Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -19,6 +19,8 @@ 19 19 == 1.1 What is LT Series I/O Controller == 20 20 21 21 ((( 22 + 23 + 22 22 The Dragino (% style="color:blue" %)**LT series I/O Modules**(%%) are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (% style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %), **relay output**, **digital input**(%%) and (% style="color:blue" %)**digital output**(%%) etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring. 23 23 ))) 24 24 ... ... @@ -48,6 +48,7 @@ 48 48 49 49 ))) 50 50 53 + 51 51 == 1.2 Specifications == 52 52 53 53 ((( ... ... @@ -162,10 +162,12 @@ 162 162 ))) 163 163 * ((( 164 164 Packet engine up to 256 bytes with CRC. 165 -))) 166 166 167 167 168 168 171 + 172 +))) 173 + 169 169 == 1.3 Features == 170 170 171 171 * LoRaWAN Class A & Class C protocol ... ... @@ -203,7 +203,6 @@ 203 203 ))) 204 204 205 205 206 - 207 207 = 2. Power ON Device = 208 208 209 209 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -285,6 +285,7 @@ 285 285 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 286 286 287 287 292 + 288 288 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 289 289 290 290 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -339,6 +339,7 @@ 339 339 ** DO1 LED is off in both case 340 340 341 341 347 + 342 342 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 343 343 344 344 ... ... @@ -375,12 +375,7 @@ 375 375 ((( 376 376 ((( 377 377 **AT+MOD=2** 378 -))) 379 -))) 380 380 381 -(% class="box infomessage" %) 382 -((( 383 -((( 384 384 **ATZ** 385 385 ))) 386 386 ))) ... ... @@ -399,40 +399,15 @@ 399 399 ((( 400 400 ((( 401 401 **AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 402 -))) 403 -))) 404 404 405 -(% class="box infomessage" %) 406 -((( 407 -((( 408 408 **AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 409 -))) 410 -))) 411 411 412 -(% class="box infomessage" %) 413 -((( 414 -((( 415 415 **AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 416 -))) 417 -))) 418 418 419 -(% class="box infomessage" %) 420 -((( 421 -((( 422 422 **AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 423 -))) 424 -))) 425 425 426 -(% class="box infomessage" %) 427 -((( 428 -((( 429 429 **AT+SETCNT=1,60 (Set COUNT1 value to 60)** 430 -))) 431 -))) 432 432 433 -(% class="box infomessage" %) 434 -((( 435 -((( 436 436 **AT+SETCNT=2,60 (Set COUNT2 value to 60)** 437 437 ))) 438 438 ))) ... ... @@ -467,12 +467,7 @@ 467 467 ((( 468 468 ((( 469 469 **AT+MOD=3** 470 -))) 471 -))) 472 472 473 -(% class="box infomessage" %) 474 -((( 475 -((( 476 476 **ATZ** 477 477 ))) 478 478 ))) ... ... @@ -479,11 +479,10 @@ 479 479 480 480 ((( 481 481 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 482 - 483 - 484 484 ))) 485 485 486 486 456 + 487 487 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 488 488 489 489 ... ... @@ -518,20 +518,13 @@ 518 518 ((( 519 519 ((( 520 520 **AT+MOD=4** 521 -))) 522 -))) 523 523 524 -(% class="box infomessage" %) 525 -((( 526 -((( 527 527 **ATZ** 528 528 ))) 529 529 ))) 530 530 531 -((( 532 - 533 -))) 534 534 497 + 535 535 ((( 536 536 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 537 537 ))) ... ... @@ -545,33 +545,17 @@ 545 545 (% class="box infomessage" %) 546 546 ((( 547 547 ((( 548 -**AT+SETCNT=3,60 (set AVI Count to 60)** 549 -))) 550 -))) 511 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 551 551 552 -(% class="box infomessage" %) 553 -((( 554 -((( 555 -**AT+VOLMAX=20000 (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 556 -))) 557 -))) 513 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 558 558 559 -(% class="box infomessage" %) 560 -((( 561 -((( 562 -**AT+VOLMAX=20000,0 (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 563 -))) 564 -))) 515 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 565 565 566 -(% class="box infomessage" %) 567 -((( 568 -((( 569 -**AT+VOLMAX=20000,1 (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 517 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 570 570 ))) 571 571 ))) 572 572 573 573 574 - 575 