From version < 78.3 >
edited by Xiaoling
on 2022/06/10 09:39
To version < 82.3 >
edited by Xiaoling
on 2022/06/20 11:17
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -19,6 +19,8 @@
19 19  == 1.1 What is LT Series I/O Controller ==
20 20  
21 21  (((
22 +
23 +
22 22  The Dragino (% style="color:blue" %)**LT series I/O Modules**(%%) are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (% style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %), **relay output**, **digital input**(%%) and (% style="color:blue" %)**digital output**(%%) etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring.
23 23  )))
24 24  
... ... @@ -48,6 +48,7 @@
48 48  
49 49  )))
50 50  
53 +
51 51  == 1.2  Specifications ==
52 52  
53 53  (((
... ... @@ -162,9 +162,12 @@
162 162  )))
163 163  * (((
164 164  Packet engine up to 256 bytes with CRC.
165 -)))
166 166  
167 167  
170 +
171 +
172 +)))
173 +
168 168  == 1.3 Features ==
169 169  
170 170  * LoRaWAN Class A & Class C protocol
... ... @@ -175,7 +175,6 @@
175 175  * Firmware upgradable via program port
176 176  * Counting
177 177  
178 -
179 179  == 1.4  Applications ==
180 180  
181 181  * Smart Buildings & Home Automation
... ... @@ -185,7 +185,6 @@
185 185  * Smart Cities
186 186  * Smart Factory
187 187  
188 -
189 189  == 1.5 Hardware Variants ==
190 190  
191 191  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -199,7 +199,6 @@
199 199  * 1 x Counting Port
200 200  )))
201 201  
202 -
203 203  = 2. Power ON Device =
204 204  
205 205  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -280,9 +280,6 @@
280 280  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
281 281  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
282 282  
283 -
284 -
285 -
286 286  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
287 287  
288 288  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -336,9 +336,6 @@
336 336  ** DO1 is high in case there is load between DO1 and V+.
337 337  ** DO1 LED is off in both case
338 338  
339 -
340 -
341 -
342 342  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
343 343  
344 344  
... ... @@ -479,8 +479,6 @@
479 479  
480 480  (((
481 481  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
482 -
483 -
484 484  )))
485 485  
486 486  
... ... @@ -766,7 +766,6 @@
766 766  )))
767 767  
768 768  
769 -
770 770  == 3.4 ​Configure LT via AT or Downlink ==
771 771  
772 772  User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands
... ... @@ -2010,8 +2010,16 @@
2010 2010  )))
2011 2011  
2012 2012  (((
2013 -
2007 +== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? ==
2014 2014  
2009 +If the device is not shut down, but directly powered off.
2010 +
2011 +It will default that this is a power-off state.
2012 +
2013 +In modes 2 to 5, DO RO status and pulse count are saved in flash.
2014 +
2015 +After restart, the status before power failure will be read from flash.
2016 +
2015 2015  = 6. Trouble Shooting =
2016 2016  )))
2017 2017  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0