
55 55  
56 -**Hardware System:**
61 +(% style="color:#037691" %)**Hardware System:**
57 57  )))
58 58  
59 59  * (((
... ... @@ -78,7 +78,7 @@
78 78  (((
79 79  
80 80  
81 -**Interface for Model: LT22222-L:**
86 +(% style="color:#037691" %)**Interface for Model: LT22222-L:**
82 82  )))
83 83  
84 84  * (((
... ... @@ -103,7 +103,7 @@
103 103  (((
104 104  
105 105  
106 -**LoRa Spec:**
111 +(% style="color:#037691" %)**LoRa Spec:**
107 107  )))
108 108  
109 109  * (((
... ... @@ -162,20 +162,29 @@
162 162  )))
163 163  * (((
164 164  Packet engine up to 256 bytes with CRC.
170 +
171 +
172 +
173 +
165 165  )))
166 166  
167 167  == 1.3 Features ==
168 168  
178 +
169 169  * LoRaWAN Class A & Class C protocol
170 170  * Optional Customized LoRa Protocol
171 -* Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865
181 +* Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865/MA869
172 172  * AT Commands to change parameters
173 173  * Remote configure parameters via LoRa Downlink
174 174  * Firmware upgradable via program port
175 175  * Counting
176 176  
187 +
188 +
189 +
177 177  == 1.4  Applications ==
178 178  
192 +
179 179  * Smart Buildings & Home Automation
180 180  * Logistics and Supply Chain Management
181 181  * Smart Metering
... ... @@ -183,8 +183,12 @@
183 183  * Smart Cities
184 184  * Smart Factory
185 185  
200 +
201 +
202 +
186 186  == 1.5 Hardware Variants ==
187 187  
205 +
188 188  (% border="1" style="background-color:#f7faff; width:500px" %)
189 189  |(% style="width:103px" %)**Model**|(% style="width:131px" %)**Photo**|(% style="width:334px" %)**Description**
190 190  |(% style="width:103px" %)**LT22222-L**|(% style="width:131px" %)[[image:1653296302983-697.png]]|(% style="width:334px" %)(((
... ... @@ -196,12 +196,18 @@
196 196  * 1 x Counting Port
197 197  )))
198 198  
217 +
218 +
219 +
199 199  = 2. Power ON Device =
200 200  
222 +
201 201  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
202 202  
203 203  (((
204 204  PWR will on when device is properly powered.
227 +
228 +
205 205  )))
206 206  
207 207  [[image:1653297104069-180.png]]
... ... @@ -210,21 +210,27 @@
210 210  
211 211  = 3. Operation Mode =
212 212  
237 +
213 213  == 3.1 How it works? ==
214 214  
240 +
215 215  (((
216 -The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on **TX LED** will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. **TX LED** will be on for 5 seconds after joined in network. When there is message from server, the **RX LED** will be on for 1 second. 
242 +The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%) will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. (% style="color:green" %)**TX LED**(%%) will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second. 
217 217  )))
218 218  
219 219  (((
220 -In case user cant set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.
246 +In case user can't set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.
221 221  )))
222 222  
223 223  
250 +
224 224  == 3.2 Example to join LoRaWAN network ==
225 225  
253 +
226 226  (((
227 227  This chapter shows an example for how to join the TTN LoRaWAN Network. Below is the network structure, we use our LG308 as LoRaWAN gateway here. 
256 +
257 +
228 228  )))
229 229  
230 230  [[image:image-20220523172350-1.png||height="266" width="864"]]
... ... @@ -232,6 +232,8 @@
232 232  
233 233  (((
234 234  The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN:
265 +
266 +
235 235  )))
236 236  
237 237  (((
... ... @@ -257,6 +257,7 @@
257 257  [[image:1653298023685-319.png]]
258 258  
259 259  
292 +
260 260  (((
261 261  (% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
262 262  )))
... ... @@ -267,18 +267,22 @@
267 267  
268 268  == 3.3 Uplink Payload ==
269 269  
303 +
270 270  There are five working modes + one interrupt mode on LT for different type application:
271 271  
272 -* **MOD1**: (default setting): 2 x ACI + 2AVI + DI + DO + RO
273 -* **MOD2**: Double DI Counting + DO + RO
274 -* **MOD3**: Single DI Counting + 2 x ACI + DO + RO
275 -* **MOD4**: Single DI Counting + 1 x Voltage Counting + DO + RO
276 -* **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
277 -* **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
306 +* (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO
307 +* (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO
308 +* (% style="color:blue" %)**MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO
309 +* (% style="color:blue" %)**MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO
310 +* (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
311 +* (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
278 278  
279 279  
314 +
315 +
280 280  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
281 281  
318 +
282 282  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
283 283  
284 284  [[image:image-20220523174024-3.png]]
... ... @@ -295,8 +295,10 @@
295 295  * DI is for digital input. DIx=1: high or float, DIx=0: low.
296 296  * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
297 297  
298 -(% style="color:red" %)Note: DI3 and DO3 bit are not valid for LT-22222-L
299 299  
336 +
337 +(% style="color:red" %)**Note: DI3 and DO3 bit are not valid for LT-22222-L**
338 +
300 300  For example if payload is: [[image:image-20220523175847-2.png]]
301 301  
302 302  
... ... @@ -333,6 +333,9 @@
333 333  ** DO1 LED is off in both case
334 334  
335 335  
375 +
376 +
377 +
336 336  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
337 337  
338 338  
... ... @@ -356,7 +356,7 @@
356 356  * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
357 357  
358 358  (((
359 -(% style="color:red" %)Note: DO3 bit is not valid for LT-22222-L.
401 +(% style="color:red" %)**Note: DO3 bit is not valid for LT-22222-L.**
360 360  )))
361 361  
362 362  (((
... ... @@ -369,12 +369,7 @@
369 369  (((
370 370  (((
371 371  **AT+MOD=2**
372 -)))
373 -)))
374 374  
375 -(% class="box infomessage" %)
376 -(((
377 -(((
378 378  **ATZ**
379 379  )))
380 380  )))
... ... @@ -383,63 +383,39 @@
383 383  
384 384  
385 385  (% style="color:#4f81bd" %)**AT Commands for counting:**
423 +
424 +
386 386  )))
387 387  
388 388  (((
389 389  **For LT22222-L:**
390 -)))
391 391  
392 -(% class="box infomessage" %)
393 -(((
394 -(((
395 -**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) **
396 -)))
397 -)))
398 398  
399 -(% class="box infomessage" %)
400 -(((
401 -(((
402 -**AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) **
403 -)))
404 -)))
431 +(% style="color:blue" %)**AT+TRIG1=0,100**(%%)**  (set DI1 port to trigger on low level, valid signal is 100ms) **
405 405  
406 -(% class="box infomessage" %)
407 -(((
408 -(((
409 -**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) **
410 -)))
411 -)))
433 +(% style="color:blue" %)**AT+TRIG1=1,100**(%%)**  (set DI1 port to trigger on high level, valid signal is 100ms ) **
412 412  
413 -(% class="box infomessage" %)
414 -(((
415 -(((
416 -**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) **
417 -)))
418 -)))
435 +(% style="color:blue" %)**AT+TRIG2=0,100**(%%)**  (set DI2 port to trigger on low level, valid signal is 100ms) **
419 419  
420 -(% class="box infomessage" %)
421 -(((
422 -(((
423 -**AT+SETCNT=1,60   (Set COUNT1 value to 60)**
424 -)))
425 -)))
437 +(% style="color:blue" %)**AT+TRIG2=1,100**(%%)**  (set DI2 port to trigger on high level, valid signal is 100ms ) **
426 426  
427 -(% class="box infomessage" %)
428 -(((
429 -(((
430 -**AT+SETCNT=2,60   (Set COUNT2 value to 60)**
439 +(% style="color:blue" %)**AT+SETCNT=1,60**(%%)**   (Set COUNT1 value to 60)**
440 +
441 +(% style="color:blue" %)**AT+SETCNT=2,60**(%%)**   (Set COUNT2 value to 60)**
431 431  )))
432 -)))
433 433  
434 434  
435 435  
436 436  === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI ===
437 437  
448 +
438 438  **LT22222-L**: This mode the DI1 is used as a counting pin.
