Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -48,6 +48,7 @@ 48 48 49 49 ))) 50 50 51 + 51 51 == 1.2 Specifications == 52 52 53 53 ((( ... ... @@ -164,6 +164,7 @@ 164 164 Packet engine up to 256 bytes with CRC. 165 165 ))) 166 166 168 + 167 167 == 1.3 Features == 168 168 169 169 * LoRaWAN Class A & Class C protocol ... ... @@ -174,6 +174,7 @@ 174 174 * Firmware upgradable via program port 175 175 * Counting 176 176 179 + 177 177 == 1.4 Applications == 178 178 179 179 * Smart Buildings & Home Automation ... ... @@ -183,6 +183,7 @@ 183 183 * Smart Cities 184 184 * Smart Factory 185 185 189 + 186 186 == 1.5 Hardware Variants == 187 187 188 188 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -196,6 +196,7 @@ 196 196 * 1 x Counting Port 197 197 ))) 198 198 203 + 199 199 = 2. Power ON Device = 200 200 201 201 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -276,7 +276,6 @@ 276 276 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 277 277 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 278 278 279 - 280 280 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 281 281 282 282 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -315,8 +315,6 @@ 315 315 * [1] RO1 relay channel is close and the RO1 LED is ON. 316 316 * [0] RO2 relay channel is open and RO2 LED is OFF; 317 317 318 - 319 - 320 320 **LT22222-L:** 321 321 322 322 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -332,7 +332,6 @@ 332 332 ** DO1 is high in case there is load between DO1 and V+. 333 333 ** DO1 LED is off in both case 334 334 335 - 336 336 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 337 337 338 338 ... ... @@ -473,8 +473,6 @@ 473 473 474 474 ((( 475 475 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 476 - 477 - 478 478 ))) 479 479 480 480 ... ... @@ -760,7 +760,6 @@ 760 760 ))) 761 761 762 762 763 - 764 764 == 3.4 Configure LT via AT or Downlink == 765 765 766 766 User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands ... ... @@ -2004,8 +2004,16 @@ 2004 2004 ))) 2005 2005 2006 2006 ((( 2007 - 2005 +== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? == 2008 2008 2007 +If the device is not shut down, but directly powered off. 2008 + 2009 +It will default that this is a power-off state. 2010 + 2011 +In modes 2 to 5, DO RO status and pulse count are saved in flash. 2012 + 2013 +After restart, the status before power failure will be read from flash. 2014 + 2009 2009 = 6. Trouble Shooting = 2010 2010 ))) 2011 2011