Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -76,8 +76,6 @@ 76 76 ))) 77 77 78 78 ((( 79 - 80 - 81 81 **Interface for Model: LT22222-L:** 82 82 ))) 83 83 ... ... @@ -101,8 +101,6 @@ 101 101 ))) 102 102 103 103 ((( 104 - 105 - 106 106 **LoRa Spec:** 107 107 ))) 108 108 ... ... @@ -162,6 +162,8 @@ 162 162 ))) 163 163 * ((( 164 164 Packet engine up to 256 bytes with CRC. 161 + 162 + 165 165 ))) 166 166 167 167 == 1.3 Features == ... ... @@ -196,6 +196,7 @@ 196 196 * 1 x Counting Port 197 197 ))) 198 198 197 + 199 199 = 2. Power ON Device = 200 200 201 201 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -277,6 +277,7 @@ 277 277 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 278 278 279 279 279 + 280 280 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 281 281 282 282 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -316,7 +316,6 @@ 316 316 * [0] RO2 relay channel is open and RO2 LED is OFF; 317 317 318 318 319 - 320 320 **LT22222-L:** 321 321 322 322 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -333,6 +333,7 @@ 333 333 ** DO1 LED is off in both case 334 334 335 335 335 + 336 336 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 337 337 338 338 ... ... @@ -478,7 +478,6 @@ 478 478 ))) 479 479 480 480 481 - 482 482 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 483 483 484 484 ... ... @@ -631,6 +631,7 @@ 631 631 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 632 632 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 633 633 633 + 634 634 **AT Command to set Trigger Condition**: 635 635 636 636 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -710,6 +710,7 @@ 710 710 711 711 * Each bits shows if the corresponding trigger has been configured. 712 712 713 + 713 713 **Example:** 714 714 715 715 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -721,6 +721,7 @@ 721 721 722 722 * Each bits shows which status has been trigger on this uplink. 723 723 725 + 724 724 **Example:** 725 725 726 726 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. ... ... @@ -732,6 +732,7 @@ 732 732 733 733 * Each bits shows which status has been trigger on this uplink. 734 734 737 + 735 735 **Example:** 736 736 737 737 00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1. ... ... @@ -773,6 +773,7 @@ 773 773 774 774 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 775 775 779 + 776 776 === 3.4.1 Common Commands === 777 777 778 778 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]