439 439  
440 440  [[image:image-20220523181246-5.png]]
441 441  
442 442  (((
454 +
455 +
443 443  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
444 444  )))
445 445  
... ... @@ -450,9 +450,10 @@
450 450  * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
451 451  
452 452  (((
453 -(% style="color:red" %)Note: DO3 is not valid for LT-22222-L.
466 +(% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.**
454 454  )))
455 455  
469 +
456 456  (((
457 457  **To use counting mode, please run:**
458 458  )))
... ... @@ -461,12 +461,7 @@
461 461  (((
462 462  (((
463 463  **AT+MOD=3**
464 -)))
465 -)))
466 466  
467 -(% class="box infomessage" %)
468 -(((
469 -(((
470 470  **ATZ**
471 471  )))
472 472  )))
... ... @@ -498,7 +498,7 @@
498 498  * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
499 499  
500 500  (((
501 -(% style="color:red" %)Note: DO3 is not valid for LT-22222-L.
510 +(% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.**
502 502  )))
503 503  
504 504  (((
... ... @@ -511,20 +511,13 @@
511 511  (((
512 512  (((
513 513  **AT+MOD=4**
514 -)))
515 -)))
516 516  
517 -(% class="box infomessage" %)
518 -(((
519 -(((
520 520  **ATZ**
521 521  )))
522 522  )))
523 523  
524 -(((
525 -
526 -)))
527 527  
529 +
528 528  (((
529 529  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
530 530  )))
... ... @@ -533,35 +533,16 @@
533 533  
534 534  
535 535  **Plus below command for AVI1 Counting:**
536 -)))
537 537  
538 -(% class="box infomessage" %)
539 -(((
540 -(((
541 -**AT+SETCNT=3,60   (set AVI Count to 60)**
542 -)))
543 -)))
544 544  
545 -(% class="box infomessage" %)
546 -(((
547 -(((
548 -**AT+VOLMAX=20000   (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)**
549 -)))
550 -)))
540 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)**  (set AVI Count to 60)**
551 551  
552 -(% class="box infomessage" %)
553 -(((
554 -(((
555 -**AT+VOLMAX=20000,0   (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)**
556 -)))
557 -)))
542 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)**  (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)**
558 558  
559 -(% class="box infomessage" %)
560 -(((
561 -(((
562 -**AT+VOLMAX=20000,1   (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)**
544 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)**  (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)**
545 +
546 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)**  (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)**
563 563  )))
564 -)))
565 565  
566 566  
567 567  
... ... @@ -585,7 +585,7 @@
585 585  )))
586 586  
587 587  (((
588 -(% style="color:red" %)Note: DO3 is not valid for LT-22222-L.
571 +(% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.**
589 589  )))
590 590  
591 591  (((
... ... @@ -598,12 +598,7 @@
598 598  (((
599 599  (((
600 600  **AT+MOD=5**
601 -)))
602 -)))
603 603  
604 -(% class="box infomessage" %)
605 -(((
606 -(((
607 607  **ATZ**
608 608  )))
609 609  )))
... ... @@ -621,20 +621,27 @@
621 621  
622 622  For example, if user has configured below commands:
623 623  
624 -* **AT+MOD=1 ** **~-~->** The normal working mode
625 -* **AT+ADDMOD6=1**   **~-~->** Enable trigger
602 +* **AT+MOD=1 ** **~-~->**  The normal working mode
603 +* **AT+ADDMOD6=1**   **~-~->**  Enable trigger
626 626  
605 +
606 +
627 627  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
628 628  
629 629  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
630 630  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
631 631  
632 -**AT Command to set Trigger Condition**:
633 633  
613 +
614 +
615 +(% style="color:#037691" %)**AT Command to set Trigger Condition**:
616 +
617 +
634 634  (% style="color:#4f81bd" %)**Trigger base on voltage**:
635 635  
636 636  Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH>
637 637  
622 +
638 638  **Example:**
639 639  
640 640  AT+AVLIM=3000,6000,0,2000   (If AVI1 voltage lower than 3v or higher than 6v. or AV2 voltage is higher than 2v, LT will trigger Uplink)
... ... @@ -647,6 +647,7 @@
647 647  
648 648  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
649 649  
635 +
650 650  **Example:**
651 651  
652 652  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
... ... @@ -665,8 +665,9 @@
665 665  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
666 666  
667 667  
668 -**Downlink Command to set Trigger Condition:**
669 669  
655 +(% style="color:#037691" %)**Downlink Command to set Trigger Condition:**
656 +
670 670  Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM**
671 671  
672 672  Format: AA xx yy1 yy1 yy2 yy2 yy3 yy3 yy4 yy4
... ... @@ -708,11 +708,14 @@
708 708  
709 709  * Each bits shows if the corresponding trigger has been configured.
710 710  
698 +
699 +
711 711  **Example:**
712 712  
713 713  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
714 714  
715 715  
705 +
716 716  (% style="color:#4f81bd" %)**TRI Status1**(%%) is a combination to show which condition is trigger. Totally 1byte as below
717 717  
718 718  [[image:image-20220524090249-3.png]]
... ... @@ -719,11 +719,14 @@
719 719  
720 720  * Each bits shows which status has been trigger on this uplink.
721 721  
712 +
713 +
722 722  **Example:**
723 723  
724 724  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
725 725  
726 726  
719 +
727 727  (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below
728 728  
729 729  [[image:image-20220524090456-4.png]]
... ... @@ -730,6 +730,8 @@
730 730  
731 731  * Each bits shows which status has been trigger on this uplink.
732 732  
726 +
727 +
733 733  **Example:**
734 734  
735 735  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -737,6 +737,7 @@
737 737  00000101: Means both DI1 and DI2 trigger are enabled.
