<
From version < 78.2 >
edited by Xiaoling
on 2022/06/10 09:39
To version < 80.2 >
edited by Xiaoling
on 2022/06/10 10:19
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -48,6 +48,7 @@
48 48  
49 49  )))
50 50  
51 +
51 51  == 1.2  Specifications ==
52 52  
53 53  (((
... ... @@ -165,6 +165,8 @@
165 165  )))
166 166  
167 167  
169 +
170 +
168 168  == 1.3 Features ==
169 169  
170 170  * LoRaWAN Class A & Class C protocol
... ... @@ -176,6 +176,8 @@
176 176  * Counting
177 177  
178 178  
182 +
183 +
179 179  == 1.4  Applications ==
180 180  
181 181  * Smart Buildings & Home Automation
... ... @@ -186,6 +186,8 @@
186 186  * Smart Factory
187 187  
188 188  
194 +
195 +
189 189  == 1.5 Hardware Variants ==
190 190  
191 191  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -200,6 +200,8 @@
200 200  )))
201 201  
202 202  
210 +
211 +
203 203  = 2. Power ON Device =
204 204  
205 205  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -280,9 +280,6 @@
280 280  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
281 281  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
282 282  
283 -
284 -
285 -
286 286  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
287 287  
288 288  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -336,9 +336,6 @@
336 336  ** DO1 is high in case there is load between DO1 and V+.
337 337  ** DO1 LED is off in both case
338 338  
339 -
340 -
341 -
342 342  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
343 343  
344 344  
... ... @@ -479,8 +479,6 @@
479 479  
480 480  (((
481 481  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
482 -
483 -
484 484  )))
485 485  
486 486  
... ... @@ -766,7 +766,6 @@
766 766  )))
767 767  
768 768  
769 -
770 770  == 3.4 ​Configure LT via AT or Downlink ==
771 771  
772 772  User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands
... ... @@ -779,6 +779,7 @@
779 779  
780 780  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
781 781  
782 +
782 782  === 3.4.1 Common Commands ===
783 783  
784 784  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0