<
From version < 79.2 >
edited by Xiaoling
on 2022/06/10 09:40
To version < 81.1 >
edited by Xiaoling
on 2022/06/10 10:20
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -48,6 +48,7 @@
48 48  
49 49  )))
50 50  
51 +
51 51  == 1.2  Specifications ==
52 52  
53 53  (((
... ... @@ -164,6 +164,8 @@
164 164  Packet engine up to 256 bytes with CRC.
165 165  )))
166 166  
168 +
169 +
167 167  == 1.3 Features ==
168 168  
169 169  * LoRaWAN Class A & Class C protocol
... ... @@ -174,6 +174,8 @@
174 174  * Firmware upgradable via program port
175 175  * Counting
176 176  
180 +
181 +
177 177  == 1.4  Applications ==
178 178  
179 179  * Smart Buildings & Home Automation
... ... @@ -183,6 +183,8 @@
183 183  * Smart Cities
184 184  * Smart Factory
185 185  
191 +
192 +
186 186  == 1.5 Hardware Variants ==
187 187  
188 188  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -196,6 +196,8 @@
196 196  * 1 x Counting Port
197 197  )))
198 198  
206 +
207 +
199 199  = 2. Power ON Device =
200 200  
201 201  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -276,7 +276,6 @@
276 276  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
277 277  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
278 278  
279 -
280 280  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
281 281  
282 282  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -315,8 +315,6 @@
315 315  * [1] RO1 relay channel is close and the RO1 LED is ON.
316 316  * [0] RO2 relay channel is open and RO2 LED is OFF;
317 317  
318 -
319 -
320 320  **LT22222-L:**
321 321  
322 322  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -332,7 +332,6 @@
332 332  ** DO1 is high in case there is load between DO1 and V+.
333 333  ** DO1 LED is off in both case
334 334  
335 -
336 336  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
337 337  
338 338  
... ... @@ -473,8 +473,6 @@
473 473  
474 474  (((
475 475  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
476 -
477 -
478 478  )))
479 479  
480 480  
... ... @@ -760,7 +760,6 @@
760 760  )))
761 761  
762 762  
763 -
764 764  == 3.4 ​Configure LT via AT or Downlink ==
765 765  
766 766  User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0