738 738  
739 739  
735 +
740 740  (% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable. 0x00: MOD6 is disable.
741 741  
742 742  Downlink command to poll MOD6 status:
... ... @@ -747,19 +747,20 @@
747 747  
748 748  
749 749  
746 +
750 750  === 3.3.7 Payload Decoder ===
751 751  
752 752  (((
753 753  
754 754  
755 -**Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]]
756 -
757 -
752 +**Decoder for TTN/loraserver/ChirpStack**:  [[https:~~/~~/www.dropbox.com/sh/wtrzu7avdtkmn3z/AACK5NwOMkU9jnvf1uCMuqrVa?dl=0>>https://www.dropbox.com/sh/wtrzu7avdtkmn3z/AACK5NwOMkU9jnvf1uCMuqrVa?dl=0]]
758 758  )))
759 759  
760 760  
756 +
761 761  == 3.4 ​Configure LT via AT or Downlink ==
762 762  
759 +
763 763  User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands
764 764  
765 765  (((
... ... @@ -770,8 +770,12 @@
770 770  
771 771  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
772 772  
770 +
771 +
772 +
773 773  === 3.4.1 Common Commands ===
774 774  
775 +
775 775  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
776 776  
777 777  
... ... @@ -778,80 +778,73 @@
778 778  
779 779  === 3.4.2 Sensor related commands ===
780 780  
782 +
781 781  ==== 3.4.2.1 Set Transmit Interval ====
782 782  
785 +
783 783  Set device uplink interval.
784 784  
785 -* AT Command:
788 +* (% style="color:#037691" %)**AT Command:**
786 786  
787 -(% class="box infomessage" %)
788 -(((
789 789  **AT+TDC=N **
790 -)))
791 791  
792 +
792 792  **Example: **AT+TDC=30000. Means set interval to 30 seconds
793 793  
794 794  
795 -* Downlink Payload (prefix 0x01):
796 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x01):**
796 796  
797 -(% class="box infomessage" %)
798 -(((
799 799  **0x01 aa bb cc     ~/~/ Same as AT+TDC=0x(aa bb cc)**
800 -)))
801 801  
802 802  
803 803  
802 +
804 804  ==== 3.4.2.2 Set Work Mode (AT+MOD) ====
805 805  
805 +
806 806  Set work mode.
807 807  
808 -* AT Command:
808 +* (% style="color:#037691" %)**AT Command:**
809 809  
810 -(% class="box infomessage" %)
811 -(((
812 812  **AT+MOD=N  **
813 -)))
814 814  
812 +
815 815  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
816 816  
817 817  
818 -* Downlink Payload (prefix 0x0A):
816 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):**
819 819  
820 -(% class="box infomessage" %)
821 -(((
822 -**0x0A aa     ~/~/ Same as AT+MOD=aa**
823 -)))
818 +**0x0A aa    ** ~/~/ Same as AT+MOD=aa
824 824  
825 825  
826 826  
822 +
827 827  ==== 3.4.2.3 Poll an uplink ====
828 828  
829 -* AT Command:
830 830  
826 +* (% style="color:#037691" %)**AT Command:**
827 +
831 831  There is no AT Command to poll uplink
832 832  
833 833  
834 -* Downlink Payload (prefix 0x08):
831 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x08):**
835 835  
836 -(% class="box infomessage" %)
837 -(((
838 -**0x08 FF     ~/~/ Poll an uplink,**
839 -)))
833 +**0x08 FF     **~/~/ Poll an uplink
840 840  
835 +
841 841  **Example**: 0x08FF, ask device to send an Uplink
842 842  
843 843  
844 844  
840 +
845 845  ==== 3.4.2.4 Enable Trigger Mode ====
846 846  
843 +
847 847  Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
848 848  
849 -* AT Command:
846 +* (% style="color:#037691" %)**AT Command:**
850 850  
851 -(% class="box infomessage" %)
852 -(((
853 853  **AT+ADDMOD6=1 or 0**
854 -)))
855 855  
856 856  1: Enable Trigger Mode
857 857  
... ... @@ -858,43 +858,38 @@
858 858  0: Disable Trigger Mode
859 859  
860 860  
861 -* Downlink Payload (prefix 0x0A 06):
855 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):**
862 862  
863 -(% class="box infomessage" %)
864 -(((
865 -**0x0A 06 aa     ~/~/ Same as AT+ADDMOD6=aa,**
866 -)))
857 +**0x0A 06 aa    ** ~/~/ Same as AT+ADDMOD6=aa
867 867  
868 868  
869 869  
861 +
870 870  ==== 3.4.2.5 Poll trigger settings ====
871 871  
864 +
872 872  Poll trigger settings,
873 873  
874 -* AT Command:
867 +* (% style="color:#037691" %)**AT Command:**
875 875  
876 876  There is no AT Command for this feature.
877 877  
878 878  
879 -* Downlink Payload (prefix 0x AB 06):
872 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):**
880 880  
881 -(% class="box infomessage" %)
882 -(((
883 -**0xAB 06  ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command**
884 -)))
874 +**0xAB 06         **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command
885 885  
886 886  
887 887  
878 +
888 888  ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ====
889 889  
881 +
890 890  Enable Disable DI1/DI2/DI2 as trigger,
891 891  
892 -* AT Command:
884 +* (% style="color:#037691" %)**AT Command:**
893 893  
894 -(% class="box infomessage" %)
895 -(((
896 896  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
897 -)))
898 898  
899 899  
900 900  **Example:**
... ... @@ -901,25 +901,21 @@
901 901  
902 902  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
903 903  
904 -* Downlink Payload (prefix 0xAA 02):
893 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):**
905 905  
906 -(% class="box infomessage" %)
907 -(((
908 -**0xAA 02 aa bb  ~/~/ Same as AT+DTRI=aa,bb**
909 -)))
895 +**0xAA 02 aa bb        **~/~/ Same as AT+DTRI=aa,bb
910 910  
911 911  
912 912  
899 +
913 913  ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ====
914 914  
902 +
915 915  Set DI1 or DI3(for LT-33222-L) trigger.
916 916  
917 -* AT Command:
905 +* (% style="color:#037691" %)**AT Command:**
918 918  
919 -(% class="box infomessage" %)
920 -(((
921 921  **AT+TRIG1=a,b**
922 -)))
923 923  
924 924  a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1).
925 925  
... ... @@ -931,26 +931,22 @@
931 931  AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms )
932 932  
933 933  
934 -* Downlink Payload (prefix 0x09 01 ):
919 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):**
920 +* **0x09 01 aa bb cc    ** ~/~/ same as AT+TRIG1=aa,0x(bb cc)
935 935  
936 -(% class="box infomessage" %)
937 -(((
938 -**0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)**
939 -)))
940 940  
941 941  
942 942  
943 943  ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
944 944  
927 +
945 945  Set DI2 trigger.
