Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -76,8 +76,6 @@ 76 76 ))) 77 77 78 78 ((( 79 - 80 - 81 81 **Interface for Model: LT22222-L:** 82 82 ))) 83 83 ... ... @@ -101,8 +101,6 @@ 101 101 ))) 102 102 103 103 ((( 104 - 105 - 106 106 **LoRa Spec:** 107 107 ))) 108 108 ... ... @@ -162,9 +162,10 @@ 162 162 ))) 163 163 * ((( 164 164 Packet engine up to 256 bytes with CRC. 161 + 162 + 165 165 ))) 166 166 167 - 168 168 == 1.3 Features == 169 169 170 170 * LoRaWAN Class A & Class C protocol ... ... @@ -175,7 +175,6 @@ 175 175 * Firmware upgradable via program port 176 176 * Counting 177 177 178 - 179 179 == 1.4 Applications == 180 180 181 181 * Smart Buildings & Home Automation ... ... @@ -185,7 +185,6 @@ 185 185 * Smart Cities 186 186 * Smart Factory 187 187 188 - 189 189 == 1.5 Hardware Variants == 190 190 191 191 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -282,7 +282,6 @@ 282 282 283 283 284 284 285 - 286 286 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 287 287 288 288 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -321,6 +321,7 @@ 321 321 * [1] RO1 relay channel is close and the RO1 LED is ON. 322 322 * [0] RO2 relay channel is open and RO2 LED is OFF; 323 323 318 + 324 324 **LT22222-L:** 325 325 326 326 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -338,7 +338,6 @@ 338 338 339 339 340 340 341 - 342 342 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 343 343 344 344 ... ... @@ -484,7 +484,6 @@ 484 484 ))) 485 485 486 486 487 - 488 488 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 489 489 490 490 ... ... @@ -637,6 +637,7 @@ 637 637 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 638 638 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 639 639 633 + 640 640 **AT Command to set Trigger Condition**: 641 641 642 642 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -716,6 +716,7 @@ 716 716 717 717 * Each bits shows if the corresponding trigger has been configured. 718 718 713 + 719 719 **Example:** 720 720 721 721 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -727,6 +727,7 @@ 727 727 728 728 * Each bits shows which status has been trigger on this uplink. 729 729 725 + 730 730 **Example:** 731 731 732 732 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. ... ... @@ -738,6 +738,7 @@ 738 738 739 739 * Each bits shows which status has been trigger on this uplink. 740 740 737 + 741 741 **Example:** 742 742 743 743 00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1. ... ... @@ -779,6 +779,7 @@ 779 779 780 780 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 781 781 779 + 782 782 === 3.4.1 Common Commands === 783 783 784 784 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]