575 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 576 576 577 577 ... ... @@ -605,12 +605,7 @@ 605 605 ((( 606 606 ((( 607 607 **AT+MOD=5** 608 -))) 609 -))) 610 610 611 -(% class="box infomessage" %) 612 -((( 613 -((( 614 614 **ATZ** 615 615 ))) 616 616 ))) ... ... @@ -636,7 +636,7 @@ 636 636 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 637 637 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 638 638 639 -**AT Command to set Trigger Condition**: 581 +(% style="color:#037691" %)**AT Command to set Trigger Condition**: 640 640 641 641 (% style="color:#4f81bd" %)**Trigger base on voltage**: 642 642 ... ... @@ -672,7 +672,7 @@ 672 672 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 673 673 674 674 675 -**Downlink Command to set Trigger Condition:** 617 +(% style="color:#037691" %)**Downlink Command to set Trigger Condition:** 676 676 677 677 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 678 678 ... ... @@ -765,7 +765,6 @@ 765 765 ))) 766 766 767 767 768 - 769 769 == 3.4 Configure LT via AT or Downlink == 770 770 771 771 User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands ... ... @@ -778,6 +778,8 @@ 778 778 779 779 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 780 780 722 + 723 + 781 781 === 3.4.1 Common Commands === 782 782 783 783 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -790,7 +790,7 @@ 790 790 791 791 Set device uplink interval. 792 792 793 -* AT Command: 736 +* (% style="color:#037691" %)**AT Command:** 794 794 795 795 (% class="box infomessage" %) 796 796 ((( ... ... @@ -800,7 +800,7 @@ 800 800 **Example: **AT+TDC=30000. Means set interval to 30 seconds 801 801 802 802 803 -* Downlink Payload (prefix 0x01): 746 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 804 804 805 805 (% class="box infomessage" %) 806 806 ((( ... ... @@ -813,7 +813,7 @@ 813 813 814 814 Set work mode. 815 815 816 -* AT Command: 759 +* (% style="color:#037691" %)**AT Command:** 817 817 818 818 (% class="box infomessage" %) 819 819 ((( ... ... @@ -823,7 +823,7 @@ 823 823 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 824 824 825 825 826 -* Downlink Payload (prefix 0x0A): 769 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 827 827 828 828 (% class="box infomessage" %) 829 829 ((( ... ... @@ -834,12 +834,12 @@ 834 834 835 835 ==== 3.4.2.3 Poll an uplink ==== 836 836 837 -* AT Command: 780 +* (% style="color:#037691" %)AT Command: 838 838 839 839 There is no AT Command to poll uplink 840 840 841 841 842 -* Downlink Payload (prefix 0x08): 785 +* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 843 843 844 844 (% class="box infomessage" %) 845 845 ((( ... ... @@ -854,7 +854,7 @@ 854 854 855 855 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 856 856 857 -* AT Command: 800 +* (% style="color:#037691" %)AT Command: 858 858 859 859 (% class="box infomessage" %) 860 860 ((( ... ... @@ -866,7 +866,7 @@ 866 866 0: Disable Trigger Mode 867 867 868 868 869 -* Downlink Payload (prefix 0x0A 06): 812 +* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 870 870 871 871 (% class="box infomessage" %) 872 872 ((( ... ... @@ -879,12 +879,12 @@ 879 879 880 880 Poll trigger settings, 881 881 882 -* AT Command: 825 +* (% style="color:#037691" %)AT Command: 883 883 884 884 There is no AT Command for this feature. 885 885 886 886 887 -* Downlink Payload (prefix 0x AB 06): 830 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 888 888 889 889 (% class="box infomessage" %) 890 890 ((( ... ... @@ -897,7 +897,7 @@ 897 897 898 898 Enable Disable DI1/DI2/DI2 as trigger, 899 899 900 -* AT Command: 843 +* (% style="color:#037691" %)AT Command: 901 901 902 902 (% class="box infomessage" %) 903 903 ((( ... ... @@ -909,7 +909,7 @@ 909 909 910 910 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 911 911 912 -* Downlink Payload (prefix 0xAA 02): 855 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 913 913 914 914 (% class="box infomessage" %) 915 915 ((( ... ... @@ -922,7 +922,7 @@ 922 922 923 923 Set DI1 or DI3(for LT-33222-L) trigger. 