Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -48,6 +48,7 @@ 48 48 49 49 ))) 50 50 51 + 51 51 == 1.2 Specifications == 52 52 53 53 ((( ... ... @@ -165,7 +165,6 @@ 165 165 ))) 166 166 167 167 168 - 169 169 == 1.3 Features == 170 170 171 171 * LoRaWAN Class A & Class C protocol ... ... @@ -177,7 +177,6 @@ 177 177 * Counting 178 178 179 179 180 - 181 181 == 1.4 Applications == 182 182 183 183 * Smart Buildings & Home Automation ... ... @@ -188,7 +188,6 @@ 188 188 * Smart Factory 189 189 190 190 191 - 192 192 == 1.5 Hardware Variants == 193 193 194 194 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -203,7 +203,6 @@ 203 203 ))) 204 204 205 205 206 - 207 207 = 2. Power ON Device = 208 208 209 209 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -284,7 +284,6 @@ 284 284 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 285 285 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 286 286 287 - 288 288 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 289 289 290 290 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -338,7 +338,6 @@ 338 338 ** DO1 is high in case there is load between DO1 and V+. 339 339 ** DO1 LED is off in both case 340 340 341 - 342 342 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 343 343 344 344 ... ... @@ -479,11 +479,10 @@ 479 479 480 480 ((( 481 481 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 482 - 483 - 484 484 ))) 485 485 486 486 480 + 487 487 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 488 488 489 489 ... ... @@ -765,7 +765,6 @@ 765 765 ))) 766 766 767 767 768 - 769 769 == 3.4 Configure LT via AT or Downlink == 770 770 771 771 User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands ... ... @@ -2009,8 +2009,16 @@ 2009 2009 ))) 2010 2010 2011 2011 ((( 2012 - 2005 +== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? == 2013 2013 2007 +If the device is not shut down, but directly powered off. 2008 + 2009 +It will default that this is a power-off state. 2010 + 2011 +In modes 2 to 5, DO RO status and pulse count are saved in flash. 2012 + 2013 +After restart, the status before power failure will be read from flash. 2014 + 2014 2014 = 6. Trouble Shooting = 2015 2015 ))) 2016 2016