946 946  
947 -* AT Command:
930 +* (% style="color:#037691" %)**AT Command:**
948 948  
949 -(% class="box infomessage" %)
950 -(((
951 951  **AT+TRIG2=a,b**
952 -)))
953 953  
934 +
954 954  a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1).
955 955  
956 956  b : delay timing.
... ... @@ -961,93 +961,82 @@
961 961  AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms )
962 962  
963 963  
964 -* Downlink Payload (prefix 0x09 02 ):
945 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):**
965 965  
966 -(% class="box infomessage" %)
967 -(((
968 -**0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)**
969 -)))
947 +**0x09 02 aa bb cc           **~/~/ same as AT+TRIG1=aa,0x(bb cc)
970 970  
971 971  
972 972  
951 +
973 973  ==== 3.4.2.9 Trigger – Set AC (current) as trigger ====
974 974  
954 +
975 975  Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
976 976  
977 -* AT Command:
957 +* (% style="color:#037691" %)**AT Command**
978 978  
979 -(% class="box infomessage" %)
980 -(((
981 -**AT+ACLIM. **
982 -)))
959 +**AT+ACLIM**
983 983  
984 984  
985 -* Downlink Payload (prefix 0xAA 01 ):
962 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )**
986 986  
987 -(% class="box infomessage" %)
988 -(((
989 -**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
990 -)))
964 +**0x AA 01 aa bb cc dd ee ff gg hh        ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
991 991  
992 992  
993 993  
968 +
994 994  ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ====
995 995  
971 +
996 996  Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
997 997  
998 -* AT Command:
974 +* (% style="color:#037691" %)**AT Command**
999 999  
1000 -(% class="box infomessage" %)
1001 -(((
1002 -**AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
1003 -)))
976 +**AT+AVLIM  See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
1004 1004  
1005 1005  
1006 -* Downlink Payload (prefix 0xAA 00 ):
979 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )**
1007 1007  
1008 -(% class="box infomessage" %)
1009 -(((
1010 -**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] **
1011 -)))
981 +**0x AA 00 aa bb cc dd ee ff gg hh    ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
1012 1012  
1013 1013  
1014 1014  
985 +
1015 1015  ==== 3.4.2.11 Trigger – Set minimum interval ====
1016 1016  
1017 -Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger.
1018 1018  
1019 -* AT Command:
989 +Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger.
1020 1020  
1021 -(% class="box infomessage" %)
1022 -(((
1023 -**AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.**
1024 -)))
991 +* (% style="color:#037691" %)**AT Command**
1025 1025  
993 +**AT+ATDC=5        ** Device won't response the second trigger within 5 minute after the first trigger.
1026 1026  
1027 -* Downlink Payload (prefix 0xAC ):
1028 1028  
1029 -(% class="box infomessage" %)
996 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )**
997 +
998 +**0x AC aa bb   ** ~/~/ same as AT+ATDC=0x(aa bb)   . Unit (min)
999 +
1030 1030  (((
1031 -**0x AC aa bb ~/~/ same as AT+ATDC=0x(aa bb)   . Unit (min)**
1001 +
1002 +
1003 +(% style="color:red" %)**Note: ATDC setting must be more than 5min**
1032 1032  )))
1033 1033  
1034 1034  
1035 1035  
1008 +
1036 1036  ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ====
1037 1037  
1038 -* AT Command:
1039 1039  
1012 +* (% style="color:#037691" %)**AT Command**
1013 +
1040 1040  There is no AT Command to control Digital Output
1041 1041  
1042 1042  
1043 -* Downlink Payload (prefix 0x02):
1017 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x02)**
1018 +* **0x02 aa bb cc     **~/~/ Set DO1/DO2/DO3 output
1044 1044  
1045 -(% class="box infomessage" %)
1046 1046  (((
1047 -**0x02 aa bb cc     ~/~/ Set DO1/DO2/DO3 output**
1048 -)))
1049 -
1050 -(((
1051 1051  If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low.
1052 1052  )))
1053 1053  
... ... @@ -1058,31 +1058,29 @@
1058 1058  [[image:image-20220524092754-5.png]]
1059 1059  
1060 1060  (((
1061 -(% style="color:red" %)Note: For LT-22222-L, there is no DO3, the last byte can use any value.
1031 +(% style="color:red" %)**Note: For LT-22222-L, there is no DO3, the last byte can use any value.**
1062 1062  )))
1063 1063  
1064 1064  (((
1065 -(% style="color:red" %)Device will upload a packet if downlink code executes successfully.
1035 +(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.**
1066 1066  )))
1067 1067  
1068 1068  
1069 1069  
1040 +
1070 1070  ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ====
1071 1071  
1072 -* AT Command:
1073 1073  
1044 +* (% style="color:#037691" %)**AT Command**
1045 +
1074 1074  There is no AT Command to control Digital Output
1075 1075  
1076 1076  
1077 -* Downlink Payload (prefix 0xA9):
1049 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA9)**
1078 1078  
1079 -(% class="box infomessage" %)
1080 -(((
1081 -(((
1082 -**0xA9 aa bb cc     ~/~/ Set DO1/DO2/DO3 output with time control**
1083 -)))
1084 -)))
1051 +**0xA9 aa bb cc     **~/~/ Set DO1/DO2/DO3 output with time control
1085 1085  
1053 +
1086 1086  This is to control the digital output time of DO pin. Include four bytes:
1087 1087  
1088 1088  (% style="color:#4f81bd" %)**First Byte**(%%)**:** Type code (0xA9)
... ... @@ -1109,11 +1109,11 @@
1109 1109  [[image:image-20220524093351-8.png]]
1110 1110  
1111 1111  
1112 -(% style="color:#4f81bd" %)**Sixth and Seventh Byte**:
1080 +(% style="color:#4f81bd" %)**Sixth and Seventh and Eighth and Ninth Byte**:
1113 1113  
1114 1114   Latching time. Unit: ms
1115 1115  
1116 -Device will upload a packet if downlink code executes successfully.
1084 +(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.**
1117 1117  
1118 1118  
1119 1119  **Example payload:**
... ... @@ -1136,20 +1136,20 @@
1136 1136  
1137 1137  
1138 1138  
1107 +
1139 1139  ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1140 1140  
1141 -* AT Command:
1142 1142  
1111 +* (% style="color:#037691" %)**AT Command:**
1112 +
1143 1143  There is no AT Command to control Relay Output
1144 1144  
1145 1145  
1146 -* Downlink Payload (prefix 0x03):
1116 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x03):**
1147 1147  
1148 -(% class="box infomessage" %)
1149 -(((
1150 -**0x03 aa bb     ~/~/ Set RO1/RO2 output**
1151 -)))
1118 +**0x03 aa bb     **~/~/ Set RO1/RO2 output
1152 1152  
1120 +
1153 1153  (((
1154 1154  If payload = 0x030100, it means set RO1 to close and RO2 to open.
1155 1155  )))
... ... @@ -1162,24 +1162,24 @@
1162 1162  [[image:image-20220524093724-9.png]]
1163 1163  )))
1164 1164  
1165 -Device will upload a packet if downlink code executes successfully.