924 924 925 -* AT Command: 868 +* (% style="color:#037691" %)AT Command: 926 926 927 927 (% class="box infomessage" %) 928 928 ((( ... ... @@ -939,7 +939,7 @@ 939 939 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 940 940 941 941 942 -* Downlink Payload (prefix 0x09 01 ): 885 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 01 ): 943 943 944 944 (% class="box infomessage" %) 945 945 ((( ... ... @@ -952,7 +952,7 @@ 952 952 953 953 Set DI2 trigger. 954 954 955 -* AT Command: 898 +* (% style="color:#037691" %)AT Command: 956 956 957 957 (% class="box infomessage" %) 958 958 ((( ... ... @@ -969,7 +969,7 @@ 969 969 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 970 970 971 971 972 -* Downlink Payload (prefix 0x09 02 ): 915 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 02 ): 973 973 974 974 (% class="box infomessage" %) 975 975 ((( ... ... @@ -982,7 +982,7 @@ 982 982 983 983 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 984 984 985 -* AT Command: 928 +* (% style="color:#037691" %)AT Command: 986 986 987 987 (% class="box infomessage" %) 988 988 ((( ... ... @@ -990,7 +990,7 @@ 990 990 ))) 991 991 992 992 993 -* Downlink Payload (prefix 0xAA 01 ): 936 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 01 ): 994 994 995 995 (% class="box infomessage" %) 996 996 ((( ... ... @@ -1003,7 +1003,7 @@ 1003 1003 1004 1004 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 1005 1005 1006 -* AT Command: 949 +* (% style="color:#037691" %)AT Command: 1007 1007 1008 1008 (% class="box infomessage" %) 1009 1009 ((( ... ... @@ -1011,7 +1011,7 @@ 1011 1011 ))) 1012 1012 1013 1013 1014 -* Downlink Payload (prefix 0xAA 00 ): 957 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 00 ): 1015 1015 1016 1016 (% class="box infomessage" %) 1017 1017 ((( ... ... @@ -1024,7 +1024,7 @@ 1024 1024 1025 1025 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 1026 1026 1027 -* AT Command: 970 +* (% style="color:#037691" %)AT Command: 1028 1028 1029 1029 (% class="box infomessage" %) 1030 1030 ((( ... ... @@ -1032,7 +1032,7 @@ 1032 1032 ))) 1033 1033 1034 1034 1035 -* Downlink Payload (prefix 0xAC ): 978 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAC ): 1036 1036 1037 1037 (% class="box infomessage" %) 1038 1038 ((( ... ... @@ -1043,12 +1043,12 @@ 1043 1043 1044 1044 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 1045 1045 1046 -* AT Command: 989 +* (% style="color:#037691" %)AT Command: 1047 1047 1048 1048 There is no AT Command to control Digital Output 1049 1049 1050 1050 1051 -* Downlink Payload (prefix 0x02): 994 +* (% style="color:#037691" %)Downlink Payload (prefix 0x02): 1052 1052 1053 1053 (% class="box infomessage" %) 1054 1054 ((( ... ... @@ -1077,12 +1077,12 @@ 1077 1077 1078 1078 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1079 1079 1080 -* AT Command: 1023 +* (% style="color:#037691" %)AT Command: 1081 1081 1082 1082 There is no AT Command to control Digital Output 1083 1083 1084 1084 1085 -* Downlink Payload (prefix 0xA9): 1028 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA9): 1086 1086 1087 1087 (% class="box infomessage" %) 1088 1088 ((( ... ... @@ -1146,12 +1146,12 @@ 1146 1146 1147 1147 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1148 1148 1149 -* AT Command: 1092 +* (% style="color:#037691" %)AT Command: 1150 1150 1151 1151 There is no AT Command to control Relay Output 1152 1152 1153 1153 1154 -* Downlink Payload (prefix 0x03): 1097 +* (% style="color:#037691" %)Downlink Payload (prefix 0x03): 1155 1155 1156 1156 (% class="box infomessage" %) 1157 1157 ((( ... ... @@ -1176,18 +1176,16 @@ 1176 1176 1177 1177 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1178 1178 1179 -* AT Command: 1122 +* (% style="color:#037691" %)AT Command: 1180 1180 1181 1181 There is no AT Command to control Relay Output 1182 1182 1183 1183 1184 -* Downlink Payload (prefix 0x05): 1127 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x05):** 1185 1185 1186 -(% class="box infomessage" %) 1187 -((( 1188 -**0x05 aa bb cc dd ~/~/ Set RO1/RO2 relay with time control:** 1189 -))) 1129 +**0x05 aa bb cc dd **~/~/ Set RO1/RO2 relay with time control 1190 1190 1131 + 1191 1191 This is to control the relay output time of relay. Include four bytes: 1192 1192 1193 1193 (% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05) ... ... @@ -1229,35 +1229,28 @@ 1229 1229 1230 1230 1231 1231 1173 + 1232 1232 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1233 1233 1234 1234 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1235 1235 1236 -* AT Command: 1178 +* (% style="color:#037691" %)**AT Command:** 1237 1237 1238 -(% class="box infomessage" %) 1239 -((( 1240 -**AT+VOLMAX ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]** 1241 -))) 1180 +(% style="color:#037691" %)****(%%)**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1242 1242 1243 1243 1244 -* Downlink Payload (prefix 0xA5): 1183 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** 1245 1245 1246 -(% class="box infomessage" %) 1247 -((( 1248 -**0xA5 aa bb cc ~/~/ Same as AT+VOLMAX=(aa bb),cc** 1249 -))) 1185 +**0xA5 aa bb cc **~/~/ Same as AT+VOLMAX=(aa bb),cc 1250 1250 1251 1251 1252 1252 1189 + 1253 1253 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1254 1254 1255 -* AT Command: 1192 +* (% style="color:#037691" %)**AT Command:** 1256 1256 1257 -(% class="box infomessage" %) 1258 -((( 1259 -**AT+SETCNT=aa,(bb cc dd ee) ** 1260 -))) 1194 +(% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) ** 1261 1261 1262 1262 aa: 1: Set count1, 1263 1263 ... ... @@ -1268,51 +1268,40 @@ 1268 1268 Bb cc dd ee: number to be set 1269 1269 1270 1270 1271 -* Downlink Payload (prefix 0xA8): 1205 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA8):** 1272 1272 1273 -(% class="box infomessage" %) 1274 -((( 1275 -**0x A8 aa bb cc dd ee ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)** 1276 -))) 1207 +**0x A8 aa bb cc dd ee **~/~/ same as AT+SETCNT=aa,(bb cc dd ee) 1277 1277 1278 1278 1279 1279 1211 + 1280 1280 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1281 1281 1282 1282 Clear counting for counting mode 1283 1283 1284 -* AT Command: 1216 +* (% style="color:#037691" %)**AT Command:** 1285 1285 1286 -(% class="box infomessage" %) 1287 -((( 1288 -**AT+CLRCOUNT ~/~/ clear all counting** 1289 -))) 1218 +(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1290 1290 1291 -* Downlink Payload (prefix 0xA6): 1292 1292 1293 -(% class="box infomessage" %) 1294 -((( 1295 -**0x A6 01 ~/~/ clear all counting,** 1296 -))) 1221 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** 1297 1297 1223 +**0x A6 01 ** ~/~/ clear all counting 1298 1298 1299 1299 1226 + 1227 + 1300 1300 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1301 1301 1302 -* AT Command: 1230 +* (% style="color:#037691" %)**AT Command:** 1303 1303 1304 -(% class="box infomessage" %) 1305 -((( 1306 -**AT+COUTIME=60 ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)** 1307 -))) 1232 +**AT+COUTIME=60 **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30) 1308 1308 1309 -* Downlink Payload (prefix 0xA7): 1310 1310 1311 -(% class="box infomessage" %) 1312 -((( 1313 -**0x A7 aa bb cc ~/~/ same as AT+COUTIME =aa bb cc,** 1314 -))) 1235 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA7):** 1315 1315 1237 +**0x A7 aa bb cc **~/~/ same as AT+COUTIME =aa bb cc, 1238 + 1316 1316 ((( 1317 1317 range: aa bb cc:0 to 16777215, (unit:second) 1318 1318 ... ... @@ -1320,6 +1320,7 @@ 1320 1320 ))) 1321 1321 1322 1322 1246 + 1323 1323 == 3.5 Integrate with Mydevice == 1324 1324 1325 1325 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: ... ... @@ -2009,8 +2009,16 @@ 2009 2009 ))) 2010 2010 2011 2011 ((( 2012 - 1936 +== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? == 2013 2013 1938 +If the device is not shut down, but directly powered off. 1939 + 1940 +It will default that this is a power-off state. 1941 + 1942 +In modes 2 to 5, DO RO status and pulse count are saved in flash. 1943 + 1944 +After restart, the status before power failure will be read from flash. 1945 + 2014 2014 = 6. Trouble Shooting = 2015 2015 ))) 2016 2016