1133 +(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.**
1166 1166  
1167 1167  
1168 1168  
1137 +
1169 1169  ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ====
1170 1170  
1171 -* AT Command:
1172 1172  
1141 +* (% style="color:#037691" %)**AT Command:**
1142 +
1173 1173  There is no AT Command to control Relay Output
1174 1174  
1175 1175  
1176 -* Downlink Payload (prefix 0x05):
1146 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x05):**
1177 1177  
1178 -(% class="box infomessage" %)
1179 -(((
1180 -**0x05 aa bb cc dd     ~/~/ Set RO1/RO2 relay with time control:**
1181 -)))
1148 +**0x05 aa bb cc dd     **~/~/ Set RO1/RO2 relay with time control
1182 1182  
1150 +
1183 1183  This is to control the relay output time of relay. Include four bytes:
1184 1184  
1185 1185  (% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05)
... ... @@ -1193,63 +1193,57 @@
1193 1193  
1194 1194  (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status:
1195 1195  
1196 -[[image:image-20220524093831-10.png]]
1164 +[[image:image-20220714135731-1.png||height="406" width="627"]]
1197 1197  
1198 1198  
1199 -(% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms
1167 +(% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh Bytes(cc)**(%%): Latching time. Unit: ms
1200 1200  
1201 -Device will upload a packet if downlink code executes successfully.
1169 +(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.**
1202 1202  
1203 1203  
1204 1204  **Example payload:**
1205 1205  
1206 -**~1. 05 01 11 07 D0**
1174 +**~1. 05 01 11 07 D**
1207 1207  
1208 -Relay1 and Relay 2 will be set to NO , last 2 seconds, then change back to original state.
1176 +Relay1 and Relay 2 will be set to NC , last 2 seconds, then change back to original state.
1209 1209  
1210 1210  **2. 05 01 10 07 D0**
1211 1211  
1212 -Relay1 will change to NO, Relay2 will change to NC, last 2 seconds, then both change back to original state.
1180 +Relay1 will change to NC, Relay2 will change to NO, last 2 seconds, then both change back to original state.
1213 1213  
1214 1214  **3. 05 00 01 07 D0**
1215 1215  
1216 -Relay1 will change to NC, Relay2 will change to NO, last 2 seconds, then relay change to NO, Relay2 change to NC.
1184 +Relay1 will change to NO, Relay2 will change to NC, last 2 seconds, then relay change to NC,Relay2 change to NO.
1217 1217  
1218 1218  **4. 05 00 00 07 D0**
1219 1219  
1220 -Relay 1 & relay2 will change to NC, last 2 seconds, then both change to NO.
1188 +Relay 1 & relay2 will change to NO, last 2 seconds, then both change to NC.
1221 1221  
1222 1222  
1223 1223  
1224 1224  ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ====
1225 1225  
1194 +
1226 1226  When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1227 1227  
1228 -* AT Command:
1197 +* (% style="color:#037691" %)**AT Command:**
1229 1229  
1230 -(% class="box infomessage" %)
1231 -(((
1232 -**AT+VOLMAX    ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]**
1233 -)))
1199 +**AT+VOLMAX   ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1234 1234  
1235 1235  
1236 -* Downlink Payload (prefix 0xA5):
1202 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):**
1237 1237  
1238 -(% class="box infomessage" %)
1239 -(((
1240 -**0xA5 aa bb cc   ~/~/ Same as AT+VOLMAX=(aa bb),cc**
1241 -)))
1204 +**0xA5 aa bb cc   **~/~/ Same as AT+VOLMAX=(aa bb),cc
1242 1242  
1243 1243  
1244 1244  
1208 +
1245 1245  ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ====
1246 1246  
1247 -* AT Command:
1248 1248  
1249 -(% class="box infomessage" %)
1250 -(((
1212 +* (% style="color:#037691" %)**AT Command:**
1213 +
1251 1251  **AT+SETCNT=aa,(bb cc dd ee) **
1252 -)))
1253 1253  
1254 1254  aa: 1: Set count1,
1255 1255  
... ... @@ -1260,60 +1260,163 @@
1260 1260  Bb cc dd ee: number to be set
1261 1261  
1262 1262  
1263 -* Downlink Payload (prefix 0xA8):
1225 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA8):**
1264 1264  
1265 -(% class="box infomessage" %)
1266 -(((
1267 -**0x A8 aa bb cc dd ee     ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)**
1268 -)))
1227 +**0x A8 aa bb cc dd ee     **~/~/ same as AT+SETCNT=aa,(bb cc dd ee)
1269 1269  
1270 1270  
1271 1271  
1231 +
1272 1272  ==== 3.4.2.18 Counting ~-~- Clear Counting ====
1273 1273  
1234 +
1274 1274  Clear counting for counting mode
1275 1275  
1276 -* AT Command:
1237 +* (% style="color:#037691" %)**AT Command:**
1277 1277  
1278 -(% class="box infomessage" %)
1279 -(((
1280 -**AT+CLRCOUNT ~/~/ clear all counting**
1281 -)))
1239 +**AT+CLRCOUNT ** ~/~/ clear all counting
1282 1282  
1283 -* Downlink Payload (prefix 0xA6):
1284 1284  
1285 -(% class="box infomessage" %)
1286 -(((
1287 -**0x A6 01     ~/~/ clear all counting,**
1288 -)))
1242 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):**
1289 1289  
1244 +**0x A6 01    ** ~/~/ clear all counting
1290 1290  
1291 1291  
1247 +
1248 +
1292 1292  ==== 3.4.2.19 Counting ~-~- Change counting mode save time ====
1293 1293  
1294 -* AT Command:
1295 1295  
1296 -(% class="box infomessage" %)
1297 -(((
1298 -**AT+COUTIME=60  ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)**
1299 -)))
1252 +* (% style="color:#037691" %)**AT Command:**
1300 1300  
1301 -* Downlink Payload (prefix 0xA7):
1254 +**AT+COUTIME=60  **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)
1302 1302  
1303 -(% class="box infomessage" %)
1256 +
1257 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA7):**
1258 +
1259 +**0x A7 aa bb cc     **~/~/ same as AT+COUTIME =aa bb cc,
1260 +
1304 1304  (((
1305 -**0x A7 aa bb cc     ~/~/ same as AT+COUTIME =aa bb cc,**
1262 +range: aa bb cc:0 to 16777215,  (unit:second)
1263 +
1264 +
1265 +
1266 +
1306 1306  )))
1307 1307  
1269 +==== 3.4.2.20 Reset save DR DO state ====
1270 +
1271 +
1272 +* (% style="color:#037691" %)**AT Command:**
1273 +
1274 +**AT+RODORET=1  **~/~/ RODO will close when the device joining the network. (default)
1275 +
1276 +**AT+RODORET=0  **~/~/After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state is not changed when it is reconnected to the network.
1277 +
1278 +
1279 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAD):**
1280 +
1281 +**0x AD aa      **~/~/ same as AT+RODORET =aa
1282 +
1308 1308  (((
1309 -range: aa bb cc:0 to 16777215,  (unit:second)
1284 +
1310 1310  
1286 +
1287 +
1288 +==== 3.4.2.21 Encrypted payload ====
1289 +
1290 +
1291 +* (% style="color:#037691" %)**AT Command:**
1292 +
1293 +**AT+DECRYPT=1  **~/~/ The payload is uploaded without encryption
1294 +
1295 +**AT+DECRYPT=0  **~/~/Encrypt when uploading payload (default)
1296 +
1297 +
1298 +
1299 +
1300 +==== 3.4.2.22 Get sensor value ====
1301 +
1302 +
1303 +* (% style="color:#037691" %)**AT Command:**
1304 +
1305 +**AT+GETSENSORVALUE=0  **~/~/ The serial port gets the reading of the current sensor
1306 +
1307 +**AT+GETSENSORVALUE=1  **~/~/The serial port gets the current sensor reading and uploads it.
1308 +
1309 +
1310 +
1311 +
1312 +==== 3.4.2.23 Resets the downlink packet count ====
1313 +
1314 +
1315 +* (% style="color:#037691" %)**AT Command:**
1316 +
1317 +**AT+DISFCNTCHECK=0  **~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node will no longer receive downlink packets (default)
1318 +
1319 +**AT+DISFCNTCHECK=1  **~/~/When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node resets the downlink packet count and keeps it consistent with the server downlink packet count.
1320 +
1321 +
1322 +
1323 +
1324 +==== 3.4.2.24 When the limit bytes are exceeded, upload in batches ====
1325 +
1326 +
1327 +* (% style="color:#037691" %)**AT Command:**
1328 +
1329 + **AT+DISMACANS=0**  ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of 11 bytes (DR0 of US915, DR2 of AS923, DR2 of AU195), the node will send a packet with a payload of 00 and a port of 4. (default)
1330 +
1331 + **AT+DISMACANS=1**      ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of the DR, the node will ignore the MACANS and not reply, and only upload the payload part.
1332 +
1333 +
1334 +* (% style="color:#037691" %)**Downlink Payload **(%%)**:**
1335 +
1336 +**0x21 00 01 ** ~/~/ Set  the DISMACANS=1
1337 +
1338 +
1339 +
1340 +
1341 +==== 3.4.2.25 Copy downlink to uplink ====
1342 +
1343 +
1344 +* (% style="color:#037691" %)**AT Command**(%%)**:**
1345 +
1346 + **AT+RPL=5**  ~/~/ After receiving the package from the server, it will immediately upload the content of the package to the server, the port number is 100.
1347 +
1348 +Example:**aa xx xx xx xx**         ~/~/ aa indicates whether the configuration has changed, 00 is yes, 01 is no; xx xx xx xx are the bytes sent.
1349 +
1350 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173747-6.png?width=1124&height=165&rev=1.1||alt="image-20220823173747-6.png"]]
1351 +
1352 +For example, sending 11 22 33 44 55 66 77 will return invalid configuration 00 11 22 33 44 55 66 77.
1353 +
1354 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173833-7.png?width=1124&height=149&rev=1.1||alt="image-20220823173833-7.png"]]
1355 +
1356 +For example, if 01 00 02 58 is issued, a valid configuration of 01 01 00 02 58 will be returned.
1357 +
1358 +
1359 +
1360 +==== 3.4.2.26 Query version number and frequency band 、TDC ====
1361 +
1362 +
1363 +* (((
1364 +(% style="color:#037691" %)**Downlink Payload**(%%)**:**
1365 +
1366 +**26 01  ** ~/~/ Downlink 26 01 can query device upload frequency, frequency band, software version number, TDC time.
1367 +
1311 1311  
1312 1312  )))
1313 1313  
1371 +**Example:**
1314 1314  
1373 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173929-8.png?width=1205&height=76&rev=1.1||alt="image-20220823173929-8.png"]]
1374 +
1375 +
1376 +
1377 +)))
1378 +
1315 1315  == 3.5 Integrate with Mydevice ==
1316 1316  
1381 +
1317 1317  Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps:
1318 1318  
1319 1319  (((
... ... @@ -1322,14 +1322,15 @@
1322 1322  
1323 1323  (((
1324 1324  (% style="color:blue" %)**Step 2**(%%): To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps:
1390 +
1391 +
1325 1325  )))
1326 1326  
1327 -[[image:1653356737703-362.png||height="232" width="732"]]
1394 +[[image:image-20220719105525-1.png||height="377" width="677"]]
1328 1328  
1329 -[[image:image-20220524094641-11.png||height="390" width="723"]]
1330 1330  
1331 1331  
1332 -[[image:image-20220524094641-12.png||height="402" width="718"]]
1398 +[[image:image-20220719110247-2.png||height="388" width="683"]]
1333 1333  
1334 1334  
1335 1335  (% style="color:blue" %)**Step 3**(%%): Create an account or log in Mydevices.
... ... @@ -1362,8 +1362,10 @@
1362 1362  
1363 1363  == 3.6 Interface Detail ==
1364 1364  
1431 +
1365 1365  === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) ===
1366 1366  
1434 +
1367 1367  Support NPN Type sensor
1368 1368  
1369 1369  [[image:1653356991268-289.png]]
... ... @@ -1372,6 +1372,7 @@
1372 1372  
1373 1373  === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) ===
1374 1374  
1443 +
1375 1375  (((
1376 1376  The DI port of LT-22222-L can support NPN or PNP output sensor.
1377 1377  )))
... ... @@ -1378,7 +1378,9 @@
1378 1378  
1379 1379  (((
1380 1380  (((
1381 -Internal circuit as below, the NEC2501 is a photocoupler, the Active current (from NEC2501 pin 1 to pin 2 is 1ma and the max current is 50mA. When there is active current pass NEC2501 pin1 to pin2. The DI will be active high
1450 +Internal circuit as below, the NEC2501 is a photocoupler, the Active current (from NEC2501 pin 1 to pin 2 is 1ma and the max current is 50mA. When there is active current pass NEC2501 pin1 to pin2. The DI will be active high.
1451 +
1452 +
1382 1382  )))
1383 1383  )))
1384 1384  
... ... @@ -1403,10 +1403,10 @@
1403 1403  )))
1404 1404  
1405 1405  * (((
1406 -Connect sensors output to DI1-
1477 +Connect sensor's output to DI1-
1407 1407  )))
1408 1408  * (((
1409 -Connect sensors VCC to DI1+.
1480 +Connect sensor's VCC to DI1+.
1410 1410  )))
1411 1411  
1412 1412  (((
... ... @@ -1414,15 +1414,17 @@
1414 1414  )))
1415 1415  
1416 1416  (((
1417 -[[image:1653968155772-850.png||height="23" width="19"]]**= DI1+ / 1K.**
1488 +[[image:1653968155772-850.png||height="23" width="19"]]**= DI1**+** / 1K.**
1418 1418  )))
1419 1419  
1420 1420  (((
1421 -If DI1+ = 12v, the [[image:1653968155772-850.png||height="23" width="19"]]= 12mA , So the LT-22222-L will be able to detect this active signal.
1492 +If** DI1+ **= **12v**, the [[image:1653968155772-850.png||height="23" width="19"]]= 12mA , So the LT-22222-L will be able to detect this active signal.
1422 1422  )))
1423 1423  
1424 1424  (((
1425 1425  
1497 +
1498 +
1426 1426  )))
1427 1427  
1428 1428  (((
... ... @@ -1434,10 +1434,10 @@
1434 1434  )))
1435 1435  
1436 1436  * (((
1437 -Connect sensors output to DI1+
1510 +Connect sensor's output to DI1+
1438 1438  )))
1439 1439  * (((
1440 -Connect sensors GND DI1-.
1513 +Connect sensor's GND DI1-.
1441 1441  )))
1442 1442  
1443 1443  (((
... ... @@ -1454,6 +1454,8 @@
1454 1454  
1455 1455  (((
1456 1456  
1530 +
1531 +
1457 1457  )))
1458 1458  
1459 1459  (((
... ... @@ -1465,10 +1465,10 @@
1465 1465  )))
1466 1466  
1467 1467  * (((
1468 -Connect sensors output to DI1+ with a serial 50K resistor
1543 +Connect sensor's output to DI1+ with a serial 50K resistor
1469 1469  )))
1470 1470  * (((
1471 -Connect sensors GND DI1-.
1546 +Connect sensor's GND DI1-.
1472 1472  )))
1473 1473  
1474 1474  (((
... ... @@ -1487,6 +1487,7 @@
1487 1487  
1488 1488  === 3.6.3 Digital Output Port: DO1/DO2 /DO3 ===
1489 1489  
1565 +
1490 1490  NPN output: GND or Float. Max voltage can apply to output pin is 36v.
1491 1491  
1492 1492  [[image:1653357531600-905.png]]
... ... @@ -1495,6 +1495,7 @@
1495 1495  
1496 1496  === 3.6.4 Analog Input Interface ===
1497 1497  
1574 +
1498 1498  The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is:
1499 1499  
1500 1500  
... ... @@ -1526,6 +1526,7 @@
1526 1526  
1527 1527  === 3.6.5 Relay Output ===
1528 1528  
1606 +
1529 1529  (((
1530 1530  The LT serial controller has two relay interfaces; each interface uses two pins of the screw terminal. User can connect other device’s Power Line to in serial of RO1_1 and RO_2. Such as below:
1531 1531  )))
... ... @@ -1532,6 +1532,7 @@
1532 1532  
1533 1533  [[image:image-20220524100215-9.png]]
1534 1534  
1613 +
1535 1535  [[image:image-20220524100215-10.png||height="382" width="723"]]
1536 1536  
1537 1537  
... ... @@ -1538,13 +1538,17 @@
1538 1538  
1539 1539  == 3.7 LEDs Indicators ==
1540 1540  
1620 +
1541 1541  [[image:image-20220524100748-11.png]]
1542 1542  
1543 1543  
1624 +
1544 1544  = 4. Use AT Command =
1545 1545  
1627 +
1546 1546  == 4.1 Access AT Command ==
1547 1547  
1630 +
1548 1548  LT supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to LT for using AT command, as below.
1549 1549  
1550 1550  [[image:1653358238933-385.png]]
... ... @@ -1743,8 +1743,6 @@
1743 1743  
1744 1744  (((
1745 1745  AT+CFG: Print all settings
1746 -
1747 -
1748 1748  )))
1749 1749  
1750 1750  
... ... @@ -1751,6 +1751,7 @@
1751 1751  
1752 1752  == 4.2 Common AT Command Sequence ==
1753 1753  
1835 +
1754 1754  === 4.2.1 Multi-channel ABP mode (Use with SX1301/LG308) ===
1755 1755  
1756 1756  (((
... ... @@ -1790,8 +1790,6 @@
1790 1790  
1791 1791  (((
1792 1792  (% style="background-color:#dcdcdc" %)ATZ
1793 -
1794 -
1795 1795  )))
1796 1796  
1797 1797  
... ... @@ -1863,6 +1863,8 @@
1863 1863  2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1864 1864  3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1865 1865  4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1946 +
1947 +
1866 1866  )))
1867 1867  
1868 1868  (((
... ... @@ -1876,13 +1876,16 @@
1876 1876  
1877 1877  === 4.2.3 Change to Class A ===
1878 1878  
1961 +
1879 1879  If sensor JOINED
1880 1880  (% style="background-color:#dcdcdc" %)AT+CLASS=A
1881 1881  ATZ
1882 1882  
1883 1883  
1967 +
1884 1884  = 5. FAQ =
1885 1885  
1970 +
1886 1886  == 5.1 How to upgrade the image? ==
1887 1887  
1888 1888  
... ... @@ -1899,12 +1899,14 @@
1899 1899  
1900 1900  (((
1901 1901  (% style="color:blue" %)**Step1**(%%)**:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
1902 -(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].
1987 +(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:https://www.dropbox.com/sh/g99v0fxcltn9r1y/AADKXQ2v5ZT-S3sxdmbvE7UAa/LT-22222-L/image?dl=0&subfolder_nav_tracking=1]].
1903 1903  (% style="color:blue" %)**Step3**(%%)**:** Open flashloader; choose the correct COM port to update.
1904 1904  
1905 1905  
1906 1906  (% style="color:blue" %)**For LT-22222-L**(%%):
1907 -Hold down the PRO button and then momentarily press the RST reset button and the **DO1 led** will change from OFF to ON. When **DO1 LED** is on, it means the device is in download mode.
1992 +Hold down the PRO button and then momentarily press the RST reset button and the (% style="color:red" %)**DO1 led**(%%) will change from OFF to ON. When (% style="color:red" %)**DO1 LED**(%%) is on, it means the device is in download mode.
1993 +
1994 +
1908 1908  )))
1909 1909  
1910 1910   [[image:image-20220524103407-12.png]]
... ... @@ -1916,6 +1916,7 @@
1916 1916  
1917 1917  (% style="color:red" %)**Notice**(%%): In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is:
1918 1918  
2006 +
1919 1919  [[image:1653360054704-518.png||height="186" width="745"]]
1920 1920  
1921 1921  
... ... @@ -1924,6 +1924,8 @@
1924 1924  
1925 1925  
1926 1926  == 5.2 How to change the LoRa Frequency Bands/Region? ==
2015 +
2016 +
1927 1927  )))
1928 1928  )))
1929 1929  
... ... @@ -1934,7 +1934,10 @@
1934 1934  (((
1935 1935  
1936 1936  
2027 +
1937 1937  == 5.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? ==
2029 +
2030 +
1938 1938  )))
1939 1939  
1940 1940  (((
... ... @@ -1947,25 +1947,33 @@
1947 1947  (((
1948 1948  Assume we have a LG02 working in the frequency 868400000 now , below is the step.
1949 1949  
2043 +
1950 1950  
1951 1951  )))
1952 1952  )))
1953 1953  
1954 1954  (((
1955 -(% style="color:#4f81bd" %)**Step1**(%%): Log in TTN, Create an ABP device in the application and input the network session key (NETSKEY), app session key (APPSKEY) from the device.
2049 +(% style="color:blue" %)**Step1**(%%):  Log in TTN, Create an ABP device in the application and input the network session key (NETSKEY), app session key (APPSKEY) from the device.
2050 +
2051 +
1956 1956  )))
1957 1957  
1958 1958  (((
1959 1959  [[image:1653360231087-571.png||height="401" width="727"]]
2056 +
2057 +
1960 1960  )))
1961 1961  
1962 1962  (((
1963 -(% style="color:red" %)Note: user just need to make sure above three keys match, User can change either in TTN or Device to make then match. In TTN, NETSKEY and APPSKEY can be configured by user in setting page, but Device Addr is generated by TTN.
2061 +(% style="color:red" %)**Note: user just need to make sure above three keys match, User can change either in TTN or Device to make then match. In TTN, NETSKEY and APPSKEY can be configured by user in setting page, but Device Addr is generated by TTN.**
1964 1964  )))
1965 1965  
1966 1966  
2065 +
1967 1967  (((
1968 -(% style="color:#4f81bd" %)**Step2**(%%)**: **Run AT Command to make LT work in Single frequency & ABP mode. Below is the AT commands:
2067 +(% style="color:blue" %)**Step2**(%%)**:  **Run AT Command to make LT work in Single frequency & ABP mode. Below is the AT commands:
2068 +
2069 +
1969 1969  )))
1970 1970  
1971 1971  (((
... ... @@ -1989,26 +1989,48 @@
1989 1989  [[image:1653360498588-932.png||height="485" width="726"]]
1990 1990  
1991 1991  
2093 +
1992 1992  == 5.4 Can I see counting event in Serial? ==
1993 1993  
2096 +
1994 1994  (((
1995 -User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesnt support AT+DEBUG. User can update to latest firmware first.
2098 +User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn't support AT+DEBUG. User can update to latest firmware first.
1996 1996  
1997 1997  
2101 +
1998 1998  == 5.5 Can i use point to point communication for LT-22222-L? ==
1999 1999  
2104 +
2000 2000  Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]]
2106 +
2107 +
2108 +
2001 2001  )))
2002 2002  
2003 2003  (((
2004 -
2112 +== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? ==
2005 2005  
2114 +
2115 +If the device is not shut down, but directly powered off.
2116 +
2117 +It will default that this is a power-off state.
2118 +
2119 +In modes 2 to 5, DO RO status and pulse count are saved in flash.
2120 +
2121 +After restart, the status before power failure will be read from flash.
2122 +
2123 +
2124 +
2006 2006  = 6. Trouble Shooting =
2126 +
2127 +
2007 2007  )))
2008 2008  
2009 2009  (((
2010 2010  (((
2011 -== 6.1 Downlink doesn’t work, how to solve it? ==
2132 +== 6.1 Downlink doesn't work, how to solve it? ==
2133 +
2134 +
2012 2012  )))
2013 2013  )))
2014 2014  
... ... @@ -2019,7 +2019,10 @@
2019 2019  (((
2020 2020  
2021 2021  
2145 +
2022 2022  == 6.2 Have trouble to upload image. ==
2147 +
2148 +
2023 2023  )))
2024 2024  
2025 2025  (((
... ... @@ -2029,7 +2029,10 @@
2029 2029  (((
2030 2030  
2031 2031  
2032 -== 6.3 Why I can’t join TTN in US915 /AU915 bands? ==
2158 +
2159 +== 6.3 Why I can't join TTN in US915 /AU915 bands? ==
2160 +
2161 +
2033 2033  )))
2034 2034  
2035 2035  (((
... ... @@ -2043,19 +2043,21 @@
2043 2043  
2044 2044  (% style="color:#4f81bd" %)**LT-22222-L-XXX:**
2045 2045  
2046 -
2047 2047  (% style="color:#4f81bd" %)**XXX:**
2048 2048  
2049 -* (% style="color:#4f81bd" %)**EU433**(%%): LT with frequency bands EU433
2050 -* (% style="color:#4f81bd" %)**EU868**(%%): LT with frequency bands EU868
2051 -* (% style="color:#4f81bd" %)**KR920**(%%): LT with frequency bands KR920
2052 -* (% style="color:#4f81bd" %)**CN470**(%%): LT with frequency bands CN470
2053 -* (% style="color:#4f81bd" %)**AS923**(%%): LT with frequency bands AS923
2054 -* (% style="color:#4f81bd" %)**AU915**(%%): LT with frequency bands AU915
2055 -* (% style="color:#4f81bd" %)**US915**(%%): LT with frequency bands US915
2056 -* (% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865
2057 -* (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779
2177 +* (% style="color:red" %)**EU433**(%%):  LT with frequency bands EU433
2178 +* (% style="color:red" %)**EU868**(%%):  LT with frequency bands EU868
2179 +* (% style="color:red" %)**KR920**(%%):  LT with frequency bands KR920
2180 +* (% style="color:red" %)**CN470**(%%):  LT with frequency bands CN470
2181 +* (% style="color:red" %)**AS923**(%%):  LT with frequency bands AS923
2182 +* (% style="color:red" %)**AU915**(%%):  LT with frequency bands AU915
2183 +* (% style="color:red" %)**US915**(%%):  LT with frequency bands US915
2184 +* (% style="color:red" %)**IN865**(%%):  LT with frequency bands IN865
2185 +* (% style="color:red" %)**CN779**(%%):  LT with frequency bands CN779
2058 2058  
2187 +
2188 +
2189 +
2059 2059  = 8. Packing Info =
2060 2060  
2061 2061  
... ... @@ -2073,18 +2073,28 @@
2073 2073  * Package Size / pcs : 14.5 x 8 x 5 cm
2074 2074  * Weight / pcs : 170g
2075 2075  
2207 +
2208 +
2209 +
2076 2076  = 9. Support =
2077 2077  
2212 +
2078 2078  * (((
2079 2079  Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
2080 2080  )))
2081 2081  * (((
2082 2082  Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
2218 +
2219 +
2220 +
2221 +
2083 2083  )))
2084 2084  
2085 2085  = 10. Reference​​​​​ =
2086 2086  
2226 +
2087 2087  * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]]
2088 -* [[Image Download>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]
2089 -* [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]]
2228 +* [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]]
2090 2090  * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]]
2230 +
2231 +
image-20220714135731-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bei
Size
... ... @@ -1,0 +1,1 @@
1 +54.1 KB
Content
image-20220719105525-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bei
Size
... ... @@ -1,0 +1,1 @@
1 +165.5 KB
Content
image-20220719110247-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bei
Size
... ... @@ -1,0 +1,1 @@
1 +52.9 KB
Content